40 ns Propagation Delay, CMOS Optocoupler Technical Data HCPL-7710 HCPL-0710 Features Applications * +5 V CMOS Compatibility * 8 ns max. Pulse Width Distortion * 20 ns max. Prop. Delay Skew * High Speed: 12 MBd * 40 ns max. Prop. Delay * 10 kV/s Minimum Common Mode Rejection * -40 to 100C Temp. Range * Safety and Regulatory Approvals UL Recognized 2500 V rms for 1 min. per UL 1577 for HCPL-0710 3750 V rms for 1 min. per UL 1577 for HCPL-7710 CSA Component Acceptance Notice #5 VDE 0884 Approved (VDE) - VIORM = 630 Vpeak for HCPL-7710 Option 060 VDE 0884 (TUV) - VIORM = 560 Vpeak for HCPL-0710 Option 060 * Digital Fieldbus Isolation: DeviceNet, SDS, Profibus * AC Plasma Display Panel Level Shifting * Multiplexed Data Transmission * Computer Peripheral Interface * Microprocessor System Interface Functional Diagram **VDD1 1 8 VDD2** VI 2 7 NC* * 3 6 VO 5 GND2 IO LED1 GND1 4 SHIELD Description Available in either an 8-pin DIP or SO-8 package style respectively, the HCPL-7710 or HCPL-0710 optocouplers utilize the latest CMOS IC technology to achieve outstanding performance with very low power consumption. The HCPL-x710 require only two bypass capacitors for complete CMOS compatibility. Basic building blocks of the HCPL-x710 are a CMOS LED driver IC, a high speed LED and a TRUTH TABLE (POSITIVE LOGIC) VI, INPUT LED1 VO, OUTPUT H L OFF ON H L CMOS detector IC. A CMOS logic input signal controls the LED driver IC which supplies current to the LED. The detector IC incorporates an integrated photodiode, a high-speed transimpedance amplifier, and a voltage comparator with an output driver. *Pin 3 is the anode of the internal LED and must be left unconnected for guaranteed data sheet performance. Pin 7 is not connected internally. **A 0.1 F bypass capacitor must be connected between pins 1 and 4, and 5 and 8. CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. 2 Selection Guide 8-Pin DIP (300 Mil) HCPL-7710 Small Outline SO-8 HCPL-0710 Ordering Information Specify Part Number followed by Option Number (if desired) Example HCPL-7710#XXX 060 = VDE0884 Option. 300 = Gull Wing Surface Mount Option (HCPL-7710 only). 500 = Tape and Reel Packaging Option. No Option and Option 300 contain 50 units (HCPL-7710), 100 units (HCPL-0710) per tube. Option 500 contain 1000 units (HCPL-7710), 1500 units (HCPL-0710) per reel. Option data sheets available. Contact Agilent sales representative or authorized distributor. Package Outline Drawing HCPL-7710 8-Pin DIP Package 9.65 0.25 (0.380 0.010) TYPE NUMBER 8 7 6 7.62 0.25 (0.300 0.010) 5 OPTION 060 CODE* 6.35 0.25 (0.250 0.010) DATE CODE A XXXXV YYWW 1 1.19 (0.047) MAX. 2 3 4 1.78 (0.070) MAX. 5 TYP. 4.70 (0.185) MAX. + 0.076 0.254 - 0.051 + 0.003) (0.010 - 0.002) 0.51 (0.020) MIN. 2.92 (0.115) MIN. 1.080 0.320 (0.043 0.013) 0.65 (0.025) MAX. 2.54 0.25 (0.100 0.010) DIMENSIONS IN MILLIMETERS AND (INCHES). *OPTION 300 AND 500 NOT MARKED. 3 Package Outline Drawing HCPL-7710 Package with Gull Wing Surface Mount Option 300 PAD LOCATION (FOR REFERENCE ONLY) 9.65 0.25 (0.380 0.010) 8 1.016 (0.040) 1.194 (0.047) 6 7 5 4.826 TYP. (0.190) 6.350 0.25 (0.250 0.010) 1 3 2 9.398 (0.370) 9.906 (0.390) 4 1.194 (0.047) 1.778 (0.070) 9.65 0.25 (0.380 0.010) 1.780 (0.070) MAX. 1.19 (0.047) MAX. 0.381 (0.015) 0.635 (0.025) 7.62 0.25 (0.300 0.010) 4.19 MAX. (0.165) 1.080 0.320 (0.043 0.013) 0.635 0.25 (0.025 0.010) 0.635 0.130 2.54 (0.025 0.005) (0.100) BSC DIMENSIONS IN MILLIMETERS (INCHES). LEAD COPLANARITY = 0.10 mm (0.004 INCHES). + 0.076 0.254 - 0.051 + 0.003) (0.010 - 0.002) 12 NOM. Package Outline Drawing HCPL-0710 Outline Drawing (Small Outline SO-8 Package) 8 7 6 5 5.842 0.203 (0.236 0.008) 710V YWW 3.937 0.127 (0.155 0.005) OPTION 060 CODE* TYPE NUMBER (LAST 3 DIGITS) PIN 1 ONE 2 3 0.381 0.076 (0.016 0.003) DATE CODE 4 1.270 BSG (0.050) 7 5.080 0.005 (0.200 0.005) 3.175 0.127 (0.125 0.005) 45 X 0.432 (0.017) 0.228 0.025 (0.009 0.001) 1.524 (0.060) 0.152 0.051 (0.006 0.002) DIMENSIONS IN MILLIMETERS AND (INCHES). LEAD COPLANARITY = 0.10 mm (0.004 INCHES). *OPTION 500 NOT MARKED. 0.305 MIN. (0.012) 4 TEMPERATURE - C Solder Reflow Thermal Profile 260 240 220 200 180 160 T = 145C, 1C/SEC T = 115C, 0.3C/SEC 140 120 100 80 T = 100C, 1.5C/SEC 60 40 20 0 0 1 2 3 4 5 6 7 8 9 10 11 12 TIME - MINUTES (NOTE: USE OF NON-CHLORINE ACTIVATED FLUXES IS RECOMMENDED.) Regulatory Information CSA Approved under CSA Component Acceptance Notice #5, File CA 88324. The HCPL-x710 have been approved by the following organizations: UL Recognized under UL 1577, component recognition program, File E55361. TUV Rheinland (HCPL-0710 Option 060) Approved according to VDE 0884/06.92, Certificate R9650938. VDE (HCPL-7710 Option 060) Approved according to VDE 0884/06.92, File 6591.23-4880-1005. Insulation and Safety Related Specifications Parameter Minimum External Air Gap (Clearance) Minimum External Tracking (Creepage) Symbol L(I01) L(I02) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) Isolation Group CTI All Agilent data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as a starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit Value 7710 0710 7.1 4.9 Units mm 7.4 4.8 mm 0.08 0.08 mm 175 175 Volts IIIa IIIa Conditions Measured from input terminals to output terminals, shortest distance through air. Measured from input terminals to output terminals, shortest distance path along body. Insulation thickness between emitter and detector; also known as distance through insulation. DIN IEC 112/VDE 0303 Part 1 Material Group (DIN VDE 0110, 1/89, Table 1) board, minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest distance path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered. There are recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances. Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level. 5 VDE 0884 Insulation Related Characteristics (Option 060) Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage 150 V rms for rated mains voltage 300 V rms for rated mains voltage 450 V rms Climatic Classification Pollution Degree (DIN VDE 0110/1.89) Maximum Working Insulation Voltage Input to Output Test Voltage, Method b VIORM x 1.875 = VPR , 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC Input to Output Test Voltage, Method a VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage (Transient Overvoltage, tini = 10 sec) Safety Limiting Values (Maximum values allowed in the event of a failure, also see Thermal Derating curve, Figure 11.) Case Temperature Input Current Output Power Insulation Resistance at TS, V10 = 500 V Symbol HCPL-7710 Option 060 HCPL-0710 Option 060 I-IV I-III VIORM VPR I-IV I-IV I-III 55/100/21 2 630 1181 55/100/21 2 560 1050 V peak V peak VPR 945 840 V peak VIOTM 6000 4000 V peak TS IS,INPUT PS,OUTPUT RIO 175 230 600 109 150 150 600 109 C mA mW Units Refer to the front of the optocoupler section of the Isolation and Control Component Designer's Catalog, under Product Safety Regulations section (VDE 0884), for a detailed description. Note: These optocouplers are suitable for "safe electrical isolation" only within the safety limit data. Maintenance of the safety data shall be ensured by means of protective circuits. Note: The surface mount classification is Class A in accordance with CECC 00802. Absolute Maximum Ratings Parameter Storage Temperature Ambient Operating Temperature Supply Voltages Input Voltage Output Voltage Input Current Average Output Current Lead Solder Temperature Solder Reflow Temperature Profile Symbol Min. Max. Units Figure TS -55 125 C TA -40 +100 C VDD1, VDD2 0 5.5 Volts VI -0.5 VDD1 +0.5 Volts VO -0.5 VDD2 +0.5 Volts II -10 +10 mA IO 10 mA 260C for 10 sec., 1.6 mm below seating plane See Solder Reflow Temperature Profile Section Recommended Operating Conditions Parameter Ambient Operating Temperature Supply Voltages Logic High Input Voltage Logic Low Input Voltage Input Signal Rise and Fall Times Symbol TA VDD1, VDD2 VIH VIL t r, t f Min. -40 4.5 2.0 0.0 Max. +100 5.5 VDD1 0.8 1.0 Units C V V V ms Figure 1, 2 6 Electrical Specifications Test conditions that are not specified can be anywhere within the recommended operating range. All typical specifications are at TA = +25C, VDD1 = VDD2 = +5 V. Parameter DC Specifications Logic Low Input Supply Current Logic High Input Supply Current Input Supply Current Output Supply Current Input Current High Output Logic High Output Voltage Logic Low Output Output Voltage Voltage Symbol Min. Typ. Max. Units Test Conditions IDD1L 6.0 10.0 mA VI = 0 V IDD1H 1.5 3.0 mA VI = VDDI 5.5 13.0 11.0 10 mA mA A V IDD1 IDD2 II VOH -10 4.4 4.0 VOL Switching Specifications Propagation Delay Time tPHL to Logic Low Output Propagation Delay Time tPLH to Logic High Output Pulse Width PW Data Rate Pulse Width Distortion PWD |tPHL - tPLH| Propagation Delay Skew tPSK Output Rise Time tR (10 - 90%) Output Fall Time tF (90 - 10%) Common Mode |CMH| Transient Immunity at Logic High Output Common Mode |CM L| Transient Immunity at Logic Low Output Input Dynamic Power CPD1 Dissipation Capacitance Output Dynamic Power CPD2 Dissipation Capacitance 5.0 4.8 0 0.5 0.1 1.0 V 20 40 ns 23 40 3 12.5 8 Fig. Note 1 IO = -20 A, VI = VIH 1, 2 IO = -4 mA, VI = VIH IO = 20 A, VI = VIL IO = 4 mA, VI = VIL CL = 15 pF CMOS Signal Levels 3, 7 80 2 3 MBd ns 4, 8 20 5 9 CL = 15 pF CMOS Signal Levels 8 10 20 10 20 60 10 4 5, 9 6, 10 kV/s VI = VDD1, VO > 0.8 VDD1, VCM = 1000 V VI = 0 V, VO > 0.8 V, VCM = 1000 V pF 6 7 7 Package Characteristics Parameter Input-Output Momentary Withstand Voltage Symbol Min. Typ. Max. Units 0710 VISO 2500 Vrms 7710 Resistance (Input-Output) Capacitance (Input-Output) Input Capacitance Input IC Junction-to-Case -7710 Thermal Resistance -0710 Output IC Junction-to-Case -7710 Thermal Resistance -0710 Package Power Dissipation Notes: 1. The LED is ON when VI is low and OFF when VI is high. 2. tPHL propagation delay is measured from the 50% level on the falling edge of the VI signal to the 50% level of the falling edge of the VO signal. tPLH propagation delay is measured from the 50% level on the rising edge of the VI signal to the 50% level of the rising edge of the VO signal. 3. Mimimum Pulse Width is the shortest pulse width at which 10% maximum, Pulse Width Distortion can be guaranteed. Maximum Data Rate is the inverse of Minimum Pulse Width. Operating the HCPL-x710 at data rates above 12.5 MBd is possible provided PWD and data dependent jitter increases and relaxed noise margins are tolerable within the application. For instance, if the maximum allowable variation of bit width is 30%, the maximum data rate becomes 37.5 MBd. Please note that HCPL-x710 RI-O 1012 Test Conditions Fig. RH 50%, t = 1 min., TA = 25C VI-O = 500 Vdc CI-O 0.6 pF f = 1 MHz CI jci 3.0 145 160 140 135 3750 jco PPD Note 8, 9, 10 8 11 C/W 150 Thermocouple located at center underside of package mW performances above 12.5 MBd are not guaranteed by Hewlett-Packard. 4. PWD is defined as |t PHL - tPLH|. %PWD (percent pulse width distortion) is equal to the PWD divided by pulse width. 5. t PSK is equal to the magnitude of the worst case difference in t PHL and/or t PLH that will be seen between units at any given temperature within the recommended operating conditions. 6. CMH is the maximum common mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common mode voltage slew rate that can be sustained while maintaining VO < 0.8 V. The common mode voltage slew rates apply to both rising and falling common mode voltage edges. 7. Unloaded dynamic power dissipation is calculated as follows: C PD * VDD2 * f + I DD * VDD, where f is switching frequency in MHz. 8. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together. 9. In accordance with UL1577, each HCPL-0710 is proof tested by applying an insulation test voltage 3000 VRMS for 1 second (leakage detection current limit, II-O 5 A). Each HCPL7710 is proof tested by applying an insulation test voltage 4500 V rms for 1 second (leakage detection current limit, II-O 5 A). 10. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or HP Application Note 1074 entitled "Optocoupler Input-Output Endurance Voltage." 11. CI is the capacitance measured at pin 2 (VI). 2.2 0 C 25 C 85 C 3 2 27 1.9 1.8 1 0 29 0 C 25 C 85 C 2.0 VITH (V) 4 VO (V) 2.1 TPLH, TPHL (ns) 5 1.7 0 1 2 3 4 5 VI (V) Figure 1. Typical Output Voltage vs. Input Voltage. 1.6 4.5 25 TPLH 23 TPHL 21 19 17 4.75 5 5.25 5.5 VDD1 (V) Figure 2. Typical Input Voltage Switching Threshold vs. Input Supply Voltage. 15 0 10 20 30 40 50 60 70 80 TA (C) Figure 3. Typical Propagation Delays vs. Temperature. 8 4 7 11 6 3 2 TF (ns) TR (ns) PWD (ns) 10 5 4 9 1 0 3 20 0 40 60 8 80 20 0 40 TA (C) 60 80 21 19 5 25 17 15 21 TPLH TR (ns) 4 TPHL 23 PWD (ns) TPLH, TPHL (ns) 40 Figure 6. Typical Fall Time vs. Temperature. 6 27 3 2 19 13 11 9 7 5 17 1 15 15 0 15 3 20 25 30 35 40 45 50 20 25 CI (pF) 8 7 6 5 4 3 2 1 15 20 40 45 50 0 5 10 25 30 35 CI (pF) Figure 10. Typical Fall Time vs. Load Capacitance. 15 20 25 30 35 CI (pF) Figure 8. Typical Pulse Width Distortion vs. Output Load Capacitance. Figure 9. Typical Rise Time vs. Load Capacitance. OUTPUT POWER - PS, INPUT CURRENT - IS 9 10 35 OUTPUT POWER - PS, INPUT CURRENT - IS 10 5 30 1 CI (pF) Figure 7. Typical Propagation Delays vs. Output Load Capacitance. FALL TIME (ns) 20 0 TA (C) Figure 5. Typical Rise Time vs. Temperature. 29 0 2 80 TA (C) Figure 4. Typical Pulse Width Distortion vs. Temperature. 0 60 STANDARD 8 PIN DIP PRODUCT 800 PS (mW) IS (mA) 700 600 500 400 300 (230) 200 100 0 0 25 50 75 100 125 150 175 200 TA - CASE TEMPERATURE - C SURFACE MOUNT SO8 PRODUCT 800 PS (mW) IS (mA) 700 600 500 400 300 200 (150) 100 0 0 25 50 75 100 125 150 175 200 TA - CASE TEMPERATURE - C Figure 11. Thermal Derating Curve, Dependence of Safety Limiting Value with Case Temperature per VDE 0884. 9 Application Information technology allowing CMOS logic to be connected directly to the inputs and outputs. Bypassing and PC Board Layout The HCPL-x710 optocouplers are extremely easy to use. No external interface circuitry is required because the HCPL-x710 use high-speed CMOS IC VDD1 As shown in Figure 12, the only external components required for proper operation are two bypass capacitors. Capacitor values should be between 0.01 F and VDD2 8 1 0.1 F. For each capacitor, the total lead length between both ends of the capacitor and the power-supply pins should not exceed 20 mm. Figure 13 illustrates the recommended printed circuit board layout for the HPCL-x710. C1 C2 VI 710 YWW 2 NC 3 GND1 7 NC 6 VO 5 4 GND2 C1, C2 = 0.01 F TO 0.1 F Figure 12. Recommended Printed Circuit Board Layout. VDD1 VDD2 710 YWW VI C1 C2 VO GND1 GND2 C1, C2 = 0.01 F TO 0.1 F Figure 13. Recommended Printed Circuit Board Layout. Propagation Delay, PulseWidth Distortion and Propagation Delay Skew Propagation Delay is a figure of merit which describes how quickly a logic signal propagates through a system. The propaga- tion delay from low to high (tPLH) is the amount of time required for an input signal to propagate to the output, causing the output to change from low to high. Similarly, the propagation delay from high to low (tPHL) is the INPUT VI 50% 5 V CMOS 0V tPLH OUTPUT VO Figure 14. 90% 10% tPHL 90% 10% VOH 2.5 V CMOS VOL amount of time required for the input signal to propagate to the output, causing the output to change from high to low. See Figure 14. 10 Pulse-width distortion (PWD) is the difference between tPHL and tPLH and often determines the maximum data rate capability of a transmission system. PWD can be expressed in percent by dividing the PWD (in ns) by the minimum pulse width (in ns) being transmitted. Typically, PWD on the order of 20 - 30% of the minimum pulse width is tolerable. The PWD specification for the HCPL-x710 is 8 ns (10%) maximum across recommended operating conditions. 10% maximum is dictated by the most stringent of the three fieldbus standards, PROFIBUS. Propagation delay skew, tPSK, is an important parameter to consider in parallel data applications where synchronization of signals VI on parallel data lines is a concern. If the parallel data is being sent through a group of optocouplers, differences in propagation delays will cause the data to arrive at the outputs of the optocouplers at different times. If this difference in propagation delay is large enough it will determine the maximum rate at which parallel data can be sent through the optocouplers. Propagation delay skew is defined as the difference between the minimum and maximum propagation delays, either t PLH or tPHL, for any given group of optocouplers which are operating under the same conditions (i.e., the same drive current, supply voltage, output load, and operating temperature). As illustrated in Figure 15, if the inputs of a group of optocouplers are switched either ON or OFF at the same time, tPSK is the difference between the shortest propagation delay, either tPLH or tPHL, and the longest propagation delay, either tPLH or tPHL. As mentioned earlier, tPSK can determine the maximum parallel data transmission rate. Figure 16 is the timing diagram of a typical parallel data application with both the clock and data lines being sent through the optocouplers. The figure shows data and clock signals at the inputs and outputs of the optocouplers. In this case the data is assumed to be clocked off of the rising edge of the clock. 50% DATA VO INPUTS 2.5 V, CMOS CLOCK tPSK VI 50% DATA OUTPUTS VO 2.5 V, CMOS tPSK CLOCK tPSK Figure 15. Propagation Delay Skew Waveform. Propagation delay skew represents the uncertainty of where an edge might be after being sent through an optocoupler. Figure 16 shows that there will be uncertainty in both the data and clock lines. It is important that these two areas of uncertainty not overlap, otherwise the clock signal might arrive before all of the data outputs have settled, or Figure 16. Parallel Data Transmission Example. some of the data outputs may start to change before the clock signal has arrived. From these considerations, the absolute minimum pulse width that can be sent through optocouplers in a parallel application is twice tPSK. A cautious design should use a slightly longer pulse width to ensure that any additional uncertainty in the rest of the circuit does not cause a problem. The HCPL-x710 optocouplers offer the advantage of guaranteed specifications for propagation delays, pulse-width distortion, and propagation delay skew over the recommended temperature and power supply ranges. 11 Digital Field Bus Communication Networks To date, despite its many drawbacks, the 4 - 20 mA analog current loop has been the most widely accepted standard for implementing process control systems. In today's manufacturing environment, however, automated systems are expected to help CONTROLLER manage the process, not merely monitor it. With the advent of digital field bus communication networks such as DeviceNet, PROFIBUS, and Smart Distributed Systems (SDS), gone are the days of constrained information. Controllers can now receive multiple readings from field devices (sensors, actuators, etc.) in addition to diagnostic information. The physical model for each of these digital field bus communication networks is very similar as shown in Figure 17. Each includes one or more buses, an interface unit, optical isolation, transceiver, and sensing and/or actuating devices. BUS INTERFACE OPTICAL ISOLATION TRANSCEIVER FIELD BUS TRANSCEIVER TRANSCEIVER TRANSCEIVER TRANSCEIVER OPTICAL ISOLATION OPTICAL ISOLATION OPTICAL ISOLATION OPTICAL ISOLATION BUS INTERFACE BUS INTERFACE BUS INTERFACE BUS INTERFACE XXXXXX SENSOR YYY DEVICE CONFIGURATION MOTOR STARTER MOTOR CONTROLLER Figure 17. Typical Field Bus Communication Physical Model. Optical Isolation for Field Bus Networks To recognize the full benefits of these networks, each recommends providing galvanic isolation using Agilent optocouplers. Since network communication is bi-directional (involving receiving data from and transmitting data onto the network), two Agilent optocouplers are needed. By providing galvanic isolation, data integrity is retained via noise reduction and the elimination of false signals. In addition, the network receives maximum protection from power system faults and ground loops. Within an isolated node, such as the DeviceNet Node shown in Figure 18, some of the node's components are referenced to a ground other than V- of the network. These components could include such things as devices with serial ports, parallel ports, RS232 and RS485 type ports. As shown in Figure 18, power from the network is used only for the transceiver and input (network) side of the optocouplers. Isolation of nodes connected to any of the three types of digital field bus networks is best achieved by using the HCPL-x710 optocouplers. For each network, the HCPL-x710 satisify the critical propagation delay and pulse width distortion requirements over the temperature range of 0C to +85C, and power supply voltage range of 4.5 V to 5.5 V. 12 AC LINE NODE/APP SPECIFIC LOCAL NODE SUPPLY uP/CAN HCPL x710 GALVANIC ISOLATION BOUNDARY HCPL x710 5 V REG. TRANSCEIVER DRAIN/SHIELD V+ (SIGNAL) V- (SIGNAL) V+ (POWER) V- (POWER) SIGNAL POWER NETWORK POWER SUPPLY Figure 18. Typical DeviceNet Node. Implementing DeviceNet and SDS with the HCPL-x710 With transmission rates up to 1 Mbit/s, both DeviceNet and SDS are based upon the same broadcast-oriented, communications protocol -- the Controller Area Network (CAN). Three types of isolated nodes are recommended for use on these networks: Isolated Node Powered by the Network (Figure 19), Isolated Node with Transceiver Powered by the Network (Figure 20), and Isolated Node Providing Power to the Network (Figure 21). Isolated Node Powered by the Network This type of node is very flexible and as can be seen in Figure 19, is regarded as "isolated" because not all of its components have the same ground reference. Yet, all components are still powered by the network. This node contains two regulators: one is isolated and powers the CAN controller, nodespecific application and isolated (node) side of the two optocouplers while the other is nonisolated. The non-isolated regulator supplies the transceiver and the non-isolated (network) half of the two optocouplers. NODE/APP SPECIFIC uP/CAN HCPL x710 ISOLATED SWITCHING POWER SUPPLY HCPL x710 GALVANIC ISOLATION BOUNDARY REG. TRANSCEIVER DRAIN/SHIELD V+ (SIGNAL) V- (SIGNAL) V+ (POWER) V- (POWER) SIGNAL POWER NETWORK POWER SUPPLY Figure 19. Isolated Node Powered by the Network. 13 Isolated Node with Transceiver Powered by the Network Figure 20 shows a node powered by both the network and another source. In this case, the transceiver and isolated (network) side of the two optocouplers are powered by the network. The rest of the node is powered by the AC line which is very beneficial when an application requires a significant amount of power. This method is also desirable as it does not heavily load the network. More importantly, the unique "dual-inverting" design of the HCPL-x710 ensure the network will not "lock-up" if either AC line power to the node is lost or the node powered-off. Specifically, when input power (VDD1) to the HCPL-x710 located in the transmit path is eliminated, a RECESSIVE bus state is ensured as the HCPL-x710 output voltage (VO ) go HIGH. *Bus V+ Sensing It is suggested that the Bus V+ sense block shown in Figure 20 be implemented. A locally powered node with an unpowered isolated Physical Layer will accumulate errors and become bus-off if it attempts to transmit. The Bus V+ sense AC LINE NODE/APP SPECIFIC NON ISO 5V uP/CAN HCPL x710 HCPL x710 *HCPL x710 GALVANIC ISOLATION BOUNDARY REG. TRANSCEIVER DRAIN/SHIELD V+ (SIGNAL) V- (SIGNAL) V+ (POWER) V- (POWER) SIGNAL POWER NETWORK POWER SUPPLY * OPTIONAL FOR BUS V + SENSE Figure 20. Isolated Node with Transceiver Powered by the Network. signal would be used to change the BOI attribute of the DeviceNet Object to the "auto-reset" (01) value. Refer to Volume 1, Section 5.5.3. This would cause the node to continually reset until bus power was detected. Once power was detected, the BOI attribute would be returned to the "hold in bus-off" (00) value. The BOI attribute should not be left in the "auto-reset" (01) value since this defeats the jabber protection capability of the CAN error confinement. Any inexpensive low frequency optical isolator can be used to implement this feature. 14 Isolated Node Providing Power to the Network Figure 21 shows a node providing power to the network. The AC line powers a regulator which provides five (5) volts locally. The AC line also powers a 24 volt isolated supply, which powers the network, and another five-volt regulator, which, in turn, powers the transceiver and isolated (network) side of the two optocouplers. This method is recommended when there are a limited number of devices on the network that don't require much power, thus eliminating the need for separate power supplies. More importantly, the unique "dual-inverting" design of the HCPL-x710 ensure the network will not "lock-up" if either AC line power to the node is lost or the node powered-off. Specifically, when input power (VDD1) to the HCPL-x710 located in the transmit path is eliminated, a RECESSIVE bus state is ensured as the HCPL-x710 output voltage (VO) go HIGH. AC LINE DEVICENET NODE NODE/APP SPECIFIC 5 V REG. uP/CAN HCPL x710 ISOLATED SWITCHING POWER SUPPLY HCPL x710 GALVANIC ISOLATION BOUNDARY 5 V REG. TRANSCEIVER DRAIN/SHIELD SIGNAL POWER Figure 21. Isolated Node Providing Power to the Network. V+ (SIGNAL) V- (SIGNAL) V+ (POWER) V- (POWER) 15 Power Supplies and Bypassing The recommended DeviceNet application circuit is shown in Figure 22. Since the HCPL-x710 are fully compatible with CMOS logic level signals, the optocoupler is connected directly to the CAN transceiver. Two bypass capacitors (with values between 0.01 and 0.1 F) are required and should be located as close as possible to the input and output power-supply pins of the HCPLx710. For each capacitor, the GALVANIC ISOLATION BOUNDARY ISO 5 V 5V 1 VDD1 TX0 2 VIN 0.01 F 3 LINEAR OR SWITCHING REGULATOR VDD2 8 + 0.01 F 7 HCPL-x710 TxD VO 6 4 GND1 VCC 5 V+ GND2 5 + C4 0.01 F 3 SHIELD REF GND 1 V- VREF RXD 0.01 F 3 2 CAN- CANL GND1 4 6 VO 4 CAN+ 82C250 Rs 5 GND2 + CANH GND RX0 total lead length between both ends of the capacitor and the power supply pins should not exceed 20 mm. The bypass capacitors are required because of the high-speed digital nature of the signals inside the optocoupler. D1 30 V HCPL-x710 0.01 F 7 8 VDD2 ISO 5 V VIN 2 VDD1 1 5V Figure 22. Recommended DeviceNet Application Circuit. Implementing PROFIBUS with the HCPL-x710 An acronym for Process Fieldbus, PROFIBUS is essentially a twisted-pair serial link very similar to RS-485 capable of achieving high-speed communication up to 12 MBd. As shown in Figure 23, a PROFIBUS Controller (PBC) establishes the connection of a field automation unit (control or central processing station) or a field device to the transmission medium. The PBC consists of the line transceiver, optical isolation, frame character transmitter/receiver (UART), and the FDL/APP processor with the interface to the PROFIBUS user. PROFIBUS USER: CONTROL STATION (CENTRAL PROCESSING) OR FIELD DEVICE USER INTERFACE FDL/APP PROCESSOR UART PBC OPTICAL ISOLATION TRANSCEIVER MEDIUM Figure 23. PROFIBUS Controller (PBC). C1 0.01 F 500 V R1 1M Power Supplies and Bypassing The recommended PROFIBUS application circuit is shown in Figure 24. Since the HCPL-x710 are fully compatible with CMOS logic level signals, the optocoupler is connected directly to the transceiver. Two bypass capacitors (with values between 0.01 and 0.1 F) are required and should be located as close as possible to the input and output power-supply pins of the HCPL-x710. For each capacitor, the total lead length between both ends of the capacitor and the power supply pins should not exceed 20 mm. The bypass capacitors are required because of the high-speed digital nature of the signals inside the optocoupler. Being very similar to multi-station RS485 systems, the HCPL-061N optocoupler provides a transmit disable function which is necessary to make the bus free after each master/slave transmission cycle. Specifically, the HCPL-061N disables the transmitter of the line driver by putting it into a high state mode. In addition, the HCPL-061N switches the RX/TX driver IC into the listen mode. The HCPL-061N offers HCMOS compatibility and the high CMR performance (1 kV/s at VCM = 1000 V) essential in industrial communication interfaces. GALVANIC ISOLATION BOUNDARY 5V ISO 5 V 8 VDD2 VDD1 1 VIN 2 7 0.01 F ISO 5 V HCPL-x710 6 VO Rx 3 5 GND2 1 0.01 F GND1 4 3 ISO 5 V 1 VDD1 2 VIN Tx D 0.01 F 7 + RT B 7 SHIELD - DE 2 RE VDD2 8 A 6 SN75176B 4 5V R 0.01 F 8 VCC GND 5 0.01 F 1M HCPL-x710 VO 6 3 0.01 F 4 GND1 GND2 5 ISO 5 V VCC 8 1 5V Tx ENABLE 1, 0 k 680 VE 7 2 ANODE 0.01 F VO 6 3 CATHODE 4 GND 5 HCPL-061N www.semiconductor.agilent.com Data subject to change. Figure 24. Recommended PROFIBUS Application Circuit. Copyright (c) 1999 Agilent Technologies Obsoletes 5968-2818E 5968-7458E (11/99)