RE22R2KMR Product data sheet Characteristics Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Off-delay Timing Relay - 0.05s...10min - 24... 240V AC/DC - 2C/O Main Range of product Zelio Time Product or component type Modular timing relay Discrete output type Relay Device short name RE22 Nominal output current 5A Complementary Contacts type and composition 2 C/O timed contact, cadmium free Time delay type K Time delay range 3...30 s 30...300 s 0.3...3 s 1...10 s 10...100 s 1...10 min 0.05...1 s Control type Rotary knob External potentiometer [Us] rated supply voltage 24...240 V AC/DC at 50/60 Hz Release input voltage <= 2.4 V Voltage range 0.85...1.1 Us Supply frequency 50...60 Hz (+/- 5 %) Connections - terminals Screw terminals : 1 x 0.5...1 x 3.3 mm, AWG 20...AWG 12 solid cable without cable end Screw terminals : 2 x 0.5...2 x 2.5 mm, AWG 20...AWG 14 solid cable without cable end Screw terminals : 1 x 0.2...1 x 2.5 mm, AWG 24...AWG 14 flexible cable with cable end Screw terminals : 2 x 0.2...2 x 1.5 mm, AWG 24...AWG 16 flexible cable with cable end Tightening torque 0.6...1 N.m conforming to IEC 60947-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift +/- 0.05 %/C Jul 18, 2019 1 Voltage drift +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 C conforming to IEC 61812-1 Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Recovery time 100 ms (on de-energisation) Immunity to microbreaks <= 10 ms Power consumption in VA 3 VA at 240 V AC Power consumption in W 2 W at 240 V DC Switching capacity in VA 1250 VA Minimum switching current 10 mA 5 V DC Maximum switching current 5A Maximum switching voltage 250 V AC Electrical durability 100000 cycles for 2 A at 24 V DC-1 100000 cycles for 5 A at 250 V AC-1 Mechanical durability 10000000 cycles Rated impulse withstand voltage 5 kV for 1.2...50 s conforming to IEC 60664-1 Power on delay < 200 ms Creepage distance 4 kV/3 conforming to IEC 60664-1 Overvoltage category III conforming to IEC 60664-1 Safety reliability data B10d = 160000 MTTFd = 171.2 years Mounting position Any position Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Status LED Green LED backlight (steady) for dial pointer indication Yellow LED (steady) for output relay energised Yellow LED (steady) for power ON Width 22.5 mm Product weight 0.1 kg Environment Dielectric strength 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 Standards IEC 61812-1 UL 508 Directives 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive Product certifications GL EAC RCM China RoHS CCC CE CSA UL Ambient air temperature for operation -20...60 C Ambient air temperature for storage -40...70 C IP degree of protection IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Vibration resistance 20 m/s (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn (not operating) (duration = 11 ms) conforming to IEC 60068-2-27 5 gn (in operation) (duration = 11 ms) conforming to IEC 60068-2-27 Relative humidity 95 % at 25...55 C Electromagnetic compatibility Fast transients immunity test (test level: 1 kV, level 3 - capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test (test level: 1 kV, level 3 - differential mode) conforming to IEC 61000-4-5 Surge immunity test (test level: 2 kV, level 3 - common mode) conforming to IEC 61000-4-5 Electrostatic discharge (test level: 6 kV, level 3 - contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge (test level: 8 kV, level 3 - air discharge) conforming to IEC 61000-4-2 2 Radiated radio-frequency electromagnetic field immunity test (test level: 10 V/m, level 3 - 80 MHz...1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances (test level: 10 V, level 3 - 0.15...80 MHz) conforming to IEC 61000-4-6 Fast transient bursts (test level: 2 kV, level 3 - direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops (test level: 30 % - 500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops (test level: 100 % - 20 ms) conforming to IEC 61000-4-11 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1650 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product Environmental Profile Product end of life instructions Available End of Life Information 3 Product data sheet Dimensions Drawings Dimensions 4 RE22R2KMR Product data sheet Connections and Schema RE22R2KMR Wiring Diagram 5 Product data sheet Technical Description RE22R2KMR Function K: Delay On De-energization without Auxillary Supply Description On energisation of power supply, the output(s) R close(s).On de-energisation of power supply, timing period T starts and at the end of this period, the output(s) R revert(s) to its/their initial state.The energization of power supply > Tk is necessary to sustain the timing period T. Function: 1 Output Tk > 1s Function: 2 Outputs Tk > 80ms Legend Relay de-energised Relay energised Output open Output closed USupply TTiming period R1/R2 -2 timed outputs 6