Click on Series name for product info on aimtec.com Series AM2L-NZ 2 Watt | DC-DC Converter FEATURES: * * * * * * * Low Profile SMD 1000VDC & 6000VDC Isolation Industry Standard Pinout Unregulated Single & Dual Outputs MTBF>1,000,000 hours Operating temperature: -40C to +85C High Efficiency up to 85% Models Single output Model Input Voltage(V) Output Voltage (V) 4.5-5.5 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 5 5 15 5 15 Input Voltage (V) Output Voltage (V) AM2L-0505SH60-NZ AM2L-1205SH60-NZ AM2L-1215SH60-NZ AM2L-2405SH60-NZ AM2L-2415SH60-NZ Output Current max(mA) Isolation (VDC) Efficiency (%) 6000 6000 6000 6000 6000 77 78 81 79 80 Output Current max (mA) Isolation (VDC) Efficiency (%) 200 83 67 1000 1000 1000 82 84 85 400 400 133 400 133 Models Dual output Model AM2L-0505D-NZ AM2L-0512D-NZ AM2L-1215D-NZ 4.5-5.5 4.5-5.5 10.8-13.2 5 12 15 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 5 12 24 4.5-5.5 10.8-13.2 21.6-26.4 Conditions Typical Maximum Units VDC Isolation Specifications Parameters Tested I/O voltage Capacitance Resistance 60 sec 500VDC 500Vdc Rated Units 1000, 6000 VDC pF MOhm 10 >1000 Output Specifications Parameters Voltage accuracy Short Circuit protection Short Circuit Restart Line voltage regulation Load voltage regulation (5 Vout) Load voltage regulation (12 Vout) Load voltage regulation (15 Vout) Temperature coefficient Ripple & Noise* Minimum Load Current** Conditions See Tolerance Graph 1000VDC Momentary 6000VDC Continuous For a 1% change of Vin From 10% load to 100% load At 100% load 20MHz Bandwidth Typical Maximum Units 5 % 1 sec Auto-Recovery 1.2 12.8 6.8 6.3 0.03 150 10 % % %/oC mV p-p % of Max *Test ripple & noise by "Parallel Cable Method" as described in Application Note "Ripple and Noise Measurement of Brick & POL DC-DC Converters" available on Aimtec's website www.aimtec.com www.aimtec.com F 051e R12.S Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter **If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the load to ensure the actual load current meets the minimum load current requirement. General Specifications Parameters Conditions Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum Soldering Temperature Typical 100% load, nominal input -40 to + 85 -55 to + 125 Maximum Units 100 KHz oC oC oC 100 Free Air Convection 95 % RH Plastic(UL94-V0) 1000VDC 2.1 g 6000VDC 3.8 Single & Dual 1000VDC 0.70 x 0.70 x 0.24 inches 17.78 x 17.78 x 6.00 mm Single 6000VDC 0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm >1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25C) oC 1.5mm from case for 10 seconds 260 Safety Specifications Parameters Agency approvals CE (for 6000VDC isolation models) EN 60601-1-1; EN 60601-1-2 Standards Pin Out Specifications 1000VDC Pin 1 2 5 6 7 8 9 10 12 13 14 Single -Vin + Vin NC - Vout +Vout NC NC NC NC NC NC 6000VDC Dual - Vin + Vin -Vout Common +Vout NC NC -Vout NC NC NC NOTE: On dual output models Pin 5 and Pin 10 are connected internally together. Either Pin 5 or Pin 10, or both can be used as the -Vout NC: not connected www.aimtec.com F 051e R12.S Tel: +1 514 620 2722 2 of 4 Pin Single 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 - V in No Pin No Pin No Pin No Pin No Pin NC NC +V out -V out No Pin No Pin No Pin No Pin No Pin +V in Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Dimensions 1000VDC Side View 17.78 (0.70) Front View A 2.75 (0.11) 6.00 5.75 (0.24) (0.23) 0.25 (0.01) A 2.54 (0.10) 1.27 (0.05) Top View 0.25 (0.01) 17.78 (0.70) 2.54 (0.10) 1.00 2.00 (0.04) (0.08) 14 13 5.00 angle 12 10 9 8 1.30 0.13 (0.05 0.005) MAX 17.78 12.70 (0.70) (0.50) 1 2 3 5 6 7 Dimensions 6000VDC Side View 23.86 (0.94) Front View 8.00 7.50 (0.32) (0.30) A 3.04 (0.12) 13.10 (0.52) 2.54 (0.10) 2.00 (0.08) Top View 1.00 (0.04) 16 18.50 (0.73) A 10 9 0.50 (0.01) 18.50 13.70 (0.73) (0.54) 1 7 8 5.00 angle 1.35 0.13 (0.05 0.005) MAX 15.24 (0.60) www.aimtec.com F 051e R12.S Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Recommended Filter Circuit L Single Output L +Vout + Vin + Vin L Dual Output L +Vout + + Cin + DC DC Cin + Cout DC Common DC + L - Vin - Vin Cout Cout - Vin -Vout If it is required to decrease the input/output ripple an "LC" filter network can be installed on the input and output of the converter (see above). It should be noted that the inductance and the resonant frequency of the "LC" filtering network should differ from the DC/DC converter switching frequency to avoid mutual interference. The capacitance of the outputfilter capacitor must not exceed the values in the Table below to avoid startup problems and ensure safe and reliable operation. It's not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5 watt. External Capacitor Tables Input Capacitor (Cin) Vin (VDC) Cin (uF) 5 12 24 4.7 2.2 1 Output Capacitor (Cout) Single Vout (VDC) 5 15 Cout (uF) 10 1 Dual Vout (Vdc) Cout (uF) 5 12 15 4.7 1 0.47 Overload Protection The output circuit of these products has no protection against overload. It is recommended to install external overload protection in the form of a self-recovery fuse or a circuit breaker in series at the converter's input. To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the AM2LV-NZ series as an alternative. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.S Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only