MDC_DDR Series.B03 Page 3 of 5
DDR Series
9A Active Power Power Terminator
for DDR Memories
Ordering Guide
Model Number Mounting
DDR-9-W3 Single Inline Package (vertical), non-RoHS
DDR-9-W3-C Single Inline Package (vertical), RoHS compliant
DDR-9-W3H Horizontal mount, non-RoHS
DDR-9-W3H-C Horizontal mounting, RoHS compliant
Performance/Functional Specifi cations
Typical at TA = +25°C under nominal line voltage, VOUT = 1.25V, full-load conditions unless noted.
Input
Input Voltage Range 3 to 5.5 Volts (3.3V nominal)
Start-Up Threshold 2 Volts min., 2.5 Volts typ.
Input Current, Current Sourcing Mode
At 3.3VIN, 1.25VOUT 4.15 Amps max.
At 3.3VIN, 0.9VOUT 3.18 Amps max.
At 5VIN, 1.25VOUT 2.75 Amps max.
At 5VIN, 0.9VOUT 2.13 Amps max.
Inrush Transient 0.003A2/sec, maximum
No-load Input Current 70mA typ., 100mA max.
Short Circuit Current 4 Amps
Shut Down Mode Input Current 7mA
Input Refl ected Ripple Current 10mAp-p
VREF Input Range 0.7 to 1.45V
VREF External Reference Current 0.1μA (VREF min. to max., IOUT = ±9A)
Remote On/Off Control
+Positive Logic On = no connection, open collector or
0.8V to +VIN max. applied at 60µA.
Off = 0 to 0.7V or pulled low.
Remote Sense Range + 10% of VOUT
Output
Maximum Output Power 11.36 Watts (VREF = 1.25V)
Minimum Loading No minimum load
Maximum Capacitive Loading 2000μF, OSCON low-ESR (0.02)
10,000μF (aluminum electrolytic)
Output Voltage Accuracy V
REF ±1%
Total Accuracy (Line, Load, Temp.) ±5%
Output Current, Source +9.00 Amps maximum
Output Current, Sink –9.00 Amps maximum
Short Circuit Current 13 Amps
Short Circuit Duration Continuous, output shorted to ground
Short Circuit Protection Fold back technique, autorecovery
Current Limit Inception 11 Amps, sourcing mode
Transfer Characteristics
Effi ciency, Current Sourcing Mode, 9A load
At 3.3VIN, 1.25VOUT 83% typ., 85% max.
At 3.3VIN, 0.9VOUT 78% typ., 80% max.
At 5VIN, 1.25VOUT 82.5% typ., 84.5% max.
At 5VIN, 0.9VOUT 77% typ., 79% max.
Effi ciency, Current Sinking Mode, 9A load
At 3.3VIN, 1.25VOUT 81% typ., 83% max.
At 3.3VIN, 0.9VOUT 74.5% typ., 76.5% max.
At 5VIN, 1.25VOUT 80% typ., 82% max.
At 5VIN, 0.9VOUT 73.5% typ., 75.5% max.
Temperature Coeffi cient ±0.02%/°C
Switching Frequency 550kHz min., 700kHz max.
Line Regulation (VIN = min. to max.) ±0.75%
Load Regulation (VIN = min. to max.) ±1.5%
Dynamic Characteristics
Output Slew Rate 40 Amps/μsec
Load Step, 0 to 9A 175mV, peak deviation
Load Step Settling Time, 0 to 9A 200μsec
Ripple and Noise, 20 MHz bandwidth 40mVp-p, typical
60mVp-p, maximum
Turn-On Time (Remote On/Off
or VIN to VOUT regulated) 5.5msec
Absolute Maximum Ratings
Input Voltage 7Vdc max., 100msec duration
Input Reverse Polarity None
Output Current Current-limited. Device can
withstand indefi nite short circuit.
Storage Temperature –55 to +125 °C
Lead Temperature +300°C, 10 seconds maximum
Absolute maximums are stress ratings. Exposure of devices to any of these conditions
may adversely affect long-term reliability. Proper operation under conditions other than
those listed in the Performance/Functional Specifi cations Table is not implied nor
recommended.
See Absolute Maximum Ratings for allowable input voltage.
Input Ripple Current is tested and specifi ed over a 5-20 MHz bandwidth. Input fi ltering is
C
IN = 200µF, CBUS = 1000µF, LBUS = 1µH.
Current limit inception is given at either cold start-up or after warm-up for VREF = 0.9 or
1.25V.
Mean Time Before Failure is calculated using the Telecordia (Bellcore) SR-332 Method 1,
Case 3, ground fi xed conditions, TCASE = +40°C, Full load.
Environmental
Operating Temperature Range (Ambient)
No derating, vertical mount –40 to +65°C @ 200 lfm airfl ow
Derating See derating curves
PCB/Case Temperature Range –40 to +100°C, no derating.
Thermal Protection/Shutdown 110°C
Storage Temperature Range –55 to +125°C
Altitude 0 to 10,000 feet
Relative Humidity 10% to 90%, non-condensing
Physical, Safety
Outline Dimensions 1.60 x 0.50 x 0.20 inches
40.64 x 12.7 x 5.08mm
Weight 0.25 ounces (7g)
Pin Material Nickel plate over copper alloy
Pin Dimensions 0.02 inches (0.508mm)
Calculated MTBF TBD hours
Electromagnetic Interference Conducted (FCC part 15, EN55055)
Radiated (FCC part 15, EN55055)
Safety UL/cUL 60950-1, CSA-C22.2 No.234
IEC/EN 60950-1