SWS300/600 Series Single Output General Purpose Power Supplies Low Cost Active Power Factor Correction Universal Input (85 - 265VAC) Input Transient Protected IEC61000-4 Enclosed Key Market Segments & Applications Factory Automation Test & Measurement Automated Service SWS Features and Benefits Feature Meets IEC61000-4 Global safety Approvals Power Factor Corrected Level B EMI Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Burn-in & Test, Automated, Detection Test, Instrumentation, Measurement Vending Machines, Elevators, Video Gaming, Point of Sale Equipment Benefit Greater reliability Supports Global Use Supports Global Use Assists System Compliance Specifications MODEL ITEMS Input Voltage range (1) Inrush Current (115 / 230VAC) A Power Factor Input Current (100/200VAC) A Temperature Coefficient Overcurrent Protection -Overvoltage Protection V Overtemperature Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Parallel Connection Remote On/Off AC Fail Signal LED Indicator Operating Temperature Storage Temperature Humidity (non-condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Immunity Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Weight (Typ) Size (WxHxD) Warranty Notes: ms mA C g in yrs SWS300 SWS600 85 - 265VAC (47 - 63Hz) or 120 - 370VDC 20 / 40 Meets EN61000-3-2 3.6 / 1.8A 7.2 / 3.6A <0.02%/C >105%, Constant current style 3.3V: 4.1-5.3V, 5V: 6.25-7.25V, 12V: 13.8-16.8V 15V: 18.7-22.5V, 24V: 30-34.8V, 36V: 41.4-50.4V, 48V: 60-69.6V Yes, cycle AC to reset 20ms at 115/230VAC SWS300: 0.75mA , SWS600: 1.5mA None Yes None Yes None Yes None Yes, open collector output Green LED = On -10 to +65C (See table for derating - model specific) -30 to +85C 30 - 90% RH operating, 10 - 95%RH non operating Internal fan I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to CNT 100VAC for 1 min >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (sweep for 1 min)19.6m/s2 constant X, Y, Z 1 hour each plane) EN61000-4-2, -3, -4, -5, -6, -8, -11 UL60950, CSA60950, EN60950, EN50178, CE Mark EN55011 / EN55022-B, FCC Class B To be advised 950 2000 2.05 x 4.01 x 7.8" 3.62 x 4.72 x 7.48" Two Years (1) Derate linearly to 85% load from 115VAC to 85VAC input (derate to 90% load for SWS600-3 & -5) 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 SWS300/600 Series Model Selector 150 0.5 21.5 +V +V 60 0.5 +V -V -V (95) -V 102 1 +V SEE NOTE B -V L N (8.5) 9.5 FG( ) AC(L) 24 8.2 -V Notes: (2) Peak rating of 120A for 10s (3) 115/230VAC SEE NOTE A -V 50/60Hz AC(N) (19.6) 198 1 9-M3.5 13MAX (12.1) 15 SEE NOTE B 52 1 30 0.5 TERMINAL COVER 6.5 67/70 75/78 77/80 79/83 80/84 82/85 82/85 69/71 74/77 78/81 80/83 81/84 81/85 82/85 INPUT: 100-240VAC ~ 4.4A 120 120 120 120 150 200 240 100 100 120 120 150 200 240 +V 20 20 48 48 48 72 96 20 20 48 48 48 72 96 55 A 40 40 96 120 120 180 240 40 40 96 120 120 180 240 +V 55 55 26 21 13 8.7A 6.7 100 (2) 100 (2) 50 40 25 16.7 12.5 LED OUTPUT: 5 V 2.97-3.96V 4.5-6V 9.6-13.2 13.2-18V 20-28.8 28.8-40V 40-57.6 2.97-3.96V 4.5-6V 9.6-13.2 13.2-18V 20-28.8 28.8-40V 40-57.6 VR FOR Vadj. (18.1) SWS300- 5 Eff.(3) (typ)% BAR CODE 3.3V 5V 12V 15V 24V 36V 48V 3.3V 5V 12V 15V 24V 36V 48V Ripple Noise (mV) HDK SWS300-3 SWS300-5 SWS300-12 SWS300-15 SWS300-24 SWS300-36 SWS300-48 SWS600-3 SWS600-5 SWS600-12 SWS600-15 SWS600-24 SWS600-36 SWS600-48 Adjust Range Line Reg (mV) MADE IN CHINA Voltage Load Reg (mV) V ADJ H Model SWS300 Outline Drawing Max Curr. (A) 155 0.5 16 SWS600 Outline Drawing (73) (10) Derating 8-M4 (16.5) 7-M3.5 L ) N ( AC -S PC TOG CNT PF SEE NOTE "C" (Tapped at the bottom chassis) 150 0.5 10 V.ADJ (20) 20 7.5 ON H 10 21 25 Additional derating required when operating SWS600 with side ventilation holes blocked - see installation manual. 34 +S 11 9.5 8.2 - SEE NOTE "C" (Tapped on both sides) - 50% 55% + 83.3% 70% + 91.6% 85% + 100% 100% 9.0 SWS300 SWS600 120 1 65C PLATE 60C PLATE NAME 55C 70 0.5 50C 100 0.5 Model (25) NAME (72) 190 1 92 1 Other Lambda Industrial Products 150 0.5 20 21MAX 21 15W & 30W Single Output, High Reliability 50-600W Single & Triple Output, High Reliability 50-150W Single Output 5-240W PCB style Single Output (20) 50 0.5 RWS JWS, JWS-P & JWT SWS ZWS Hole at the opposite chassis 5MAX (21) AIR FLOW For Additional Information, please visit www.lambdapower.com/products/sws-series.htm 15MAX SEE NOTE "C" (Tapped on both sides) 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 Revision A2: Dec 2004