Insulation according to EN 61810-1
1 pole 2 pole
Nominal voltage of supply system V AC 230/400 230/400
Rated insulation voltage V AC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50 µs) 6 6
Dielectric strength V AC 4,000 4,000
Insulation between adjacent contacts
Type of insulation — Basic
Overvoltage category — III
Rated impulse voltage kV (1.2/50 µs) — 4
Dielectric strength V AC — 2,000
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data 46.61 46.52
Bounce time: NO/NC ms 2/6 1/4
Vibration resistance (10…150)Hz: NO/NC g 20/12 20/15
Shock resistance g 20 20
Power lost to the environment without contact current W 0.6 0.6
with rated current W 1.6 2
Recommended distance between relays mounted on PCB mm ≥ 5
Technical data
3
46 Series - Miniature industrial relays 8 - 16 A
Cycles
Contact specification
F 46 - Electrical life (AC) v contact current
Type 46.61
•When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103can be expected.
•In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 46 - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
Cycles
F 46 - Electrical life (AC) v contact current
Type 46.52
Resistive load - cosϕ= 1
Inductive load - cosϕ= 0.4
Resistive load - cosϕ= 1
Inductive load - cosϕ= 0.4
46.61 current limit
46.52 current limit