www.tnb.ca E1
PMA ®Nylon Flexible Conduit Systems
Table of Contents
Nylon Flexible Conduits – Overview ..................................................E2–E7
Conduits .........................................................................................E8–E25
PMAFIX® Fittings .................................................................................E26
Thread Codes ....................................................................................... E27
Connectors for Nylon Flexible Conduits ......................................... E28E57
Large-Size Nylon Flexible Conduits and Fittings ............................ E58E63
Divisible-System Nylon Flexible Conduits and Fittings .......................... E64
Divisible-System Nylon Flexible Accessories ......................................... E65
Special Products .......................................................................... E66E70
Accessories and Tools .................................................................E71–E79
Hazardous Location ATEX Systems .............................................. E80E91
Technical Information ................................................................ E92–E103
www.tnb.ca
E2
Nylon Flexible Conduit Systems
PMA ®
Mechanical Engineering
A considerable number of PMA®
cable protection systems are used
in mechanical engineering. A few
examples illustrate how varied the
range of mechanical engineering
applications is. You will find our
products in machine tools,
packaging machines, printing
machines, as well as heating,
ventilation, conveyer and filling
systems. PMA® products also make
a vital contribution to the smooth
operation of high-voltage and
emergency power systems, can
production machinery and
woodworking machines, etc. PMA®
cable protection solutions safeguard
cables, wires and data links against
heat, cold, tensile stress, pressure
stress and other external influences
in the important mechanical
engineering industry.
Railway/Railway
Infrastructure
PMA® products have proven their
dependability in railway construction
projects around the world. This is
the reason why large corporations
including Siemens, Alstom,
Bombardier, Deutsche Bahn and
SNCF have chosen us as supplier
over a period of many years.
Our special railway engineering
product line provides protection and
safety on signalling systems,
couplings, trucks and gangways,
as well as with roof and underfloor
equipment. The range of
applications is very extensive.
PMA® products contribute to the
safe operation of trams,
locomotives, freight cars,
high-speed trains and even roller
coasters.
Automation
In the field of automation, there is
a need for products that can
withstand the stress of
motion-intensive applications.
Solutions developed by PMA® fully
meet these requirements.
Special conduit designs, supports
and abrasion-protection sleeves
provide optimal protection along
the entire length of all moving
elements, enabling engineers to
achieve a massive reduction in
torsional forces. There is a good
reason why leading robotics man-
ufacturers rely on
PMA® technology.
Countless Applications
PMA® cable protection products can
be used in an extremely wide range
of applications. The list is virtually
endless and includes industries such
as telecommunications, construction
equipment and medical equipment.
Wherever there is a need for cable
protection, the PMA® product
portfolio provides safe, dependable,
forward-looking solutions. We can
also develop custom solutions to
meet your individual needs.
Nylon Flexible Conduits
Overview
www.tnb.ca E3
Nylon Flexible Conduit Systems
PMA ®
PMA® SMART LINE
Connectors and Conduits
Modern, versatile and attractive
One-piece design, IP66 protection and simple, fast
installation are the outstanding features of the Smart Line.
Other characteristics, including a modern, functional design
and an excellent price/performance ratio, make this product
line a very attractive solution.
Connectors: Straight, 45° elbow and 90° elbow
Conduits: Conduit types made of PA6, PA12 and PP
Modes of Protection: IP66
AUTOMATION
Accessories and Robotics
Protection and dependability in automation applications
PMA® products provide optimal cable protection in all
automation applications. They give you dependable
protection against abrasion, and they prevent wearing
through the insulation. They are very flexible and deliver long
service life in motion-intensive applications.
Applications:
Special conduit and accessories for robotics and automation
applications provide:
Reduced mechanical stress
Longer service life
Flexible design for motion-intensive applications
Nylon Flexible Conduits
Overview
PMAFIX® Pro Connectors
State-of-the-Art Design and Manufacturing
Procedure for Highest Sealing Performance
The PMAFIX® Pro fitting series employs two-component
injection-molding technology in a radical new design to set
new standards for the cable protection industry in critical
performance parameters, particularly sealing security.
Connectors: Male and female threads in polyamide and
metal, straight, 45°, 90° and strain-relief types
Conduits: The PMAFIX® Pro system is compatible with the
entire PMAFLEX® Pro and PMAFLEX® conduit range
Modes of Protection: IP68 and IP69K both in static and
dynamic installations
PMA® EX-SYSTEM
Connectors, Conduits and Accessories
Electrostatic load discharging for
explosion-endangered areas
The EX-System includes conduits, fittings and accessories
for flexible protection of cables, wires and hoses against
mechanical damage, UV-radiation and weathering in
explosion-endangered areas classified as zones
1/21 (gas/dust) according to ATEX 137.
Connectors: Straight, 45° elbow, 90° elbow and 90° curved
elbow, distributors
Conduits: Highly flexible, conduit sizes from Ø 10 to 50
Applications: Areas where combustible gases, liquids or
solids and atmospheric oxygen can form an explosive
atmosphere and where any form of ignition has to be
avoided
Installation: Simple push-in installation (IP66), safety and
sealing system (IP68)
PMAFIX®/PMAFLEX®
Connectors and Conduits
Best selling and very popular
This product line offers solutions that meet the highest
expectations: IP66–IP69K. It is based on a perfected system
technology that makes installation easy. You can choose
from a very large, varied range of connectors and conduit
that has demonstrated its dependability in all types of
applications for more than 20 years.
Connectors: Male and female thread in polyamide or metal,
straight, 45° elbow, 90° elbow and 90° curved elbow,
distribution
Conduits: More than 20 different types of conduit: light to
heavy, flexible to highly flexible, conduit size from Ø 6 to 125
Safety System: Unique safety clip system for connection
with PMA conduit
Modes of Protection: IP66, IP68GT, IP68, IP69K
www.tnb.ca
E4
Nylon Flexible Conduit Systems
PMA ®
PMAFLEX
®
Pro PMAFLEX
®
Key: º recommended
l suitable (application details to be considered)
PHT
PLU
POH
PSX
CYF
CYFH
CYL
ESD
ESDP
Application Areas
Machine
Building
General Applications
static
dynamic o
Heavy Loads
static
dynamic
Outdoor Applications
static o
dynamic o
Antistatic Requirements
static
dynamic
Traction
Outdoor Applications with Sunlight Exposure
static
dynamic
Outdoor Applications
static
dynamic
Indoor Applications static
Traction Infra
Outdoor Applications with Sunlight Exposure static
Indoor and Tunnel Applications static
Automation
Moving Systems static o
Systems with E xtreme Movements static
Moving Systems with Antistatic Requirements static
Ship + Off-
Shore
Outdoor General Applications
static
dynamic o
Indoor Applications
static o
dynamic o
Passenger Area static o o
Energy
Outdoor Applications with Sunlight Exposure static
Indoor Applications static o o
Exposed to Radiation static
Others
Vehicle Building static o
Telecommunications
indoor o
outdoor
Building Construction
indoor
outdoor
Ex Hazardous Areas (ATEX) static o
High-Temperature Applications static o
Find on page E18 E18 E19 E19 E9 E9 E9 E10 E10
Nylon Flexible Conduits
Overview
www.tnb.ca E5
Nylon Flexible Conduit Systems
PMA ®
PMAFLEX
®
PMAFLEX
®
Multi-Layer
PMA
®
FLEXPlus
(UL Listed) SMART LINE CoFlex Ex
PCL
PCS
PCSL
PEL
PIS/PIH
POS
PUE
PVD
R90
TEC
VAM
VAML
VCS
VOH
XCYL
XPCL
XSOL
XSOLL
XVCS1H
CUS
PUS
VUS
LLPA
LLPF
LLPO
PACOF
PPCOF
ESX
•••
E11 E11 E12 E12 E13 E13 E14 E14 E15 E15 E16 E16 E17 E21 E21 E22 E22 E23 E24 E24 E25 ——— E20 E20
Nylon Flexible Conduits
Overview
www.tnb.ca
E6
Nylon Flexible Conduit Systems
PMA ®
PMAFLEX
®
Pro PMAFLEX
®
Key: √ = correct
PHT (PAE)
PLU (PO)
POH (PO)
PSX (PEI)
CYF (PA6)
CYFH (PA6)
CYL (PA6)
ESD (PA12)
ESDP (PO)
Material properties
Ductility
Reverse Bending Resistance
Compression Resistance
Low-Temperature Performance
High-Temperature Performance
Resistance to Weathering
Approvals
UL Recognition File
Bi-National Recognition UL and CSA C22.2 No. 227.3-05
Bi-National Recognition UL and CSA C22.2 No. 227.2.1
Free from Halogens and Cadmium
√√√√ √√√√√
Non Flame Propagating EN61386
EN45545
NF F 16-101 + 102
BS6853
DIN 5510-2
UNI CEI 11170-3 Ed. 2005
NFPA130 (ASTM E162 - ASTM E662 - ASTM E1354) BSS7239/SMP 800-C
DNV (Type approved)
Lloyd’s Register (Type approved)
Bureau Veritas (Type approved)
TEMP.
RANGE
Continuous Operating Temperature (Acc. to DO 9.21-4510)
-50 -25 -25 -100 -30 -30 -40 -40 -20
135 95 95 170 90 90 105 90 90
Short-Term Max. Operating Temperature 168h (Acc. to DO 9.21-4360)
180 120 200 125 125 160 150
SIZES
Nominal Widths Min.
07 10 10 10 07 23 07 07 10
Nominal Widths Max.
48 48 48 48 17 48 125 95 48
Metric Size Min.
10 12 12 12 10 25 10 10 12
Metric Size Max.
50 50 50 50 20 50 146 106 50
Nylon Flexible Conduits
Overview
Min.
Max.
www.tnb.ca E7
Nylon Flexible Conduit Systems
PMA ®
PMAFLEX
®
PMAFLEX
®
Multi-Layer PMA
®
FLEXPLUS
(UL LISTED) SMART LINE COFLEX EX
PCL (PA6)
PCS (PA12)
PCSL (PA12)
PEL (PE)
PIS/PIH (PA12)
POS (PO)
PUE (TPU)
PVD (PVDF)
R90 (PA12)
TEC (PFA)
VAM (PA6)
VAML (PA6)
VCS (PA6)
VOH (PA6)
XCYL (PA6/PA6)
XPCL (PA6/PA6)
XSOL (PA12/PA6)
XSOLL (PA12/PA6)
XVCS1H (PA6/PO)
CUS (PA6)
PUS (PA12)
VUS (PA6)
LLPA (PA6)
LLPF (PA6)
LLPO (PO)
PACOF (PA6)
PPCOF (PP)
ESX (PA11)
√√√
√√√√√√√ √√√√ √√√√√ √√√ √√√
√√√ √√√√√ √√√√ √√√ √√√ √√
√√ √√√
√√√ √√√√ √√√
√√√ √√√√ √√√
√√√ √√√√ √√√
-50 -50 -50 -50 -50 -25 -60 -60 -40 -200 -40 -40 -50 -40 -40 -50 -50 -40 -50 -40 -50 -50 -40 -40 -20 -40 -20 -50
105 95 95 60 95 95 50 150 95 200 105 105 105 105 105 105 95 95 90 105 95 105 105 105 90 100 95 90
160 150 150 150 130 150 260 160 160 160 160 160 160 150 150 120 160 150 160 160 160 130 150 120 150
07 07 07 10 07 07 12 10 29 10 07 07 07 07 12 12 12 12 12 17 17 17 07 07 07 07 07 10
125 95 48 48 125 95 70 29 70 29 48 125 95 125 48 48 48 48 48 48 48 48 125 48 48 70 70 48
10 10 10 12 10 10 16 12 32 12 10 10 10 10 16 16 16 16 16 20 20 20 10 10 10 10 10 12
146 106 50 50 146 106 80 32 80 32 50 146 106 146 50 50 50 50 50 50 50 50 146 50 50 80 80 50
Nylon Flexible Conduits
Overview
www.tnb.ca
E8
Nylon Flexible Conduit Systems
PMA ®
** stat. R = lowest recommended
bending radius for static
(fixed) installation.
*** dyn. R = lowest recommended
bending radius for dynamic
(flexible) installation.
Fine profile T
Tight bending
radius
Coarse profile G
High pullout strength
d2
R
PMAFLEX® covers more than 20 diffe rent conduit types for a variety of applications in cable
protection. The PMAFLEX® range offers conduits for technically demanding applications and
spe cial requi rements.
Conduit sizes range from 6 to 125 diameters, from lightweight to heavyweight, and pliable to
highly flexible. Standard colours are black and grey.
Many conduits are specially approved, e.g. CSA, UL Recognition, NF, SNCF, DB, etc.
Conduits
PMAFLEX® Conduits
XPCLT-12SG
XPCL T- 12 S G
Multi-Layer
Conduit Type Profile Nominal
Width Colour Colour Inner
Layer
T = Fine profile B = BLACK G = GREEN
d = Fine profile s = GREY B = BLUE
c = Coarse profile
www.tnb.ca E9
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -30° C to 90° C; Short term to 125° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
CYFT-07B
7 10 6.2 10.0 15
100
CYFT-10B
10 12 9.6 13.0 20
CYFT-12B
12 16 12.0 15.8 30
CYFT-17B
17 20 16.2 21.2 40
CYFHG-23B
23 25 21.4 28.5 50
50
CYFHG-29B
29 32 27.2 34.4 60
CYFHG-36B
36 40 35.8 42.4 70
CYFHG-48B
48 50 46.8 54.4 80
For actual cat. number, add PU METER at the end. Example: CYFT-07B.100
CYF Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
CYFH Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
CYL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
CYLT-07B CYLT-07S
7 10 6.2 10.0 15
50
CYLT-10B CYLT-10S
10 12 9.6 13.0 20
CYLT-12B* CYLT-12S*
12 16 12.0 15.8 30
CYLT-17B* CYLT-17S*
17 20 16.2 21.2 40
CYLT-23B* CYLT-23S*
23 25 22.6 28.5 45
CYLT-29B* CYLT-29S*
29 32 29.0 34.5 55
CYLT-36B* CYLT-36S*
36 40 36.5 42.5 60 30
CYLT-48B* CYLT-48S*
48 50 47.5 54.5 70
CYLG-23B* CYLG-23S*
23 25 21.9 28.5 45 50
CYLG-29B* CYLG-29S*
29 32 27.6 34.5 55
CYLG-36B* CYLG-36S*
36 40 36.0 42.5 60
30
CYLG-48B* CYLG-48S*
48 50 47.0 54.5 70
CYLG-56B CYLG-56S
56 68 56.3 67.2 120
CYLG-70B CYLG-70S
70 80 68.0 80.0 160 10
CYLG-95B CYLG-95S
95 106 91.9 106.0 210
CYLG-125B CYLG-125S
125 146 126.5 146.5 450 6
* CSA certified
For actual cat. number, add PU METER at the end. Example: CYLT-07B.50
CYL Very Flexible, Medium
Use in machine building and installation industries
High-grade, specially formulated polyamide 6
Very good flexibility
Good impact strength at low temperatures and in dry conditions
Self extinguishing
Free from halogens and cadmium
Temperature range: -40° C to 105° C; Short term
to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc. (see page E102-E103)
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Use in automobile and truck industries
High-grade, specially modified polyamide 6
CYF: medium-wall (NW 07 to 17); CYFH:
heavy-wall (NW 23 to 48)
Self extinguishing
Free from halogens and cadmium
Good impact strength at low temperatures
and in dry conditions
Conduits
CYF/CYFH Flexible, Medium/Heavy
www.tnb.ca
E10
Nylon Flexible Conduit Systems
PMA ®
For dynamic applications in robotics and
automation where electrostatic charge and
uncontrolled discharge need to be avoided
High-grade, specially modified polyamide 12
Prevents electrostatic charging
For indoor and outdoor use (very good cold
temperature performance)
Excellent UV resistance and high
dynamic-load resistance
Free from halogens and cadmium
Temperature range: -40° C to 90° C;
Short term to 150° C
Chemical Resistance: Fuels, mineral oils, fats,
alkalies, acids, etc.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
ESDT-07B
07 10 6.2 10.0 15
50
ESDT-10B
10 12 9.6 13.0 20
ESDT-12B
12 16 12.0 15.8 30
ESDT-17B
17 20 16.4 21.1 40
ESDT-23B
23 25 22.6 28.4 45
ESDT-29B
29 32 29.0 34.3 55
ESDT-36B
36 40 36.5 42.5 60
30
ESDT-48B
48 50 47.5 54.5 70
ESDG-56B
56 68 56.5 67.0 110
ESDG-70B
70 80 67.5 80.0 150 10
ESDG-95B
95 106 91.5 106.0 170
For actual cat. number, add PU METER at the end. Example: ESDT-07B.50
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius * (mm)
PU
Meter
ESDPT-07B
710 6.2 10.0 15
50
ESDPT-10B
10 12 9.6 13.0 20
ESDPT-12B
12 16 12.0 15.8 30
ESDPT-17B
17 20 16.4 21.1 40
ESDPT-23B
23 25 22.6 28.4 45
ESDPT-29B
29 32 29.0 34.3 55
ESDPT-36B
36 40 36.5 42.5 60 30
ESDPT-48B
48 50 47.5 54.5 70
For actual cat. number, add PU METER at the end. Example: ESDPT-07B.50
ESD Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
ESDP Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
ESDP Very Flexible, Medium
For dynamic applications in automation, electronics and clean rooms where
electrostatic charging and uncontrolled discharge must be avoided
High-grade, specially modified polyolefin
Prevents electrostatic charging
Minimal migration
Very good dynamic load resistance and good impact resistance
Free from halogens and cadmium
Temperature range: -20° C to 90° C continuous
Chemical Resistance: Fuels, mineral oils, fats,
alkalies, strong acids, etc.
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Conduits
ESD Very Flexible, Medium
NEW!
NEW!
www.tnb.ca E11
Nylon Flexible Conduit Systems
PMA ®
PSC Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Specially modified polyamide 6/6.6
for cold impact
Very good flexibility
Self extinguishing
Free from halogens and cadmium
High impact strength also at low
temperatures
PCL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -50° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
PCLT-07B PCLT-07S
7 10 6.2 10.0 15
50
PCLT-10B PCLT-10S
10 12 9.6 13.0 20
PCLT-12B* PCLT-12S
12 16 12.0 15.8 30
PCLT-17B * PCLT-17S*
17 20 16.2 21.2 40
PCLT-23B* PCLT-23S*
23 25 22.6 28.5 45
PCLT-29B* PCLT-29S*
29 32 29.0 34.5 55
PCLT-36B* PCLT-36S*
36 40 36.5 42.5 60 30
PCLT-48B* PCLT-48S*
48 50 47.5 54.5 70
PCLG-17B* PCLG-17S*
17 20 15.3 21.2 40
50
PCLG-23B* PCLG-23S*
23 25 21.9 28.5 45
PCLG-29B* PCLG-29S*
29 32 27.6 34.5 55
PCLG-36B* PCLG-36S*
36 40 36.0 42.5 60
30
PCLG-48B* PCLG-48S*
48 50 47.0 54.5 70
PCLG-56B PCLG-56S
56 68 56.3 67.2 130
PCLG-70B PCLG-70S
70 80 67.5 80.0 160 10
PCLG-95B PCLG-95S
95 106 91.5 106.0 210
PCLG-125B PCLG-125S
125 146 126.5 146.5 450 6
*CSA certified.
For actual cat. number, add PU METER at the end. Example: PCLT-07B.50
PCS Highly Flexible, Heavy
High-grade, specially modified polyamide 12
Excellent resistance to ultraviolet rays and atmospheric corrosion
Excellent flexibility and is self extinguishing
Good mechanical strength at low temperatures and dry conditions
Free from halogens and cadmium
Conduits
PCL Very Flexible, Medium
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
PCST-07B PCST-07S
7 10 6.0 10.0 15/40 100
PCST-10B PCST-10S
10 12 9.2 13.0 20/50
50
PCST-12B* PCST-12S*
12 16 11.8 15.8 25/70
PCST-17B* PCST-17S*
17 20 16.0 21.2 35/80
PCSG-17B* PCSG-17S*
17 20 15.2 21.2 35/85
PCSG-23B* PCSG-23S*
23 25 22.0 28.5 40/110
PCSG-29B* PCSG-29S*
29 32 27.7 34.4 50/130
PCSG-36B* PCSG-36S*
36 40 35.8 42.4 60/180
30
PCSG-48B* PCSG-48S*
48 50 46.8 54.4 70/220
PCSG-56B PCSG-56S
56 68 56.1 67.2 130/280
PCSG-70B PCSG-70S
70 80 66.5 80.0 170/360
10
PCSG-95B PCSG-95S
95 106 91.0 106.0 250/470
*CSA certified.
For actual cat. number, add PU METER at the end. Example: PCST-07B.100
www.tnb.ca
E12
Nylon Flexible Conduit Systems
PMA ®
PCSL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for
static (fixed)
installation.
Use in dynamic installations in railway
vehicules, or in external applications like
solar systemsand signalling
High-grade, specially modified polyamide 12
Excellent resistance to ultraviolet rays and
atmospheric corrosion
Excellent flexibility
Good mechanical strength at low
temperatures and dry conditions
Self-extinguishing properties
Free from halogens and cadmium
Temperature range: -50° C to 95° C;
Short term to 150° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
PEL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -50° C to 60° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius_ (mm)
PU
Meter
PCSLT-07B PCSLT-07S
7 10 6.2 10.0 15
50
PCSLT-10B PCSLT-10S
10 12 9.6 13.0 20
PCSLT-12B PCSLT-12S
12 16 11.9 15.8 25
PCSLT-17B PCSLT-17S
17 20 16.4 21.1 30
PCSLG-17B PCSLG-17S
17 20 15.2 21.1 30
PCSLG-23B PCSLG-23S
23 25 21.7 28.4 40
PCSLG-29B PCSLG-29S
29 32 27.4 34.3 50
PCSLG-36B PCSLG-36S
36 40 35.8 42.3 60 30
PCSLG-48B PCSLG-48S
48 50 46.7 54.2 70
For actual cat. number, add PU METER at the end. Example: PCSLT-07B.50
Cat. No.
Grey
Cat. No.
Slitted Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius (mm)
PU
Meter
PELT-10S PELT-10SL
10 12 9.7 12.7 20
50
PELT-12S PELT-12SL
12 16 11.5 15.5 30
PELT-17S PELT-17SL
17 20 16.0 20.9 35
PELT-23S PELT-23SL
23 25 22.5 27.5 40
30
PELT-29S PELT-29SL
29 32 28.5 33.8 50
PELT-36S PELT-36SL
36 40 34.0 41.6 60
PELT-48S PELT-48SL
48 50 47.0 53.2 70
For actual cat. number, add PU METER at the end. Example: PELT-10S.50
PEL Highly Flexible, Light/Soft
Use in electrical cabinets and appliance construction
Specially modified polyethylene
Self extinguishing
Low stiffness
Conduits
PCSL Very Flexible, Medium-Duty
www.tnb.ca E13
Nylon Flexible Conduit Systems
PMA ®
PIS/PIH Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
POS Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Use in dynamic applications in robotics
and automation
High-grade, specially modified polyamide 12
PIS: medium-wall (nominal width 07 to 48)
PIH: heavy-wall (nominal width 56 to 125)
Excellent resistance to ultraviolet rays and
atmospheric corrosion
Self extinguishing
Excellent flexibility
Free from halogens and cadmium
Good mechanical strength at low temperatures
and dry conditions
Temperature range: -50° C to 95° C;
Short term to 150° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Use in automation as well as in machine building
and industrial installations, especially where
continuous movements occur
High-grade, specially modified polyolefin
Excellent reversed bending performance
and flexibility
Very good insulating characteristics
Good impact resistance
Free from halogens and cadmium
Temperature range: -25° C to 95° C;
Short term to 130° C
Chemical resistance: Strong acids
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
PIST-07B PIST-07S
710 6.2 10.0 15/40
50
PIST-10B PIST-10S
10 12 9.6 13.0 20/50
PIST-12B_ PIST-12S_
12 16 11.9 15.8 25/65
PIST-17B_ PIST-17S_
17 20 16.4 21.1 30/65
PIST-23B_ PIST-23S_
23 25 22.6 28.4 35/90
PIST-29B_ PIST-29S_
29 32 29.0 34.3 45/110
PIST-36B_ PIST-36S_
36 40 36.5 42.5 60/165 30
PIST-48B_ PIST-48S_
48 50 47.5 54.5 70/180
PISG-17B_ PISG-17S_
17 20 15.2 21.1 30/80
50
PISG-23B_ PISG-23S_
23 25 21.7 28.4 40/100
PISG-29B_ PISG-29S_
29 32 27.4 34.3 50/120
PISG-36B_ PISG-36S_
36 40 35.8 42.3 60/180
30
PISG-48B_ PISG-48S_
48 50 46.7 54.2 70/200
PIHG-56B PIHG-56S
56 68 56.3 67.2 110/270
PIHG-70B PIHG-70S
70 80 67.2 79.6 150/350
PIHG-95B PIHG-95S
95 106 91.3 106.0 170/450
PIHG-125B PIHG-125S
125 146 126.5 146.5 350/480 20
_ UL Recognized Component.
For actual cat. number, add PU METER at the end. Example: PIST-07B.50
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius † (mm)
PU
Meter
POST-07B POST-07S
710 6.2 10.0 15
50
POST-10B POST-10S
10 12 9.6 13.0 20
POST-12B POST-12S
12 16 11.9 15.8 30
POST-17B POST-17S
17 20 16.2 21.2 35
POST-23B POST-23S
23 25 22.6 28.5 40
POST-29B POST-29S
29 32 29.0 34.5 50
POST-36B POST-36S
36 40 36.5 42.5 60 30
POST-48B POST-48S
48 50 47.5 54.5 70
POSG-29B POSG-29S
29 32 27.6 34.5 50 50
POSG-36B POSG-36S
36 40 36.0 42.5 60
30
POSG-48B POSG-48S
48 50 47.0 54.5 70
POSG-70B POSG-70S
70 80 67.2 79.6 150
POSG-95B POSG-95S
95 106 91.3 106.0 170
For actual cat. number, add PU METER at the end. Example: POST-07B.50
POS Very Flexible, Medium-Duty
Conduits
PIS/PIH Highly Flexible, Medium- and Heavy-Duty
www.tnb.ca
E14
Nylon Flexible Conduit Systems
PMA ®
PUE Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
PVD Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PUET-12B
12 16 11.8 15.8 25/45
50
PUET-17B
17 20 16.0 21.2 30/50
PUET-23B
23 25 22.4 28.5 35/70
PUET-29B
29 32 28.8 34.5 40/90 30
PUET-36B
36 40 35.8 42.4 50/120
PUET-48B
48 50 48.6 54.5 60/130 21
PUEG-56B
56 68 56.3 67.2 90/170 30
PUEG-70B
70 80 68.2 80.5 100/220
For actual cat. number, add PU METER at the end. Example: PUET-12B.50
Use in dynamic applications in robotics
and automation
Specially modified polyurethane
Free from halogens and cadmium
Excellent chafing properties
Temperature range: -60° C to 50° C
Chemical resistance: Fuels, mineral oils and fats, etc.
Temperature range: -60° C to 150° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, strong acids, etc.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PVDT-10P
10 12 9.5 12.6 10
50
PVDT-12P
12 16 11.8 15.5 30
PVDT-17P
17 20 16.0 20.8 40
PVDT-23P
23 25 22.6 28.0 45
PVDT-29P
29 32 29.0 34.1 50
For actual cat. number, add PU METER at the end. Example: PVDT-10P.50
PVD Pliable, Medium
Use in machine building applications with long-term high-temperature
requirements as well as in the chemical and food industries
Specially formulated PVDF
Excellent chemical resistance also at high temperatures
Self extinguishing and free from cadmium
Excellent UV resistance and very good
abrasion resistance
High stiffness
Conduits
PUE Highly Flexible, Medium
www.tnb.ca E15
Nylon Flexible Conduit Systems
PMA ®
TEC Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
VAM Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
TECT-10B
10 12 9.9 13.0 950
TECT-13B
13 12.5 16.0 12
TECT-17B
17 20 16.8 21.1 15
25
TECT-23B
23 25 23.8 28.8 26
TECT-29B
29 32 28.2 33.0 30
For actual cat. number, add PU METER at the end. Example: TECT-10B.50
Use in chemical installations or applications
with increased temperature requirements
Specially formulated PFA
Very good resistance to extreme low and
high temperatures
Self extinguishing
Excellent resistance to highly corrosive
chemicals
Temperature range: -200° C to 200° C;
Short term to 260° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, strong acids, etc.
In passenger areas of railway vehicles
Excellent fire safety characteristics allow
application in public buildings like hospitals,
hotels, airports, train and subway
High-grade, specially formulated polyamide 6
Good resistance to ultraviolet rays and
weathering
High impact and compression strength
High stiffness
Free from halogens and cadmium
Outstanding self-extinguishing characteristics
Minimal development of smoke and gases
Temperature range: -40° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
VAMT-07B VAMT-07S
7 10 6.0 10.0 20
50
VAMT-10B VAMT-10S
10 12 9.2 13.0 25
VAMT-12B VAMT-12S
12 16 11.8 15.8 30
VAMT-17B VAMT-17S
17 20 16.0 21.2 40
VAMG-17B VAMG-17S
17 20 15.2 21.2 40
VAMG-23B VAMG-23S
23 25 22.0 28.5 50
VAMG-29B VAMG-29S
29 32 27.7 34.4 60
VAMG-36B VAMG-36S
36 40 35.8 42.4 70 30
VAMG-48B VAMG-48S
48 50 46.8 54.4 80
For actual cat. number, add PU METER at the end. Example: VAMT-07B.50
VAM Flexible, Heavy
Conduits
TEC Flexible, Light-Duty
www.tnb.ca
E16
Nylon Flexible Conduit Systems
PMA ®
VAML Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
VCS Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for
static (fixed)
installation.
Use in passenger areas of railway vehicles
Excellent fire safety characteristics for
public buildings
Specially modified polyamide 6
Good impact strength
Good resistance to ultraviolet rays
and weathering
Outstanding self-extinguishing characteristics
Minimal development of smoke and gases
Free from halogens and cadmium
Temperature range: -40° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
VCS Flexible, Heavy
Use in external applications, static
installations in railway vehicles
High-grade, specially formulated
polyamide 6
Very good resistance to ultraviolet rays
and weathering
Good flexibility
Self extinguishing
High compression and impact strengths
at low temperature and low humidity
Free from halogens and
cadmium
Temperature range: -50° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
VAMLT-07B VAMLT-07S
710 6.2 10.0 15
50
VAMLT-10B VAMLT-10S
10 12 9.6 13.0 20
VAMLT-12B VAMLT-12S
12 16 12.0 15.8 30
VAMLG-17B VAMLG-17S
17 20 15.3 21.2 40
VAMLG-23B VAMLG-23S
23 25 22.6 28.5 45
VAMLG-29B VAMLG-29S
29 32 27.6 34.5 55
VAMLG-36B VAMLG-36S
36 40 36.0 42.5 65
30
VAMLG-48B VAMLG-48S
48 50 47.0 54.5 75
VAMLG-56B VAMLG-56S
56 68 56.3 67.2 140
VAMLG-70B VAMLG-70S
70 80 67.5 80.0 160 10
VAMLG-95B VAMLG-95S
95 106 91.5 106.0 210
VAMLG-125B VAMLG-125S
125 148 126.0 146.5 450 6
For actual cat. number, add PU METER at the end. Example: VAMLT-07B.50
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
VCST-07B VCST-07S
710 6.0 10.0 20 100
VCST-10B VCST-10S
10 12 9.2 13.0 25
50
VCST-12B* VCST-12S*
12 16 11.8 15.8 30
VCST-17B* VCST-17S*
17 20 16.0 21.2 40
VCSG-17B* VCSG-17S*
17 20 15.2 21.2 40
VCSG-23B* VCSG-23S*
23 25 22.0 28.5 50
VCSG-29B* VCSG-29S*
29 32 27.7 34.4 60
VCSG-36B* VCSG-36S*
36 40 35.8 42.4 70
30
VCSG-48B* VCSG-48S*
48 50 46.8 54.4 80
VCSG-56B VCSG-56S
56 68 56.1 67.2 150
VCSG-70B VCSG-70S
70 80 66.5 80.0 200 10
VCSG-95B VCSG-95S
95 106 91.0 106.0 300
For actual cat. number, add PU METER at the end. Example: VCST-07B.100
Conduits
VAML Flexible, Medium
www.tnb.ca E17
Nylon Flexible Conduit Systems
PMA ®
VOH Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Use to make exterior connections
on heavy machine equipment
High-grade specially modified polyamide 6
High degree of mechanical protection and
outstanding pullout resistance
For exterior applications in machinery and
installations from nominal width 17 accor-
ding to UL standards
Self extinguishing
Robust construction
Free from halogens and cadmium
Temperature range: -40° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
VOHD-07B VOHD-07S
710 5.8 10.0 30
50
VOHD-10B VOHD-10S
10 12 9.0 13.0 35
VOHD-12B VOHD-12S
12 16 11.6 15.8 40
VOHG-17B VOHG-17S
17 20 14.5 21.0 60
VOHG-23B VOHG-23S
23 25 21.1 28.5 70
VOHG-29B VOHG-29S
29 32 26.6 34.5 80
VOHG-36B VOHG-36S
36 40 35.0 42.5 90
30
VOHG-48B VOHG-48S
48 50 46.5 54.5 100
VOHG-56B VOHG-56S
56 68 55.5 67.2 135
VOHG-70B VOHG-70S
70 80 67.0 80.0 200 10
VOHG-95B VOHG-95S
95 106 90.5 106.0 300
VOHG-125B VOHG-125S
125 146 126.0 146.5 300 6
For actual cat. number, add PU METER at the end. Example: VOHD-07B.50
Conduits
VOH Pliable, Very Heavy
www.tnb.ca
E18
Nylon Flexible Conduit Systems
PMA ®
PHT Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat./DYN
Radius (mm)
PU
Meter
PHTT-07B
07 10 6.2 10.0 15/40
50
PHTT-10B
10 12 9.6 13.0 20/55
PHTT-12B
12 16 12.0 15.8 30/65
PHTT-17B
17 20 16.2 21.2 40/70
PHTT-23B
23 25 22.6 28.5 45/95
PHTG-17B
17 20 15.2 21.2 40/75
PHTG-23B
23 25 22.0 28.5 45/100
PHTG-29B
29 32 27.7 34.5 55/120
PHTG-36B
36 40 35.8 42.5 60/180 30
PHTG-48B
48 50 46.8 54.5 70/200
For actual cat. number, add PU METER at the end. Example: PHTT-07B.50
For applications at high and very low
temperatures
For dynamic applications
High-grade, specially formulated
polyamide elastomer
High resistance to ultraviolet rays and
atmospheric corrosion
Excellent flexibility and high
compression strength
Extremely good impact resistance at very
low temperatures
Enhanced temperature range compared
to standard polyamides
Free from halogens and cadmium
Temperature range: -50° C to 135° C;
Short term: 180° C
PLU Flexible, Medium-Duty, Semi-Rigid,
for Static Applications
For static applications with the highest
fire safety performance requirements
(e.g. London Underground)
Specially modified polyolefin
Excellent flammability characteristics
Self-extinguishing properties
Very good insulating characteristics
Very good flexibility
Impact resistance
Free from halogens and cadmium
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PLUT-10B PLUT-10S
10 9.5 13.0 20
50
50
PLUT-12B PLUT-12S
12 11.8 15.8 30
PLUG-17B PLUG-17S
17 15.3 21.2 40
PLUG-23B PLUG-23S
23 22.2 28.5 45
PLUG-29B PLUG-29S
29 28.7 34.5 55
PLUG-36B PLUG-36S
36 36.3 42.5 65 30
PLUG-48B PLUG-48S
48 47.3 54.5 70
For actual cat. number, add PU METER at the end. Example: PLUT-10B.50
PLU Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -25° C to 95° C
Chemical resistance: Strong acids and alkalies
Conduits
PHT Highly Flexible, Medium/Heavy-Duty
NEW!
NEW!
NEW!
NEW!
www.tnb.ca E19
Nylon Flexible Conduit Systems
PMA ®
POH Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
PSX Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PSXT-10B
10 12 9.8 13.0 20
50
PSXT-12B
12 16 12.2 15.8 30
PSXG-17B
17 20 15.8 21.2 40
PSXG-23B
23 25 22.3 28.5 45
PSXG-29B
29 32 28.0 34.5 55
PSXG-36B
36 40 36.5 42.5 60
PSXG-48B
48 50 47.5 54.5 70 30
For actual cat. number, add PU METER at the end. Example: PSXT-10B.50
For applications with the highest fire safety
performance requirements
Specially modified polyolefin
Excellent fire safety characteristics
Self extinguishing
Free from halogens and cadmium
High ductility and formability enable
easy installation
Very good flexibility
Very good insulating characteristics
Impact resistance
Temperature range: -25° C to 95° C;
Short term +120° C
Chemical resistance: Strong acids and alkalies
PSX Flexible, Light-Wall
For applications with the highest fire safety
performance requirements
For applications with extreme
temperature conditions
For applications exposed to radiation
Specially modified polyetherimide
Excellent fire safety characteristics
Self extinguishing
Very good insulating characteristics
High radiation resistance
Good flexibility
Impact resistant
Low smoke density and toxicity
Free from halogens and cadmium
High impact strength also at low
temperatures
Temperature range: -100° C to 170° C;
Short term to 200° C
Chemical resistance: Oils, fats, acids, alcohols
and hot water
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
POHT-10B POHT-10S
10 12 9.2 13.0 13.0
50
POHT-12B POHT-12S
12 16 11.8 15.8 15.8
POHG-17B POHG-17S
17 20 15.7 21.2 21.2
POHG-23B POHG-23S
23 25 22.0 28.5 28.5
POHG-29B POHG-29S
29 32 27.4 34.4 34.4
POHG-36B POHG-36S
36 40 35.8 42.4 42.4 30
POHG-48B POHG-48S
48 50 46.8 54.5 54.5
For actual cat. number, add PU METER at the end. Example: POHT-10B.50
Conduits
POH Very Flexible, Very Supple, Very High Stability,
Medium-Duty, Highest Levels of Fire and Passenger Safety
NEW!
NEW!
NEW!
NEW!
www.tnb.ca
E20
Nylon Flexible Conduit Systems
PMA ®
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PACOF-07B
07 5.6 10.0 30
50
PACOF-10B
10 8.5 12.8 33
PACOF-12B
12 11.0 15.6 35
PACOF-17B
17 15.5 21.1 45
PACOF-23B
23 22.1 28.4 70
PACOF-29B
29 27.2 34.5 120
PACOF-36B
36 32.0 42.4 145 30
PACOF-48B
48 43.9 54.1 150
PACOF-70B
70 62.0 79.0 190 10
For actual cat. number, add PU METER at the end. Example: PACOF-07B.50
Cat. No.
Black
Conduit Size
NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PPCOF-07B
07 5.6 10.0 25
50
PPCOF-10B
10 8.5 12.8 28
PPCOF-12B
12 11.0 15.6 35
PPCOF-17B
17 15.1 21.1 45
PPCOF-23B
23 22.1 28.4 60
PPCOF-29B
29 26.6 34.5 100
PPCOF-36B
36 31.8 42.4 120 30
PPCOF-48B
48 43.9 54.1 140
PPCOF-70B
70 60.5 78.0 200 10
For actual cat. number, add PU METER at the end. Example: PPCOF-07B.50
Use in machine building and plant
construction
Specially modified polyamide 6
Easy installation and trouble-free
retrofitting, applicable also for repairs
Can be opened and closed again
in longitudinal direction any time
Self extinguishing
Free from halogens and cadmium
PACOF Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -40° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
PPCOF Flexible, Divisible
Use in machine building and plant
construction
Specially modified polypropylene PP
Easy installation and trouble-free
retrofitting, applicable also for repairs
Can be opened and closed again
in longitudinal direction any time
PPCOF Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -20° C to 105° C;
Short term to 150° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
Conduits
PACOF Flexible, Divisible
www.tnb.ca E21
Nylon Flexible Conduit Systems
PMA ®
XCYL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
XPCL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XCYLT-12BB
12 16 11.7 15.5 30
50
XCYLT-17BB
17 20 15.2 21.0 40
XCYLT-23BB
23 25 21.7 28.4 50
XCYLT-29BB
29 32 27.5 34.3 60
XCYLT-36BB
36 40 35.8 42.2 70 30
XCYLT-48BB
48 50 46.8 54.3 80
For actual cat. number, add PU METER at the end. Example: XCYLT-12BB.50
Use in machine building and equipment
Outer layer: high-grade, specially formu-
lated polyamide 6
Inner layer: specially modified polyolefin
Very long lifetime — more than 20 years
Excellent cold temperature performance
Low-friction inner layer facilitates cable
insertion
Very good resistance to ultraviolet rays
and atmospheric corrosion
Very good mechanical strength while
simultaneously highly flexible
Impermeable to water and steam
Temperature range: -40° C to +105° C;
Short term to +160° C
XPCL Highly Flexible, Medium-Duty
Use in machine building and equipment with
high requirements
Outer layer: high-grade, specially
formulated polyamide 6
Intermediate layer: special bonding
compound
Inner layer: specially modified polyolefin
Self extinguishing
Very long lifetime, 15–20 years for standard
applications
Easy cable inseration, low-friction inner
layer
Impermeable to water and steam
Excellent flexibility
Good mechanical strength even at low
temperatures and low humidity
Temperature range: -50° C to +105° C;
Short term to +160° C
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XPCLT-12BB XPCLT-12SB
12 16 11.8 15.6 30 50
XPCLT-17BB XPCLT-17SB
17 20 16.6 21.0 40 50
XPCLG-17BB XPCLG-17SB
17 20 15.6 20.9 40 50
XPCLG-23BB XPCLG-23SB
23 25 21.9 28.5 45 50
XPCLG-29BB XPCLG-29SB
29 32 27.6 34.5 55 50
XPCLG-36BB XPCLG-36SB
36 40 36.0 42.5 60 30
XPCLG-48BB XPCLG-48SB
48 50 47.0 54.5 70 30
For actual cat. number, add PU METER at the end. Example: XPCLT-12BB.50
Conduits
XCYL Very Flexible, Medium-Duty
NEW!
NEW!
NEW!
NEW!
www.tnb.ca
E22
Nylon Flexible Conduit Systems
PMA ®
XSOLL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XSOLT-12BG
12 16 11.8 15.6
50 50
XSOLG-17BG
17 20 15.2 21.0
XSOLG-23BG
23 25 22.0 28.5
XSOLG-29BG
29 32 27.5 34.5
XSOLG-36BG
36 40 35.8 42.5 30 30
XSOLG-48BG
48 50 46.8 54.5
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XSOLLT-12BG
12 16 11.8 15.8
50 50
XSOLLG-17BG
17 20 15.2 21.2
XSOLLG-23BG
23 25 22.0 28.5
XSOLLG-29BG
29 32 27.7 34.4
XSOLLG-36BG
36 40 35.8 42.4 30 30
XSOLLG-48BG
48 50 46.8 54.4
For actual cat. number, add PU METER at the end. Example: XSOLLT-12BG.50
All-purpose, especially in long-term external
applications, e.g. energy technology,
transportation
Outer layer: high-grade, specially
formulated polyamide 12
Intermediate layer: special bonding
compound
Inner layer: high-grade, specially modified
polyamide 6
Very long lifetime, up to 20–30 years
Very high flexibility
Very good mechanical strength
High impact resistance at low temperature
and humidity
Excellent fire safety characteristics
Excellent chemical resistance
Free from halogens and cadmium
XSOLL Highly Flexible, Medium-Duty
All-purpose, especially in long-term external
applications, e.g. energy technology,
transportation, etc.
Outer layer: high-grade, specially
formulated polyamide 12
Intermediate layer: special bonding
compound
Inner layer: high-grade, specially modified
polyamide 6
Very long lifetime — greater than 20 years
Very good resistance to UV and weathering
High flexibility and very good mechanical
strength
High impact resistance at low temperature
and humidity
Good fire safety characteristics
Excellent chemical resistance
Free from halogens and cadmium
Temperature range: -40° C to +95° C;
Short term to +150° C
XSOL Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -50° C to +95° C;
Short term to +150° C
Conduits
XSOL Highly Flexible, Medium-Duty
NEW!
NEW!
NEW!
NEW!
www.tnb.ca E23
Nylon Flexible Conduit Systems
PMA ®
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended bending
radius for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XVCS1H-12BG† 12 16 11.7 15.5 30
50
XVCS1H-17BG 17 20 15.2 21.0 40
XVCS1H-23BG 23 25 21.7 28.4 50
XVCS1H-29BG 29 32 27.5 34.3 60
XVCS1H-36BG 36 40 35.8 42.2 70 30
XVCS1H-48BG 48 50 46.8 54.3 80
† XVCS1H-12BG is not a UL Recognized Component.
For actual cat. number, add PU METER at the end. Example: XVCS1H-12BG.50
Use in track side applications
Outer layer: high-grade, specially formu-
lated polyamide 6
Inner layer: specially modified polyolefin
High conduit ductility and formability enable
easy installation
Very long lifetime — greater than 20 years
Excellent cold temperature performance
Low friction inner layer facilitates cable
insertion
Very good resistance to ultraviolet rays
and atmospheric corrosion
Very good mechanical strength while
simultaneously highly flexible
Impermeable to water and steam
XVCS1H Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -50° C to +90° C;
Short term to +120° C
Conduits
XVCS1H Flexible, Heavy-Duty
NEW!
NEW!
www.tnb.ca
E24
Nylon Flexible Conduit Systems
PMA ®
CUS Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
PUS Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended bending
radius for static (fixed) instal-
lation.
Conduits
CUS Flexible, Heavy
Use in machine building and in electrical
installations
High-grade, specially modified polyamide 6
Cost effective
Very good flexibility
Good impact strength also at low
temperatures and dry conditions
Self extinguishing
Free from halogens and cadmium
Temperature range: -40° C to 105° C;
Short term to 160° C
PUS Very Flexible, Heavy
Use in long-term external and dynamic
applications, like solar systems,
signalling, CCTV
High-grade, specially modified polyamide 12
Excellent resistance to ultraviolet rays and
atmospheric corrosion
Excellent flexibility and is self extinguishing
Good mechanical strength at low
temperatures and dry conditions
Free from halogens and cadmium
Temperature range: -50° C to 95° C;
Short term to 150° C
Chemical resistance: Fuels, mineral oils, fats,
alkalies, weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
CUSG-17B CUSG-17S
17 20 16.2 21.2 40
31
CUSG-23B CUSG-23S
23 25 21.9 28.5 45
CUSG-29B CUSG-29S
29 32 27.6 34.4 55
CUSG-36B CUSG-36S
36 40 36.0 42.4 60
CUSG-48B CUSG-48S
48 50 47.0 54.4 70
For actual cat. number, add PU METER at the end. Example: CUSG-17B.31
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat./DYN
Radius* (mm)
PU
Meter
PUSG-17B PUSG-17S 17 20 15.2 21.2 35/85
31
PUSG-23B PUSG-23S 23 25 22.0 28.5 40/110
PUSG-29B PUSG-29S 29 32 27.7 34.4 50/130
PUSG-36B PUSG-36S 36 40 35.8 42.4 60/180
PUSG-48B PUSG-48S 48 50 46.8 54.4 70/220
For actual cat. number, add PU METER at the end. Example: PUSG-17B.31
NEW!
NEW!
NEW!
NEW!
www.tnb.ca E25
Nylon Flexible Conduit Systems
PMA ®
VUS Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended bending
radius for static (fixed) instal-
lation.
Conduits
VUS Flexible, Heavy
Meet high requirements in machine building
and plant construction
Use where high compression resistance is
required
Great for external applications
High-grade, specially modified polyamide 6
Very good resistance to ultraviolet rays and
weathering
Good flexibility and self-extinguishing
High mechanical strength at low
temperatures and low humidity
Free from halogens and cadmium
Temperature range: -50° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
VUSG-17B VUSG-17S
17 20 15.2 21.2 40
31
VUSG-23B VUSG-23S
23 25 22.0 28.5 50
VUSG-29B VUSG-29S
29 32 27.7 34.4 60
VUSG-36B VUSG-36S
36 40 35.8 42.4 70
VUSG-48B VUSG-48S
48 50 46.8 54.4 80
For actual cat. number, add PU METER at the end. Example: VUSG-17B.31
NEW!
NEW!
www.tnb.ca
E26
Nylon Flexible Conduit Systems
PMA ®
PMAFIX® Connector Series
BVND-P167GT/01
B V N D - P 16 7GT/ 01
Colours PMAFIX
®
Type
PMAFIX
®
Series
Mode of Ingress Protection
(page E76)
Code of Thread
(page E77)
Side of
Thread
(Table 2)
Nominal Width
PMAFLEX
®
(Table 1)
Safety
Retaining Clip Type
Modification
Code
B = Black
S = Grey
N = Black with Metal Thread
M = Grey with Metal Thread
A = Black – Anthracite
T = Transparent
X = Special Colour
V = Reinforced
S = Series V with
Swiveling
Coupler
E = Ex Certified
N = Straight
W = 90° Elbow
B = 90° Curved Elbow
A = 45° Elbow
O = 90° Elbow with Flange
I = With Female Thread
Y = Y Piece
T = T Piece
V = V Piece
D = Self-Sealing IP66
L = With Seal Cap IP67 on Conduit
R = With Seal Cap IP68 on Conduit
V = With Gasket-Reinforced IP68
Z = Add. combined Sealing with
Strain Relief IP50/IP68
P = PG Thread
M = Metric Thread
F = Metric Fine Thread
N = NPT Thread (USA)
G = Gas Thread (Italy)
U = UNEF Round
Connector
(See p. E27) 7 = Nominal-Width
Conduit
(See p. E27)
GT = Universal Safety
.. = Oval Clip
Series VSeries TSeries YSeries I
Series A Series BSeries WSeries N
Series O
PMAFIX® Fittings
www.tnb.ca E27
Nylon Flexible Conduit Systems
PMA ®
Table 1
PMAFIX®/PMAFLEX® Code
Normal
Width
UK
Sizes
PMA
Code
710 M
10 12 0
12 16 2
17 20 7
23 25 3
29 32 9
36 40 6
48 50 8
Types of Connector for
Female Thread Adapters
Type PMA
Code
AMP A
Souriau (ex BURNDY) B
With O-Ring Groove (MIL C 5015) G
Table 2
Thread Codes
Thread
Metric
PMA
Code Thread PG PMA
Code
Thread
Gas (in.)
PMA
Code
Thread
NPT (in.)
PMA
Code
Thread
UNEF
PMA
Code
M12x1.5 M12 PG07 P07 G 1/4 G00 3/8-28 UNEF U09
M16x1.5 M16 PG09 P09 G 3/8 G01 7/16-28 UNEF U10
M20x1.5 M20 PG11 P11 G 1/2 G02 N 1/2 N02 1/2-28 UNEF U12
PG13.5 P13 G 3/4 G04 N 3/4 N04 9/16-24 UNEF U13
M25x1.5 M25 PG16 P16 G 1 G06 N 1 N06 5/8-24 UNEF U15
M32x1.5 M32 PG21 P21 G 1-1/4 G07 N 1-1/4 N07 11/16-24 UNEF U16
M40x1.5 M40 PG29 P29 G 1-1/2 G08 N 1-1/2 N08 3/4-20 UNEF U18
M50x1.5 M50 PG36 P36 G 2 G09 N 2 N09 13/16-20 UNEF U20
M63x1.5 M63 PG42 P42 G 2-1/4 G10 7/8-20 UNEF U21
PG48 P48 G 2-1/2 G11 15/16-20 UNEF U23
1-20 UNEF U24
M 8x1.0 F08 1-1/16-18 UNEF U26
M12x1.0 F12 1-3/16-18 UNEF U29
M18x1.0 F18 1-1/4-18 UNEF U30
M30x1.5 F30 1-5/16-18 UNEF U32
1-3/8-18 UNEF U34
1-7/16-18 UNEF U35
1-5/8-18 UNEF U40
1-11/16-20 UN U41
1-3/4-18 UNS U43
2-18 UNS U50
2-1/4-16 UN U56
2-3/8-12 UN U57
2-1/2-16 UN U62
Threaded Codes
www.tnb.ca
E28
Nylon Flexible Conduit Systems
PMA ®
IP66 — IP66 Static, IP54 Dynamic
One-piece fitting
Conical sealing method
Easy push-in installation
Pre-installed safety clip AFN2
Fits any type of conduit profile (T and G)
Excellent pullout strength
Re-opening only possible with a screwdriver for safety reasons
IP68GT — IP68 static, IP67 dynamic, IP69K
Single-piece PMAFIX® IP68GT fitting with integrated sealing cap
and pre-installed locking clip
Simple push-in assembly (as with the proven
PMAFIX® IP66 system)
Extra-long sealing cap guarantees the highest
level of ingress protection
Compatible with all types of PMA® conduits
Identical approvals as with the PMAFIX® IP68 system
The complete PMAFIX® IP68 product range is available
as a GT single-component version
Fast modification of specification drawings through
simple addition of “GT” to the existing order number
(e.g. BVNV-M257 becomes BVNV-M257GT)
IP68 — IP68 static, IP67 dynamic, IP69K
High sealing through additional seal cap
For highest dynamic appli cations
Fits any type of conduit profile (T and G)
Excellent pullout strength
Re-opening only possible with a screwdriver for safety reasons
Additional water-protection ring WPS for IP69K ingress
protection in conjunction with the IP68 system
To be applied right after the IP68 connector onto the conduit
IP69K
Connectors for Nylon Flexible Conduits
PMAFIX® Connector Safety and Sealing Systems
NEW!
NEW!
www.tnb.ca E29
Nylon Flexible Conduit Systems
PMA ®
Push in conduit
with a slight twist.
(Open using screw-
driver on conduit
side.)
Pull back slightly
to ensure the
locking mechanism
is fully engaged.
To re-open, use
a screwdriver.
Locking clip pre-installed in all IP66 connectors
IP68GT Installation
(A) Conduit
(B) Connector
(pre-installed sealing
cap and locking clip)
(C) Flat Gasket or
O-ring
Push in conduit
with a slight twist.
PUll back slightly to
ensure the locking
mechanism is fully
engaged.
To re-open, use
a screwdriver.
Pre-installed sealing cap and locking clip in all IP68GT connectors
For safety reasons, oval clip will not fit if seal cap is not fully installed.
Follow O-ring manufacturer’s guidelines when using O-rings for sealing purposes.
IP68 Installation (IP69K)
(A) Conduit
(B) Seal Cap
(C) Connector
(D) Oval Clip
(E) Flat Gasket
(or O-ring seal)
Push seal cap onto
end of conduit to
achieve IP68. For
ease of installa-
tion, moisten seal
cap with water or
grease.
Push conduit with
seal cap fully into
connector. This
guarantees PMAs
unique IP68/67
rating.*
Install retaining
oval clip.
To re-open, use
a screwdriver.
Mount WPS half
shells at the base
of the connector
onto the conduit.
* For safety reasons, oval clip will not fit if seal cap is not fully installed.
Follow O-ring manufacturer’s guidelines when using O-rings for sealing purposes.
123
123
12 3
456
A
B
C
A
B
C
D
E
Connectors for Nylon Flexible Conduits
IP66 Installation
www.tnb.ca
E30
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
G
Thread Length
A
Overall Length
G
Thread Length
A
Overall Length
G
Thread Length
A x B
External
dimensions
G
Thread Length
A x B
External
dimensions
G
Thread Length
A x B
External
dimensions
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VND-M12MGT _VNV-M12M
M12x1.5 710
11.0
34.5
_VND-M120GT _VNV-M120
10 12 36.5
_VND-M160GT _VNV-M160
M16x1.5 36.5
_VND-M162GT _VNV-M162
12 16 39.5
_VND-M200GT _VNV-M200
M20x1.5
10 12 36.5
_VND-M202GT _VNV-M202
12 16 39.5
_VND-M207GT _VNV-M207
17 20 47.5
_VND-M203GT _VNV-M203
23 25 51.0
_VND-M257GT _VNV-M257
M25x1.5 17 20 12.0 48.5
_VND-M253GT _VNV-M253
23 25 52.0
_VND-M323GT _VNV-M323
M32x1.5 15.0 55.5
_VND-M329GT _VNV-M329
29 32 56.0
_VND-M409GT _VNV-M409
M40x1.5
19.0
60.0
_VND-M406GT _VNV-M406
36 40 72.5
_VND-M506GT _VNV-M506
M50x1.5 72.0
_VND-M508GT _VNV-M508
48 50 72.5
_VND-M638GT _VNV-M638
M63x1.5 72.0
For cable protection systems in a wide range
of applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Vibration-proof connection to
PMAFLEX
®
conduits
Easy mounting: simple conduit
push-in installation
High conduit pullout strength
Can be easily re-opened with a screwdriver
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
The designation PMAFIX® describes a very large range of fittings for PMA conduits with the paten ted PMA®
safety clip system. Fittings are available for ingress protection IP66 and IP68. IP66 fittings are fitted with
a pre- installed universal safety clip that ensu res a quick push-in installation. IP68 fittings for increased
requirements will be delivered with a special conduit seal cap. The new PMAFIX IP68GT fittings combine
simplest push-in assembly with highest sealing performance.
A
GG
G
G
G
A
A
B
B
B
A
A
Fittings for Nylon Flexible Conduits
VN Straight, Metric, Polymide
www.tnb.ca E31
Nylon Flexible Conduit Systems
PMA ®
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VAD-M120GT
M12x1.5 10 12
11.0
43.5 x 37.0
_VAD-M160GT _VAV-M160
M16x1.5 43.5 x 38.0
_VAD-M162GT _VAV-M162
12 16 48.0 x 40.0
_VAD-M202GT _VAV-M202
M20x1.5 48.0 x 41.5
_VAD-M207GT _VAV-M207
17 20 55.5 x 51.5
_VAD-M253GT _VAV-M253
M25x1.5 23 25 12.0 65.0 x 58.5
_VAD-M329GT _VAV-M329
M32x1.5 29 32 15.0 73.5 x 66.5
_VAD-M406GT _VAV-M406
M40x1.5 36 40
19.0
92.5 x 85.5
_VAD-M506GT _VAV-M506
M50x1.5 92.5 x 89.5
_VAD-M508GT _VAV-M508
48 50 100.0 x 96.0
_VAD-M638GT _VAV-M638
M63x1.5 100.0 x 104.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Terminal
Range (mm)
Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VNDZ-M160GT
M16x1.5 10 12 5.0–10.0
8.0
62.0
_VNDZ-M162GT _VNZ-M162S
12 16
_VNDZ-M207GT _VNZ-M207S
M20x1.5 17 20 10.0–14.0 71.5
_VNDZ-M253GT _VNZ-M253S
M25x1.5 23 25 13.0–18.0 81.0
_VNDZ-M329GT _VNZ-M329S
M32x1.5 29 32 18.0–25.0 10.0 85.0
_VNDZ-M406GT _VNZ-M406S
M40x1.5 36 40 22.0–32.0 116.5
_VNDZ-M508GT _VNZ-M508S
M50x1.5 48 50 30.0–38.0 12.0 120.5
_VNDZ-M638GT _VNZ-M638S
M63x1.5 48 50 34.0–44.0
_ = Insert “B” to order black or “S” to order grey.
Note: MDE multiple sealing inserts are available for this product.
IP68GT available. Please replace final “S” with “GT.
(Functional description PMAFIX IP68GT, pages E28E29).
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2), strain-relief insert
IP68GT: Fitting with pre-assembled univer-
sal clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2),
strain-relief insert, conduit and thread
seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seals (NVN3, SVN4)
For cable protection systems in a wide
range of applications
For separation of damp and dry areas
High-grade formulated polyamide 6,
very high impact resistance
Easy installation: simply push
the conduit in
High conduit pullout strength
Integrated strain relief optimally holds
and seals cables
If several conductors are used with the
connector, multiple sealing inserts should
be considered
Very good chemical properties,
free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
VA 45° Elbow, Metric, Polyamide
For cable protection systems in a wide
range of applications
High-grade specially formulated
polyamide 6
Extremely high impact resistance
Vibration-proof connection to
PMAFLEX
®
conduits
Easy installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Fittings for Nylon Flexible Conduits
VNZ Straight, Metric, Strain Relief, Polyamide
www.tnb.ca
E32
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide
range of applications
High-grade specially formulated polyamide
Easy installation, high conduit
pull-out strength
Easy threading of wires and cables
Self extinguishing
Free from halogens and phosphor
Excellent impact strength
Fits fine (T) and coarse (G) conduit profiles
VW 90° Elbow, Metric, Polyamide
For cable protection systems in a
wide range of applications
High-grade specially formulated
polyamide 6
Very high impact resistance
Vibration-proof connection to
PMAFLEX® conduits
Easy installation: simply push the conduit in
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VBD-M207GT _VBV-M207
M20x1.5 17 20 11.0 47.5 x 73.0
_VBD-M257GT _VBV-M257
M25x1.5 12.0 48.5 x 76.0
_VBD-M253GT _VBV-M253
23 25 57.5 x 83.0
_VBD-M323GT _VBV-M323
M32x1.5 15.0 61.0 x 87.5
_VBD-M329GT _VBV-M329
29 32 70.5 x 93.0
_VBD-M409GT _VBV-M409
M40x1.5
19.0
74.5 x 98.5
_VBD-M406GT _VBV-M406
36 40 85.0 x 121.0
_VBD-M506GT _VBV-M506
M50x1.5 85.0 x 125.0
_VBD-M508GT _VBV-M508
48 50 98.5 x 130.0
_VBD-M638GT _VBV-M638
M63x1.5 98.5 x 138.0
_ = Insert with “B” to order black or “S” to order grey.
For smaller conduit sizes NW 07 to NW 12, appropriate standard elbows of type VW are available.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, (pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VWD-M12MGT _VWV-M12M
M12x1.5 710
11.0
32.0 x 35.0
_VWD-M120GT _VWV-M120
10 12 34.0 x 39.5
_VWD-M160GT _VWV-M160
M16x1.5 34.0 x 40.5
_VWD-M162GT _VWV-M162
12 16 38.5 x 46.0
_VWD-M200GT
M20x1.5
10 12 34.0 x 42.5
_VWD-M202GT _VWV-M202
12 16 38.5 x 47.5
_VWD-M207GT _VWV-M207
17 20 43.5 x 58.5
_VWD-M253GT _VWV-M253
M25x1.5 23 25 12.0 54.0 x 65.0
_VWD-M329GT _VWV-M329
M32x1.5 29 29 15.0 64.5 x 73.0
_VWD-M406GT _VWV-M406
M40x1.5 36 36 19.0 78.0 x 96.0
_VWD-M508GT _VWV-M508
M50x1.5 48 48 91.5 x 106.0
_ = Insert with “B” to order black or “S” to order grey.
For the sizes NW 17 to NW 48, curved elbows of type VB are available.
IP68GT available. Please add “GT” after the Catallog no.
(Functional description PMAFIX IP68GT, (pages E28E29).
Fittings for Nylon Flexible Conduits
VB 90° Curved Elbow, Metric, Polyamide
www.tnb.ca E33
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4 or OR)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4 or OR)
Use in railway vehicle and heavy
machine construction
High-grade specially formulated polyamide,
thread made of nickel-plated brass
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66, Black
Cat. No.
IP68, Grey
Thread
Metric
Fits to Conduit Thread
Length (mm)
Overall
Length (mm)
NW Metric
NVNV-M120-10 MVNV-M120-10
M12x1.5
10 12
10.0 40.0
NVNV-M120-5 MVNV-M120-5
5.0 35.0
NVNV-M160-10 MVNV-M160-10
M16x1.5
10.0 40.0
NVNV-M160-5 MVNV-M160-5
5.0 35.0
NVNV-M162-10 MVNV-M162-10
12 16
10.0 43.0
NVNV-M162-5 MVNV-M162-5
5.0 38.0
NVNV-M202-10 MVNV-M202-10
M20x1.5
10.0 43.0
NVNV-M202-6 MVNV-M202-6
6.0 39.0
NVNV-M207-10 MVNV-M207-10
17 20
10.0 51.0
NVNV-M207-6 MVNV-M207-6
6.0 47.0
NVNV-M257-11 MVNV-M257-11
M25x1.5
11.0 52.0
NVNV-M257-7 MVNV-M257-7
7.0 48.0
NVNV-M253-11 MVNV-M253-11
23 25
11.0 54.0
NVNV-M253-7 MVNV-M253-7
7.0 50.0
NVNV-M323-13 MVNV-M323-13
M32x1.5
13.0 56.0
NVNV-M323-8 MVNV-M323-8
8.0 51.0
NVNV-M329-13 MVNV-M329-13
29 32
13.0 57.3
NVNV-M329-8 MVNV-M329-8
8.0 52.3
NVNV-M409-13 MVNV-M409-13
M40x1.5
13.0 57.3
NVNV-M409-8 MVNV-M409-8
8.0 52.3
NVNV-M406-13 MVNV-M406-13
36 40
13.0 71.4
NVNV-M406-8 MVNV-M406-8
8.0 66.4
NVNV-M506-14 MVNV-M506-14
M50x1.5
14.0 72.4
NVNV-M506-9 MVNV-M506-9
9.0 67.4
NVNV-M508-14 MVNV-M508-14
48 50
14.0 72.4
NVNV-M508-9 MVNV-M508-9
9.0 67.4
NVNV-M638-14 MVNV-M638-14
M63x1.5 14.0 72.4
IP68GT available. Please add “GT” prior to the thread length (for example, NVNV-M120GT-10).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VN Straight, Metric, Metal
www.tnb.ca
E34
Nylon Flexible Conduit Systems
PMA ®
Use in railway vehicle and heavy machine
construction and for the separation of damp
and dry areas
High-grade, specially formulated polyamide
6, thread made of nickel-plate brass,
sealing inserts are made from TPE-V
Very high impact resistance
Integrated strain relief and optimal ingress
protection at the cable (up to IP68/10 bar)
High thread and system connection strength
Vibration-resistant connection to
PMAFLEX® conduits
Easy assembly
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Excellent impact strength
Fits fine (T) and coarse (G) conduit profiles
For several conductors, multiple sealing
inserts are available (MDE)
Temperature range: -40° C to 105° C;
Short term to 135° C
Content of delivery:
IP68GT:
Complete: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); sealing insert, O-ring (OR)
Fitting*: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); O-ring (OR)
IP68:
Complete: Fitting with oval clips (OVN2),
sealing insert, conduit seal
(NVN3), O-ring (OR)
Fitting*: Fitting with oval clips (OVN2),
conduit seal (NVN3), O-ring (OR)
Cat. No.
Complete,
Black
Cat. No.
Fitting *
Cat. No.
Insert
Thread
Metric
Fits to Conduit Size Terminal
Range (mm)
Thread
Length
(mm)
Overall
Length
(mm)
NW Metric
NVNZ-M120S/P1 NVNZ-M120R/P DE-M120/P1
M12x1.5
10 12
4.0–6.5
5.0 48.5
NVNZ-M120S/P2 DE-M120/P2
5.0–8.0
NVNZ-M120S/P3 DE-M120/P3
6.5–9.5
NVNZ-M160S/P1 NVNZ-M160R/P DE-M160/P1
M16x1.5
4.0–6.5
6.0
49.5
NVNZ-M160S/P2 DE-M160/P2
5.0–8.0
NVNZ-M160S/P3 DE-M160/P3
6.5–9.5
NVNZ-M202S/P1 NVNZ-M202R/P DE-M202/P1
M20x1.5
12 16
4.0–6.5
54.0
NVNZ-M202S/P3 DE-M202/P3
6.5–9.5
NVNZ-M202S/P4 DE-M202/P4
7.0–10.5
NVNZ-M207S/P3 NVNZ-M207R/P DE-M207/P3
17 20
6.5–9.5
6.5 60.0
NVNZ-M207S/P4 DE-M207/P4
7.0–10.5
NVNZ-M207S/P5 DE-M207/P5
9.0–13.0
NVNZ-M253S/P5 NVNZ-M253R/P DE-M253/P5
M25x1.5
23 25 9.0–13.0
7.5
72.5
NVNZ-M253S/P6 DE-M253/P6
11.5–15.5
NVNZ-M257S/P4 NVNZ-M257R/P DE-M257/P4
17 20
7.0–10.0
61.5
NVNZ-M257S/P5 DE-M257/P5
9.0–13.0
NVNZ-M257S/P6 DE-M257/P6
11.5–15.5
NVNZ-M323S/P4 NVNZ-M323R/P DE-M323/P4
M32x1.5
23 25 14.0–18.0
8.0 73.0
NVNZ-M323S/P5 NVNZ-M323R1/P DE-M323/P5
17.0–20.5
NVNZ-M329S/P2 NVNZ-M329R/P DE-M329/P2
29 32
14.0–18.0
NVNZ-M329S/P3 DE-M329/P3
17.0–20.5
NVNZ-M329S/P4 DE-M329/P4
20.0–25.0
NVNZ-M406S/P1 NVNZ-M406R/P DE-M406/P1
M40x1.5
36 40 20.0–25.0 9.0 87.0
NVNZ-M406S/P2 DE-M406/P2
24.0–28.0
NVNZ-M409S/P1 NVNZ-M409R/P DE-M409/P1
29 32
11.5–15.5
8.0 73.0
NVNZ-M409S/P2 DE-M409/P2
14.0–18.0
NVNZ-M409S/P3 DE-M409/P3
17.0–20.5
NVNZ-M409S/P4 DE-M409/P4
20.0–25.0
NVNZ-M409S/P5 DE-M409/P5
24.0–28.0
NVNZ-M506S/P1 NVNZ-M506R/P DE-M506/P1
M50x1.5
36 40 27.0–32.0
9.0
89.5
NVNZ-M506S/P3 DE-M506/P3
32.0–36.0
NVNZ-M508S/P2 NVNZ-M508R/P DE-M508/P2
48 50
32.0–36.0 92.0
NVNZ-M508S/P3 DE-M508/P3
36.0–40.0
NVNZ-M638S/P1 NVNZ-M638R/P DE-M638/P1
M63x1.5 35.0–40.0 10.0 90.5
NVNZ-M638S/P2 DE-M638/P2
39.0–44.0
* = without insert
Note: MDE multiple sealing inserts are available for this product.
IP68GT available. Please replace “S” or “R” with “GT” (for example, NVNZ-M120GT/P1, NVNZ-M120GT/P).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VNZ Straight, Metric, Strain Relief, Metal
www.tnb.ca E35
Nylon Flexible Conduit Systems
PMA ®
Cat. No.
Complete,
Black
Cat. No.
Fitting *
Cat. No.
Insert
Thread
Metric
Fits to Conduit
Size Terminal
Range
(mm)
Thread
Length
(mm)
Overall
Length
(mm)
NW Metric
NVNZ-M160S/P1-L NVNZ-M160R/P-L DE-M160/P1
M16x1.5 10 12
4.0–6.5
15.0
58.5
NVNZ-M160S/P2-L DE-M160/P2
5.0–8.0
NVNZ-M160S/P3-L DE-M160/P3
6.5–9.5
NVNZ-M202S/P1-L NVNZ-M202R/P-L DE-M202/P1
M20x1.5
12 16
4.0–6.5
62.5
NVNZ-M202S/P3-L DE-M202/P3
6.5–9.5
NVNZ-M202S/P4-L DE-M202/P4
7.0–10.5
NVNZ-M207S/P3-L NVNZ-M207R/P-L DE-M207/P3
17 20
6.5–9.5
68.5
NVNZ-M207S/P4-L DE-M207/P4
7.0–10.5
NVNZ-M207S/P5-L DE-M207/P5
9.0–13.0
NVNZ-M257S/P5-L NVNZ-M257R/P-L DE-M257/P5
M25x1.5 9.0–13.0 69.0
NVNZ-M257S/P6-L DE-M257/P6
11.5–15.5
NVNZ-M323S/P4-L NVNZ-M323R/P-L DE-M323/P4
M32x1.5
23 25 14.0–18.0 80.0
NVNZ-M323S/P5-L NVNZ-M323R1/P-L DE-M323/P5
17.0–20.5
NVNZ-M329S/P2-L NVNZ-M329R/P-L DE-M329/P2
29 32
14.0–18.0 91.0
NVNZ-M329S/P3-L DE-M329/P3
17.0–20.5
NVNZ-M409S/P3-L NVNZ-M409R/P-L DE-M409/P3
M40x1.5
17.0–20.5
80.0
NVNZ-M409S/P4-L DE-M409/P4
20.0–25.0
NVNZ-M409S/P5-L DE-M409/P5
24.0–28.0
NVNZ-M506S/P1-L NVNZ-M506R/P-L DE-M506/P1
M50x1.5
36 40 27.0–32.0 94.5
NVNZ-M506S/P3-L DE-M506/P3
32.0–36.0
NVNZ-M508S/P2-L NVNZ-M508R/P-L DE-M508/P2
48 50
32.0–36.0 97.0
NVNZ-M508S/P3-L DE-M508/P3
36.0–40.0
NVNZ-M638S/P1-L NVNZ-M638R/P-L DE-M638/P1
M63x1.5 35.0–40.0 95.5
NVNZ-M638S/P2-L DE-M638/P2
39.0–44.0
* = without insert
Note: MDE multiple sealing inserts are available for this product.
IP68GT available. Please replace “S” or “R” with “GT” (for example, NVNZ-M120GT/P1).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VNZ Straight, Metric, Strain Relief, Metal (cont’d)
www.tnb.ca
E36
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3GT); thread seal (SVN4 or OR)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4 or OR)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4 or OR)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4 or OR)
VB 90° Curved Elbow, Metric, Metal
Use in railway vehicle and heavy machine
construction
High-grade formulated polyamide, thread
made of nickel-plated brass
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVBV-M207-10 MVBV-M207-10
M20x1.5
17 20
10.0 51.0 x 73.0
NVBV-M207-6 MVBV-M207-6
6.0 47.0 x 73.0
NVBV-M257-11 MVBV-M257-11
M25x1.5
11.0 52.0 x 76.0
NVBV-M257-7 MVBV-M257-7
7.0 48.0 x 76.0
NVBV-M253-11 MVBV-M253-11
23 25
11.0 62.5 x 85.0
NVBV-M253-7 MVBV-M253-7
7.0 58.5 x 85.0
NVBV-M323-13 MVBV-M323-13
M32x1.5
13.0 64.5 x 89.0
NVBV-M323-8 MVBV-M323-8
8.0 59.5 x 89.0
NVBV-M329-13 MVBV-M329-13
29 32
13.0 74.0 x 94.5
NVBV-M329-8 MVBV-M329-8
8.0 69.0 x 94.5
NVBV-M409-13 MVBV-M409-13
M40x1.5
13.0 75.5 x 100.5
NVBV-M409-8 MVBV-M409-8
8.0 70.5 x 100.5
NVBV-M406-13 MVBV-M406-13
36 40
13.0 86.5 x 123.0
NVBV-M406-8 MVBV-M406-8
8.0 81.5 x 123.0
NVBV-M506-14 MVBV-M506-14
M50x1.5
14.0 87.5 x 130.0
NVBV-M506-9 MVBV-M506-9
9.0 82.5 x 130.0
NVBV-M508-14 MVBV-M508-14
48 50
14.0 100.5 x 135.0
NVBV-M508-9 MVBV-M508-9
9.0 95.5 x 135.0
NVBV-M638-10 MVBV-M638-10
M63x1.5 14.0 100.5 x 138.0
NVBV-M638-14 MVBV-M638-14
10.0 96.5 x 138.0
Appropriate standard elbows of type VW are available for smaller conduit sizes NW 10 to NW 12.
IP68GT available. Please add “GT” prior to the thread length (e.g. NVBV-M207GT-10).
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVAV-M120-10 MVAV-M120-10
M12x1.5 10 12 10.0 48.5 x 37.0
NVAV-M120-5 MVAV-M120-5
5.0 43.5 x 37.0
NVAV-M162-10 MVAV-M162-10
M16x1.5 12 16 10.0 53.0 x 40.5
NVAV-M162-5 MVAV-M162-5
5.0 48.0 x 40.5
NVAV-M207-10 MVAV-M207-10
M20x1.5 17 20 10.0 60.5 x 51.5
NVAV-M207-6 MVAV-M207-6
6.0 56.5 x 51.5
NVAV-M253-11 MVAV-M253-11
M25x1.5 23 25 11.0 70.0 x 60.5
NVAV-M253-7 MVAV-M253-7
7.0 66.0 x 60.5
NVAV-M257-11 MVAV-M257-11
17 20 11.0 61.5 x 54.5
NVAV-M323-13 MVAV-M323-13
M32x1.5
23 25 13.0 72.0 x 64.5
NVAV-M329-13 MVAV-M329-13
29 32 13.0 77.0 x 68.0
NVAV-M329-8 MVAV-M329-8
8.0 72.0 x 68.0
NVAV-M406-13 MVAV-M406-13
M40x1.5 36 40 13.0 94.0 x 87.5
NVAV-M406-8 MVAV-M406-8
8.0 89.0 x 87.5
NVAV-M409-13 MVAV-M409-13
29 32 13.0 77.0 x 73.0
NVAV-M506-14 MVAV-M506-14
M50x1.5
36 40 14.0 95.0 x 92.5
NVAV-M508-14 MVAV-M508-14
48 50
14.0 102.0 x 101.0
NVAV-M508-9 MVAV-M508-9
9.0 97.0 x 101.0
NVAV-M638-14 MVAV-M638-14
M63x1.5 14.0 102.0 x 104.0
NVAV-M638-10 MVAV-M638-10
10.0 98.0 x 104.0
IP68GT available. Please add “GT” prior to the thread length (e.g. NVAV-M120GT-10).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VA 45° Elbow, Metric, Metal
Use in railway vehicle and heavy machine construc-
tion
Specially formulated polyamide 6, nickel-plated
brass thread
Very high impact resistance
High thread and system connection strength
Vibration-proof connection to PMAFLEX® conduits
Easy assembly
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
www.tnb.ca E37
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4 or OR)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4 or OR)
Use in railway vehicle and heavy machine
construction
High-grade formulated polyamide, thread
made of nickel-plated brass
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Fits fine (T) and coarse
(G) conduit profiles
VWZ 90° Elbow, Metric, Strain Relief, Metal
Use in railway vehicle construction and
heavy machine construction
Separate damp and dry areas
High-grade formulated polyamide PA straight
fitting with nickel-plated brass female
thread, zinc diecast (90° elbow), sealing
insert TPE-V
With corresponding seals, IP68 static/IP67
dynamic cable = IP68 (10 bar)
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVWV-M120-10 MVWV-M120-10
M12x1.5
10 12
10.0 37.5 x 39.5
NVWV-M120-5 MVWV-M120-5
5.0 32.5 x 39.5
NVWV-M160-10 MVWV-M160-10
M16x1.5
10.0 37.5 x 41.5
NVWV-M160-5 MVWV-M160-5
5.0 32.5 x 41.5
NVWV-M162-10 MVWV-M162-10
12 16
10.0 42.0 x 46.5
NVWV-M162-5 MVWV-M162-5
5.0 37.0 x 46.5
NVWV-M202-10 MVWV-M202-10
M20x1.5
10.0 42.0 x 49.0
NVWV-M202-6 MVWV-M202-6
6.0 38.0 x 49.0
NVWV-M207-10 MVWV-M207-10
17 20 10.0 47.0 x 58.5
NVWV-M207-6 MVWV-M207-6
6.0 43.0 x 58.5
NVWV-M253-11 MVWV-M253-11
M25x1.5 23 25 11.0 59.0 x 67.0
NVWV-M253-7 MVWV-M253-7
7.0 55.0 x 67.0
NVWV-M329-13 MVWV-M329-13
M32x1.5 29 32 13.0 68.0 x 74.5
NVWV-M329-8 MVWV-M329-8
8.0 63.0 x 74.5
NVWV-M406-13 MVWV-M406-13
M40x1.5 36 40 13.0 80.5 x 98.0
NVWV-M406-8 MVWV-M406-8
8.0 75.5 x 98.0
NVWV-M508-14 MVWV-M508-14
M50x1.5
48 50
14.0 95.5 x 111.0
NVWV-M508-9 MVWV-M508-9
9.0 90.5 x 111.0
NVWV-M638-14 MVWV-M638-14
M63x1.5 14.0 94.5 x 114.0
NVWV-M638-10 MVWV-M638-10
10.0 90.5 x 114.0
IP68GT available. Please add “GT” prior to the thread length (e.g. NVWV-M120GT-10).
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No. IP68
Complete, Black
Cat. No.
Fitting *
Cat. No.
Insert
Thread
Metric
Fits to Conduit Size Terminal
Range (mm)
Thread
Length
(mm)
Overall
Length
(mm)
NW Metric
NVWZ-M160S/P1 NVWZ-M160R/P DE-M160/P1
M16x1.5 10 12
4.0–6.5
8.0
65.0
NVWZ-M160S/P2 DE-M160/P2
5.0–8.0
NVWZ-M160S/P3 DE-M160/P3
6.5–9.5
NVWZ-M202S/P1 NVWZ-M202R/P DE-M202/P1
M20x1.5
12 16
4.0–6.5
74.5
NVWZ-M202S/P3 DE-M202/P3
6.5–9.5
NVWZ-M202S/P4 DE-M202/P4
7.0–10.5
NVWZ-M207S/P3 NVWZ-M207R/P DE-M207/P3
17 20
6.5–9.5
81.0
NVWZ-M207S/P4 DE-M207/P4
7.0–10.5
NVWZ-M207S/P5 DE-M207/P5
9.0–13.0
NVWZ-M257S/P5 NVWZ-M257R/P DE-M257/P5
M25x1.5 9.0–13.0 84.0
NVWZ-M257S/P6 DE-M257/P6
11.5–15.5
* = without insert
IP68GT available. Please replace “S” with “GT” (for example NVWZ-M160GT/P1).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VW 90° Elbow, Metric, Metal
Temperature range: -40° C to 105° C;
Short term to 135° C
Content of delivery:
IP68GT:
Complete: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); sealing insert, O-ring (OR)
Fitting*: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); O-ring (OR)
IP68:
Complete: Fitting with oval clips (OVN2), sealing
insert, conduit seal (NVN3), O-ring (OR)
Fitting*: Fitting with oval clips (OVN2), conduit
seal (NVN3), O-ring (OR)
www.tnb.ca
E38
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP68
Cat. No.
IP68
Thread
PG
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VND-P07MGT-11 _VNV-P07M
7
710 11.0 34.5
_VND-P07MGT-8
8.0 31.5
_VND-P070GT-11 _VNV-P070
10 12 11.0 36.5
_VND-P070GT-8
8.0 33.5
_VND-P072GT-11 _VNV-P072
12 16 11.0 39.0
_VND-P072GT-8
8.0 36.0
_VND-P09MGT-11 _VNV-P09M
9
7 10 11.0 34.5
_VND-P09MGT-8
10 12
8.0 31.5
_VND-P090GT-11 _VNV-P090
11.0 36.5
_VND-P090GT-8
8.0 33.5
_VND-P092GT-11 _VNV-P092
12 16 11.0 39.0
_VND-P092GT-8
8.0 36.0
_VND-P097GT-11 _VNV-P097
17 20 11.0 47.5
_VND-P097GT-8
8.0 44.5
_VND-P11MGT-11 _VNV-P11M
11
7 10 11.0 34.5
_VND-P11MGT-8
8.0 31.5
_VND-P110GT-11 _VNV-P110
10 12 11.0 36.5
_VND-P110GT-8
8.0 33.5
_VND-P112GT-11 _VNV-P112
12 16 11.0 39.0
_VND-P112GT-8
8.0 36.0
_VND-P117GT-11 _VNV-P117
17 20 11.0 47.5
_VND-P117GT-8
8.0 44.5
_VND-P13MGT-11 _VNV-P13M
 13.5
7 10 11.0 34.5
_VND-P13MGT-8
8.0 31.5
_VND-P130GT-11 _VNV-P130
10 12 11.0 36.5
_VND-P130GT-8
8.0 33.5
_VND-P132GT-11 _VNV-P132
12 16 11.0 39.0
_VND-P132GT-8
8.0 36.0
_VND-P137GT-11 _VNV-P137
17 20 11.0 47.5
_VND-P137GT-8
8.0 44.0
_VND-P160GT-11
16
10 12 11.0 36.5
_VND-P160GT-8
8.0 33.5
_VND-P162GT-11 _VNV-P162
12 16 11.0 39.0
_VND-P163GT-11 _VNV-P163
23 25 11.0 51.5
_VND-P163GT-8
8.0 48.0
_VND-P167GT-11 _VNV-P167
17 20 11.0 47.5
_VND-P167GT-8
8.0 44.5
_VND-P213GT _VNV-P213
21 23 25
12.0
52.0
_VND-P296GT _VNV-P296
29 36 40 67.5
_VND-P299GT _VNV-P299
29 32 53.0
_VND-P366GT _VNV-P366
36 36 40
13.0
66.0
_VND-P368GT _VNV-P368
36
48 50 68.5
_VND-P428GT _VNV-P428
42
_VND-P488GT _VNV-P488
48
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VN Straight, PG, Polyamide
www.tnb.ca E39
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); strain-relief insert and
thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), strain-
relief insert, conduit and thread seal
(NVN3, SVN4)
For several conductors, multiple sealing inserts
are available (MDE)
For cable protection systems in a wide range
of applications
Separate damp and dry areas
High-grade, specially formulated polyamide 6
Very high impact resistance, high conduit
pullout strength
Easy mounting: simple push-in installation
Integrated strain relief optimally holds and
seals cables
If several conductors are used with the
connector, multiple sealing inserts should
be considered
Very good chemical properties
Free from halogens and cadmium
Excellent impact strength
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
Metric
Fits to Conduit Terminal
Range (mm)
Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VNDZ-P090GT _VNZ-P090S
910 12 4.0–8.0 8.0 53.0
_VNDZ-P112GT _VNZ-P112S
11 12 16 5.0–10.0 59.0
_VNDZ-P132GT _VNZ-P132S
13.5 6.0–12.0 9.0 62.0
_VNDZ-P137GT _VNZ-P137S
13.5 17 20 69.0
_VNDZ-P167GT _VNZ-P167S
16 10.0–14.0 10.0 72.0
_VNDZ-P163GT _VNZ-P163S
16 23 25 12.0 79.0
_VNDZ-P213GT _VNZ-P213S
21 13.0–18.0 82.0
_VNDZ-P299GT _VNZ-P299S
29 29 32 18.0–25.0 11.0 85.0
_ = Insert “B” to order black or “S” to order grey.
Note: MDE multiple sealing inserts are available for this product.
IP68GT available. Please replace “S” at the end with “GT” (for example, BVNZ-P112GT/P1).
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VNZ Straight, PG, Strain Relief, Polyamide
www.tnb.ca
E40
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide
range of applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
VB 90° Curved Elbow, PG, Polyamide
For cable protection systems in a
wide range of applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Vibration-proof connection to
PMAFLEX conduits
High conduit pullout strength
Smooth elbow allows easy guidance through
connector
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VBD-P167GT _VBV-P167
16 17 20 11.0 47.5 x 73.0
_VBD-P213GT _VBV-P213
21 23 25 12.0 57.5 x 85.0
_VBD-P299GT _VBV-P299
29 29 32 67.5 x 96.0
_VBD-P366GT _VBV-P366
36 36 40 13.0 79.0 x 123.0
_VBD-P488GT _VBV-P488
48 48 50 92.5 x 135.0
_ = Insert “B” to order black or “S” to order grey.
Appropriate standard elbows of type VW are available for smaller conduit sizes NW 07 to NW 12.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VAD-P090GT _VAV-P090
910 12
11.0
43.0 x 37.0
_VAD-P112GT _VAV-P112
11 12 16 48.0 x 40.0
_VAD-P132GT _VAV-P132
13.5 48.0 x 41.5
_VAD-P137GT _VAV-P137
17 20 55.5 x 51.5
_VAD-P167GT _VAV-P167
16 55.5 x 51.5
_VAD-P213GT _VAV-P213
21 23 25 63.0 x 58.0
_VAD-P299GT _VAV-P299
29 29 32 12.0 69.0 x 66.0
_VAD-P366GT _VAV-P366
36 36 40 13.0 86.0 x 86.0
_VAD-P488GT _VAV-P488
48 48 50 94.0 x 100.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VA 45° Elbow, PG, Polyamide
www.tnb.ca E41
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide
range of applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VWD-P07MGT-11 _VWV-P07M
7
710 11.0 32.0 x 35.0
_VWD-P07MGT-8
8.0 29.0 x 35.0
_VWD-P070GT-11 _VWV-P070
10 12 11.0 34.0 x 39.5
_VWD-P070GT-8
8.0 31.0 x 39.5
_VWD-P072GT-11 _VWV-P072
12 16 11.0 38.5 x 44.5
_VWD-P072GT-8
8.0 35.5 x 44.5
_VWD-P09MGT-11 _VWV-P09M
9
710 11.0 32.0 x 36.5
_VWD-P09MGT-8
8.0 29.0 x 36.5
_VWD-P090GT-11 _VWV-P090
10 12 11.0 34.0 x 39.5
_VWD-P090GT-8
8.0 31.0 x 39.5
_VWD-P092GT-11 _VWV-P092
12 16 11.0 38.5 x 44.5
_VWD-P092GT-8
8.0 35.5 x 44.5
_VWD-P11MGT-11 _VWV-P11M
11
710 11.0 32.0 x 38.0
_VWD-P11MGT-8
8.0 29.0 x 38.0
_VWD-P110GT-11 _VWV-P110
10 12 11.0 34.0 x 41.0
_VWD-P110GT-8
8.0 31.0 x 41.0
_VWD-P112GT-11 _VWV-P112
12 16 11.0 38.5 x 46.0
_VWD-P112GT-8
8.0 35.5 x 46.0
_VWD-P13MGT-11 _VWV-P13M
13.5
710 11.0 32.0 x 39.5
_VWD-P13MGT-8
8.0 29.0 x 39.5
_VWD-P130GT-11 _VWV-P130
10 12 11.0 34.0 x 42.5
_VWD-P130GT-8
8.0 31.0 x 42.5
_VWD-P132GT-11 _VWV-P132
12 16 11.0 38.5 x 47.5
_VWD-P132GT-8
8.0 35.5 x 47.5
_VWD-P137GT-11 _VWV-P137
17 20
11.0 43.5 x 58.5
_VWD-P137GT-8
8.0 40.5 x 58.5
_VWD-P167GT-11 _VWV-P167
16 11.0 43.5 x 58.5
_VWD-P167GT-8
8.0 40.5 x 58.5
_VWD-P213GT _VWV-P213
21 23 25 12.0 54.0 x 67.0
_VWD-P299GT _VWV-P299
29 29 32 61.5 x 74.5
_VWD-P366GT _VWV-P366
36 36 40 13.0 72.0 x 98.0
_VWD-P488GT _VWV-P488
48 48 50 85.5 x 111.0
_= Insert “B” to order black or “S” to order grey.
Curved elbows of type VB are available for the sizes NW 17 to NW 48.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VW 90° Elbow, PG, Polyamide
www.tnb.ca
E42
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 135° C
Content of delivery:
IP68GT:
Complete: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); sealing insert, O-ring (OR)
Fitting*: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); O-ring (OR)
IP68:
Complete: Fitting with oval clips (OVN2), sealing
insert, conduit seal (NVN3), O-ring (OR)
Fitting* Fitting with oval clips (OVN2), conduit
seal (NVN3), O-ring (OR)
Insert: Sealing insert
For several conductors, multiple sealing inserts
are available (MDE)
Use in railway vehicle and heavy machine
construction
High-grade, specially formulated polyamide,
thread made of nickel-plated brass
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Fits fine (T) and coarse
(G) conduit profiles
VNZ Straight, PG, Strain Relief, Metal
Use in railway vehicle and heavy machine
construction
Separate damp and dry areas
High-grade, specially formulated polyamide
6, thread made of nickel-plated brass, sea-
ling inserts made from TPE-V
Integrated strain relief and optimal ingress
protection at the cable (up to IP68/10 bar)
High thread and system connection strength
Vibration-resistant connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
PG
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
NVNV-P090 MVNV-P090
910 12 12.0 42.0
NVNV-P112 MVNV-P112
11 12 16 45.0
NVNV-P137 MVNV-P137
13.5 17 20 13.0 54.0
NVNV-P167 MVNV-P167
16
NVNV-P213 MVNV-P213
21 23 25 14.0 57.0
NVNV-P293 MVNV-P293
29
NVNV-P299 MVNV-P299
29 32 58.5
NVNV-P366 MVNV-P366
36 36 40 17.0 75.5
NVNV-P488 MVNV-P488
48 48 50
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, pages E28E29).
Cat. No. IP68
Complete,
Black
Cat. No. IP68
Fitting *
Cat. No.
Insert
Thread
Metric
Fits to Conduit Size Terminal
Range (mm)
Thread
Length (mm)
Overall
Length (mm)
NW Metric
NVNZ-P090S/P3 NVNZ-P090R/P DE-P090/P3
9
10 12
6.5–9.5
6.0
49.5
NVNZ-P110S/P1 NVNZ-P110R/P DE-P110/P1
11
4.0–6.5 52.0
NVNZ-P110S/P3 DE-P110/P3
6.5–9.5 52.0
NVNZ-P112S/P1 NVNZ-P112R/P DE-P112/P1
12 16
4.0–6.5
53.5
NVNZ-P112S/P3 DE-P112/P3
6.5–9.5
NVNZ-P112S/P4 DE-P112/P4
7.0–10.5
NVNZ-P160S/P1 NVNZ-P160R/P1 DE-P110/P1
16
10 4.5–6.5
6.5
52.5
NVNZ-P167S/P3 NVNZ-P167R/P DE-P167/P3
17 20
6.5–9.5
61.0
NVNZ-P167S/P4 DE-P167/P4
7.0–10.5
NVNZ-P167S/P5 DE-P167/P5
9.0–13.0
NVNZ-P167S/P6 DE-P167/P6
11.5–15.5
NVNZ-P213S/P4 NVNZ-P213R/P DE-P213/P4
21 23 25 14.0–18.0 7.0 72.0
NVNZ-P213S/P5 NVNZ-P213R1/P DE-P213/P5
17.0–20.5
NVNZ-P299S/P3 NVNZ-P299R/P DE-P299/P3
29 29 32
17.0–20.5
8.0 73.5
NVNZ-P299S/P4 DE-P299/P4
20.0–25.0
NVNZ-P299S/P5 DE-P299/P5
24.0–28.0
NVNZ-P366S/P1 NVNZ-P366R/P DE-P366/P1
36 36 40
27.0–32.0
9.0 88.0
NVNZ-P366S/P2 DE-P366/P2
29.0–34.0
NVNZ-P366S/P3 DE-P366/P3
32.0–36.0
NVNZ-P488S/P1 NVNZ-P488R/P DE-P488/P1
48 48 50 35.0–40.0 10.0 90.5
NVNZ-P488S/P2 NVNZ-P488R/P DE-P488/P2
39.0–44.0
* = without insert
Note: MDE multiple sealing inserts are available for this product.
IP68GT available. Please replace “S” or “R” with “GT” (for example NVNZ-P112GT/P1)
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VN Straight, PG, Metal
www.tnb.ca E43
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide
range of applications
High-grade, specially formulated polyamide,
thread made of nickel-plated brass
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
VB 90° Curved Elbow, PG, Metal
For cable protection systems in a wide
range of applications
High-grade, specially formulated polyamide,
thread made of nickel-plated brass
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Extremely high thread and system
connection strength
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVAV-P090 MVAV-P090
910 12 12.0 50.5 x 37.0
NVAV-P112 MVAV-P112
11 12 16 55.0 x 40.5
NVAV-P137 MVAV-P137
13.5 17 20 13.0 63.5 x 50.0
NVAV-P167 MVAV-P167
16 17 20 63.5 x 50.0
NVAV-P213 MVAV-P213
21 23 25 14.0 73.0 x 60.5
NVAV-P299 MVAV-P299
29 29 32 78.0 x 68.0
NVAV-P366 MVAV-P366
36 36 40 17.0 98.0 x 87.5
NVAV-P488 MVAV-P488
48 48 50 105.0 x 101.0
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP68, Black
Cat. No.
IP68, Grey
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVBV-P167 MVBV-P167
16 17 20 13.0 54.0 x 73.0
NVBV-P213 MVBV-P213
21 23 25 14.0 65.5 x 85.0
NVBV-P299 MVBV-P299
29 29 32 75.0 x 96.0
NVBV-P366 MVBV-P366
36 36 40 17.0 90.5 x 123.0
NVBV-P488 MVBV-P488
48 48 50 103.5 x 135.0
Appropriate standard elbows of type VW are available for smaller conduit sizes NW 07 to NW 12.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VA 45° Elbow, PG, Metal
www.tnb.ca
E44
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Use in railway vehicle and heavy machine
construction
High-grade, specially formulated polyamide,
thread made of nickel-plated brass
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Polyamide free from halogens and cadmium
Extremely high thread and system
connection strength
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66, Black
Cat. No.
IP68, Grey
Thread
PG
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NVWV-P090 MVWV-P090
910 12 12.0 39.5 x 39.5
NVWV-P112 MVWV-P112
11 12 16 45.5 x 45.0
NVWV-P137 MVWV-P137
13.5 17 20 13.0 50.0 x 58.5
NVWV-P167 MVWV-P167
16 17 20 50.0 x 58.5
NVWV-P213 MVWV-P213
21 23 25 14.0 62.0 x 67.0
NVWV-P299 MVWV-P299
29 29 32 69.0 x 74.5
NVWV-P366 MVWV-P366
36 36 40 17.0 83.5 x 98.0
NVWV-P488 MVWV-P488
48 48 50 96.5 x 111.0
Curved elbows of type VB are available for the sizes NW 17 to NW 48.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VW 90° Elbow, PG, Metal
www.tnb.ca E45
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
VA 45° Elbow, Gas, Polyamide
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
Gas (in.)
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VND-G00MGT _VNV-G00M
1/4 710
11.0
34.5
_VND-G000GT _VNV-G000
10 12 36.5
_VND-G010GT _VNV-G010
3/8 10 12 36.5
_VND-G012GT _VNV-G012
12 16 39.0
_VND-G022GT _VNV-G022
1/2 12 16 13.0 41.0
_VND-G027GT _VNV-G027
17 20 49.5
_VND-G043GT _VNV-G043
3/4 23 25 14.0 54.0
_VND-G069GT _VNV-G069
129 32 15.0 56.0
_VND-G076GT _VNV-G076
1-1/4 36 40
18.0
71.0
_VND-G088GT _VNV-G088
1-1/2 48 50 71.5
_VND-G098GT _VNV-G098
248 50 71.5
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
Gas (in.)
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VAD-G000GT _VAV-G000
1/4 10 12 11.0 43.5 x 37.0
_VAD-G012GT _VAV-G012
12 16 48.0 x 40.0
_VAD-G027GT _VAV-G027
3/8 17 20 13.0 57.5 x 51.5
_VAD-G043GT _VAV-G043
23 25 14.0 67.0 x 60.0
_VAD-G069GT _VAV-G069
1/2 29 32 15.0 73.5 x 67.0
_VAD-G076GT _VAV-G076
36 40
18.0
91.5 x 85.5
_VAD-G088GT
3/4 48 50 99.0 x 96.0
_VAD-G098GT _VAV-G098
148 50 99.0 x 101.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VN Straight, Gas, Polyamide
www.tnb.ca
E46
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
Gas (in.)
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VWD-G00MGT _VWV-G00M
1/4 710
11.0
32.0 x 36.5
_VWD-G000GT _VWV-G000
10 12 34.0 x 39.5
_VWD-G010GT _VWV-G010
3/8 34.0 x 40.5
_VWD-G012GT _VWV-G012
12 16 38.5 x 46.0
_VWD-G022GT _VWV-G022
1/2 13.0 40.5 x 47.5
_VWD-G027GT _VWV-G027
17 20 45.5 x 58.5
_VWD-G043GT _VWV-G043
3/4 23 25 14.0 56.0 x 66.5
_VWD-G069GT _VWV-G069
129 32 15.0 64.5 x 73.5
_VWD-G076GT _VWV-G076
1-1/4 36 40
18.0
77.0 x 96.0
_VWD-G088GT _VWV-G088
1-1/2 48 50 90.5 x 106.0
_VWD-G098GT _VWV-G098
290.5 x 111.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VW 90° Elbow, Gas, Polyamide
www.tnb.ca E47
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
VA 45° Elbow, NPT, Polyamide
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit push-in
installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
NPT (in.)
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
_VND-N022GT _VNV-N022
1/2 12 16 13.0 41.5
_VND-N027GT _VNV-N027
17 20 49.5
_VND-N043GT _VNV-N043
3/4 23 25 14.0 54.0
_VND-N069GT _VNV-N069
129 32 15.0 56.0
_VND-N076GT _VNV-N076
1-1/4 36 40
18.0
71.0
_VND-N088GT _VNV-N088
1-1/2 48 50 71.5
_VND-N098GT _VNV-N098
248 50 71.5
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Thread
NPT (in.)
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VAD-N022GT _VAV-N022
1/2 12 16 13.0 50.0 x 41.5
_VAD-N027GT _VAV-N027
17 20 57.5 x 51.5
_VAD-N043GT _VAV-N043
3/4 23 25 14.0 67.0 x 60.0
_VAD-N069GT _VAV-N069
129 32 15.0 73.5 x 67.0
_VAD-N076GT _VAV-N076
1-1/4 36 40
18.0
91.5 x 85.5
_VAD-N088GT _VAV-N088
1-1/2 48 50 99.0 x 96.0
_VAD-N098GT _VAV-N098
250 99.0 x 101.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VN Straight, NPT, Polyamide
www.tnb.ca
E48
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (SVN4)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, SVN4)
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2), flange seal (FG04)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); flange seal (FGO4)
IP68: Fitting with oval clips (OVN2), conduit
and flange seal (NVN3, FG04)
For cable protection systems in a wide
range of applications
High-grade, specially formulated polyamide
6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
Easy mounting: simple conduit
push-in installation
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse
(G) conduit profiles
VO Flange 90°, Polyamide
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Standard flange seal FGO4 made from
EPDM; flange seal FGO4/01 made from NBR
on demand
Very high impact resistance
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Thread
NPT (in.)
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
_VWD-N022GT _VWV-N022
1/2 12 16 13.0 40.5 x 47.5
_VWD-N027GT _VWV-N027
17 20 45.5 x 58.5
_VWD-N043GT _VWV-N043
3/4 23 25 14.0 56.0 x 66.5
_VWD-N069GT _VWV-N069
129 32 15.0 64.5 x 73.5
_VWD-N076GT _VWV-N076
1-1/4 36 40
18.0
77.0 x 96.0
_VWD-N088GT _VWV-N088
1-1/2 48 50 90.5 x 106.0
_VWD-N098GT _VWV-N098
248 50 90.5 x 111.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66
Cat. No.
IP68
Fits to Conduit Size Dimensions (mm)
Width x Length x Depth
Screw
Sizes
NW Metric
_VOD-P167GT _VOV-P167
17 20 46.0 x 66.0 x 35.5 2 x M5
_VOD-P213GT _VOV-P213
23 25 65.5 x 70.0 x 43.0 2 x M6
_VOD-P299GT _VOV-P299
29 32 67.0 x 78.0 x 49.5 4 x M6
_VOD-P366GT _VOV-P366
36 40 85.0 x 102.0 x 65.5 4 x M6
_VOD-P488GT _VOV-P488
48 50 86.0 x 119.0 x 77.5 4 x M6
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VW 90° Elbow, NPT, Polyamide
www.tnb.ca E49
Nylon Flexible Conduit Systems
PMA ®
VIR: IP68 static/IP67 dynamic, conduit side
VID: IP66 static/IP54 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT)
IP68: Fitting with oval clips (OVN2),
conduit seal (NVN3)
VIR: IP68 static/IP67 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT)
IP68: Fitting with oval clips (OVN2), conduit
seal (NVN3)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
VI Female Thread Adapter, Metric, Metal
Use in machine and railway construction
and industry
High-grade, specially formulated polyamide 6,
thread made of nickel-plated brass
Very high impact resistance
High thread and system connection strengths
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66, Black
Cat. No.
IP68, Black
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BVID-M12MGT
M12x1.5 710
8.0
32.0
BVID-M160GT BVIR-M160
M16x1.5 10 12 33.5
BVID-M162GT BVIR-M162
M16x1.5 12 16 36.5
BVIR-M202
M20x1.5 12 16 36.5
BVID-M207GT BVIR-M207
M20x1.5 17 20 44.5
BVID-M253GT BVIR-M253
M25x1.5 23 25 48.5
BVIR-M257
M25x1.5 17 20 44.5
BVID-M329GT BVIR-M329
M32x1.5 29 32
10.0
51.5
BVID-M406GT BVIR-M406
M40x1.5 36 40 65.5
BVID-M508GT BVIR-M508
M50x1.5 48 50 65.5
BVID-M638GT BVIR-M638
M63x1.5 48 50 65.5
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP68, Black
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
NVIR-M120
M12x1.5 10 12 7.0 35.5
NVIR-M162
M16x1.5 12 16 9.0 40.5
NVIR-M207
M20x1.5 17 20 10.5 50.5
NVIR-M253
M25x1.5 23 25 10.5 53.0
NVIR-M329
M32x1.5 29 32 11.0 55.0
NVIR-M406
M40x1.5 36 40 13.5 71.0
NVIR-M508
M50x1.5 48 50 15.0 73.0
NVIR-M638
M63x1.5 48 50 17.5 78.0
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VI Female Thread Adapter, Metric, Polyamide
www.tnb.ca
E50
Nylon Flexible Conduit Systems
PMA ®
VIR: IP68 static/IP67 dynamic, conduit side
FIL: IP67 static/IP65 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP67: Fitting with oval clips (OVN2),
conduitseal (NFN3)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT)
IP68: Fitting with oval clips (OVN2),
conduit seal (NVN3)
For machine, vehicle and traction building
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
VI Female Thread Adapter PG, Metal
For machine, vehicle and traction building
High-grade, specially formulated polyamide
6, thread made of nickel-plated brass
Very high impact resistance
High thread and system connection strengths
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP67, Black
Cat. No.
IP68, Black
Thread
PG
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BFIL-P07M
7
710
8.0
29.0
BFIL-P070
10 12
34.5
BVIR-P070
33.5
BFIL-P090
932.5
BVIR-P090
33.5
BFIL-P112
11 12 16 32.5
BVIR-P112
36.5
BFIL-P117
17 20 35.0
BFIL-P132
13.5 12 16 32.5
BFIL-P137
17 20 33.5
BFIL-P160
16
10 12 7.0 37.0
BFIL-P167
17 20
8.0 33.5
BVIR-P167
8.0 44.5
BFIL-P217
21 10.5 35.5
BFIL-P213
23 25 8.0 39.0
BFIL-P293
29 9.0 42.0
BFIL-P299
29 32 9.0 43.0
BFIL-P363
36
23 25 12.0 51.0
BFIL-P369
29 32 16.0 52.0
BFIL-P366
36 25 13.0 64.0
BFIL-P488
48 48 50 13.0 65.0
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP68, Black
Thread
PG
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
NVIZR-P07M
7 7 10 6.0 33.0
NVIZR-P090
910 12 9.0 37.5
NVIZR-P110
11 10 12 9.0 39.5
NVIZR-P112
11 12 16 9.0 41.5
NVIZR-P167
16 17 20 9.5 49.5
NVIZR-P213
21 23 25 10.0 56.5
NVIZR-P299
29 29 32 12.5 56.5
NVIZR-P366
36 36 40 13.0 73.0
NVIZR-P488
48 48 50 14.0 75.0
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
FI/VI Female Thread Adapter, PG, Polyamide
www.tnb.ca E51
Nylon Flexible Conduit Systems
PMA ®
VIRA: IP68 static/IP67 dynamic, conduit side
VIDA: IP66 static/IP54 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT)
IP68: Fitting with oval clips (OVN2),
conduit seal (NVN3)
VIRB: IP68 static/IP67 dynamic, conduit side
VIDB: IP66 static/IP54 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT)
IP68: Fitting with oval clips (OVN2),
conduit seal (NVN3)
For cable protection systems in a wide
range of applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Suitable for the AMP connector Series CPC
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
VI Female Thread Adapter, UNEF for Souriau UTG-6/ITT Cannon
Trident, Polyamide
For cable protection systems in a wide range of
applications
High-grade, specially formulated
polyamide 6
Very high impact resistance
Suitable for the Souriau connector Series
UTG-6 - ITT Cannon Trident
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66, Black
Cat. No.
IP68, Black
Thread
UNEF
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BVIDA-U15MGT BVIRA-U15M
5/8 in.-24 710
8.0
31.5
BVIDA-U150GT BVIRA-U150
5/8 in.-24 10 12 33.5
BVIDA-U152GT BVIRA-U152
5/8 in.-24 12 16 36.5
BVIDA-U180GT BVIRA-U180
1/4 in.-20 10 12 33.5
BVIDA-U182GT BVIRA-U182
1/4 in.-20 12 16 36.5
BVIDA-U187GT BVIRA-U187
1/4 in.-20 17 20 44.5
BVIDA-U232GT BVIRA-U232
15/16 in.-20 12 16 38.5
BVIDA-U237GT BVIRA-U237
15/16 in.-20 17 20 46.5
BVIDA-U233GT BVIRA-U233
15/16 in.-20 23 25 48.5
BVIDA-U347GT BVIRA-U347
13/8 in.-18 17 20 46.5
BVIDA-U343GT BVIRA-U343
13/8 in.-18 23 25 48.5
BVIDA-U402GT BVIRA-U402
15/8 in.-18 12 16
7.0
55.5
BVIDA-U407GT BVIRA-U407
15/8 in.-18 17 20 61.5
BVIDA-U403GT BVIRA-U403
15/8 in.-18 23 25 60.5
IP68GT available. Please add “GT” after the catalogue no. (Functional description PMAFIX IP68GT, pages E28E29).
Cat. No.
IP66, Black
Cat. No.
IP68, Black
Thread
UNEF
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BVIDB-U162GT BVIRB-U162
11/16 in.-24 12 16 4.0 43.5
BVIDB-U202GT BVIRB-U202
13/16 in.-20 12 16 4.5 44.0
BVIDB-U232GT BVIRB-U232
15/16 in.-20 12 16 4.5 49.0
BVIDB-U237GT BVIRB-U237
15/16 in.-20 17 20 4.5 52.0
BVIDB-U267GT BVIRB-U267
11/16 in.-18 17 20 4.5 52.0
BVIDB-U297GT BVIRB-U297
13/16 in.-18 17 20 6.5 55.5
BVIDB-U293GT BVIRB-U293
13/16 in.-18 23 25 6.5 52.0
BVIDB-U323GT BVIRB-U323
15/16 in.-18 23 25 6.5 52.0
BVIDB-U357GT BVIRB-U357
17/16 in.-18 17 20 6.5 58.5
BVIDB-U353GT BVIRB-U353
17/16 in.-18 23 25 6.5 54.0
BVIDB-U359GT BVIRB-U359
17/16 in.-18 29 32 6.5 50.5
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
Fittings for Nylon Flexible Conduits
VI Female Thread Adapter, UNEF for
AMP CPC Series, Polyamide
www.tnb.ca
E52
Nylon Flexible Conduit Systems
PMA ®
VIVG: IP68 static/IP67 dynamic, conduit- and
thread side
VIDG: IP66 static/IP54 dynamic, conduit- and
thread side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Fitting with pre-assembled universal
safety clips (AFN2), thread seal (OR)
IP68GT: Fitting with pre-assembled universal
safety clips (AFN2) and conduit seal
(NVN3-GT); thread seal (O-Ring)
IP68: Fitting with oval clips (OVN2), conduit
and thread seal (NVN3, OR)
Use in machine, vehicle and traction
building industries
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Fits fine (T) and coarse (G)
conduit profiles
FI Female Thread Adapter, Fine-Metric, Transparent
Use in machine and vehicle building,
in connection with electronic sensors
High-grade, specially formulated polyamide 6
Very high impact resistance
Light-emitting diodes are recognizable
through the connector
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties, free
from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66, Black
Cat. No.
IP68, Black
Thread
UNEF
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BVIVG-U152
5/ in.–24 12 16 8.0 36.5
BVIVG-U187
3/4 in.–20 17 20
9.0
46.5
BVIVG-U210
7/8 in.–20 10 07 37.0
BVIDG-U212GT BVIVG-U212
7/8 in.–20 12 16 38.5
BVIDG-U217GT BVIVG-U217
7/8 in.–20 17 20 46.5
BVIDG-U242GT BVIVG-U242
1 in.–20 12 16 40.5
BVIVG-U243
1 in.–20 23 25 55.0
BVIDG-U247GT BVIVG-U247
1 in.–20 17 20 47.5
BVIVG-U292
1-3/16 in.–18 12 16 40.5
BVIDG-U293GT BVIVG-U293
1-3/16 in.–18 23 25 55.0
BVIDG-U297GT BVIVG-U297
1-3/16 in.–18 17 20 47.5
BVIVG-U299
1-3/16 in.–18 29 29 47.0
BVIVG-U352
1-7/16 in.–18 12 16 39.0
BVIDG-U353GT BVIVG-U353
1-7/16 in.–18 23 25 52.0
BVIVG-U356
1-7/16 in.–18 36 40 63.0
BVIDG-U357GT BVIVG-U357
1-7/16 in.–18 17 20 46.5
BVIDG-U359GT BVIVG-U359
1-7/16 in.–18 29 29 52.0
BVIDG-U433GT BVIVG-U433
1-3/4–18 UNS 23 25
10.0
52.0
BVIDG-U436GT BVIVG-U436
1-3/4–18 UNS 36 40 62.5
BVIVG-U437
1-3/4–18 UNS 17 20 46.5
BVIDG-U439GT BVIVG-U439
1-3/4–18 UNS 29 32 51.5
BVIVG-U503
2 in.–18 UNS 23 25 51.5
BVIVG-U503/01
2 in.–18 UNS 23 25 62.5
BVIDG-U506GT BVIVG-U506
2 in.–18 UNS 36 40 62.5
BVIVG-U508
2 in.–18 UNS 48 50 64.5
BVIDG-U509GT BVIVG-U509
2 in.–18 UNS 29 32 55.0
BVIVG-U563
2-1/4 in.–16 UN 23 25 51.0
BVIDG-U566GT BVIVG-U566
2-1/4 in.–16 UN 36 40 62.0
BVIVG-U568
2-1/4 in.–16 UN 48 50 64.0
BVIDG-U569GT BVIVG-U569
2-1/4 in.–16 UN 29 32 51.0
BVIVG-U628
2-1/4 in.–16 UN 48 50O 64.0
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28-E29).
Cat. No.
IP67, Transparent
Thread
Fine-Metric
Fits to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
TFIL-F08M
8
710
6.5 29.5
TFIL-F12M
12
6.0
56.0
TFIL-F18M
18 56.5
TFIL-F30M
30
TFIL-F120
12
10 12 57.0
TFIL-F180
18
TFIL-F300
30
Fittings for Nylon Flexible Conduits
VI Female Thread Adapter, UNEF for MIL C 5015
FIL: IP67 static / IP65 dynamic, conduit side
Temperature range: -40°C to 105°C;
Short term to 120°C
Content of delivery:
Fitting with oval clip (OVN2), conduit seal (NFN3)
www.tnb.ca E53
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Distributor fitting with pre-assembled
universal safety clips (AFN2)
IP68GT: Distributor fitting with pre-assembled
universal safety clips (AFN2) and con-
duit seal (NVN3-GT)
IP68: Distributor fitting with oval clips (OVN2),
conduit seal (NVN3)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Distributor fitting with pre-assembled
universal safety clips (AFN2)
IP67: Distributor fitting with oval clips (OVN2),
conduit seals (NFN3)
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to PMAFLEX®
conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
FV V Pieces
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Input Fits to Conduit Size Outputs Fits to Conduit Size
NW Metric NW Metric
_VYD-100707GT _VYR-100707
10 12 710
_VYD-121010GT _VYR-121010
12 16 10 12
_VYD-171212GT _VYR-171212
17 20 12 16
_VYD-231717GT _VYR-231717
23 25 17 20
_VYD-292323GT _VYR-292323
29 32 23 25
_VYD-362929GT _VYR-362929
36 40 29 32
_VYD-483636GT _VYR-483636
48 50 36 40
_ = Insert “B” to order black or “S” to order grey.
The input/output sizes can be adapted with the AVD/AVR conduit adapters.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28-E29).
Cat. No.
IP66
Cat. No.
IP67
Input Fits to Conduit Size Outputs Fits to Conduit Size
NW Metric NW Metric
_FVD-100707GT _FVL-100707
10 12 710
_FVD-101010GT _FVL-101010
10 12 10 12
_FVD-121010GT _FVL-121010
12 16 10 12
_FVD-171010GT _FVL-171010
17 20 10 12
_FVD-171212GT _FVL-171212
17 20 12 16
_FVD-231717GT _FVL-231717
23 25 17 20
_ = Insert “B” to order black or “S” to order grey.
Fittings for Nylon Flexible Conduits
VY Y Pieces
www.tnb.ca
E54
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Distributor fitting with pre-assembled
universal safety clips (AFN2)
IP67: Distributor fitting with oval clips (OVN2),
conduit seals (NFN3)
IP68GT: Distributor fitting with pre-assembled
universal safety clips (AFN2) and
conduit seal (NVN3-GT)
IP68: Distributor fitting with oval clips (OVN2),
conduit seals (NVN3)
Fittings for Nylon Flexible Conduits
FT/VT T Pieces
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP67
Input Fits to Conduit Size Outputs Fits to Conduit Size
NW Metric NW Metric
_FTD-101010GT
10 12 10 12
_FTD-121212GT
12 16 12 16
_FTD-171717GT
17 20 17 20
_FTD-292323GT _FTL-292323 (!)
29 32 23 25
_FTD-292929GT
29 32 29 32
_VTR-101010
10 12 10 12
_VTR-121212
12 16 12 16
_VTR-171717
17 20 17 20
_VDD-232323GT _VTR-232323
23 25 23 25
_VTR-292929
29 32 29 32
_VTD-363636GT _VTR-363636
36 40 36 40
_VTD-484848GT _VTR-484848
48 50 48 50
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” after the catalogue no.
(Functional description PMAFIX IP68GT, pages E28E29).
(!) Please note: The article “FTL” (IP67) will be discontinued! For new applications we recommend _VTR (IP68).
www.tnb.ca E55
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
System support and 2-piece screws for securing
of the lid (optional); without mounting accessories
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
System support with assembling screws; without
mounting accessories
Accessories for Nylon Flexible Conduits
GPS One-Piece System Supports
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
One-piece construction, stackable
Excellent impact resistance
Heavy design, high retention forces
Applicable with standard metal C rails
Easy pre-installation by conduit snap-in
Clasp for easy pre-mounting and
final assembly
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
The following nominal widths can be
combined for stacking:
NW 17 with NW 23, NW 29 with NW 36,
NW 48 with NW 56
GP System Supports for Stacking
For cable protection systems in a wide
range of applications
High-grade, specially formulated polyamide
Variable stacking possibilities — due to the
block system, a high rigidity is guaranteed
Strain relief due to gripping around conduit
Especially suitable for dynamic applications
due to rounded edges
Variety of support possibilities
Self extinguishing, free from halogens
and cadmium
Excellent impact strength
Cat. No.
Fine Profile
Fits to Conduit Size Dimensions
NW Metric Din-NW Width (mm) Height (mm) Depth (mm)
BGPS-17
17 20 270.0 51.0
30.0
BGPS-23
23 25
BGPS-29
29 32 385.0 65.0
BGPS-36
36 40
BGPS-48
48 50 4115.0 92.5
BGPS-56
56
Cat. No.
Fine Profile
Cat. No.
Coarse Profile
Fits to Conduit Size Dimensions
NW Metric Width (mm) Height (mm) Depth (mm)
_GP-16T _GP-16G
17 20 47.5
66.0 36.0
_GP-21T _GP-21G
23 25
_GP-29T _GP-29G
29 32 61.5
_GP-36T _GP-36G
36 40
_GP-48T _GP-48G
48 50 76.0
_GP-56G
56 87.0 78.0
_ = Insert “B” to order black or “S” to order grey.
www.tnb.ca
E56
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -50° C to 105° C
Temperature range: -40° C to 105° C;
Short term to 160° C
Accessories for Nylon Flexible Conduits
SGB Tube Clamps
Especially suitable for the
mounting of static conduits
Galvanized steel according to DIN 3016
Elastomer free from halogens (EPDM)
For the mounting of static conduits
Smooth connection to PMAFLEX®
corrugated conduits
Good ozone and aging resistance
GN Half Shells
Used for fixing PMA® conduits in conjunc-
tion with beam systems, particularly in
traction and machine applications
High-grade, specially formulated polyamide
Variable combinations
Strain relief due to gripping around conduit
Especially suitable for dynamic applications
due to rounded edges
Variety of support possibilities
Self extinguishing
Free from halogens and cadmium
Excellent impact strength
Cat. No.
Fine Profile, Black
Cat. No.
Coarse Profile, Black
Fits to Conduit Size Outside
Diameter (mm)
Dimensions
Width (mm)
NW Metric
BGN-S12T
12 16 26.5
34.0
BGN-S17T BGN-S17G
17 20 32.0
BGN-S23T BGN-S23G
23 25 39.5
BGN-S29T BGN-S29G
29 32 47.0
BGN-S36T
36 40 55.0 36.5
BGN-S36G
36 40 55.0 34.0
BGN-S48T
48 50 66.5 36.5
BGN-S48G
48 50 66.5 34.0
BGN-S70G
70 80 93.5. 38.0
Cat. No.
Fine Profile, Black
Fits to Conduit Size Width (mm) Fixing
Screw
NW Metric
SGB-07
7 10
13.0 (1) M4
SGB-09
10 12
SGB-11
12 16
SGB-16
17 20 16.0 (1) M5
SGB-21
23 25
SGB-29
29 32
19.0 (1) M6
SGB-36
36 40
SGB-48
48 50
www.tnb.ca E57
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C
Temperature range: -40° C to 105° C;
Used in general machine
and installation applications
High-grade, specially formulated polyamide
Self extinguishing
Free from halogens and cadmium
GH Tube Clamps
Used in general machine and installation
applications
High-grade, specially formulated polyamide
Self extinguishing
Free from halogens and cadmium
Nominal widths: 2395
Cat. No.
Black
Cat. No.
Grey
Fits to Conduit Size Dimensions
Width (mm)
Fixing
Screw
NW Metric
BGH-23 SGH-23
23 25 58.0 (2) M5
BGH-29 SGH-29
29 32 70.0
(2) M6
BGH-36 SGH-36
36 40 80.0
BGH-48 SGH-48
48 50 94.0
Cat. No.
Black
Cat. No.
Grey
Fits to Conduit Size Dimensions
Width
Fixing
Screw
NW Metric
BGL-07 SGL-07
07 10 25.0
(1) M4
BGL-10 SGL-10
10 12 27.0
BGL-12 SGL-12
12 16 31.0
BGL-17 SGL-17
17 20 39.5 (1) M5
BGL-23 SGL-23
23 25 49.0
BGL-29 SGL-29
29 32 57.0 (1) M6
Accessories for Nylon Flexible Conduits
GL Tube Clamps
www.tnb.ca
E58
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Flange part, fixation clamps (including two
screws), conduit seal (NVN3), flange seal
(FGO4 or FGO4/01)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Flange part, fixation clamps (including two
screws), conduit seal (NVN3), flange seal
(FGO4 or FGO4/01)
Large-Size Nylon Flexible
Conduits and Connectors
GGV Flange, Straight
Use in railway vehicle construction as well as
in a wide range of industrial applications with
high sealing and safety requirements
High-grade, specially formulated polyamide 6
Flange seal FGO4 made from EPDM
Flange seal FGO4/01 made from NBR on
special request
Very high impact strength
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP68, IP69K
Very good chemical properties
Free from halogens and cadmium
If the application temperature is above 70° C,
we recommend using an additional internal
conduit support sleeve (BES)
GOV Flange, 90° Elbow
Use in railway vehicle construction as well as
in a wide range of industrial applications with
high sealing and safety requirements
High-grade, specially formulated polyamide 6
Flange seal FGO4 made from EPDM
Flange seal FGO4/01 made from NBR on
special request
Very high impact strength
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP68, IP69K
Very good chemical properties
Free from halogens and cadmium
If the application temperature is above
70° C, we recommend using an additional
internal conduit support sleeve (BES)
Cat. No.
Black
Fits to
NW
Dimensions
Width (mm) Height (mm) Depth (mm)
BGGV-56
56 82.0 97.0 42.0
BGGV-70
70 97.0 114.0 48.0
BGGV-95
95 126.0 146.0 53.0
Cat. No.
Black
Fits to
NW
Dimensions
Width (mm) Height (mm) Depth (mm)
BGOV-56
56 82.0 97.0 101.0
BGOV-70
70 97.0 114.0 115.0
BGOV-95
95 126.0 146.0 151.0
www.tnb.ca E59
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Flange part, fixation clamps (including two
screws), flange seal (FGO4 or FGO4/01), conduit
seal ring (SGO3, optional for IP65)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Flange part, fixation clamps (including two
screws), flange seal (FGO4 or FGO4/01), conduit
seal ring (SGO3, optional for IP65)
Large-Size Nylon Flexible
Conduits and Fittings
GG Flange, Straight
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Flange seal FGO4 made from EPDM
Flange seal FGO4/01 made from NBR
Very high impact strength
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP50 (IP65 with conduit
seal ring)
Very good chemical properties
Free from halogens and cadmium
GO Flange, 90° Elbow
For cable protection systems in a wide range
of applications
High-grade, specially formulated polyamide 6
Flange seal FGO4 made from EPDM
Flange seal FGO4/01 made from NBR
Very high impact strength
Vibration-proof connection to
PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP50 (IP65 with
conduit seal ring)
Very good chemical properties
Free from halogens and cadmium
Cat. No.
Black
Cat. No.
Grey
Fits to
NW
Dimensions
Width (mm) Height (mm) Depth (mm)
BGG-56 SGG-56
56 82.0 97.0 42.0
BGG-70 SGG-70
70 97.0 114.0 48.0
BGG-95 SGG-95
95 126.0 146.0 53.0
BGG-125 SGG-125
125 194.0 79.0
Cat. No.
Black
Cat. No.
Grey
Fits to
NW
Dimensions
Width (mm) Height (mm) Depth (mm)
BGO-56 SGO-56
56 82.0 97.0 101.0
BGO-70 SGO-70
70 97.0 114.0 115.0
BGO-95 SGO-95
95 126.0 146.0 149 .0
www.tnb.ca
E60
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Threaded connector body, fixation clamps (includ-
ing two screws), conduit seal ring (SGO3, optional
for IP65)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Threaded connector body, fixation clamps
(including two screws), conduit seal ring
(SGO3, optional for IP65)
Large-Size Nylon Flexible
Conduits and Fittings
GG Straight, Male Thread
For cable protection systems
in a wide range of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Easy mounting with locking clamps
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP50 (IP65 when using
enclosed conduit and thread seal ring)
Very good chemical properties
Free from halogens and cadmium
GI Straight, Female Thread
For cable protection systems
in a wide range of applications
High-grade, specially formulated polyamide 6
Very high impact resistance
Easy mounting with locking clamps
Vibration-proof connection
to PMAFLEX® conduits
High conduit pullout strength
Ingress protection: IP50 (IP65 on conduit
side with enclosed conduit seal ring)
Very good chemical properties
Free from halogens and cadmium
Cat. No.
Black
Cat. No.
Grey Thread Fits to
NW
Thread
Length (mm)
Dimensions
Height (mm)
Dimensions
Depth (mm)
BGG-M6356 SGG-M6356
M63x1.5 56 18.0 98.0 57.5
BGG-P3656 SGG-P3656
PG 36 57.3
Cat. No.
Black
Cat. No.
Grey Thread Fits to
NW
Thread
Length (mm)
Dimensions
Height (mm)
Dimensions
Depth (mm)
BGI-M7556 SGI-M7556
M75x1.5 56 15.0 98.0 53.3
www.tnb.ca E61
Nylon Flexible Conduit Systems
PMA ®
Large-Size Nylon Flexible
Conduits and Fittings
Jumbo Conduits
Cat. No.
Black
Cat. No.
Grey
Conduit Size
NW
Conduit Size
Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat./DYN
Radius (mm)
PU
Meter
PCLG-56B PCLG-56S
56 68 56.3 67.2 130/_ 30
PCLG-70B PCLG-70S
70 80 67.5 80.0 160/_ 30/10
PCLG-95B PCLG-95S
95 106 91.5 106.0 210/_ 30/10
PCLG-125B PCLG-125S
125 146 126.5 146.5 450/_ 6
PIHG-56B PIHG-56S
56 68 56.3 67.2 110/270 30
PIHG-70B PIHG-70S
70 80 67.2 79.6 150/350 30/10
PIHG-95B PIHG-95S
95 106 91.3 106.0 170/450 30/10
PIHG-125B PIHG-125S
125 146 126.5 146.5 350/4 80 20
VOHG-56B VOHG-56S
56 68 55.5 67.2 135/_ 30
VOHG-70B VOHG-70S
70 80 67.0 80.0 200/_ 10
VOHG-95B VOHG-95S
95 106 90.5 106.0 300/_ 10
VOHG-125B VOHG-125S
125 146 126.0 146.5 480/_ 6
VCSG-56B VCSG-56S
56 68 56.1 67.2 150/_ 30
VCSG-70B VCSG-70S
70 80 66.5 80.0 200/_ 10
VCSG-95B VCSG-95S
95 106 91.0 106.0 300/_ 10
PCSG-56B PCSG-56S
56 68 56.1 67.2 130/280 30
PCSG-70B PCSG-70S
70 80 66.5 80.0 170/360 10
PCSG-95B PCSG-95S
95 106 91.0 106.0 250/470 10
PUEG-56B
56 68 56.3 67.2 90/170 30
PUEG-70B
70 80 68.2 80.2 100/220 30
CYLG-56B CYLG-56S
56 68 56.3 67.2 120/_ 30
CYLG-70B CYLG-70S
70 80 68.0 80.0 160/_ 30/10
CYLG-90B CYLG-95S
95 106 91.9 106.0 210/_ 10
CYLG-125B CYLG-125S
125 146 126.5 146.5 450/_ 6
For actual cat. number, add PU METER at the end. Example: PCLG-56B.30
www.tnb.ca
E62
Nylon Flexible Conduit Systems
PMA ®
Large-Size Nylon Flexible
Conduits and Fittings
PACOF Flexible Medium, Divisible
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius
for static (fixed)
installation.
Cat. No.
Black
Conduit Size
NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PACOF-07B
07 5.6 10.0 30
50
PACOF-10B
10 8.5 12.8 33
PACOF-12B
12 11.0 15.6 35
PACOF-17B
17 15.5 21.1 45
PACOF-23B
23 22.1 28.4 70
PACOF-29B
29 27.2 34.5 120
PACOF-36B
36 32.0 42.4 145 30
PACOF-48B
48 43.9 54.1 150
PACOF-70B
70 62.0 79.0 190 10
For actual cat. number, add PU METER at the end. Example: PACOF-07B.50
Cat. No.
Black
Conduit Size
NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
PPCOF-07B
07 5.6 10.0 25
50
PPCOF-10B
10 8.5 12.8 28
PPCOF-12B
12 11.0 15.6 35
PPCOF-17B
17 15.1 21.1 45
PPCOF-23B
23 22.1 28.4 60
PPCOF-29B
29 26.6 34.5 100
PPCOF-36B
36 31.8 42.4 120 30
PPCOF-48B
48 43.9 54.1 140
PPCOF-70B
70 60.5 78.0 200 10
For actual cat. number, add PU METER at the end. Example: PPCOF-07B.50
Use in machine building and plant
construction
Specially modified polyamide 6
Easy installation and trouble-free
retrofitting, applicable also for repairs
Can be opened and closed again
in longitudinal direction any time
Self extinguishing
Free from halogens and cadmium
PACOF Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -40° C to 105° C;
Short term to 160° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
PPCOF Very Flexible Medium, Divisible
Use in machine building and plant
construction
Specially modified polypropylene PP
Easy installation and trouble-free
retrofitting, applicable also for repairs
Can be opened and closed again
in longitudinal direction any time
PPCOF Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Temperature range: -20° C to 105° C;
Short term to 150° C
Chemical resistance: Fuels, mineral oils, fats, alkalies,
weak acids, etc.
www.tnb.ca E63
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C
Temperature range: -50° C to 105° C
Temperature range: -40° C to 105° C
Large-Size Nylon Flexible
Accessories
GH Tube Clamps
For mounting conduits in a wide
range of applications
High-grade, specially formulated polyamide 6
One-piece design
Integrated rib provides axial strain relief
Allows turning of the conduit, thus avoiding
torsion stresses
Pre-fixation on the conduit possible
Allows solid fixation with two screws
Self extinguishing
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
No corrosion
SGS Tube Clamps
For mounting of static conduits
Galvanized steel
Elastomer profile (EPDM)
Elastomer profile, free from halogens
Smooth connection to PMAFLEX®
corrugated conduits
Good ozone and aging resistance
SGO3 Conduit Seal Rings
Used at the conduit end for sealing
between the PMAGRIP flanges GG/GI/GO
and PMAFLEX® Jumbo conduits
Nitrile rubber
Cat. No.
Black
Cat. No.
Grey
Fits to Conduit Size Dimensions
Width (mm)
Fixing
Screw
NW Metric
BGH-56 SGH-56
56 63 26.0
(2) M8
BGH-70 SGH-70
70 80 30.0
BGH-95 SGH-95
95 106 30.0
Cat. No.
Black
Fits to
NW
Dimensions
Width (mm) Height (mm) Depth (mm)
SGS-36
36 80.0 48.0 19.0
SGS-48
48 94.0 58.0
SGS-56
56 118.0 72.0
24.0
SGS-70
70 130.0 85.0
SGS-95
95 156.0 110.0
SGS-125
125 200.0 152.0
Cat. No.
Black
Fits to
NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Dimensions
Width (mm)
SGO3-56
56 49.5 61.0
1.5
SGO3-70
70 61.5 74.0
SGO3-95
95 86.0 102.0
SGO3-125
125 122.0 142.0 2.0
www.tnb.ca
E64
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 100° C;
Short term 130° C
Temperature range: -40° C to 100° C;
Short term 130° C
Divisible-System Nylon Flexible
Conduits and Fittings
TN Divisible Connectors, Metric
Connect with divisible PMA® COFLEX
conduits and PMA® COFIX locknuts
For installation upon fully assembled
cable looms or repair in machine
and plant construction
High-grade, specially formulated polyamide 6
High impact resistance
Easy installation
Very good chemical properties
Free from halogens and cadmium
GTN Divisible Locknuts, Metric
Connect with divisible PMA® COFLEX
conduits and PMA® COFIX locknuts
For installation upon fully assembled
cable looms or repair in machine
and plant construction
High-grade, specially formulated polyamide 6
High impact resistance
Easy installation
Very good chemical properties
Free from halogens and cadmium
Cat. No.
Black
Thread
Metric
Fits to Conduit
Coflex NW
Inside
Diameter (mm)
Outside
Diameter (mm)
Outside
Diameter (mm)
BTNO-M1610
M16x1.5 10 11.0 25.5 36.0
BTNO-M2014
M20x1.5 14 14.5 29.0 41.0
BTNO-M2520
M25x1.5 20 19.0 35.0 43.0
BTNO-M3223
M32x1.5 23 26.0 44.0 50.5
BTNO-M4037
M40x1.5 37 32.0 53.0 59.0
BTNO-M5045
M50x1.5 45 42.0 69.0 67.5
Cat. No.
Black
Thread
Metric
Fits to Coflex
Connector
Outside
Diameter (mm)
Outside
Diameter (mm)
BGTN-M1610
M16x1.5 BTNO-M1610 21.5 8.0
BGTN-M2014
M20x1.5 BTNO-M2014 29.0 8.0
BGTN-M2520
M25x1.5 BTNO-M2520 35.5 9.0
BGTN-M3223
M32x1.5 BTNO-M3223 44.0 12.0
BGTN-M4037
M40x1.5 BTNO-M4037 52.5 15.0
BGTN-M5045
M50x1.5 BTNO-M5045 69.0 15.0
www.tnb.ca E65
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Temperature range: -50° C to 105° C
Chemical resistance: Very good weather, ozone-
and aging resistance; resistant to mineral oils
and fats
Divisible-System Nylon Flexible
Accessories
FH System Supports
Use in machine building and
plant construction
High-grade, specially formulated
polyamide 6
Very high impact resistance
Optimal axial strain relief due
to integrated rib
Quick installation due to single-hole fixing
For increased stress due to heavy cables
and wires, closing with cable tie is possible
Very good chemical properties
Free from halogens and cadmium
Fits to rail system supports FHS
GB Tube Clamps
For the mounting of static conduits
Galvanized steel according to DIN 3016
Elastomer profile (EPDM), free
from halogens
Smooth connection to PMAFLEX®
corrugated conduits
Good ozone and aging resistance
Cat. No.
Black Fixing Screw Fits to Conduit Size
Coflex NW
Dimensions (mm)
Width x Length x Depth
BFH-09
M5 10 20 x 19 x 23
BFH-01
M5 14 20 x 24 x 27
BFH-20
M6 20 20 x 35 x 40
BFH-23
M6 23 20 x 43 x 45.5
BFH-37
M6 37 20 x 52 x 52
BFH-48
M6 45 20 x 66 x 66
Cat. No.
Black
Fits to Conduit Size Fits to Conduit Size
Coflex NW
Dimensions
Width (mm)
NW Metric
SGB-09
10 12 10 13.0
SGB-14
14
SGB-20
20 15.0
SGB-23
23
SGB-36
36 40 37 19.0
SGB-48
48 50 45
www.tnb.ca
E66
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Fitting with oval clips (OVN2),
conduit and thread seals (NVN3, SVN4 or OR)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Fitting with oval clips (OVN2), conduit and thread
seals (NVN3, SVN4 or OR)
Temperature range: -40° C to 105° C
Content of delivery:
Adapter, thread seal (SVN4 or OR)
Special Products
SB 90° Curved Elbow, Metric, Metal, Swivel
For applications with high technical
requirements, mainly in machine building
Suitable for occasional rotation
High-grade formulated polyamide 6, thread
and integrated swivel adapter made from nic-
kel-plated brass
Very high impact resistance
High thread and system connection strength
Suitable for occasional rotation
Round guidance within the connector
Easy introduction of wires and cables
Vibration-proof connection
to PMAFLEX® conduits
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
SB 90° Curved Elbow, PG, Metal, Swivel
For applications with high technical
requirements, mainly in machine building
Suitable for occasional rotation
High-grade formulated polyamide 6, thread
and integrated swivel adapter made from
nickel-plated brass
Very high impact resistance
High thread and system connection strength
Suitable for occasional rotation
Round guidance within the connector
Easy introduction of wires and cables
Vibration-proof connection to
PMAFLEX® conduits
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
SWA Swivel Adapters, Metric
Allow PMA® connectors to swivel freely
in applications where such movements
is occasionally necessary
Nickel-plated brass
Connect to PMA® connectors
with metal threads
Include thread edge protection
Include corresponding seals up to IP67/IP68
Cat. No.
IP67
Thread
Metric
Outside
Diameter (mm)
Dimensions
Length (mm)
SWA-M16-10
M16x1.5 23.0 37.5
SWA-M20-10
M20x1.5 27.0 38.5
SWA-M25-11
M25x1.5 32.0 41.0
SWA-M32-13
M32x1.5 45.0 46.5
SWA-M40-13
M40x1.5 55.0 47.5
SWA-M50-14
M50x1.5 59.0 49.5
SWA-M63-14
M63x1.5 75.0 52.0
Cat. No.
IP68, Black
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NSBV-P167-6.5
16 17 20 6.5 58.0 x 75.5
NSBV-P213-7
21 23 25 7.0 69.0 x 87.5
NSBV-P299-8
29 29 32 8.0 80.0 x 98.0
NSBV-P366-9
36 36 40 9.0 91.5 x 127.5
NSBV-P488-10
48 48 50 10.0 106.0 x 139.0
Cat. No.
IP68, Black
Thread
Metric
Fits to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NSBV-M207-10
M20x1.5 17 20 10.0 62.5 x 74.5
NSBV-M253-11
M25x1.5 23 25 11.0 73.0 x 87.5
NSBV-M329-13
M32x1.5 29 32 13.0 86.5 x 98.0
NSBV-M406-13
M40x1.5 36 40 13.0 98.5 x 127.5
NSBV-M409-13
M40x1.5 29 32 13.0 86.5 x 98.0
NSBV-M508-14
M50x1.5 48 50 14.0 113.0 x 139.0
NSBV-M638-14
M63x1.5 48 50 14.0 110.0 x 139.0
www.tnb.ca E67
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C
Content of delivery:
Adapter, thread seal (SVN4 or OR)
Temperature range: -40° C to 105° C
Content of delivery:
Adapter, thread seal (SVN4)
Temperature range: -40° C to 105° C
Content of delivery:
Adapter, thread seal (SVN4)
Special Products
SWA Swivel Adapters, PG
Allow PMA® connectors to swivel freely
in applications where such movements
is occasionally necessary
Nickel-plated brass
Connect to PMA® connectors with
metal threads
With thread edge protection
With corresponding seals up to IP67/IP68
SCA Spin Couplers, Metric
Allow the easy positioning of elbow
connectors with metal threads
Nickel-plated brass
Connect to PMA® connectors with
metal threads
High fastening torque
Include thread edge protection
Up to IP68 (IEC 60529/EN 60529)
SCA Spin Couplers, PG
Allow the easy positioning of elbow
connectors with metal threads
Nickel-plated brass
Connect to PMA® connectors with
metal threads
High fastening torque
Include thread edge protection
Up to IP68 (IEC 60529/EN 60529)
Cat. No.
IP68
Thread
PG
Outside
Diameter (mm)
Dimensions
Length (mm)
SCA-P09
922.0 35.0
SCA-P11
11 26.0 36.0
SCA-P16
16 29.0 38.0
SCA-P21
21 39.0 41.0
SCA-P29
29 44.0 42.5
SCA-P36
36 59.0 49.0
SCA-P48
48 69.0 50.5
Cat. No.
IP68
Thread
Metric
Outside
Diameter (mm)
Dimensions
Length (mm)
SCA-M16-10
M16x1.5 22.0 32.0
SCA-M20-10
M20x1.5 26.0 33.0
SCA-M25-11
M25x1.5 32.0 35.0
SCA-M32-13
M32x1.5 39.0 39.5
SCA-M40-13
M40x1.5 50.0 41.0
SCA-M50-14
M50x1.5 59.0 43.5
SCA-M63-14
M63x1.5 75.0 45.5
Cat. No.
IP67
Thread
Metric
Outside
Diameter (mm)
Dimensions
Length (mm)
SWA-P09
923.0 44.5
SWA-P11
11 27.0 45.5
SWA-P16
16 32.0 48.0
SWA-P21
21 40.0 51.0
SWA-P29
29 50.0 52.0
SWA-P36
36 59.0 55.0
SWA-P48
48 70.0 55.0
www.tnb.ca
E68
Nylon Flexible Conduit Systems
PMA ®
VNR: IP68 static/IP67 dynamic, conduit
side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP68: Fitting with oval clips (OVN2), conduit
seal (NVN3); clamp according to
catalogue number
IP68GT: Fitting with pre-assembled univeral
safety clips (AFN2) and conduit seal
(NVN3-GT); clamp according to
catalogue number)
VNR: IP68 static/IP67 dynamic, conduit side
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
Fitting with oval clips (OVN2), conduit seal
(NVN3); clamp according to catalogue number
Special Products
VN-REM Connection to Solid Tube, Metric
Use in railway vehicle construction and other
applications where metric metal tubes are to be
connected with the flexible PMAFLEX® system
High-grade, specially formulated polyamide 6;
jubilee clip made of galvanized bright steel
Very high impact resistance
Quick connection of solid metal tubes with
flexible PMA® conduits
Available with or without jubilee clip
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
VN-RE Connection to Solid Tube, PG
Use in railway vehicle with PG dimensions,
construction and other applications where
metal tubes are to be connected with the
exible PMAFLEX® system
High-grade, specially formulated polyamide 6;
jubilee clip made of galvanized bright steel
Very high impact resistance
Quick connection of solid metal tubes with
flexible PMA® conduits
Available with or without jubilee clip
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No. IP68
Without Clamp
Cat. No. IP68
With Clamp
Fits to Conduit Size Steel Tube
Metric
Inside
Diameter (mm)
Overall
Length (mm)
NW Metric
_VNR-REM162 _VNR-REM162-24
12 16 M16 16.0 54.0
_VNR-REM207 _VNR-REM207-28
17 20 M20 20.0 65.0
_VNR-REM253 _VNR-REM253-32
23 25 M25 26.0 71.0
_VNR-REM329 _VNR-REM329-44
29 32 M32 32.0 71.0
_VNR-REM406 _VNR-REM406-50
36 40 M40 40.0 90.0
_VNR-REM508 _VNR-REM508-65
48 50 M50 50.0 90.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” to catalogue no. or insert before clamp size (e.g. BVNR-REM162GT, BVNR-REM162GT24).
(Functional description PMAFIX IP68GT, pages E28E29).
Cat. No. IP68
Without Clamp
Cat. No. IP68
With Clamp
Fits to Conduit Size Steel Tube
PG
Inside
Diameter
(mm)
Overall
Length
(mm)
NW Metric
_VNR-RE12 _VNR-RE12-24
12 16 PG11 18.5 56.0
_VNR-RE1317 _VNR-RE1317-28
17 20 PG13 20.4 65.0
_VNR-RE17 _VNR-RE17-28
17 20 PG16 22.5 65.0
_VNR-RE23 _VNR-RE23-32
23 25 PG21 28.5 71.0
_VNR-RE29 _VNR-RE29-44
29 32 PG29 37.0 71.0
_VNR-RE36 _VNR-RE36-50
36 40 PG36 47.0 84.0
_VNR-RE48 _VNR-RE48-65
48 50 PG48 59.3 90.0
_ = Insert “B” to order black or “S” to order grey.
IP68GT available. Please add “GT” to catalogue no. or insert before clamp size (e.g. BVNR-REM162GT, BVNR-REM162GT24).
(Functional description PMAFIX IP68GT, pages E28E29).
www.tnb.ca E69
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Connection splice with pre-installed
universal safety clips (AFN2)
IP68: Connection splice with oval clips
(OVN2), conduit seal (NVN3)
Temperature range: -40° C to 105° C;
Short term to 160° C
Content of delivery:
IP66: Adapter with pre-assembled
universal safety clips (AFN2)
IP68: Adapter with oval clips (OVN2),
conduit seal (NVN3)
Special Products
VSG Connection Splices for Flexible Conduits
Use in railway vehicle construction and
machine tooling
High-grade formulated polyamide
Self extinguishing
Free from halogens and cadmium
High pullout strength
Fits fine (T) and coarse (G) conduit profiles
AV Conduit Adapters
Use in connection with PMAFIX®/PMAFLEX®
system
High-grade, specially formulated polyamide 6
Very high impact resistance
Allows variable application of the PMAFIX®
system, particularly of PMA® distribution
pieces
High conduit pullout strength
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No.
IP66
Cat. No.
IP68
Fits to Conduit Size Outisde
Diameter (mm)
Overall
Length (mm)
NW Metric
_VSGD-1212GT _VSGR-1212
12 16 23.5 66.0
_VSGD-1717GT _VSGR-1717
17 20 30.0 89.0
_VSGD-2323GT _VSGR-2323
23 25 37.0 103.0
_VSGD-2929GT _VSGR-2929
29 32 44.0 100.0
_VSGD-3636GT _VSGR-3636
36 40 53.0 130.0
_VSGD-4848GT _VSGR-4848
48 50 61.0 136.0
_ = Insert “B” to order black or “S” to order grey.
Cat. No.
IP66, Black
Cat. No.
IP68, Black
Fits to Conduit Size Fits to Conduit Size Overall
Length (mm)
NW Metric NW Metric
BAVD-10/07GT BAVR-10/07
10 12 07 10 43.0
BAVD-12/10GT BAVR-12/10
12 16 10 12 46.0
BAVD-17/10GT BAVR-17/10
17 20 10 12 53.0
BAVD-17/12GT BAVR-17/12
17 20 12 16 54.0
BAVD-23/10GT BAVR-23/10
23 25 10 12 54.0
BAVD-23/12GT BAVR-23/12
23 25 12 16 53.0
BAVD-23/17GT BAVR-23/17
23 25 17 20 62.0
BAVD-29/10GT BAVR-29/10
29 32 10 12 56.5
BAVD-29/12GT BAVR-29/12
29 32 12 16 55.0
BAVD-29/17GT BAVR-29/17
29 32 17 20 61.0
BAVD-29/23GT BAVR-29/23
29 32 23 25 64.0
BAVD-36/29GT BAVR-36/29
36 40 29 32 81.0
BAVD-48/36GT BAVR-48/36
48 50 36 40 88.5
www.tnb.ca
E70
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term 160° C
Temperature range: -40° C to 105° C;
Short term 160° C
Content of delivery:
Abrasion-protection sleeves with assembling
screws
Special Products
RKS Conduit Terminal Sleeves
Used at the end of conduits where no
connectors with threads are necessary
Specially modified polyamide
Self extinguishing
Free from halogens and cadmium
SS/SV Abrasion-Protection Sleeves
Abrasion protection for corrugated conduits
exposed to chafing
High-grade, specially modified polyamide 6
Increase the lifetime of moving conduits
Excellent chafing characteristics
Very good chemical properties
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
Cat. No.
Black
Fits to Conduit
Size NW
Fits to Conduit
Size Metric
Inside
Diameter (mm)
Outside
Diameter (mm)
Dimensions
Length (mm)
RKS-07
710 4.5 12.5 16.0
RKS-10
10 12 8.0 15.5 16.0
RKS-12
12 16 10.0 19.0 20.0
RKS-17
17 20 13.0 24.0 21.0
RKS-23
23 25 20.0 32.0 22.0
RKS-29
29 32 25.0 38.0 22.0
RKS-36
36 40 33.5 46.0 25.0
RKS-48
48 50 45.0 58.0 25.0
RKS-56
56 63 54.0 71.0 28.0
Cat. No.
Black
Fits to Conduit
Size NW
Fits to Conduit
Size Metric
Outside
Diameter (mm)
Dimensions
Length (mm)
BSS-17
17 20 42.0 22.0
BSS-23
23 25 49.0 26.0
BSS-29
29 32 55.0 26.0
BSS-36
36 40 63.0 30.0
BSS-48
48 50 75.0 30.0
BSS-56G
56 90.0 33.0
BSV-70G
70 108.0 60.0
www.tnb.ca E71
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term 160° C
Temperature range: -40° C to 105° C;
Short term 160° C
Temperature range: -45° C to 105° C;
Short term 160° C
Accessories and Tools
AFN2 Universal Safety Clips
Pre-installed in the IP66 and IP68GT range
of connectors
Allow for a quick and easy connection to
PMAFLEX® conduits by just pushing the
conduit into the connector
High-grade formulated polyamide
Self extinguishing
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
OVN2 Oval Clips
Secure the conduit within the PMAFIX®
connectors and distributors
Connections made with a high degree
of safety
High-grade formulated polyamide
Easy to install
Self extinguishing
Free from halogens and cadmium
Fits fine (T) and coarse (G)
conduit profiles
WPS Water-Impact Protection
Increased protection of PMAFIX®ttings
against water jet impact
Meet increased ingress protection
requirements regarding high-pressure/
steam jet cleaning
High-grade, specially formulated polyamide
6, extremely shock resistant
Self extinguishing
Free from halogens and cadmium
Based on PMAFIX®/PMAFLEX® system with
ingress protection of IP68
Additional protection against water jet
impact; increased protection up to IP69K
Two-piece water-impact protection
with click cap
Fits all PMAFLEX® conduit profiles
Cat. No.
IP66, Dark Grey
Fits to
NW
Fits to
Profile
Dimensions
Width (mm)
Dimensions
Length (mm)
Dimensions
Thickness (mm)
AFN2-07GT
7
G + T
14.0 14.0 7.0
AFN2-10GT
10 17.5 17.0 8.0
AFN2-12GT
12 20.5 20.0 7.3
AFN2-17GT
17 26.5 22.0 8.0
AFN2-23GT
23 34.0 27.5 11.8
AFN2-29GT
29 40.5 32.0 11.8
AFN2-36GT
36 49.5 38.8 9.5
AFN2-48GT
48 62.0 47.0 9.5
Cat. No.
IP68, Dark Grey
Fits to
NW
Fits to
Profile
Dimensions
Width (mm)
Dimensions
Length (mm)
Dimensions
Thickness (mm)
OVN2-07
7
G + T
14.0 14.0 6.0
OVN2-10
10 17.5 17.0 7.0
OVN2-12
12 21.0 19.0 6.0
OVN2-17
17 26.5 22.5 7.0
OVN2-23
23 34.0 27.5 10.5
OVN2-29
29 40.5 32.0 10.5
OVN2-36
36 49.5 39.0 8.5
OVN2-48
48 62.0 47.0 8.5
Cat. No.
IP69K, Black
Fits to
NW
Fits to
Profile
Outside
Diameter (mm)
Dimensions
Thickness (mm)
WPS-NW10
10
G + T
22.0 8.0
WPS-NW12
12 26.0 8.0
WPS-NW17
17 33.0 8.0
WPS-NW23
23 40.0 9.0
WPS-NW29
29 47.0 9.5
WPS-NW36
36 59.0 10.0
WPS-NW48
48 71.0 10.0
www.tnb.ca
E72
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C;
Short term 150° C
Temperature range: -40° C to 105° C;
Short term 150° C
Accessories and Tools
MN Hexagonal Locknuts, Metric, Polyamide
High-grade, specially formulated polyamide
6, 30% reinforced fiberglass
High tightening torques
Safe system connection
Very good chemical properties
Free from halogens and cadmium
MN Hexagonal Locknuts, PG,
Polyamide
High-grade, specially formulated polyamide
6, 30% reinforced fiberglass
High tightening torques
Safe system connection
Very good chemical properties
Free from halogens and cadmium
Cat. No.
Black
Cat. No.
Grey
Fits to Thread
Metric
Wrench
Size (mm)
Dimensions
Height Min. (mm)
BMN-M12 GMN-M12
M12x1.5 18.0 5.0
BMN-M16 GMN-M16
M16x1.5 22.0
BMN-M20 GMN-M20
M20x1.5 26.0 6.0
BMN-M25 GMN-M25
M25x1.5 32.0 5.6
BMN-M32 GMN-M32
M32x1.5 41.0 7.0
BMN-M40 GMN-M40
M40x1.5 50.0
BMN-M50 GMN-M50
M50x1.5 60.0 8.0
BMN-M63 GMN-M63
M63x1.5 75.0
Cat. No.
Black
Cat. No.
Grey
Fits to Thread
PG
Wrench
Size (mm)
Dimensions
Height Min. (mm)
BMN-07 GMN-07
7 19.0
5.0
BMN-09 GMN-09
9 22.0
BMN-11 GMN-11
11 24.0
BMN-13 GMN-13
 13.5 27.0 6.0
BMN-16 GMN-16
16 30.0
BMN-21 GMN-21
21 36.0 7.0
BMN-29 GMN-29
29 46.0
BMN-36 GMN-36
36 60.0 8.0
BMN-48 GMN-48
48 70.0
www.tnb.ca E73
Nylon Flexible Conduit Systems
PMA ®
Accessories and Tools
MM Hexagonal Locknuts, Metric, Metal
Brass galvanically nickel plated
Maximum possible torque
Safe system connection
Hexagonal Locknuts, PG, Metal
Brass galvanically nickel plated
Maximum possible torque
Safe system connection
Cat. No.
Metal
Fits to Thread
Metric
Wrench
Size (mm)
Dimensions
Height Min. (mm)
GMM-M12
M12x1.5 15.0 2.8
GMM-M16
M16x1.5 19.0 2.8
GMM-M20
M20x1.5 24.0 3.0
GMM-M25
M25x1.5 30.0 3.5
GMM-M32
M32x1.5 36.0 4.0
GMM-M40
M40x1.5 46.0 4.5
GMM-M50
M50x1.5 60.0 5.0
GMM-M63
M63x1.5 70.0 5.5
Cat. No.
Metal
Fits to Thread
PG
Wrench
Size (mm)
Dimensions
Height Min. (mm)
GMM-07
715.0 2.8
GMM-09
918.0 2.8
GMM-11
11 21.0 3.0
GMM-13
13.5 23.0 3.0
GMM-16
16 26.0 3.0
GMM-21
21 32.0 3.5
GMM-29
29 41.0 4.0
GMM-36
36 51.0 5.0
GMM-42
42 60.0 5.0
GMM-48
48 64.0 5.5
www.tnb.ca
E74
Nylon Flexible Conduit Systems
PMA ®
Accessories and Tools
ME Enlargers, Metric, Brass
Used to enlarge metric threads
Easy mounting, equipped with hexagonal
ring
Brass galvanically nickel plated
For enlargement of an existing thread
MR Reducers, Metric, Brass
Used to reduce metric threads
Available in round and hexagonal form
Brass galvanically nickel plated
Cat. No.
Metal
Standard
Thread Outside Thread Inside Inside
Diameter
(mm)
Total
Length
(mm)
Wrench
Size
Metric Length Metric Length (mm)
M12M16M
M12x1.5 5M16x1.5 7.0 8.0 16.0 18
M16M20M
M16x1.5 5M20x1.5 7.5 12.0 16.5 22
M20M25M
M20x1.5 6M25x1.5 8.0 15.0 18.5 27
M25M32M
M25x1.5 7M32x1.5 9.0 21.0 20.5 34
M32M40M
M32x1.5 8M40x1.5 10.0 26.0 23.5 42
M40M50M
M40x1.5 8M50x1.5 13.0 34.0 30.0 52
M50M63M
M50x1.5 9M63x1.5 16.0 44.0 32.5 65
Cat. No.
Metal Standard
Cat. No.
Metal Hexagonal
Thread Outside
Metric
Thread inside
Metric
M16M12M M16M12M/6
M16x1.5 M12x1.5
M20M12M M20M12M/6
M20x1.5 M12x1.5
M20M16M M20M16M/6
M20x1.5 M16x1.5
M25M16M M25M16M/6
M25x1.5 M16x1.5
M25M20M M25M20M/6
M25x1.5 M20x1.5
M32M20M M32M20M/6
M32x1.5 M20x1.5
M32M25M M32M25M/6
M32x1.5 M25x1.5
M40M25M M40M25M/6
M40x1.5 M25x1.5
M40M32M M40M32M/6
M40x1.5 M32x1.5
M50M32M M50M32M/6
M50x1.5 M32x1.5
M50M40M M50M40M/6
M50x1.5 M40x1.5
M63M40M M63M40M/6
M63x1.5 M40x1.5
M63M50M M63M50M/6
M63x1.5 M50x1.5
www.tnb.ca E75
Nylon Flexible Conduit Systems
PMA ®
Accessories and Tools
ME Enlargers, PG, Brass
Used to enlarge PG threads
Brass galvanically nickel plated
MR Reducers, PG, Brass
Used to reduce PG threads
Brass galvanically nickel plated
Cat. No.
Metal, Standard
Thread Outside Thread Inside Outside
Diameter (mm)
Total
Length (mm)
PG Length (mm) PG Length (mm)
0709M
7.0 5.0 9.0 7.0 17.0 15.0
0911M
9.0 6.0
11.0 20.0 16.5
0913M
13.5 7.5 22.0 17.5
1113M
11.0
13.5 8.0 22.0 17.5
1116M
6.5
16.0 8.5 24.0 19.0
1121M
21.0 10.0 30.0 21.0
1316M
13.5 16.0 7.5 24.0 19.0
1321M
21.0 8.5 30.0 21.0
1621M
16.0 21.0 8.5 30.0 21.0
1629M
29.0 11.0 39.0 22.5
2129M
21.0 7.0 29.0 11.5 39.0 23.0
2936M
29.0 8.0 36.0 12.0 50.0 27.5
4248M
42.0 10.0 48.0 1.0 64.0 33.0
Cat. No.
IP66
Thread Outside Thread Inside Outside
Diameter (mm)
Total
Length (mm)
PG Length (mm) PG
0907M
9.0
6.0
7 17.0
8.5
1107M
11.0 7 20.0
1109M
9
1307M
13.5
6.5
7
22.0 9.0
1309M
9
1311M
11
1607M
16.0
7
24.0 9.5
1609M
9
1611M
11
1613M
 13.5
2111M
21.0 7.0
11
30.0 10.0
2113M
 13.5
2116M
16
2916M
29.0 8.0 16 39.0 11.5
2921M
21
3621M
36.0 9.0 21 50.0 12.5
3629M
29
4229M
42.0
10.0
29 57.0
14.0
4236M
36
4836M
48.0 36 64.0
4842M
42
www.tnb.ca
E76
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 105° C
Temperature range: -40° C to 105° C
Temperature range: -40° C to 105° C
Accessories and Tools
NR Reducers, PG, Polyamide
Reduce connecting threads
Polyamide reinforced fiberglass
NVN3 Sealing Caps, Reinforced, IP68
Connect PMAFIX® connectors
(“V” Series and PMAFLEX® corrugated
conduits)
Specially modified polyesterelastomer
Suitable for sealing
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
NFN3 Sealing Caps, IP67
Connect PMAFIX® connectors (“F” Series
and PMAFLEX® corrugated conduits)
Specially modified polyesterelastomer
Suitable for sealing
Free from halogens and cadmium
Fits fine (T) and coarse (G) conduit profiles
Cat. No. Thread Outside
PG
Thread Inside
PG Length (mm) Outside
Diameter (mm)
1109N
11 918.0 22.5
1309N
13.5 911.5 27.0
1311N
13.5 11 21.5 25.0
1609N
16 913.0 29.0
1611N
16 11 12.5
1613N
16 13.5 24.5 28.5
2113N
21 13.5 13.5 35.5
2116N
21 16 13.5
2921N
29 21 13.5 46.0
3629N
36 29 21.5 54.5
Cat. No.
Black
Fits to Conduit Size
NW
Fits to Conduit Size
Metric Length (mm)
NVN3-07
710 9.0
NVN3-09
10 12
NVN3-11
12 16 12.0
NVN3-16
17 23 16.5
NVN3-21
23 25 13.0
NVN3-29
29 32 14.0
NVN3-36
36 40 17.5
NVN3-48
48 50
Cat. No.
Black
Fits to Conduit Size
NW
Fits to Conduit Size
Metric Length (mm)
NFN3-07
710
9.0
NFN3-09
10 12
NFN3-11
12 16
NFN3-16
17 23
NFN3-21
23 25
NFN3-29
29 32
NFN3-36
36 40 11.0
NFN3-48
48 50
www.tnb.ca E77
Nylon Flexible Conduit Systems
PMA ®
Temperature range: -40° C to 200° C;
Short term 350° C
Temperature range: -40° C to 200° C;
Short term 350° C
Temperature range: -40° C to 200° C;
Short term 350° C
Accessories and Tools
SVN4 Flat Gaskets, Metric
Suitable for the reinforced PMAFIX®
connectors with polyamide or metal threads
Guarantee ingress protection of up to IP68
NBR reinforced with aramide fibers
(asbestos free)
Up to IP68
SVN4 Flat Gaskets, PG
Suitable for the reinforced PMAFIX®
connectors with polyamide or metal threads
Guarantee ingress protection of up to IP68
NBR reinforced with aramide fibers
(asbestos free)
Up to IP68
SVN4 Flat Gaskets, Gas
Suitable for the reinforced PMAFIX®
connectors with polyamide or metal threads
Guarantee ingress protection of up to IP68
NBR reinforced with aramide fibers
(asbestos free)
Up to IP68
Cat. No.
IP68 Fits to Thread PG Inside
Diameter (mm)
Outside
Diameter (mm) Width (mm)
SVN4-07
712.5 16.5
1.5
SVN4-09
915.2 20.0
SVN4-11
11 18.6 24.0
SVN4-13
13.5 20.4 31.0
SVN4-16
16 22.5 31.0
SVN4-21
21 28.3 37.0
SVN4-29
29 37.0 48.0
SVN4-36
36 47.0 57.0
SVN4-42
42 54.0 60.0
SVN4-48
48 59.3 69.0
Cat. No.
IP68 Fits to Thread Metric Inside
Diameter (mm)
Outside
Diameter (mm) Width (mm)
SVN4-M12
M12x1.5 12.0 20.0
1.5
SVN4-M12/02
23.0
SVN4-M16
M16x1.5 16.0 22.0
SVN4-M16/02
25.0
SVN4-M20
M20x1.5 20.0 27.0
SVN4-M20/02
33.0
SVN4-M25
M25x1.5 25.0 35.0
SVN4-M25/02
39.0
SVN4-M32
M32x1.5 32.0 43.0
SVN4-M32/02
49.0
SVN4-M40
M40x1.5 40.0 55.0
SVN4-M40/02
64.0
SVN4-M50
M50x1.5 50.0 69.0
SVN4-M50/02
74.0
SVN4-M63
M63x1.5 63.0 75.0
Cat. No.
IP68 Fits to Thread Gas (in.) Inside
Diameter (mm)
Outside
Diameter (mm) Width (mm)
SVN4-G00
1/4 13.2 20.0
1.5
SVN4-G01
3/8 16.7 22.0
SVN4-G02
1/2 21.0 28.0
SVN4-G04
3/4 26.5 34.0
SVN4-G06
133.3 42.0
SVN4-G07
1-1/4 41.9 53.0
SVN4-G08
1-1/2 47.8 62.0
SVN4-G09
259.6 69.0
www.tnb.ca
E78
Nylon Flexible Conduit Systems
PMA ®
Temperature range: 40° C to 100° C;
Short term 150° C
Temperature range: -40° C to 100° C;
Short term 150° C
Accessories and Tools
514 Plug Screws, Metric
Product with metric thread: PA-GF
Free from halogens and cadmium
IP54
514 Plug Screws, PG
Product with PG thread: PS
Free from halogens and cadmium
Battery: Ni-MH 14.4V 3.0Ah
IP54
Cat. No.
Grey
Fits to Thread
Metric
Outside
Diameter (mm)
Dimensions
Height (mm)
Thread
Length (mm)
514-M12
M12x1.5 15.0 8.0
6.0
514-M16
M16x1.5 20.0 9.0
514-M20
M20x1.5 24.0 9.5
514-M25
M25x1.5 30.0 11.5
8.0
514-M32
M32x1.5 37.0 12.0
514-M40
M40x1.5 46.0 13.0
514-M50
M50x1.5 56.0 15.0 10.0
514-M63
M63x1.5 70.0 17.0 12.0
Cat. No.
Grey
Fits to Thread
Metric
Outside
Diameter (mm)
Dimensions
Height (mm)
Thread
Length (mm)
514-07
715.0 8.0 6.0
514-09
919.0 9.5 6.5
514-11
11 22.0 10.0 6.5
514-13
13.5 25.0 10.0 6.5
514-16
16 27.0 10.0 6.5
514-21
21 33.0 12.0 8.0
514-29
29 44.0 11.5 8.0
514-36
36 55.0 14.0 10.0
514-48
48 68.0 16.0 12.0
www.tnb.ca E79
Nylon Flexible Conduit Systems
PMA ®
Accessories and Tools
PMACUT Cutting Tools
Excellent tool for cutting all PMA® conduits
Guarantees precise and safe 90° angle cut
Material: Metal
Colour: Red
EWZ Draw-In Tools
Suitable for drawing in cables or wires into
PMA® COFLEX or other slit conduits
Designed in a handy shape and are equip-
ped with a practical hand grip for wedging
or with hole for direct holding of the wires
Can be used whenever a drawing-in assis-
tance for slit conduits is helpful
Material: Polyamide
Colour: Black
Cat. No.
Cutting Tool
Cat. No.
Spare Blade
Cutting
Range (mm)
For Pmaflex
NW
PMACUT-38
FP-38 0–38 7–29
PMACUT-52
FP-52 0–52 23–48
Cat. No.
Black with Holes
Cat. No.
Black with Handle
Fits to
Conduit Size NW
Dimensions (mm)
Width x Length x Depth
EWZ-02 EWZ-03
7.5–34 117.7 x 45.2 x 71.9
www.tnb.ca
E80
Nylon Flexible Conduit Systems
PMA ®
Hazardous Location ATEX Systems
ATEX 95
Polyamide Cable Protection:
30 years of experience, now ATEX 95 certified
Products for the protection of cables, wires and hoses against not
only mechanical damage but also the influences of UV radiation,
weathering and chemicals
Products made of specially modified, load-discharging polyamide
materials (PA11, PA12) for use in explosion- endangered zones
1/2 (gas) and 21/22 (dust)
ATEX marking:
Identical in function to the standard product range
PMAFIX®/PMAFLEX® (successfully used in applications as
railway, machinery, automation, etc., more than 30 years)
Two sealing systems fulfilling IP66 or IP68
System safety: For security reasons, re-opening is only
possible with the use of a screwdriver
Flexible conduits, excellent for applications with continual
reversed bending
Quick and simple installation, reduced total installation
costs (compared to other explosion-proof cable
protection systems)
No corrosion, long service life
Low weight
Area of Application
PMA® Ex-System products constitute an equipment group II category
2G device in accordance with Directive 94/9/EC (ATEX 95) Appendix
I which may be implemented in zones 1/2 as well as in gas groups
IIA, IIB and IIC which are subject to explosion risk due to combustible
substances, in accordance with Directive 99/92/EC (ATEX 137).
The requirements in accordance with EN 60079-14 shall be adhered
to on use/installation.
The products constitute an equipment group II category 2D device in
accordance with Directive 94/9/EC (ATEX 95) Appendix I which may
be implemented in zones 21/22 with ex plosive air/dust mixtures in
accordance with Directive 99/92/EC (ATEX 137). The requirements in
accordance with EN 60079-14 shall be adhered to on use/installation.
Operation, Service and Maintenance
The defined ambient and operating temperature range is -20° C to
+85° C and -40° C to +85° C for the conduit type XESX (temperature
range for electrical equipment in accordance with EN 60079-0).
A visual examination of the cable protection system shall be
performed in periodic maintenance of systems and components, but
no later than every 5 years. In the event of visible damage (holes,
cracks, signs of heavy wear) to conduits, fittings or accessories,
the damaged parts shall be replaced. (In the event of apparent
mechanical damage, it shall be ensured that no incorrect handling
takes place.)
Only ATEX-approved original PMA® parts shall be used for the
replacement of ATEX approved parts.
These operating and assembly instructions include important
information for service and maintenance and should therefore be
retained.
Assembly
To ensure the discharge of electrical currents and thus to ensure
antistatic behaviour, ATEX-approved PMA® conduits shall be used
exclusively in combination with special PMA® connectors and
accessories which are also ATEX-approved. These connectors and
accessories (seals, fasteners) are also made of discharging material
and are designated with the conformity marking.
The ATEX approved connectors or accessories shall always be in
direct contact with a metallic surface (ground). No insulating materials
(e.g. adhesives) and no components which are not ATEX approved
shall be used between the discharging plastic parts or
between plastic parts and metal surfaces.
CE 1258 II 2G Ex eb IIC SEV 05 ATEX 0105 II 2D Ex tb IIIC
www.tnb.ca E81
Nylon Flexible Conduit Systems
PMA ®
XESX-Index
min. max.
ductility
fatigue-reversed bending
compression resistance
low-temperature performance
weathering resistance
Specially modified polyamide and
polyethylene
Electrostatic discharging
Free from halogens and cadmium
Very high mechanical load capacity and
low-temperature impact strength
Very good UV-resistance
High abrasion resistance
Highest dynamic load capacity
Very good chemical properties
Temperature range: -50° C to +90° C
continuous; +150° C short-term; -40° C
to +85° C (for ATEX use)
Hazardous Location ATEX Systems
ATEX Multilayer Conduits
The PMA® EX-system is suitable for the protection of cables, wires and hoses against
mechanical damage, UV radiation and weathering in explosion-endangered areas classified as
zones 1/2 (gas) and 21/22 (dust) according to ATEX 137.
The multilayer conduit offers electrostatic load-discharging properties and comes with a range
of compatible ATEX approved fittings and installation accessories.
XESX Highly Flexible, Medium Wall
The PMA® Ex-System multilayer conduit type XESX offers an electrostatically discharging
property, very high mechanical load capacity and low-temperature impact strength. Excellent
UV and weathering resistance allow outdoor installation exposed to constant sunlight.
Cat. No.
Black
Conduit Size
NW
Rec. Fitting
Thread Metric
Inside
Diameter
Outside
Diameter (mm)
Stat.
Radius* (mm)
PU
Meter
XESXT-12BY
12 M16/M20 11.8 15.6 30/70 50
XESXG-17BY
17 M20/M25 15.2 21.0 35/85 50
XESXG-23BY
23 M25/M32 22.0 28.5 40/110 50
XESXG-29BY
29 M32/M40 27.5 34.4 50/130 50
XESXG-36BY
36 M40/M50 35.8 42.4 60/180 30
XESXG-48BY
48 M50/M63 46.8 54.4 70/220 30
For actual cat. number, add PU METER at the end. Example: XESXT-12BY.50
Fine profile T
Tight bending raduis
Coarse profile G
High pullout strength
**† stat. R = lowest recommended
bending radius for static
(fixed) installation.
www.tnb.ca
E82
Nylon Flexible Conduit Systems
PMA ®
PMA® Ex-System connectors together with PMA® Ex-System protection conduits are used for
flexible protection of cables, wires and hoses against mechanical damage, UV radiation and
weathering in explosion-endangered areas classified as zones 1/2 (gas) and 21/22 (dust)
according to ATEX 137.
Connectors are available with ingress protection up to and including IP66 or IP68.
IP66 connectors are fitted with a pre- in stalled universal safety clip which ensu res a quick
push-in installation of the conduit.
IP68 connectors for increased requirements will be delivered with a special conduit sealing cap.
IP66
IP66 static
IP54 dynamic
One-piece fitting, conical sealing method
Easy push-in installation
Pre-installed safety clip AFN2
Fits any type of conduit profile (T and G)
Excellent pullout strength
For safety reasons, re-opening is only possible with a screwdriver
IP68
IP68 static
IP67 dynamic
High sealing through additional seal cap
For highest dynamic appli cations
Fits any type of conduit profile (T and G)
Excellent pullout strength
For safety reasons, re-opening is only possible with a screwdriver
Hazardous Location ATEX Systems
ATEX Connectors
www.tnb.ca E83
Nylon Flexible Conduit Systems
PMA ®
IP66
Installation of IP66 Safety System
A.Conduit
B.Fitting
C.Universal safety clip Straight cut of conduit (A). PUsh in the conduit (A) with a slight twist until the
stop.
PUll back the conduit (A) slightly to ensure the
locking mechanism is fully engaged.
To re-open use a screw driver. The screwdriver slot
at the oval clip (C) must point towards the conduit.
If bending the conduit, please maintain the
recommended bending radius.
Installation of IP68 Safety System
IP68
A.Conduit
B.Ex Seal cap (yellow)
C.Fitting
D.Oval clip
E.Thread seal
(O-ring or flat seal) Straight cut of conduit (A). PUsh seal cap (B) com pletely onto conduit in order
to achieve IP68.
Place seal (E) onto fitting thread (C) and screw in. PUsh conduit with seal cap (A+B) into the fitting
until seal cap is no longer visible in the locking
element window.
1 2 3
123
45 6
456
A
A
C + E
A + B
B
C
D
E
Hazardous Location ATEX Systems
A
B
C
Insert oval clip (D) in locking element window
and click into place. The screwdriver slot must
point towards the conduit. To re-open, use a
screwdriver.
www.tnb.ca
E84
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
These PMA® Ex-System connectors allow a quick
push-in installation of PMA® Ex-System conduits.
EAD 45° Elbow, Metric, IP66
These PMA® Ex-System connectors allow a quick
push-in installation of PMA® Ex-System conduits.
Cat. No.
IP66
Thread Size
Metric
Fit to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BEND-M120GT
M12x1.5 10 12
11.0
36.5
BEND-M160GT
M16x1.5 10 12
BEND-M162GT
M16x1.5 12 16 39.5
BEND-M202GT
M20x1.5 12 16
BEND-M207GT
M20x1.5 17 20 47.5
BEND-M257GT
M25x1.5 17 20 12.0 48.5
BEND-M253GT
M25x1.5 23 25 52.0
BEND-M323GT
M32x1.5 23 25 15.0 55.5
BEND-M329GT
M32x1.5 29 32 56.0
BEND-M409GT
M40x1.5 29 32
19.0
60.0
BEND-M406GT
M40x1.5 36 40 72.5
BEND-M506GT
M50x1.5 36 40 72.0
BEND-M508GT
M50x1.5 48 50 72.5
BEND-M638GT
M63x1.5 48 50 72.0
Cat. No.
IP66
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BEAD-M120GT
M12x1.5 10 12
11.0
43.5 x 37.0
BEAD-M160GT
M16x1.5 43.5 x 38.0
BEAD-M162GT
M16x1.5 12 16 48.0 x 40.0
BEAD-M202GT
M20x1.5 48.0 x 41.5
BEAD-M207GT
M20x1.5 17 20 55.5 x 51.5
BEAD-M253GT
M25x1.5 23 25 12.0 65.0 x 58.5
BEAD-M329GT
M32x1.5 29 32 15.0 73.5 x 66.5
BEAD-M406GT
M40x1.5 36 40
19.0
92.5 x 85.5
BEAD-M506GT
M50x1.5 92.5 x 89.5
BEAD-M508GT
M50x1.5 48 50 100.0 x 96.0
BEAD-M638GT
M63x1.5 100.0 x 104.0
Hazardous Location ATEX Systems
END Straight, Metric, IP66
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
www.tnb.ca E85
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
These PMA® Ex-System connectors allow a quick
push-in installation of PMA® Ex-System conduits.
EWD 90° Elbow, Metric, IP66
These PMA® Ex-System connectors allow a quick
push-in installation of PMA® Ex-System conduits.
Cat. No.
IP66
Thread Size
Metric
Fit to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BEBD-M207GT
M20x1.5 17 20 11.0 47.5 x 73.0
BEBD-M257GT
M25x1.5 20 12.0 48.5 x 76.0
BEBD-M253GT
M25x1.5 23 25 57.5 x 83.0
BEBD-M323GT
M32x1.5 25 15.0 61.0 x 87.5
BEBD-M329GT
M32x1.5 29 21 70.5 x 93.0
BEBD-M409GT
M40x1.5 29 32
19.0
74.5 x 98.5
BEBD-M406GT
M40x1.5 36 40 85.0 x 121.0
BEBD-M506GT
M50x1.5 36 40 85.0 x 125.0
BEBD-M508GT
M50x1.5 48 50 98.5 x 130.0
BEBD-M638GT
M63x1.5 48 50 98.5 x 138.0
Cat. No.
IP66
Thread Size
Metric
Fit to Conduit Size Thread
Length (mm)
Overall
Length (mm)
NW Metric
BEWD-M120GT
M12x1.5 10 12
11.0
34.0 x 39.5
BEWD-M160GT
M16x1.5 34.0 x 40.5
BEWD-M162GT
12 16 38.5 x 46.0
BEWD-M202GT
M20x1.5 38.5 x 47.5
Hazardous Location ATEX Systems
EBD 90° Curved Elbow, Metric, IP66
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
www.tnb.ca
E86
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Thread made of nickel-plated brass
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Specially modified electrostatic-discharging
polyamide
Strain-relief socket made of nickel-plated
brass, sealing insert TPE-V
With corresponding seals IP68 static / IP67
dynamic cable = IP68 (10 bar)
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
The metal thread and the sealing up to IP68
allow use of these PMA® Ex-System fittings in
applications with increased requirements.
ENZ Straight with Strain Relief, Metric, Metal Thread, IP68
The metal thread and the sealing up to IP68
allow use of these PMA® Ex-System fittings in
applications with increased requirements. Due to
the integrated Pflitsch insert, cables are held and
at the same time sealed up to IP68 (10 bar).
Furthermore, these connectors can be used
where damp and dry areas have to be separated.
Cat. No.
IP68
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NENV-M120-10
M12x1.5 10 12
10.0
40.0
NENV-M160-10
M16x1.5 10 12
NENV-M162-10
M16x1.5 12 16 43.0
NENV-M202-10
M20x1.5 12 16
NENV-M207-10
M20x1.5 17 20 51.0
NENV-M257-11
M25x1.5 17 20 11.0 52.0
NENV-M253-11
M25x1.5 23 25 54.0
NENV-M323-13
M32x1.5 23 25
13.0
56.0
NENV-M329-13
M32x1.5 29 32 57.3
NENV-M409-13
M40x1.5 29 32
NENV-M406-13
M40x1.5 36 40 71.4
NENV-M506-14
M50x1.5 36 40
14.0 72.4
NENV-M508-14
M50x1.5 48 50
NENV-M638-14
M63x1.5 48 50
Cat. No.
IP68
Terminal
Range (mm)
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NENZ-M120S/P1
4.5–6.0
M12x1.5
10 12
5.0 48.5
NENZ-M120S/P2
5.0–8.0
NENZ-M120S/P3
6.5–9.5
NENZ-M160S/P1
4.0–6.5
M16x1.5 6.0 49.5
NENZ-M160S/P2
5.0–8.0
NENZ-M160S/P3
6.5–9.5
NENZ-M202S/P1
4.0–6.5
M20x1.5
12 16
6.5
54.0
NENZ-M202S/P3
6.5–9.5
NENZ-M202S/P4
7.0–10.5
NENZ-M207S/P3
6.5–9.5
17 20
60.0
NENZ-M207S/P4
7.0–10.5
NENZ-M207S/P5
9.0–13.0
NENZ-M257S/P5
9.0–13.0 M25x1.5 7.5 61.5
NENZ-M257S/P6
11.5–15.5
NENZ-M323S/P4
14.0–18.0 M32x1.5 23 25
8.0 73.0
NENZ-M323S/P5
17.0–20.5
NENZ-M409S/P4
20.0–25.0 M40x1.5 29 32
NENZ-M409S/P5
24.0–28.0
NENZ-M506S/P1
27.0–32.0
M50x1.5
36 40
10.0
89.5
NENZ-M506S/P3
32.0–36.0
NENZ-M508S/P2
32.0–36.0
48 50
92.0
NENZ-M508S/P3
36.0–40.0
NENZ-M638S/P1
35.0–40.0 M63x1.5 90.5
NENZ-M638S/P2
39.0–44.0 4
Hazardous Location ATEX Systems
ENV Straight, Metric, Metal Thread, IP68
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Content of delivery:
Complete: Fitting with oval clips (OVN2),
Pflitsch sealing insert (DE), conduit seal
(NEN3), O-ring (OR)
www.tnb.ca E87
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Thread made of nickel-plated brass
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Specially modified electrostatic-discharging
polyamide
Thread made of nickel-plated brass
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
Specially modified electrostatic-discharging
polyamide
Thread made of nickel-plated brass
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Extremely high thread and system
connection strength
The metal thread and the sealing up to IP68
allow use of these PMA® Ex-System fittings in
applications with increased requirements.
EBV 90° Curved Elbow, Metric, Metal Thread, IP68
The metal thread and the sealing up to IP68
allow use of these PMA® Ex-System fittings in
applications with increased requirements.
EWV 90° Elbow, Metric, Metal Thread, IP68
The metal thread and the sealing up to IP68
allow use of these PMA
®
Ex-System fittings in
applications with increased requirements.
Cat. No.
IP68
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NEAV-M120-10
M12x1.5 10 12
10.0
48.5 x 37.0
NEAV-M162-10
M16x1.5 12 16 53.0 x 40.5
NEAV-M207-10
M20x1.5 17 20 60.5 x 51.5
NEAV-M257-11
M25x1.5 11.0 61.5 x 54.5
NEAV-M253-11
M25x1.5 23 25 70.0 x 60.5
NEAV-M323-13
M32x1.5
13.0
72.0 x 64.5
NEAV-M329-13
M32x1.5 29 32 77.0 x 68.0
NEAV-M409-13
M40x1.5 77.0 x 73.0
NEAV-M406-13
M40x1.5 36 40 94.0 x 87.5
NEAV-M506-14
M50x1.5
14.0
95.0 x 92.5
NEAV-M508-14
M50x1.5 48 50 102.0 x 101.0
NEAV-M638-14
M63x1.5 102.0 x 104.0
Cat. No.
IP68
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NEBV-M207-10
M20x1.5 17 20 10.0 51.0 x 73.0
NEBV-M257-11
M25x1.5 11.0 52.0 x 76.0
NEBV-M253-11
23 25 62.5 x 85.0
NEBV-M323-13
M32x1.5
13.0
64.5 x 89.0
NEBV-M329-13
29 32 74.0 x 94.5
NEBV-M409-13
M40x1.5 75.5 x 100.5
NEBV-M406-13
36 40 86.5 x 123.0
NEBV-M506-14
M50x1.5 14.0
87.5 x 130.0
NEBV-M508-14
48 50 100.5 x 135.0
NEBV-M638-14
M63x1.5 100.5 x 138.0
Cat. No.
IP68
Thread
Metric
Fit to Conduit Size Thread
Length (mm)
External
Dimensions (mm)
NW Metric
NEWV-M120-10
M12x1.5 10 12
10.0
37.5 x 39.5
NEWV-M160-10
M16x1.5 37.5 x 41.5
NEWV-M162-10
12 16 42.0 x 46.5
NEWV-M202-10
M20x1.5 42.0 x 49.0
Hazardous Location ATEX Systems
EAV 45° Elbow, Metric, Metal Thread, IP68
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
www.tnb.ca
E88
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Clamp made of stainless steel
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Hazardous Location ATEX Systems
ENR-REM Connection to Solid Metal Tube
With these products, solid metal tubes can easily
and quickly be connected with flexible PMA®
Ex-System conduits. The connection is fixed onto
the solid tube with a jubilee clip made of stainless
steel.
ESGD/ESGR Splice Connector
These PMA® connection splices are used for an
optimum connection of PMA® Ex-System conduits
and enable the highest grade of safety and
sealing.
EYD/EYR Y Piece
These PMA® Ex-System junctions allow the split-
ting of cable looms and rerouting of the split looms
into different directions.
Cat. No.
IP66
Cat. No.
IP68
Input Fit to Conduit Size Outputs Fit to Conduit Size
NW Metric NW Metric
BEYD-12/10GT BEYR-12/10
12 16 10 12
BEYD-17/12GT BEYR-17/12
17 20 12 16
BEYD-23/17GT BEYR-23/17
23 25 17 20
BEYD-29/23GT BEYR-29/23
29 32 23 25
BEYD-36/29GT BEYR-36/29
36 40 29 32
BEYD-48/36GT BEYR-48/36
48 50 36 40
Cat. No.
IP66
Cat. No.
IP68
Input Fit to Conduit Size External
Dimensions (mm)
NW Metric
BESGD-1212GT BESGR-1212
12 16 66.0
BESGD-1717GT BESGR-1717
17 20 89.0
BESGD-2323GT BESGR-2323
23 25 103.0
BESGD-2929GT BESGR-2929
29 32 100.0
BESGD-3636GT BESGR-3636
36 40 130.0
BESGD-4848GT BESGR-4848
48 50 136.0
Cat. No.
Without Jubilee Clip, IP68
Cat. No.
With Jubilee IP68
Input Fit to Conduit Size External
Dimensions (mm)
NW Metric
BENR-REM162 BENR-REM162-24
12 M16 54.0
BENR-REM207 BENR-REM207-28
17 M20 65.0
BENR-REM253 BENR-REM253-32
23 M25 71.0
BENR-REM329 BENR-REM329-44
29 M32 71.0
BENR-REM406 BENR-REM406-50
36 M40 90.0
BENR-REM508 BENR-REM508-65
48 M50 90.0
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
www.tnb.ca E89
Nylon Flexible Conduit Systems
PMA ®
High-grade, specially modified polyamide 12
Electrostatically discharging
Extremely shock resistant
Free from halogens and cadmium
Very good chemical properties
High-grade, specially modified polyamide 12
Electrostatically discharging
Very high impact resistant
Free from halogens and cadmium
Very good chemical properties
These PMA® Ex-System junctions allow the
splitting of cable looms and rerouting of the split
looms into different directions.
EAVD/EAVR Conduit Adapter
PMA® Ex-System conduit adapters allow variable
applications of conduit sizes within the PMA®
Ex-System, particularly with PMA® Ex-System
junctions.
Cat. No.
IP66
Cat. No.
IP68
Input Fit to Conduit Size Outputs Fit to Conduit Size
NW Metric NW Metric
BEAVD-12/10GT BEAVR-12/10
12 16 10 12
BEAVD-17/12GT BEAVR-17/12
17 20 12 16
BEAVD-23/17GT BEAVR-23/17
23 25 17 20
BEAVD-29/23GT BEAVR-29/23
29 32 23 25
BEAVD-36/29GT BEAVR-36/29
36 40 29 32
BEAVD-48/36GT BEAVR-48/36
48 50 36 40
Cat. No.
IP66
Cat. No.
IP68
Input Fit to Conduit Size Outputs Fit to Conduit Size
NW Metric NW Metric
BETD-101010GT BETR-101010
10 12 10 12
BETD-121212GT BETR-121212
12 16 12 16
BETD-171717GT BETR-171717
17 20 17 20
BETD-232323GT BETR-232323
23 25 23 25
BETD-292929GT BETR-292929
29 32 29 32
BETD-363636GT BETR-363636
36 40 36 40
BETD-484848GT BETR-484848
48 50 48 50
Hazardous Location ATEX Systems
ETD/ETR T Piece
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
NEW!
NEW!
NEW!
NEW!
www.tnb.ca
E90
Nylon Flexible Conduit Systems
PMA ®
Nickel-plated aluminum
Up to IP68 in connection with the
PMAFIX® product range
Thread 1: on casing side, Thread 2:
on conduit side
At thread 2 PMAFIX® fittings straight and
elbows may be applied; also standard cable
glands may be applicable for screened
cables depending on final use
Low transfer impedances
36Clamping effect: High degree of safety
in case of short-circuiting
Hazardous Location ATEX Systems
HEAK EMC Connector
This PMA® Ex-System EMC connector can be
used together with PMA® tinned copper braids
and PMA® Ex-System conduits and connectors
to provide shielding against electromagnetic
interference in explosion-endangered areas.
Cat. No.
IP68, IP68
Thread metric Fits to
NW
Fits to
F.CK
Fits to
F.CU
ID min.
(mm)
Thread
Length (mm)
Overall
Length (mm)
1 2
HEAK-M32/25-13
M32x1.5 M25x1.5 23 20 20 16.8 13.0 42.0
HEAK-M40/32-13
M40x1.5 M32x1.5 29 20/(25) 22.4 51.0
HEAK-M50/40-14
M50x1.5 M40x1.5 36 30/(35) 40 32.4 14.0 58.0
HEAK-M63/63-14
M63x1.5 M63x1.5 48 35 43.4 57.5
Content of delivery includes blue shaded products.
Content of delivery includes shaded products.
Thread 2 Thread 1 Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
NEW!
NEW!
www.tnb.ca E91
Nylon Flexible Conduit Systems
PMA ®
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Specially modified electrostatic-discharging
polyamide
Self-extinguishing
Free from halogens and cadmium
Excellent impact strength
Useable with standard rails type C
Brass galvanically nickel-plated
Maximum possible torque
Safe system connection
The one-piece PMA® Ex-System support is
designed for the fixation of PMA® Ex-System
corrugated conduits in explosion-endangered
zones 1/21 (gas/dust) according to ATEX 137.
EPS One-Piece System Support
The one-piece system supports offer clasps for
easy pre-mounting and final assembly, fixation
on standard rails type C and strain relief due to
gripping around the conduit. In addition, these
products are partially stackable.
Hexagonal Locknuts, Metric, Metal
These hexagonal locknuts are suitable for a wide
range of applications. Maximum possible torques
guarantee a safe connection of the system.
Cat. No. Fits to Conduit Size Dimensions (mm)
Width x Height x Depth Fixing Screw
NW Metric
BEH-10-0
10 12 20.5 x 24.5 x 20.0 1 x M5
BEH-12-0
12 16 24.0 x 27.0 x 20.0 1 x M5
BEH-17-0
17 20 30.0 x 34.0 x 20.0 1 x M6
BEH-23-0
23 25 38.5 x 42.0 x 20.0 1 x M6
BEH-29-0
29 32 45.5 x 48.0 x 20.0 1 x M6
BEH-36-0
36 40 55.5 x 56.0 x 20.0 1 x M6
BEH-48-0
48 50 67.5 x 68.0 x 20.0 1 x M6
Cat. No. Fits to Conduit Size Dimensions (mm)
Width x Height x Depth
NW Metric
BEPS-17
17 20 70.0 x 51.0 x 30.0
BEPS-23
23 25 70.0 x 51.0 x 30.0
BEPS-29
29 32 85.0 x 65.0 x 30.0
BEPS-36
36 40 85.0 x 65.0 x 30.0
BEPS-48
48 50 115.0 x 92.5 x 30.0
Cat. No. Fits to Thread Metric Wrench Size (mm) Dimensions Height Min. (mm)
GMM-M12
M12x1.5 15.0 2.8
GMM-M16
M16x1.5 19.0 2.8
GMM-M20
M20x1.5 24.0 3.0
GMM-M25
M25x1.5 30.0 3.5
GMM-M32
M32x1.5 36.0 4.0
GMM-M40
M40x1.5 46.0 4.5
GMM-M50
M50x1.5 60.0 5.0
GMM-M63
M63x1.5 70.0 5.5
Hazardous Location ATEX Systems
EH-0 One-Piece System Support
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
Temperature range: -50° C to +90° C
(material limits); -20° C to +85° C (for ATEX use)
www.tnb.ca
E92
Nylon Flexible Conduit Systems
PMA ®
Conformance with standards:
Additional services to benefit you
PMA® products conform to worldwide standards and regulations.
As a pioneer in the field of cable protection, we have al ways given
high priority to our own testing facilities, and we have consciously
introduced stringent in-house standards. This approach has
enabled us to exercise a significant influence on the development of
international standards. Standards committees with responsibility
for cable systems regularly ask our company to provide advice or
participate as an active member.
High quality products from A–Z
From basic items to high-tech products, all of our products meet the
most strin gent quality requirements. Some of their outstanding
features include:
Resistance to temperature, weathering, UV radiation
and chemical agents
High system pullout resistance
Excellent fire protection characteristics
(flammability, smoke density, and toxicity)
Excellent system ingress protection up to IP69K
Extremely long service life
Conformance to the EN ISO 9001:2000 quality standard
Technical Information
Testing Methods
www.tnb.ca E93
Nylon Flexible Conduit Systems
PMA ®
Reversed Bending
Test with Swinging
Movements
DO 9.21-4425 IEC EN 61386
This standard is based on a cyclic reversed bending
test (pivoting) of conduits under various conditions
(temperature). The conduits are dynamically loaded and
evaluated at the upper and lower applicationtemperature
limits. The test is performed based on IEC EN 61386. The
minimum requirement corresponds to the specifications
of IEC EN 61386. For PMA®, the test is not considered
completed for final evaluation until cracking or fracture.
The number of cycles to fracture determines the fatigue
strength of the conduit.
Reversed Bending Test
DO 9.21-4420
This standard describes a cyclic reversed
bending test with additional tensile loading
(lifting) on flexible conduits under standard
ambient conditions (23° C/50% relative
humi-dity). The conduit is loaded until
fracture. The number of cycles to fracture
determines the fatigue strength of the
conduit.
Reversed Bending Test
DO 9.21-4220
This standard describes a cyclic bending
test (rotation in an oval pattern) on flexible
conduits under standard ambient conditions
(23° C/50% relative humidity). The conduit is
tested until failure. The number of cycles to
fracture determines the fatigue strength of
the conduit.
Technical Information
www.tnb.ca
E94
Nylon Flexible Conduit Systems
PMA ®
Peak Load Test
DO 9.21-4320 IEC EN 61386
This standard describes the peak load test on
conduits under standard ambient conditions
(23° C/50% relative humidity). The conduit is
deformed by a defined amount between two
plates. The restoring force established over
a specific time (by relaxation of the conduit)
describes the crushing pressure or
compressive strength.
Pullout Test
DO 9.21-4610 IEC EN 61386
This standard defines the system pullout test
on conduits and connectors under standard
ambient conditions (23° C/50% relative
humidity). The conduits are mounted with the
appropriate system connectors. The pullout
strength of the system is determined in a
tensile test.
Impact Test
DO 9.21-4330 IEC EN 61386
This standard describes the impact strength test
on conduits at various temperatures.
The specimen is placed on a steel plate,
centered under an impact head with a defined
profile. The impact head impacts the center of
the specimen surface. In contrast to international
specifications, deformation behavior (buckling)
is determining rather than fracture behavior.
The impact test is considered to be passed if no
fracture or cracking can be detected after the
impact, as well as no excessive permanent
deformation of the conduit in accordance with
PMA® specifications.
Technical Information
www.tnb.ca E95
Nylon Flexible Conduit Systems
PMA ®
Cold Bending Test
DO 9.21-4380
This standard describes a bending test on
conduits at low temperatures. The specimens
are stored in a controlled-climate cabinet at
the specified test temperature. Loading is
achieved by winding the specimen around a
test mandrel with a defined diameter.
The various products are classified based on
the mandrel diameter which can be achieved.
Thermal Aging Test
DO 9.21-4360
This standard describes a bending test on
thermally aged specimens.The test conduits
are stored in a controlled-climate oven at
the specified test temperature. After removal
from the oven, they are cooled to room
temperature. Loading is achieved by winding
the specimen around a test mandrel with a
defined diameter. The various products are
classified based on the mandrel diameter
which can be achieved.
Self-Extinguishing Test
DO 9.21-4430 IEC EN 61386
This standard describes a flame test on
conduits based oninternational specifications.
The conduit is exposed to a defined flame
from a standard burner. The time of ignition,
flame propagation behavior as well as time
of extinguishing after removal of the flame
source are significant parameters for
evaluating the flame behavior of the
products.
Technical Information
www.tnb.ca
E96
Nylon Flexible Conduit Systems
PMA ®
Ingress Protection (IP)
A standard to classify product
performance regarding ingress protection.
Different number —
different protection!
For example, products classified as
IPx8 are not automatically protected
against jet water! Immersion tests
for classifications IPx7 and IPx8 differ
from the tests for protection against
jet water for IPx6, IPx5 or IPx4.
Therefore, PMA® cable protection
systems are tested regarding different
sealing requirements.
PMA® products offer complete protection!
Technical Information
Ingress Protection (IP)
according to EN 60529/DIN 40050
The first digit stands
for Protection against
dust
IP 6 8
Protection against contact and penetration of foreign objects
Degree of protection (contact/foreign bodies)
0
No protection
No contact protection, no protection against solid particles and bodies.
1
Protection against large foreign bodies
Protection against large contact area with hands and foreign bodies with Ø > 50 mm.
2
Protection against medium foreign bodies
Protection against contact with fingers, protection against foreign bodies Ø > 12.5 mm.
3
Protection against small foreign bodies
Protection against tool contact foreign bodies, wires or the like with Ø > 2.5 mm.
4
Protection against foreign grains
See 3, but Ø > 1 mm.
5
Dust protected
Full contact protection. Protection against dust deposits inside.
6
Dust tight
Full contact protection. Protection against dust penetration.
Compliance certified by an independent test laboratory.
Official approval documents available on request. Please contact your Regional Sales Office.
www.tnb.ca E97
Nylon Flexible Conduit Systems
PMA ®
Protection against fluids
Degree of protection (water)
0
No protection
No protection against water.
1
Protection against large foreign bodies
Protection against vertical water drops.
2
Protection against medium foreign bodies
Protection against inclined water drops (any angle up to 15° to vertical line).
3
Protection against small foreign bodies
Protection against spray water from an angle of 60° to vertical line.
4
Protection against foreign grains
Protection against splash water from all directions.
5
Dust protected
Protection against water jets from any angle.
6
Dust tight
Protection against powerful water jets from any angle.
7
Protection against iersion
Protection against water penetration 1m below water.
8
Protection against submersion
Protection against pressure water for an indefinite time (customer tailored).
9k
Protection against high-pressure cleaning
Protection against water from any angle with high pressure.
The second digit
stands for Protection
against water
IP 6 8
PMA
®
Products
PMAFIX
Pro
PMAFIX
IP68 + WPS
PMAFIX
IP68/IP68GT
PMAFIX
IP66 SMART-LINE ECONOMY II ECONOMY
IPx4
Splash water from all directions
√√√√√√√
IPx5
Jet water at any angle
√√√√√√√
IPx6
Powerful jet water from any angle
√√√√√√√
IPx7
Submersion (1m, 30 min.)
√√√
IPx8
Submersion at time and pressure >IPx7
√√√
IPx9K
High-pressure (up to 80 bar) water from any angle
√* √* √* √*
* EN 60529/DIN 40050 can be fulfilled without WPS (Water impact protection ring).
PMA
®
recommends the use of the WPS ring for trouble-free practical applications.
Technical Information
www.tnb.ca
E98
Nylon Flexible Conduit Systems
PMA ®
EN 60423
Metric Pitch Major Ø D1 Major Ø D2 Hole -0/+0.3
12 1.5 12 10.16 12.0
16 1.5 16 14.16 16.0
20 1.5 20 18.16 20.0
25 1.5 25 23.16 25.0
32 1.5 32 30.16 32.0
40 1.5 40 38.16 40.0
50 1.5 50 48.16 50.0
63 1.5 63 61.16 63.0
DIN 40430
PG Pitch Major Ø D1 Major Ø D2 Hole
07 1.270 12.5 11.28 12.7
09 1.411 15.2 13.86 15.4
11 1.411 18.6 17.26 18.8
13 1.411 20.4 19.06 20.7
16 1.411 22.5 21.16 22.8
21 1.588 28.3 26.78 28.6
29 1.588 37.0 35.48 37.4
36 1.588 47.0 45.48 47.5
48 1.588 59.3 57.78 59.8
DIN 259 Bl. 3, ISO 228/I
Gas (in.) Pitch Major Ø D1 Major Ø D2 Hole
1/4 1.337 13.157 11.445 13.4
3/8 1.337 16.662 14.950 17.0
1/2 1.814 20.955 18.631 21.3
3/4 1.814 26.441 24.117 26.8
12.309 33.249 30.291 33.7
1-1/4 2.309 41.910 38.952 42.4
1-1/2 2.309 47.803 44.845 48.31
22.309 59.614 56.656 60.2
Metric Fine Thread
PG Thread
Gas Pipe Thread
60°
ØD2
ØD1
pitch
ØD2 ØD1
80°
pitch
ØD2
ØD1
55° pitch
Technical Information
Thread Dimensions
www.tnb.ca E99
Nylon Flexible Conduit Systems
PMA ®
NSI B2.1/ANSI B2.2
NPT (in.) Pitch Major Ø D1 Hole D2
1/4 1.411 13.616 13.9
3/8 1.411 17.055 17.4
1/2 1.814 21.223 21.6
3/4 1.814 26.568 26.9
12.209 33.227 33.7
1-1/4 2.209 41.984 42.4
1-1/2 2.209 48.053 48.5
22.209 60.091 60.6
Comparison table—Inside diameter threads to inside diameter conduits
Conduit Connector Connector
Nominal Width
NW
Inside diameter
(nom.) ID
Thread Size
Inside diameter (nom.) IDO
Thread Size
Inside diameter (nom.) ID
Standard Inside Ø Nominal Metal Polyamide Metal Thread Polyamide Thread
NW07 6.2 PG07 8.0 M10
NW10 9.6 PG09 9.5 10.0 M12 5.7 8.0
M16 11.0
NW12 12.0 PG11 12.5 13.0 M16 9.7 11.0
PG13.5 14.5 14.5 ———
NW17 16.2 PG16 16.5 17.5 M20 13.7 14.6
NW23 22.6 PG21 22.5 22.5 M25 18.6 19.0
NW29 29.0 PG29 30.5 30.5 M32 25.7 26.0
NW36 36.5 PG36 40.5 37.5 M40 33.4 32.0
PG42 48.0 ———
NW48 47.5 PG48 52.0 50.0 M50 42.7 54.0
M63 54.0 53.0
American Standard Taper Pipe Thread
ID
ID
NW
NW
ID
ID
NW D
ID
90°
60° pitch
tapering 6.25%
Technical Information
www.tnb.ca
E100
Nylon Flexible Conduit Systems
PMA ®
Thread Metal*
[NM]
Polyamide
[NM]
M12 5 3
M16 6 4
M20 7 5
M25 10 8
M32 10 10
M40 15 15
M50 15 15
M63 15 15
Thread Metal*
[NM]
Polyamide
[NM]
PG07 4 2
PG09 5 3
PG11 6 4
PG13.5 7 5
PG16 7 5
PG21 10 10
PG29 15 15
PG36 15 15
PG48 15 15
Thread
Metal Lock Nut*
G-MXX
[NM]
Polyamide Lock Nut**
B/GMN-MXX
[NM]
M12 3 3
M16 6 4
M20 7 5
M25 8 8
M32 10 10
M40 15 15
M50 15 15
M63 15 15
* Thread combination: metal + metal.
** Thread combination: metal + polyamide or polyamide + polyamide.
Thread
Metal Lock Nut*
G-MXX
[NM]
Polyamide Lock Nut
B/GMN-MXX
[NM]
PG07 22.5
PG09 3 3
PG11 6 4
PG13.5 7 5
PG16 7 5
PG21 10 8
PG29 15 10
PG36 15 15
PG48 15 15
Note: Data represents approximate values. For application, please take into account the influence of
the counter-thread.
According to EN 50262 (manufacturers’ specifications)
Thread Metal Metal Polyamide
M12 5.0 6.0 0.7
M16 5.0 8.0 2.0
M20 7.5 10.0 3.0
M25 10.0 10.0 5.0
M32 15.0 15.0 7.5
M40 20.0 20.0 7.5
M50 20.0 20.0 7.5
M63 20.0 20.0 7.5
These values were gauged at standard climate (23° C/50% relative humidity).
According to DIN VDE 0619
Thread
Metal
NVNZ-PXXXX
[NM]
Metal
NVNZ-PXXXX/P
[NM]
Polyamide
S/BVNZ-PXXXX
[NM]
PG07 6.25 6.25 1.0
PG09 6.25 6.25 2.0
PG11 6.25 6.25 2.5
PG13.5 6.25 6.25 3.0
PG16 7.5 7.5 3.5
PG21 10.0 10.0 5.0
PG29 10.0 10.0 7.5
PG36 10.0 10.0 7.5
PG48 10.0 10.0 7.5
For threaded bore holes
With locknuts
Strain-Relief fittings
Technical Information
Recommended torques for PMA® fittings
www.tnb.ca E101
Nylon Flexible Conduit Systems
PMA ®
Fill factor, relevant guidelines
The question of conduit capacity or fill factor arises in the use
of cable protection systems. This describes the extent to which
a conduit can or should be filled with cables and/or conductors
based on the available cross-sectional area.
In all cases, PMA® recommends that a conduit capacity of 70% not
be exceeded. Application-specific procedures and standards must
also be considered.
This ensures that operation is not unnecessarily impaired
by increased friction between the individual conductors in
dynamically moving systems.
In addition, subsequent installation of additional conductors and/or
cables is also possible if necessary.
Wiring installation: Fixation
PMA recommends that cable protection systems be fastened with
a spacing of 300 to 500 mm between supports. This spacing can
be varied depending on the application and location.
This recommendation applies for all available dimensions.
For larger diameters, the increased load due to the cables and
conductors in the conduit is accounted for by adherence to the
support spacing. PMA supplies suitable system supports for
various strength requirements and applications.
European standard EN 50343:2003-5.15 “Railway applications
- Rolling stock - Rules for installation of cabling” specifies the
following spacing between supports for fastening conductors:
Horizontal wiring: 300 mm
Vertical wiring: 500 mm
Application-specific guidelines and standards should also be
considered.
fixation distances
Fill factor max. 70%
Technical Information
www.tnb.ca
E102
Nylon Flexible Conduit Systems
PMA ®
Resistance against Chemical Formula
PA6
Polyamide 6
PA66
Polyamide 66
PA12
Polyamide 12
PA11
Polyamide 11
PP
Polypropylene
PE
Polyethylene
TPU
Thermoplastic
Polyurethane
elastomer
PFA
Perfluoralkoxy
copolymer
PVDF
Polyvinylidene
fluoride
Acetic acid (10%) C2H4O2
•• ••• •••
Acetone C3H6O
• • • ••• ••• •••
Aonia (30%) NH3
• • • ••• ••• •••
Benzine
• • • ••• •• •••
Brake fluid
• • • ••• ••• •••
Caustic soda HNaO
• • • ••• ••• •••
Ethyl alcohol (40%) C2H6O
• • • ••• ••• •••
Glycol C2H6O2
• • • ••• ••• •••
Hydrochloric acid (10%) HCL
••• •••
Methanol CH4O
• • ••• ••• •••
Methyl ethyl ketone C4H8O
• • • ••• ••• •••
Nitric acid (10%) HNO3
•• •••
Ozone O3
• • •• •• •••
Paint thinner
• • • ••• •••
Perchlorethylene C2Cl4
•• •• •• •••
Paraffin
••• ••• •••
Phosphoric acid (10%) H3O4P
•• ••• •••
Sea water
••• ••• ••• •• •••
Soap solution
••• ••• ••• •• •••
Sodium chloride NaCI
••• ••• ••• ••• •••
Sulphuric acid (10%) H2SO4
•• ••• •••
Toluene C7H8
••• ••• •••
Trichlorethylene C2HCl3
•• •••
Turpentine
••• ••• •••
Urine
••• ••• ••• ••• •••
* Synthetic additives can affect the oil resistance of plastics.
Please contact your Thomas & Betts representative
for further information.
••• Excellent resistance/suitable for permanent contact
•• Resistant/suitable for occasional contact
• Relatively resistant/suitable for short-term contact
Not recommended
Important:
The chemical resistance of plastic products is also dependant on factors such as temperature, amount of time exposed to chemicals (e.g. occasional contact or iersed) as well as the
concentration of the specific chemicals.
The stated chemical resistances are valid for a temperature of -20° C. The chemical resistance table above serves only as a guide for the use of polyamide products in conjunction with the listed chemicals.
Each specic application should be controlled for suitability by the end-user.
Technical Information
Chemical Resistance
www.tnb.ca E103
Nylon Flexible Conduit Systems
PMA ®
Resistance against Chemical Formula
PA6
Polyamide 6
PA66
Polyamide 66
PA12
Polyamide 12
PA11
Polyamide 11
PP
Polypropylene
PE
Polyethylene
TPU
Thermoplastic
Polyurethane
elastomer
PFA
Perfluoralkoxy
copolymer
PVDF
Polyvinylidene
fluoride
Resistance against Oils and Greases
Cutting oils*
••• ••• •• •••
Diesel oil
••• ••• •• •• •••
ASTM oil No. 3
••• ••• •• •••
Fuel oil
••• ••• •• •••
Hydraulic oils*
••• ••• •• •••
Mineral oils
••• ••• •• ••• •••
Spark-erosion liquids
••• ••• •• •••
Skydrol
•• •• •••
Transformer oils*
••• ••• •• •••
* Synthetic additives can affect the oil resistance of plastics.
Please contact your Thomas & Betts representative
for further information.
••• Excellent resistance/suitable for permanent contact
•• Resistant/suitable for occasional contact
• Relatively resistant/suitable for short-term contact
Not recommended
Important:
The chemical resistance of plastic products is also dependant on factors such as temperature, amount of time exposed to chemicals (e.g. occasional contact or iersed) as well as the
concentration of the specific chemicals.
The stated chemical resistances are valid for a temperature of -20° C. The chemical resistance table above serves only as a guide for the use of polyamide products in conjunction with the listed chemicals.
Each specic application should be controlled for suitability by the end-user.
Technical Information
Chemical Resistance
www.tnb.ca
E104
Nylon Flexible Conduit Systems