(R) 51-54 Series II Thermometer Product Overview Presentation du produit Descrizione generale del prodotto Produktubersicht Caracteristicas de los productos Informacoes gerais sobre o produto Productoverzicht Produktoversikt Oversigt over termometerserien Yleiskatsaus Produktoversikt PN 1276114 September 1999 Rev. 2, 3/11 (c) 1999-2011 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. 11/99 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 51-54 Series II Introduction The Fluke Models 51, 52, 53, and 54 Thermometers ("the thermometer") are microprocessor-based, digital thermometers. This guide provides an overview of the thermometers. Detailed Users Manuals are available on the accompanying CD-ROM. Each thermometer comes with a 3-year warranty, which is described in the Users Manual. Model 51 52 53 54 Inputs Single Dual Single Dual Thermocouple Types J, K, T, E J, K, T, E J, K, T, E, R, S, N J, K, T, E, R, S, N The Models 53 and 54 have logging and PC interface capabilities. 1 51-54 Series II Product Overview Contacting Fluke To order accessories, a printout of the Users Manual, receive assistance, or locate the nearest Fluke distributor or Service Center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Address correspondence to: Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven USA The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-warranty.com Replacement Parts and Accessories Accessory Holster and Flex Stand Assembly AA NEDA 15A IEC LR6 batteries 80PK-1 K-Type Bead Thermocouple CD-ROM Service Manual 2 Part Number 1272438 376756 773135 1276106 1276123 51-54 Series II Safety Information Safety Information Warning A Warning identifies conditions and actions that pose hazards to the user. To avoid electrical shock or personal injury, follow these guidelines: * Before using the thermometer inspect the case. Do not use the thermometer if it appears damaged. Look for cracks or missing plastic. Pay particular attention to the insulation around the connectors. * Disconnect the thermocouple(s) from the thermometer before opening the case. * Replace the batteries as soon as the battery indicator () appears. The possibility of false readings can lead to personal injury. * Do not use the thermometer if it operates abnormally. Protection may be impaired. When in doubt, have the thermometer serviced. * Do not operate the thermometer around explosive gas, vapor, or dust. * Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. * Do not connect to voltages >30 V ac rms, 42 V pk, 60 V dc from earth ground. 3 51-54 Series II Product Overview Warning (cont.) * * * Models 52 and 54: Measurement errors may occur if voltages on the measurement surfaces result in potentials greater than 1 V between the two thermocouples. When potential differences are anticipated between the thermocouples, use electrically insulated thermocouples. When servicing the thermometer, use only specified replacement parts. Do not use the thermometer with any part of the case or cover removed. Caution To avoid damaging the thermometer or the equipment under test. 4 * Use the proper thermocouples, function, and range for your thermometer. * Do not attempt to recharge the batteries. * Do not throw batteries into a fire to prevent explosion. * Follow local laws or regulations when disposing batteries. * Match the + and - polarities of the battery with the battery case. 51-54 Series II Components Components 3 5 4 2 1 6 7 aat10f.eps Thermocouple T1 input Buttons Models 52 and 54: Thermocouple T2 input Battery door Holster Batteries Display 5 51-54 Series II Product Overview Display Elements 2 3 4 5 6 7 1 8 9 12 10 11 aat11f.eps Measurement includes an offset. Displayed readings are frozen. Low battery. Primary Display. Shift function is in progress. Readings are being logged.* Setup is in progress. Logged readings are displayed.* * Models 53 and 54 6 Temperature units. Secondary Display. Thermocouple type. Time Display. 51-54 Series II Buttons Buttons (Shift function) Turn the thermometer on or off. , = stop displaying the minimum, maximum, and average readings. , = delete logged readings from memory. , = toggle the IR port on and off. Turn the backlight on and off. Step through the maximum, minimum, and average readings. Switch between Celsius (oC), Fahrenheit (oF), and Kelvin (K). Freeze or unfreeze the displayed readings. Toggle showing the T1, T2, and T1-T2. (Models 52 and 54) Start or exit Setup. Scroll to a Setup option or increase the displayed setting. Scroll to a Setup option or decrease the displayed setting. Enter a Setup option or store the displayed setting. Start or stop logging.* Show toggle showing logged and MIN MAX readings.* * Models 53 and 54 7 51-54 Series II Product Overview Changing Setup Options Press to start or exit Setup. Press or to scroll to the setup option you want to change. 3. Press to indicate that you want to change this setting. 4. Press or until the setting you want to use appears on the display. 5. Press to store the new setting in memory. Setup Options 1. 2. Option Settings Logging Interval* INTERVAL 0, 1, 2, 3, 4, or Thermocouple TYPE JKTERSN Offset T1 or T2 Sleep Mode or Time* --:-- 0 to 24 for hours 0 to 60 for minutes Line Frequency Noise Rejection 60 H (60 Hz North America) 50 H (50 Hz other countries) * Models 53 and 54 8 Menu Item 51-54 Series II Specifications Specifications General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm x 7.8 cm x 16.2 cm (1.1 in x 3 in x 6.4 in) Battery 3 AA batteries Certification , Safety CAN/CSA C22.2 No. 61010-1-04, ANSI/UL 610101:2004, EN/IEC 61010-1:2001 EMC EN/IEC 61326-1:2006 CAT I OVERVOLTAGE (Installation) CATEGORY I, Pollution Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. Category 1 products should not be attached to mains circuits. Environmental Operating Temperature -10 oC to 50 oC (14 oF to 122 oF) Storage Temperature -40 oC to +60 oC (-40 oF to +140 oF) Humidity Non condensing <10 oC (<50 oF) 95% RH: 10 oC to 30 oC (50 oF to 86 oF) 75% RH: 30 oC to 40 oC (86 oF to 104 oF) 45% RH: 40 oC to 50 oC (104 oF to 122 oF) 9 51-54 Series II Product Overview Electrical Measurement Range J-type: -210 oC to +1200 oC (-346 oF to + 2192 oF) K-type: -200 oC to +1372 oC (-328 oF to +2501 oF) T-type: -250 oC to +400 oC (-418 oF to +752 oF) E-type: -150 oC to +1000 oC (-238 oF to +1832 oF) N-type: -200 oC to +1300 oC (-328 oF to +2372 oF) R- and S-type: 0 oC to +1767 oC (+32 oF to +3212 oF) Display Resolution 0.1 oC / oF / K < 1000o 1.0 oC / oF / K 1000o Measurement Accuracy J-, K-, T-, E-, and N-type: [0.05 % of reading + 0.3 o C (0.5 oF)] [Below -100 oC (-148 oF): add 0.15 % of reading for J, K, E, and N; and 0.45 % of reading for T] R- and S-type: Temperature Coefficient [0.05 % of reading + 0.4 oC (0.7 oF)] 0.01 % of reading + 0.03 oC per oC (0.05 oF per oF) outside the specified +18 oC to 28 oC (+64 oF to +82 o F) range [Below -100 oC (-148 oF): add 0.04 % of reading for J-, K-, E-, and N-type; and 0.08 % of reading for Ttype] Susceptibility: 2 oC (3.6 oF) for 80 MHz to 200 MHz in Electromagnetic 1.5 V/m field, for 200 MHz to 1000 MHz in 3 V/m field. Compatibility Emmisions: Commercial Limits per EN50081-1 Maximum Differential Common Mode Voltage 1 V (Maximum voltage difference between T1 and T2) Temperature Scale ITS-90 Applicable NIST-175 Standards Accuracy is specified for ambient temperatures between 18 oC (64 oF) and 28 oC (82 oF) for a period of 1 year. The above specifications do not include thermocouple error. 10 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLUKE-53-2 B 60HZ