Instruction Sheet AMP NETCONNECT 408-8875 Assembly Instructions for ETHERSEAL* Receptacle Kits In-Line Coupler 27 NOV 07 Rev B Receptacle O-Ring Nut Shield (With Shielded Kits Only) Toolless Jack AMP-TWIST 6S Jack SL Series Jack Bend-Limiting Strain Relief PART NUMBER RECEPTACLE KIT DESCRIPTION 1479561-2 UTP, Cat 5e, Toolless Jack 1479562-2 Shielded, Cat 5e, Toolless Jack 1479563-2 UTP, Cat 5e, SL Series Jack 1479564-2 Shielded, Cat 5e, SL Series Jack 1479565-2 UTP, Cat 6, SL Series Jack 1479566-2 Shielded, Cat 6 SL Series Jack 1479567-2 Receptacle Only, No Jack 1479599-2 UTP, Cat 5e, In-Line Coupler 1479600-2 Shielded, Cat 5e, In-Line Coupler 1933589-2 AMP-TWIST 6S Jack Figure 1 1. INTRODUCTION NOTE Dimensions are in millimeters [with inches in brackets]. Figures are not drawn to scale. This instruction sheet provides assembly procedures for the receptacle kits listed in Figure 1. To obtain information on AMP NETCONNECT products, call PRODUCT INFORMATION at the number at the bottom of this page, or visit the AMP NETCONNECT website at www.ampnetconnect.com. E 2007 Tyco Electronics Corporation, Harrisburg, PA All International Rights Reserved i 2. DESCRIPTION Each receptacle kit includes a receptacle, an O-ring, a nut, and either a Toolless Jack Assembly, an SL Series Jack Assembly, an In-Line Coupler, or an TOOLING ASSISTANCE CENTER 1-800-722-1111 This controlled document is subject to change. PRODUCT INFORMATION 1-800-522-6752 For latest revision and Regional Customer Service, TE logo and Tyco Electronics are trademarks. *Trademark. Other products, logos, and company names used are the property of their respective owners. visit our website at www.tycoelectronics.com 1 of 2 LOC B 408-8875 Assembly Procedures for ETHERSEAL Receptacle Kits AMP-TWIST 6S Jack. The shielded kits also include a shield. receptacle. Hook the fixed latch into the slot inside the receptacle. The jacks accept four-pair, twisted-pair cable with 22 to 24 AWG solid conductors and 24 AWG stranded conductors. The maximum conductor insulation diameter is 1.14 [.045] (Toolless jack) and 1.27 [.050] (SL Series jack). 6. Rotate the back of the jack (or coupler) down. The movable latch will deflect and lock into the receptacle. White Arrow Indicator 3. TERMINATION PROCEDURES Receptacle Refer to the instruction sheet listed in Figure 2 for wire preparation and termination of each jack assembly. JACK ASSEMBLY DESCRIPTION INSTRUCTION SHEET Unshielded Toolless Jack 408-4542 Shielded Toolless Jack 408-4588 Unshielded SL Series Jack 408-8417 Shielded SL Series Jack 408-8602 AMP-TWIST 6S Jack 411-93007 Nut O-Ring Figure 2 Faceplate 4. RECEPTACLE AND JACK INSTALLATION Figure 4 The receptacle can be installed in a panel or a faceplate cutout. Faceplates can be purchased separately. Refer to Figure 3 for recommended panel cutout dimensions. White Arrow Indicator (Ref - Front of Receptacle) 25.65 [1.010] Fixed 28.45 [1.120] Latch Figure 3 Refer to Figure 4 and proceed as follows: 1. Slide O-ring over threaded portion of receptacle. 2. Insert threaded portion of receptacle through front of panel/faceplate cutout. Orient receptacle in cutout so that white arrow indicator on front of receptacle is facing up. Insert Jack (or Coupler) at a Slight Angle and Rotate Un til Movable Latch Snaps Into Place 3. Attach nut (with 20-in-lb torque) to threaded portion of receptacle at back of panel/faceplate. 4. Insert jack (or coupler) into back of receptacle by aligning the fixed tab on the jack with the white arrow indicator on the front of the receptacle. See Figure 5. 5. Tilt the back of the jack (or coupler) up at a slight angle and slide it into the opening in the 2 of 2 Movable Latch Figure 5 5. REVISION SUMMARY Added AMP-TWIST 6S Jack and Cat 6 SL Series Jack. Tyco Electronics Corporation Rev B