3 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time from external to internal power. When utility power fails, your critical load remains supported by a seamless flow of power. Rack or tower configurable, the SolaHD S4KC UPS offers customers a higher power factor, longer battery life, higher reliability and reduced cost of ownership. Housed in a slim 2U package, the SolaHD S4KC protects equipment from virtually all power disturbances due to blackouts, brownouts, sags, surges or noise interference. The UPS includes internal batteries. Optional, matching external battery cabinets, also in a slim 2U (3.5") size, offer extended battery runtime. The LED display indicates battery capacity, percentage of UPS load, battery operation, bypass operation and UPS fault condition. The rack-tower models are also supplied with securing flanges and rack slide mounting hardware. Units can be easily hardwired by removing the attached line cord and receptacle plate. All units include a conduit knockout cover in the box. Features * Hardwire capability for permanent installation * Small 2U height maximizes available space * Input and output noise suppression * Higher Output Power Factor of 0.90 * PWM inverter reduces output voltage distortion * Add on batteries for extended back-ups * Integral sealed non-spillable batteries * Hot swappable user replaceable battery * Automatic restart * Automatic and manual battery test * Rack-mount or Stand-alone tower mounting *Units are field configurable with a PC as a frequency converter (bypass will be disabled) * Integral dynamic bypass reduces shutdowns * Compatible with most standby generators * Two-year limited warranty E179213 Applications * Industrial Automation Systems * Critical Microprocessors and PC Based Systems * Robotics and Process Control * Programmable Logic Controllers (PLC) * Mission Critical and High Speed Networks * Enterprise Telecommunication Systems * Pharmaceutical and Medical Diagnosis Equipment * Printing and Publishing Machinery Note: The securing flanges do not support the weight of the UPS. Rack slides or shelves are required (sold separately). 68 Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 3 Uninterruptible Power Systems Selection Table - S4K2U-C & S4K2U-5C Tower/Rack-Mount Models Capacity (VA/W) Catalog Number Typical Back-up Times (minutes)* Input Plug/Output Receptacle Approx. Ship Weight - lbs (kg) 700/630 S4K2U700-C 6/14 5-15P / (6) 5-15R 1000/900 S4K2U1000-C 5/15 5-15P / (6) 5-15R 1500/1350 S4K2U1500-C 5/16 5-15P / (6) 5-15R 57.3 (26) 2000/1800 S4K2U2000-C 4/11 5-20P / (6)5-20R (15/20 amp type) 61.7 (28) 3000/2700 S4K2U3000-C 4/14 L5-30P / (5)5-20R (15/20 amp type): (1) L5-30R 70.5 (32) 120 Vac, 50/60 Hz Models 52.9 (24) 230 Vac, 50/60 Hz International Models 1000/900 S4K2U1000-5C 5/15 IEC 320-C14 / (6) IEC 320/C13 44.0 (20) 2000/1800 S4K2U2000-5C 4/11 IEC 320-C20 / (6) IEC 320-C13 61.7 (28) 3000/2700 S4K2U3000-5C 4/14 IEC 320-C20 / (6) IEC 320-C13 (1) IEC 320-C19 70.5 (32) * Full/Half Load (in minutes). Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 69 3 Uninterruptible Power Systems S4K2U-C, 120 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number S4K2U700-C S4K2U1000-C S4K2U1500-C S4K2U2000-C S4K2U3000-C dimensions, d x w x h, in. [mm] Unit Shipping 19.7 x 16.9 x 3.4 [497 x 430 x 85] 23.7 x 16.9 x 3.4 [602 x 430 x 85] 25.5 x 23.9 x 10.6 [647 x 607 x 270] 29.4 x 23.4 x 10.6 [747 x 5607 x 270] weight, lb. [kg] Unit 37.0 [16.8] 51.1 [23.2] 51.1 [23.2] 71.4 [32.4] Shipping 44.1 [20.0] 57.3 [26.0] 57.3 [26.0] 79.4 [36.0] input ac Parameters 120 Vac nominal; variable based on output load Voltage Range (typical) 90% to 100% Loading 90 Vac/140 Vac 102 Vac/140 Vac 70% to 90% Loading 86 Vac/140 Vac 96 Vac/140 Vac 30% to 70% Loading 77 Vac/140 Vac 84 Vac/140 Vac 0% to 30% Loading 60 Vac/140 Vac 60 Vac/140 Vac 0.99 Power Factor 40 Hz to 70 Hz; auto sensing Frequency 10 ft. attached with NEMA 5-15P plug Input Power Cord 1 10 ft. attached with NEMA 5-20P plug 10 ft. attached with NEMA L5-30P plug 5-20R x 6 L5-30R x 1 + 5-20R x 6 output ac parameters Output Receptacles 5-15R x 6 1 110/115/120/127 Vac (user-configurable) 3% Voltage Sine wave Waveform Utility (Vac) Mode Overload 200% for 2 seconds; 150% for 50 seconds with transfer to bypass 0.90 Power Factor battery Valve-regulated, non-spillable, lead acid Type Qty x V x Rating 4 x 12 V x 5.0 Ah 4 x 12 V x 7.2 Ah Battery Mfr./Part Number YUASA/NPH5-12; CSB/HR 1221W Panasonic/UP-RW1236; CSB/GP 1272 Backup Time 2 Recharge Time 6/14 5/15 5/16 4 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/HR 1234W F2 4/11 0C to +40C [+32F to +104F]; See Operating Temperature Parameters -15C to +50C [+5F to +122F] Storage Temperature 0% to 95%, non-condensing Relative Humidity Operating Elevation Up to 10,000 ft. [3,000 m] at +40C [+104F] without derating 50,000 ft. [15,000 m] max. Storage Elevation Notes: 1. Full/half load (in minutes.) See selection table for more information. 2. Input power cord and receptacles can be removed for hardwired applications. 70 4/14 3 hours to 90% capacity after full discharge with 100% load until UPS auto shutdown (internal batteries only) Environmental Requirements Operating Temperature 6 x 12 V x 9.0 Ah Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 3 Uninterruptible Power Systems S4K2U-C, 120 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications cont. Catalog Number Audible Noise S4K2U700-C S4K2U1000-C S4K2U1500-C S4K2U2000-C <43 dBA max. @ 3 ft. [1 m] front & sides; <46 dBA max. @ 3 ft. [1 m] rear <45 dBA max. @ 3 ft. [1 m] front & sides; <50 dBA max. @ 3 ft. [1 m] rear <46 dBA max. @ 3 ft. [1 m] front & sides; <45 dBA max. @ 3 ft. [1 m] rear S4K2U3000-C <48 dBA max. @ 3 ft. [1 m] front & sides; <48 dBA max. @ 3 ft. [1 m] rear agency Safety UL1778, cUL Listed RFI/EMI FCC Part 15, Class A = CISPR22 Class B Surge Immunity IEC62040-2 2nd Ed. Transportation ISTA Procedure 1A Operating Temperature Parameters Ambient temperature Maximum output power factor derating at maximum load +25C to +30C [+77F to +86F] +30C to +35C [+86F to +95F] +35C to +40C [+95F to +104F] 100% to 93% 93% to 86% 86% to 79% Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 71 3 Uninterruptible Power Systems S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number S4K2U1000-5C S4K2U2000-5C S4K2U3000-5C dimensions, d x w x h, in. [mm] Unit Shipping 497 x 430 x 85 [19.6 x 16.9 x 3.3] 602 x 430 x 85 [23.7 x 16.9 x 3.3] 717 x 570 x 262 [28.2 x 22.4 x 10.3] 717 x 570 x 262 [28.2 x 22.4 x 10.3] weight, lb. [kg] Unit 37.0 [16.8] 51.1 [23.2] 71.4 [32.4] Shipping 44.1 [20.0] 57.3 [26.0] 79.4 [36.0] input ac Parameters 230 Vac nominal; variable based on output load Voltage Range (typical) 90% to 100% Loading 177 Vac/280 Vac 196 Vac/280 Vac 70% to 90% Loading 168 Vac/280 Vac 184 Vac/280 Vac 30% to 70% Loading 150 Vac/280 Vac 161 Vac/280 Vac 0% to 30% Loading 115 Vac/280 Vac 115 Vac/280 Vac 0.99 Power Factor 40 Hz to 70 Hz; auto sensing Frequency Input Power Receptacle 1 IEC 320 C14 IEC 320 C20 output ac parameters IEC 320 C13 x 6 Output Receptacles 1 IEC 320 C13 x 6; IEC 320 C19 x 1 220/230/240 Vac (user-configurable) 3% Voltage Frequency 50 Hz or 60 Hz Waveform Sine wave Overload 200% for 2 seconds; 150% for 50 seconds with transfer to bypass 200% for 2 seconds; 150% for 1 minute with transfer to bypass 200% for 2 seconds; 150% for 55 seconds with transfer to bypass 0.90 Power Factor battery Valve-regulated, non-spillable, lead acid Type Qty x V x Rating Battery Mfr./Part Number Backup Time 2 Recharge Time 4 x 12 V x 5.0 Ah 4 x 12 V x 9.0 Ah YUASA/NPH5-12; CSB/HR 1221W 6 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/HR 1234W F2 5/15 4/11 4/14 3 hours to 90% capacity after full discharge with 100% load until UPS auto shutdown (internal batteries only) Environmental Requirements Operating Temperature 0C to +40C [+32F to +104F]; See Operating Temperature Parameters Storage Temperatures -15C to +50C [+5F to +122F] 0% to 95%, non-condensing Relative Humidity Operating Elevation Up to 3,000 m [10,000 ft.] at +40C [+104F] without derating 15,000 m [50,000 ft.] max. Storage Elevation Notes: 1. Full/half load (in minutes.) See selection table for more information. 2. Input power cord and receptacles can be removed for hardwired applications. 72 Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 3 Uninterruptible Power Systems S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number Audible Noise S4K2U1000-5C S4K2U2000-5C <43 dBA max. @ 1 m [3 ft.] front & sides; <46 dBA max. @ 1 m [3 ft.] rear S4K2U3000-5C <48 dBA max. @ 1 m [3 ft.] front & sides; <48 dBA max. @ 1 m [3 ft.] rear agency Safety EC/EN/AS 62040-1-1:2008 RFI/EMI IEC/EN/AS 62040-2 2nd Ed. = CISPR22 Class A Surge Immunity IEC62040-2 2nd Ed. Transportation ISTA Procedure 1A Operating Temperature Parameters Ambient temperature Maximum output power factor derating at maximum load +25C to +30C [+77F to +86F] +30C to +35C [+86F to +95F] +35C to +40C [+95F to +104F] 100% to 93% 93% to 86% 86% to 79% Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 73 3 Uninterruptible Power Systems External Battery Cabinets Specifications Catalog Numbers Used with UPS models S4K2U48BATC S4K2U96BATC S4K2U700C, S4K2U1000C (-5), S4K2U1500C, S4K2U2000C (-5) S4K2U3000C (-5) dimensions, d x w x h, in. [mm] Unit Shipping 19.7 x 16.9 x 3.4 [497 x 430 x 85] 23.7 x 16.9 x 3.4 [602 x 430 x 85] 24.3 x 22.4 x 10.3 [617 x 570 x 262] 28.2 x 22.4 x 10.3 [717 x 570 x 262] weight, lbs. [kg] Unit 70.5 [32.0] 93.5 [42.4] Shipping 77.2 [35.0] 101.4 [46.0] battery Type Qty x V x Rating Battery Mfr./Part Number Valve-regulated, non-spillable, lead acid 2 x 4 x 12 V x 9.0 Ah 2 x 6 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/HR 1234W F2 Battery Back-up Times Chart Backup Time Environmental Requirements Operating Temperature 0C to +40C [+32F to +104F] Storage Temperatures -15C to +50C [+19F to +122F]; High ambient temperatures will reduce battery life 0% to 95%, non-condensing Relative Humidity Operating Elevation Up to 10,000 ft. [3,000 m] at +40C [+104F] without derating 50,000 ft. [15,000 m] max. Storage Elevation agency Safety UL1778, cUL Listed RFI/EMI FCC Part 15, Class A = CISPR22 Class B Surge Immunity IEC62040-2 2nd Ed. Transportation ISTA Procedure 1A 74 Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 3 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Battery Back-up Times1 Backup Time (minutes) at Load (watts)2 Number of Batteries Model VA1 200 W 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 1800 W 2000 W 2500 W Minutes Internal battery Internal battery + 1 external battery cabinet Internal battery + 2 external battery cabinets Internal battery + 3 external battery cabinets Internal battery + 4 external battery cabinet 100% Load Min. W 700 26 14 6 -- -- -- -- -- -- -- -- 6 630 1000 28 15 9 5 -- -- -- -- -- -- -- 4 900 1500 -- 26 16 10 8 5 -- -- -- -- -- 4 1350 2000 -- -- 20 11 10 8 6 5 4 -- -- 4 1800 3000 -- -- -- 25 20 14 10 9 8 5 4 4 2700 700 126 78 54 -- -- -- -- -- -- -- -- 50 630 1000 128 74 52 41 -- -- -- -- -- -- -- 27 900 1500 -- 110 72 48 36 28 -- -- -- -- -- 24 1350 2000 -- -- 54 34 34 26 22 17 15 -- -- 15 1800 3000 -- -- -- 102 80 56 50 44 38 26 22 18 2700 700 264 122 88 -- -- -- -- -- -- -- -- 82 630 1000 252 126 84 60 -- -- -- -- -- -- -- 58 900 1500 -- 208 132 94 74 54 -- -- -- -- -- 48 1350 2000 -- -- 120 82 60 52 44 36 29 -- -- 29 1800 3000 -- -- -- 124 114 106 92 74 66 62 46 44 2700 700 280 140 120 -- -- -- -- -- -- -- -- 116 630 1000 320 148 118 80 -- -- -- -- -- -- -- 78 900 1500 -- 310 204 138 102 90 -- -- -- -- -- 82 1350 2000 -- -- 180 126 92 72 62 52 45 -- -- 45 1800 3000 -- -- -- 174 150 122 110 105 104 76 62 62 2700 700 560 300 146 -- -- -- -- -- -- -- -- 140 630 1000 600 250 138 116 -- -- -- -- -- -- -- 109 900 1500 -- 400 256 180 144 110 -- -- -- -- -- 100 1350 2000 -- -- 240 166 130 108 94 84 64 -- -- 64 1800 3000 -- -- -- 184 172 150 128 120 119 105 92 84 2700 Backup times are valid for all models rated with the listed VA 2 Approximate backup times are in minutes and at +25C [+77F] with a resistive load 1 Note: S4K2U-5C models are not available in 700VA or 1500VA. Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 75