Linear Power Supplies Data Sheet Features * RoHS compatible for all six substances * Worldwide AC Input Capabilities: 100/120/220/230/240 VAC * 0.05% Output Regulation * Low Output Ripple * UL, CSA, and TUV Approvals * Mean Time Before Failure (MTBF) in Excess of 300,000 Hours * CE marked to Low Voltage Directive * 100% Burn-In * 2 Year Warranty * Overvoltage Protection (OVP) Standard on 5V Single Outputs, Optional for other outputs under 48V Description Power-One produces the industry's broadest selection of Linear power supplies with output voltages from 5 volts through 250 volts. Rugged technology and proven design merge to create quiet, highly-regulated, dependable DC power. The Linear power supplies are approved to domestic and international regulatory standards, and are CE Marked to the Low Voltage Directive (LVD). Overvoltage Protection Options OVERVOLTAGE PROTECTION OPTIONS These optional overvoltage protection modules are offered for use with Power-One's Linear power supplies. Each is user adjustable from 6.4V to 34V. OVP SELECTION GUIDE MODEL CASE SIZE OVP MODULES REQUIRED SINGLE OUTPUT B,C,N,D (1) OVP-12G E,F (1) OVP-24G DUAL OUTPUT AA,B,BB,CC (1) OVP-12G protects both outputs E (1) OVP-24G protects both outputs AA,BAA,D CBB, 131 DBB,DCC (1) OVP-12G protects both 12V through 15V outputs OVP-12G TRIPLE OUTPUT PEAK CURRENT MODELS NOTE: N,BAA,CBB 131 (1) OVP-12G protects any output not provided with built-in OVP Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48V through 250V models. OVP-24G MCD10016 Rev. 1.2, 13-Nov-09 Page 1 of 9 www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* Max Amps Model Input 100 to 264 VAC Case Type Additional Features & Notes 5Vout 5 1.5 HA5-1.5/OVP-AG B A 5 3 HB5-3/OVP-AG B A, C 5 6 HC5-6/OVP-AG C A, C 5 9 HN5-9/OVP-AG N A, C 5 12 HD5-12/OVP-AG D A, C 5 18 HE5-18/OVP-AG E A, C 5 25 F5-25/OVP-AG F A, C, D, H 5 35 G5-35/OVP-AG F A, C, D, H 5 50 CP197-AG F A, C, D 12 to 15Vout Case Type Dimensions (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 Dimensions (Millimeters) 12 12 0.9 1.7 HA15-0.9-AG HB12-1.7-AG B B C 12 3.4 HC12-3.4-AG C C 12 5.1 HN12-5.1-AG N C 12 6.8 HD12-6.8-AG D C 12 10.2 HE12-10.2-AG E C Case Type C, D, H AA 165.10 x 101.60 x 53.34 B 123.70 x 101.60 x 53.34 12 16 F15-15-AG F 15* 0.9 HA15-0.9-AG B 15 1.5 HB15-1.5-AG B C BAA 260.35 x 101.60 x 74.93 15 3 HC15-3-AG C C BB 177.80 x 123.70 x 74.93 15 4.5 HN15-4.5-AG N C C 142.75 x 123.70 x 74.93 15 6 HD15-6-AG D C CBB 279.40 x 123.70 x 83.31 15 9 HE15-9-AG E C CC 238.25 x 123.70 x 83.31 15* 15 F15-15-AG F C, D, H CP131 279.40 x 123.70 x 83.31 D 228.60 x 123.70 x 83.31 24 to 28Vout 24 24 0.5 1.2 HA24-0.5-AG HB24-1.2-AG B B DBB 361.95 x 123.70 x 85.85 C DCC 381.00 x 123.95 x 115.57 24 2.4 HC24-2.4-AG C C E 355.60 x 123.70 x 89.66 24 3.6 HN24-3.6-AG N C F 425.50 x 123.95 x 127.00 24 4.8 HD24-4.8-AG D C N 177.80 x 123.70 x 83.31 24 7.2 HE24-7.2-AG E C C, D, H 24 12 F24-12-AG F 28* 0.5 HA24-0.5-AG B 28 1 HB28-1-AG B C 28 2 HC28-2-AG C C 28 3 HN28-3-AG N C 28 4 HD28-4-AG D C 28 6 HE28-6-AG E C 28* 10 F24-12-AG F C, D, H 48 48 0.5 1 HB48-0.5-AG HC48-1-AG B C 48 3 HD48-3-AG D C 48 4 HE48-4-AG E C 48Vout (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10016 Rev. 1.2, 13-Nov-09 Page 2 of 9 www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* Max Amps Model Input 100 to 264 VAC Case Type Additional Features & Notes 5V to 15Vout +5, -5 1.5, 1.5 HAA5-1.5/OVP-AG AA A +5, -5 3, 3 HBB5-3/OVP-AG BB A +5, -5 6, 6 HCC5-6/OVP-AG CC A, C 5, 12 to 15 2, 0.5 HAA512-AG AA A 5, 12 to 15 3, 1.25 HBB512-AG BB A, C 5, 12 to 15 6, 2.5 HCC512-AG CC A, C +12, -5* 1, 0.4 HAA15-0.8-AG AA C +12, -5* 1.7, 0.7 HBB15-1.5-AG BB C +12, -12 0.4, 0.4 HAD12-0.4-AG B B +12, -12 1, 1 HAA15-0.8-AG AA C +12, -12 1.7, 1.7 HBB15-1.5-AG BB C +12, -12 3.4, 3.4 HCC15-3-AG CC C +12, -12* 5, 5 HDD15-5-AG E C +12, -15* 1, 0.8 HAA15-0.8-AG AA C +12, -15* 1.7, 1.5 HBB15-1.5-AG BB C +12, -15* 3.4, 3 HCC15-3-AG CC Case Type Dimensions (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 C Case Type Dimensions (Millimeters) +12, -15* 5, 5 HDD15-5-AG E C AA 165.10 x 101.60 x 53.34 +15, -5* 0.8, 0.4 HAA15-0.8-AG AA C B 123.70 x 101.60 x 53.34 +15, -5* 1.5, 0.7 HBB15-1.5-AG BB C BAA 260.35 x 101.60 x 74.93 177.80 x 123.70 x 74.93 142.75 x 123.70 x 74.93 +15, -12* 0.8, 1 HAA15-0.8-AG AA C BB +15, -12* 1.5, 1.7 HBB15-1.5-AG BB C C +15, -12* 3, 3.4 HCC15-3-AG CC C CBB 279.40 x 123.70 x 83.31 15, -12* 5, 5 HDD15-5-AG E C CC 238.25 x 123.70 x 83.31 15V to 24Vout CP131 279.40 x 123.70 x 83.31 +15, -15 0.4, 0.4 HAD15-0.4-AG B B D 228.60 x 123.70 x 83.31 +15, -15 0.8, 0.8 HAA15-0.8-AG AA C DBB 361.95 x 123.70 x 85.85 C DCC 381.00 x 123.95 x 115.57 355.60 x 123.70 x 89.66 +15, -15* 1.5, 1.5 HBB15-1.5-AG BB +15, -15* 3, 3 HCC15-3-AG CC C E +15, -15 5, 5 HDD15-5-AG E C F 425.50 x 123.95 x 127.00 N 177.80 x 123.70 x 83.31 +24, -24 0.6, 0.6 HAA24-0.6-AG AA +24, -24 1.2, 1.2 HBB24-1.2-AG BB +24, -24 2.4, 2.4 HCC24-2.4-AG CC * May require jumpering or potentiometer adjustment. MCD10016 Rev. 1.2, 13-Nov-09 Page 3 of 9 C (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* Max Amps Model Input 100 to 264 VAC Case Type Additional Features & Notes Triple Output Models, 5V to 24Vout +5, +12, -5* 2, 0.4, 0.4 HTAA-16W-AG AA A 5, +12, -5* 3, 1, 0.4 HBAA-40W-AG BAA A, C +5, +12, -5* 6, 1, 0.4 HCAA-60W-AG D A, C 5, +12, -5* 6, 1.7, 0.7 HCBB-75W-AG CBB C 5, +12, -5* 8, 1.7, 0.7 CP131-AG CP131 A, C 5, +12, -5* 12, 1.7, 0.7 HDBB-105W-AG DBB A, C 5, +12, -12 2, 0.4, 0.4 HTAA-16W-AG AA A 5, +12, -12 3, 1, 1 HBAA-40W-AG BAA A, C +5, +12, -12 6, 1, 1 HCAA-60W-AG D A, C 5, +12, -12 6, 1.7, 1.7 HCBB-75W-AG CBB C 5, +12, -12 8, 1.7, 1.7 CP131-AG CP131 A, C 5, +12, -12 12, 1.7, 1.7 HDBB-105W-AG DBB C Case Type Dimensions (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 Dimensions (Millimeters) 5, +12, -12 12, 3.4, 3.4 HDCC-150W-AG DCC A, C 5, +12, -15* 2, 0.4, 0.4 HTAA-16W-AG AA A 5, +12, -15* 3, 1, 0.8 HBAA-40W-AG BAA A, C +5, +12, -15* 6, 1, 1 HCAA-60W-AG D A, C Case Type 5, +12, -15 6, 1.7, 1.5 HCBB-75W-AG CBB C AA 165.10 x 101.60 x 53.34 5, +12, -15 8, 1.7, 1.5 CP131-AG CP131 A, C B 123.70 x 101.60 x 53.34 5, +12, -15* 12, 1.7, 1.5 HDBB-105W-AG DBB C BAA 260.35 x 101.60 x 74.93 5, +12, -15 12, 3.4, 3 HDCC-150W-AG DCC A, C BB 177.80 x 123.70 x 74.93 5, +15, -5* 2, 0.4, 0.4 HTAA-16W-AG AA A C 142.75 x 123.70 x 74.93 5, +15, -5* 3, 0.8, 0.4 HBAA-40W-AG BAA A, C CBB 279.40 x 123.70 x 83.31 +5, +15, -5* 6, 1, 0.4 HCAA-60W-AG D A, C CC 238.25 x 123.70 x 83.31 5, +15, -5* 6, 1.5, 0.7 HCBB-75W-AG CBB C CP131 279.40 x 123.70 x 83.31 5, +15, -5* 8, 1.5, 0.7 CP131-AG CP131 A, D 228.60 x 123.70 x 83.31 5, +15, -5* 12, 1.5, 0.7 HDBB-105W-AG DBB C DBB 361.95 x 123.70 x 85.85 5, +15, -12* 2, 0.4, 0.4 HTAA-16W-AG AA A DCC 381.00 x 123.95 x 115.57 5, +15, -12* 3, 0.8, 1 HBAA-40W-AG BAA A, C E 355.60 x 123.70 x 89.66 +5, +15, -12* 6, 1, 1 HCAA-60W-AG D A, C F 425.50 x 123.95 x 127.00 5, +15, -12 6, 1.5, 1.7 HCBB-75W-AG CBB C N 177.80 x 123.70 x 83.31 5, +15, -12 8, 1.5, 1.7 CP131-AG CP131 A, C 5, +15, -12* 12, 1.5, 1.7 HDBB-105W-AG DBB C 5, +15, -12 12, 3, 3.4 HDCC-150W-AG DCC A, C 5, +15, -15* 2, 0.4, 0.4 HTAA-16W-AG AA A 5, +15, -15* 3, 0.8, 0.8 HBAA-40W-AG BAA A, C +5, +15, -15* 6, 1, 1 HCAA-60W-AG D A, C 5, +15, -15 6, 1.5, 1.5 HCBB-75W-AG CBB C 5, +15, -15 8, 1.5, 1.5 CP131-AG CP131 A, C 5, +15, -15* 12, 1.5, 1.5 HDBB-105W-AG DBB C 5, +15, -15 12, 3, 3 HDCC-150W-AG DCC A, C * May require jumpering or potentiometer adjustment. MCD10016 Rev. 1.2, 13-Nov-09 Page 4 of 9 (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. www.power-one.com Linear Power Supplies Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION Input Voltage - AC (Note 1, 2) Jumper selectable, shipped factory configured for 120VAC operation. All models must be externally fused for proper operation. Fuse ratings are marked on each unit. Consult factory for each unit's fuse requirements. AC input. Output voltage charge for a 10% line change: F case models. HAD12, HAD15. Outputs with adjustable three terminal regulators. All other models. Input Frequency Line Regulation NOTES: 100 VAC Tap 120 VAC Tap 220 VAC Tap 240 VAC Tap MIN NOM MAX UNITS 87 104 191 209 100 120 220 240 110 132 242 264 VAC 47 -0.01 -1.0 -0.5 -0.05 63 +0.01 +1.0 +0.5 +0.05 Hz MAX UNITS % 1) Derate output current 10% for 50Hz operation. 2) Input voltage tolerance for 230VAC operation is +15%, -10%. Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM Output Adjustment Efficiency Minimum output adjustment range (Note 1). -5 +5 % 5 volt outputs. 45 12 volt and 15 volt outputs. 55 % 24 volt and higher outputs. 60 F case models. 3.0 mVPK-PK Ripple and Noise 5 volt, 12 volt, and 15 volt models. 5.0 mVPK-PK (Note 2) All three terminal regulator outputs. 0.2 %PK-PK 24 volt through 250 volt models. 3.0mVPK-PK plus 0.02% of output voltage, max Load Regulation Output change for a 50% load change: F case models. -0.02 +0.02 HAD12, HAD15. -1 +1 % Outputs with adjustable three terminal regulators. -0.5 +0.5 All other models. -0.05 +0.05 Transient Response Recovery time, to within 1% of initial set point due to a 50% load change. 50 s NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within 5% of factory setting of nominal output voltage. Locate the "Vadj" potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not adjustable. 2) Full load, 20MHz bandwidth. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL60950-1. CSA 60950-1 "cUL". EN60950-1. IEC60950-1. Input to output. Input to ground. FCC CFR title 47 Part 15 Sub-Part B - conducted. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. Per EN60950 Dielectric Withstand Voltage Electromagnetic Interference Leakage Current MIN NOM MAX UNITS Approved 3000 1500 VAC Compatible with system compliance to Level B. (264VAC) 23 50 A NOM MAX UNITS 6.6 V 250 mV 140 % Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN Overvoltage Protection Provided on 5 volt output units where indicated. Other outputs may use optional overvoltage protectors OVP-12 and OVP-24. Total voltage compensation for cable losses with respect to the main output. Provided on models where indicated. 5.8 Automatic current limit/foldback. Rated as a percentage of output power. 115 Remote Sense Overcurrent/Short Circuit Protection Master/Slave Operation 120 For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes. MCD10016 Rev. 1.2, 13-Nov-09 Page 5 of 9 www.power-one.com Linear Power Supplies Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Operating Temperature Derate output power linearly above 50C by 3% per C. Storage Temperature Temperature Coefficient Shock Vibration Relative Humidity MIN At 100% load At 40% load NOM 0 -40 0C to 50C (after 15 minute warm-up). 24 hours after warm-up. Operating. Random vibration from 10 Hz to 2 kHz, 3 axis. Non-Condensing. MCD10016 Rev. 1.2, 13-Nov-09 Page 6 of 9 0.1 -0.3 5 MAX UNITS 50 70 85 0.3 +0.3 20 6.15 95 C C C %/C % GPK GRMS %RH www.power-one.com Linear Power Supplies Data Sheet MCD10016 Rev. 1.2, 13-Nov-09 Page 7 of 9 www.power-one.com Linear Power Supplies Data Sheet MCD10016 Rev. 1.2, 13-Nov-09 Page 8 of 9 www.power-one.com Linear Power Supplies Data Sheet NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10016 Rev. 1.2, 13-Nov-09 Page 9 of 9 www.power-one.com