MINI-BEAM Universal Voltage Series
page 6Banner Engineering Corp. • Minneapolis, U.S.A.
Website: http://www.baneng.com • Tel: 888.373.6767
MINI-BEAM Universal Voltage Series Specifications
Supply Voltage and Current Universal voltage: 24 to 240V ac, 50/60Hz or
24 to 240V dc (1.5 watts or 2.5 VA maximum)
Supply Protection Circuitry Protected against transient voltages. DC hookup is without regard to polarity.
Output Configuration SPDT (Single-Pole, Double Throw) (form C) electromechanical relay, ON/OFF output.
Output Rating Maximum switching power (resistive load): 90W, 250VA
Maximum switching voltage (resistive load): 250V ac or 30V dc
Maximum switching current (resistive load): 3A
Minimum voltage and current: 5V dc, 10 mA
Mechanical life: 20,000,000 operations
Electrical life at full resistive load: 100,000 operations
Output Protection Circuitry Protected against false pulse on power-up.
Output Response Time Closure time: 20 milliseconds max.
Release time: 20 milliseconds max.
Maximum switching speed: 25 operations per second
Repeatability All sensing modes: 1 millisecond
Adjustments Light/Dark Operate select switch, and 15-turn slotted brass screw Gain (sensitivity) adjustment
potentiometer (clutched at both ends of travel). Both controls are located on rear panel of sensor and are
protected by a gasketed, clear acrylic cover.
Indicators Exclusive, patented Alignment Indicator Device system (AID™, US patent #4356393) lights a rear-panel-
mounted LED indicator whenever the sensor sees a “light” condition, with a superimposed pulse rate
proportional to the light signal strength (the stronger the signal, the faster the pulse rate).
Construction Reinforced thermoplastic polyesterhousing, totally encapsulated, o-ring seal, acrylic lenses, and stainless
steel screws.
Environmental Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13; IEC IP67.
Connections PVC-jacketed 5-conductor (2-conductor for emitters) 2 m (6.5') or 9 m (30') unterminated cable.
Operating Conditions Temperature: -20° to +55°C (-4° to +131°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Application Notes Install transient suppressor (MOV) across contacts switching inductive loads.