1
Fuseholders FPG3
www.schurter.com/PG02
Fuses
Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap/Fingergrip, Snap stepless, 1.0 - 3.0 mm, IEC 60335-1
Fingergrip
250 VAC · 2.5 W / 10 A (VDE) · 400 V · 16 A (UL/CSA)
Description
- Meets the new requirements of IEC 60335-1 for appliances in unatten-
ded use (clause 30.2.3). This includes the enhanced requirements of
glow wire tests acc. to IEC 60695-2-12 and -13. Order numbers: xxxx.
xxxx.15
- Panel Thickness 1.0 - 3.0 mm, Snap stepless
- Fuseholder available in black, grey and white
Standards
- IEC 60127-6
- UL 4248-1
- CSA 22.2 no. 4248-1
Approvals
- VDE Certificate Number: 127216
- UL File Number: E39328
Applications
- Industrial electronic
- Household appliances
- Medical equipment
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Shock-Safe Category PC2
Fuse-Link 5 x 20 mm
Mounting Panel Mount, Front Side
Mounting Snap-in
Terminal Solder or Quick-Connect 4.8 x 0.5 mm
Rated Voltage 250 VAC , 400 V (UL/CSA)
Rated current 6.3/10 A (VDE), 16 A (UL/CSA)
Rated Power Acceptance IEC 2.5 W / 10 A @ Ta 23 °C
2.5 W / 10 A for xxxx.xxxx.15 versions
in horizontal position
Degree of Protection IP 40
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category 40/085/21 acc. to IEC 60068-1
Material: Socket Thermoplastic, black, UL 94V-0
Material: Terminals Tin-Plated Copper Alloy
Unit Weight 5.3 g
Storage Conditions 0 °C to 60 °C, max. 70% r.h.
Product Marking , Type, Rated voltage, Power Acc./
Current Rating, Panel Thickness, Ap-
provals
Soldering Methods Iron
Soldering Profile
Solderability 350 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 2
Resistance to Soldering Heat 350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
Contact Resistance < 5 mΩ at 20 mV
Dielectric Strength > 3 kV
> 4 kV between L/N-PE
(50 Hz; 1 min)
Impulse Withstand Voltage > 2.5 kV between L-N
> 6 kV between L/N-PE
Insulation Resistance > 10 MΩ between L-N
> 100 MΩ between L/N-PE
(500 VDC; 1 min)
Overvoltage Category I - III acc. to IEC 60664-1
Pollution Degree 1 - 3 acc. to IEC 60664-1
Resistance to Vibration acc. to IEC 60068-2-6, test Fc
Panel Thickness s 1.0 - 3.0 mm