Handy Calibrators Source and measure operations can be performed at the same time. (Select from the following source signal and measurement signal options: voltage, current, resistance, thermocouple (TC), resistance temperature detector (RTD), frequency, pulse). AC voltages, including supply voltage, can be measured. Includes a wide array of additional functions. Easy operation. Compact size and Lightweight Actual Size Bulletin CA71E H a n d y C a l i b r a t o r s Comprehensive source/measure instruments for all your calibration and equipment checking needs at maintenance sites Sensors and instruments require a wide variety of operation checks in the field. The CA71 Handy Calibrator is a small, lightweight, multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals. The CA51 Handy Calibrator is a basic model with the same functions as the CA71 except TC and RTD measurement functions and online communication functions. Simultaneous signal source and measurement capability The CA71 lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred. By itself it can source signals for input to equipment, and check output signal from equipment. With the CA71, you don't need to worry about synchronizing operations with other setting devices. (TC and RTD measurement functions are CA71 only.) A wide array of useful functions Source Values set in steps of 4-20 mA 24V DC Power Supply to Transmitter Divided output (n/m) function Output settings are divided, eliminating the need for bothersome calculations for percentage output. Autostep function Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%. Online communication (CA71 only) RS-232C-compliant optically isolated interface Sweep function Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds. Memory function Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets). Temperature monitor function AC voltage (including supply voltage) measurement capability Easy operation In cases where numerous signal converters and other devices are mounted on a rack or panel, the Handy Calibrator can be used to check the input and output signals of each device, while simultaneously checking the power supply. There is no need for a separate multimeter to measure supply voltage. The Handy Calibrator incorporates rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you're ready to take measurements. Panel layout Measurement input terminals 2. Terminal adapter 99021 (*2) 1. Measurement range setting rotary switch Select from the following: 4. Signal generation range setting rotary switch Select from the following: *2: Not used on CA51. 3. Output terminals for signal generation AC voltage DC voltage DC voltage TC TC (*1) Resistance Resistance RTD RTD Frequency pulse (*1) Frequency pulse DC current DC current *1: Only for CA71 5. POWER key 6. Various function settings Up/Down keys for generated signal setting Divided output (n/m) function Memory function 7. LIGHT key 8. TEMP key Turns on the LCD backlight. Enables temperature monitoring. Spare parts Product Model Source signal lead cable Measurement lead cable 98020 Carrying case RD031 Remarks One set, including one red cable and two black cables. Length: approximately 1.7 meters Terminal adapter 93016 One set, including one red cable and one black cable. Length: approximately 1.0 meter Fuse 99021 The carrying case can hold the source signal and measurement lead cables, terminal adapter, four spare batteries, fuses, AC adapter, and user's manual. 99040 Used in temperature measurement (for CA71). For current terminal input protection. (10pcs/set) Optional accessories (sold separately) AC adapter Product RJ sensor 94013 Model Accessory carrying case B9108WA Remarks 120 V AC power supply adapter Can hold lead cables, RJ sensor, etc. Handy Calibrator main unit Related product Product CA71 Handy Calibrator Product Pressure Calibrator Model CA71 CA51 Standard All of the following are included: accessories Source signal lead cables (one red, two black): 98020 Measurement lead cables (one red, one black): RD031 Carrying case: 93016 Terminal adapter for CA71: 99021 User's manual: IM CA71-E Fuse: 99040 (for current terminal input protection) Four AA alkaline batteries: A1070EB x4 Model Remarks CA700 91017 B9108XA For reference junction compensation CA51 Handy Calibrator Communication cable (RS232) Handy Calibrator CA150 Multi-functional Handheld Calibrator Source and measurement can be performed simultaneously. Loop power supply function Sink function D-sub 9-pin (female) Process Multimeter Process Clamp Meter CA450 CL420 and Specifications Signal sourcing unit range and accuracy (for both CA51 and CA71) (setting percentage plus V, mV, mA, or C) Parameter Reference DC voltage DC current Range -10.00-110.00 mV (0.02% + 15 V) 1V 0-1.1000 V (0.02% + 0.1 mV) 0.1 mV Maximum output: 5 mA 10 V 0-11.000 V (0.02% + 1 mV) 30 V 0-30.00 V (0.02% + 10 mV) 10 mV Maximum output: 10 mA *1 20 mA 0-24.000 mA 20 mA Resistance 400 (0.025% + 3 A) 1 mV 1 A DC voltage Maximum output: 10 mA Maximum load: 12 V DC current 4 mA (0.05% + 3 A) 0-400.00 (0.025% + 0.1 ) 0.01 Excitation current: 0.5-5 mA *3 If 0.1 mA, add 0.25 or 0.6C. Subject (0.025% + 0.3C) 0.1C device input capacitance: 0.1 F or less 1 A External power supply: 5-28 V Reference Accuracy (235C per year) Resolution 100 mV 0-110.00 mV (0.025% + 20 V) 1V 0-1.1000 V (0.025% + 0.2 mV) 0.1 mV 10 V 0-11.000 V (0.025% + 2 mV) 1 mV 100 V 0-110.00 V (0.05% + 20 mV) 0.01 V 20 mA 0-24.000 mA (0.025% + 4 A) 1 A 100 mA 0-100.00 mA (0.04% + 30 A) 10 A 0-400.00 (0.05% + 0.1 ) 0.01 Resistance 400 AC voltage Range 1V 0-1.100 V 10 V 0-11.00 V 100 V 0-110.0 V (0.5% + 5 dgt) -200.0-500.0C K -200.0-1372.0C (0.02% + 0.5C) 300 V 0-250 V* E -200.0-1000.0C (-100C or greater) 100 Hz 1.00-100.00 Hz J -200.0-1200.0C T -200.0-400.0C N -200.0-1300.0C (0C or greater) L -200.0-900.0C (0.02% + 1C) U -200.0-400.0C (0.02% + 1C) (0.02% + 0.5C) TC source accuracy does not include RJ sensor accuracy. RJ sensor specs Measurement range: -10-50C Accuracy (when combined with main unit) 18-28C: 0.5C Other than the above: 1C (0C or less) (100C or less) 0-1768C (0.02% + 1.5C) S (100C or greater) (0.02% + 2C) B 0.1C (0.02% + 2.5C) R 600-1800C 1000 Hz Frequency, 10 kHz pulse CPM 1.0-500.0 Hz 1000 Hz 90-1100 Hz Frequency, 10 kHz 0.9 kHz-11.0 kHz pulse Pulse 1-99,999 cycles cycle *5 0.1 kHz - TC *7 0.1 Hz Output voltage: +0.1-+15 V (zero base waveform) Amplitude accuracy: (5% + 0.1 V) 1 Hz Maximum load current: 10 mA Contact output 0.1 kHz (with 0.0 V amplitude setting, FET switch ON/OFF) 1 cycle Maximum open/close voltage/current: +28 V/50 mA Temperature coefficient: Accuracy shown above x (1/5)/C *1: Output up to 24 V/22 mA is possible when using the AC adapter. *2: As per JIS C 1604-1997 (ITS-90). IPTS-68 may be selected through internal settings (DIP switch). *3: Excitation current: If less than 0.1 mA to 0.5 mA, then add [0.025/ls (mA)] or [0.06/ls (mA)]C. *4: As per JIS C 1602-1995 (ITS-90) (L and U are DIN specs). K, E, J, T, N, R, S, and B may be switched to IPTS-68 through internal settings (DIP switch) (L and U are not switched). *5: Frequency (interval between one pulse and another) and amplitude during pulse cycle generation may have the same range as during frequency generation. 1V Input resistance: Approximately 14 Accuracy during 3-wire measurement Input resistance: Input frequency: Approximately 10 45-65 Hz Input voltage range: M/10 pF 10%-100% Input resistance: Measurement Approximately 1 method: Average M/10 pF value rectification 0.01 Hz Maximum input: 30 V peak Input resistance: 200 k or greater Sensitivity: 0.5 V peak or greater 0.001 kHz Contact input: Maximum 100 Hz Notes 1 CPM CPM: Counts per minute 1 CPH CPH: Counts per hour 1.0-1000.0 Hz 0.1 Hz 0.001-11.000 kHz 2 dgt 0-99,999 CPM 0-99,999 CPH Accuracy: (reading percentage + C) Parameter (0.02% + 1.5C) 1 Hz 0.1 V (0.5% + 2 dgt) Input resistance: Approximately 1 M Measurement unit (temperature; CA71 only) range and accuracy (1000C or less) 0.2 Hz 0.01 V Remarks Input resistance: 10 M or greater Temperature coefficient: Accuracy shown above x (1/5)/C * If safety standard EN 61010-1(EN61010-2-030) is not applicable, the Range is 0 to 300 V. 1C (1000C or greater) 500 Hz CPH 10 V 1 mV JPt100 (-100C or less) TC *4 Accuracy: (reading percentage plus V, mV, A, or dgt (digit)) Parameter 10 V 0.1-24.000 mA Pt100 *2 -200.0-850.0C RTD Remarks 100 mV 4-20 mA 4/8/12/16/20 mA mA SINK Accuracy (235C per year) Resolution Measurement unit range and accuracy (for both CA51 and CA71) RTD Range Reference Accuracy (235C per year) Resolution K -200.0-1372.0C E -200.0-1000.0C J -200.0-1200.0C T -200.0-400.0C N -200.0-1300.0C L -200.0-900.0C U -200.0-400.0C R 0-1768C S 0-1768C B 600-1800C Pt100 *6 -200.0-850.0C JPt100 -200.0-500.0C Remarks (0.05% + 1.5C) (-100C or greater) 0.1C (0.05% + 2C) (-100C or less) (0.05% + 2C) (100C or greater) (0.05% + 3C) (100C or less) 1C (0.05% + 0.6C) 0.1C Accuracy during 3-wire measurement Temperature coefficient: Accuracy shown above x (1/5)/C *6: As per JIS C 1604-1997 (ITS-90). IPTS-68 may be selected through internal settings (DIP switch). *7: As per JIS C 1602-1995 (ITS-90) (L and U are DIN specs). K, E, J, T, N, R, S, and B may be switched to IPTS-68 through internal settings (DIP switch) (L and U are not switched). General specifications (for both CA51 and CA71) Parameter Specification Signal generating unit response time Approximately 1 second (time between start of voltage change and when voltage enters accuracy range) Signal generating unit voltage limiter Approximately 32 V Signal generating unit current limiter Approximately 25 mA Parameter Specification Withstand voltage Across input terminal and output terminal, 3.7 kVAC, for one minute Operating temperature and humidity ranges 0-50C, 20-80% RH (no condensation) -20-50C, 90% RH or less (no condensation) Divided output (n/m) function Output = setting x (n/m) n = 0-m; m = 1-19; n m Storage temperature and humidity ranges Auto-step output function n value sent automatically when n/m function selection is selected (two options: approximately 2.5 seconds/step or approximately 5 seconds/step) External dimensions (WHD) Approximately 190 x 120 x 55 mm Sweep function Sweep time (two options: approximately 16 seconds or approximately 32 seconds) Weight Approximately 730 g (including batteries) Memory function 50 value sets (generated and measured values are stored as value sets with the same address (up to 50 value sets can be stored)) Measuring unit maximum input Voltage terminal: 300 V AC Current terminal: 120 mA DC Current terminal input protection Fuses: 125 mA/250 V Standard accessories Measuring unit ground voltage Maximum 300 V AC Measurement display updating rate Approximately once per second Serial interface Enabled when communication cable (RS232) is connected; sold separately as optional accessory (CA71 only) All of the following are included: Signal generating lead cables (one red, two black): 98020 Measurement lead cables (one red, one black): RD031 Carrying case: 93016 Terminal adapter for CA71: 99021 User's manual: IM CA71-E Fuse: 99040 (for current terminal input protection) Four AA alkaline batteries: A1070EB x 4 Display Segmented LCD (approximately 76 mm x 48 mm) Backlight LED backlight; auto-off after one minute (from when LIGHT key is turned on) Optional accessories Power supply Four AA alkaline batteries, or special AC adapter (sold separately) (sold separately) Battery life Measurement off, output 5 V DC/10 k or greater: Approximately 40 hours Simultaneous signal generation/measurement, output 5 V DC/10 k or greater: Approximately 20 hours Simultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours (using alkaline batteries, with backlight off) Consumed power Approximately 7 VA (using 100 V AC adapter) Auto-power-off function Approximately 10 minutes (auto-power-off can be disabled through a DIP switch setting) Conforming standards EN61010-1, EN61010-2-030 EN61010-031, EN61326-1, EN55011 Class B Group 1 EN61000-3-2, EN61000-3-3 Insulation resistance Across input terminal and output terminal, 500 V DC, 50 M or greater AC adapter: 94013 (120 V AC power supply) RJ sensor: B9108WA (For reference junction compensation) Accessory carrying case: B9108XA Communication cable: 91017 Signal generating lead cables (one red, two black): 98020 Measurement lead cables (one red, one black): RD031 Spare parts Carrying case: 93016 Terminal adapter: 99021 Fuse: 99040 (for current terminal input protection) NOTICE World Wide Web site at http://tmi.yokogawa.com YOKOGAWA METERS & INSTRUMENTS CORPORATION Tachihi Bld. No.2, 6-1-3 Sakaecho, Tachikawa-shi, Tokyo, 190-8586 Japan Phone: +81-42-534-1413 Facsimile: +81-42-534-1438 International Sales Dept. YOKOGAWA CORPORATION OF AMERICA (U.S.A.) YOKOGAWA EUROPE B. V. (THE NETHERLANDS) YOKOGAWA ENGINEERING ASIA PTE. LTD. (SINGAPORE) YOKOGAWA AMERICA DO SUL LTDA (BRAZIL) YOKOGAWA ELECTRIC KOREA CO., LTD. (KOREA) YOKOGAWA AUSTRALIA PTY. LTD. (AUSTRALIA) YOKOGAWA INDIA LTD. (INDIA) YOKOGAWA SHANGHAI TRADING CO., LTD. (CHINA) YOKOGAWA MIDDLE EAST B. S. C.(C) (BAHRAIN) YOKOGAWA ELECTRIC CIS LTD. (RUSSIAN FEDERATION) Phone: +1-770-253-7000 Phone: +31-88-4641000 Phone: +65-6241-9933 Phone: +55-11-5681-2400 Phone: +82-2-2628-3810 Phone: +61-2-8870-1100 Phone: +91-80-4158-6000 Phone: +86-21-6239-6363 Phone: +973-17-358100 Phone: +7-495-737-7868 Subject to change without notice. All Rights Reserved. Copyright (c) 2002, Yokogawa Meters & Instruments Corporation. Facsimile: +1-770-254-0928 Facsimile: +31-88-4641111 Facsimile: +65-6241-2606 Facsimile: +55-11-5681-4434 Facsimile: +82-2-2628-3899 Facsimile: +61-2-8870-1111 Facsimile: +91-80-2852-1441 Facsimile: +86-21-6880-4987 Facsimile: +973-17-336100 Facsimile: +7-495-737-7869 [Ed: 05/b] Before using the product, read the instruction manual carefully to ensure proper and safe operation. Represented by: MIK-ES18 Printed in Japan: Sep. 2013(C)/0,000(KP) Handy Calibrators Part Number Description CA71/SP1 CA71 Calibrator with standard accessories and 93037 Carrying case and 94009 Lithium ion battery Contact Information: www.Farnell.co.uk www.Newark.com