PI6C3991 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer SuperClock(R) Features Description * All output pair skew <100ps typical (250 Max.) PI6C3991 offers selectable control over system clock functions. These multiple-output clock drivers provide the system integrator with functions necessary to optimize the timing of high-performance computer systems. Eight individual drivers, arranged as four pairs of user-controllable outputs, can each drive terminated transmission lines with impedances as low as 50 ohms while delivering minimal and specified output skews and full-swing logic levels (LVTTL). * 3.75 MHz to 80 MHz output operation * User-selectable output functions -- Selectable skew to 18ns -- Inverted and Non-Inverted -- Operation at 1/2 and 1/4 input frequency -- Operation at 2X and 4X input frequency (input as low as 3.75 MHz, x4 operation) Each output can be hardwired to one of nine skews or function configurations. Delay increments of 0.7ns to 1.5ns are determined by the operating frequency with outputs able to skew up to 6 time units from their nominal "zero" skew position. The completely integrated PLL allows external load and transmission line delay effects to be canceled. The user can create output-to-output skew up to 12 time units. * Zero input-to-output delay * 50% duty-cycle outputs * LVTTL outputs drive 50-ohm terminated lines * Operates from a single 3.3V supply * Low operating current Divide-by-two and divide-by-four output functions are provided for additional flexibility in designing complex clock systems. When combined with the internal PLL, these divide functions allow distribution of a low-frequency clock that can be multiplied by two or four at the clock destination. This feature allows flexibility and simplifies system timing distribution design for complex high-speed systems. * Available in 32-pin PLCC (J) package * Jitter < 200ps peak-to-peak (< 25ps RMS) Pin Configuration Logic Block Diagram VCO and Time Unit Generator 4 FS 4Q0 4F0 4F1 Select Inputs (three level) 3F0 3F1 2F0 2F1 1F0 1F1 4Q1 Skew 3Q0 Select 3Q1 2Q0 Matrix 3 2 1 32 31 5 29 6 28 7 27 2F0 GND 1F1 VCCQ VCCN 4Q1 4Q0 GND 8 26 1F0 25 GND 13 32-Pin J 11 23 12 22 VCCN 1Q0 1Q1 GND 21 GND 9 10 24 14 15 16 17 18 19 2Q1 1Q0 1Q1 1 30 3F1 4F0 4F1 20 2Q1 2Q0 Filter VCCN FB VCCN REF Phase Freq. DET 3Q1 3Q0 FB 3F0 FS VCCQ REF GND TEST 2F1 Test PS8450D 03/06/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Pin Descriptions Signal Name I/O De s cription REF I Reference frequency input. This input supplies the frequency and timing against which all functional variation is measured. FB I PLL feedback input (typically connected to one of the eight outputs) FS I Three- level frequency range select. see Table 1. 1F0, 1F1 I Three- level function select inputs for output pair 1 (1Q0, 1Q1). See Table 2. 2F 0, 2F 1 I Three- level function select inputs for output pair 2 (2Q0, 2Q1). See Table 2. 3F 0, 3F 1 I Three- level function select inputs for output pair 3 (3Q0, 3Q1). See Table 2. 4F 0, 4F 1 I Three- level function select inputs for output pair 4 (4Q0, 4Q1). See Table 2. TEST I Three- level select. See test mode section under the block diagram descriptions 1Q0, 1Q1 O Output pair 1. See Table 2 2Q 0, 2Q 1 O Output pair 2. See Table 2 3Q 0, 3Q 1 O Output pair 3. See Table 2 4Q 0, 4Q 1 O Output pair 4. See Table 2 VCCN PWR Power supply for output drivers VCCQ PWR Power supply for internal circuitry GND PWR Ground Table 1. Frequency Range Select and tU Calculation(1) Table 2. Programmable Skew Configurations(1) FS (1,2) FNOM (M Hz) tU = 1 fNOM x N Approximate Fre q. (M Hz) at which tU= 1.0ns M in. M a x. whe re N= LOW 15 30 44 22.7 MID 25 50 26 38.5 HIGH 40 80 16 62.5 Function Se le cts 1F1, 2F1, 3F1, 4F1 1F0, 2F0, 3F0, 4F0 Output Functions 1Q0, 1Q1, 2Q0, 2Q1 3Q0, 3Q1 4Q0, 4Q1 LOW LOW -4tU Divide by 2 Divide by 2 LOW MID -3tU -6tU -6tU LOW HIGH -2tU -4tU -4tU MID LOW -1tU -2tU -2tU MID MID 0tU 0tU 0tU MID HIGH +1tU +2tU +2tU HIGH LOW +2tU +4tU +4tU HIGH MID +3tU +6tU +6tU HIGH HIGH +4tU Divide by 4 Inverted Notes: 1. For all three-state inputs, HIGH indicates a connection to VCC, LOW indicates a connection to GND, and MID indicates an open connection. Internal termination circuitry holds an unconnected input to VCC/2. 2. The level to be set on FS is determined by the "normal" operating frequency (fNOM) and Time Unit Generator (see Logic Block Diagram). Nominal frequency (fNOM) always appears at 1Q0 and the other outputs when they are operated in their undivided modes (see Table 2). The frequency appearing at the REF and FB inputs will be f NOM when the output connected to FB is undivided. The frequency of the REF and FB inputs will be fNOM/2 or fNOM/4 when the part is configured for a frequency multiplication by using a divided output as the FB input. 2 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Block Diagram Description Test Mode Phase Frequency Detector and Filter The TEST input is a three-level input. In normal system operation, this pin is connected to ground, allowing the PI6C3991 to operate as explained briefly above (for testing purposes, any of the three level inputs can have a removable jumper to ground, or be tied LOW through a 100 Ohm resistor. This will allow an external tester to change the state of these pins.) If the TEST input is forced to its MID or HIGH state, the device will operate with its internal phase locked loop disconnected, and input levels supplied to REF will directly control all outputs. Relative output to output functions are the same as in normal mode. In contrast with normal operation (TEST tied LOW). All outputs will function based only on the connection of their own function select inputs (xF0 and xF1) and the waveform characteristics of the REF input. These two blocks accept input signals from the reference frequency (REF) input and the feedback (FB) input and generate correction information to control the frequency of the Voltage-Controlled Oscillator (VCO). These blocks, along with the VCO, form a PhaseLocked Loop (PLL) that tracks the incoming REF signal. VCO and Time Unit Generator The VCO accepts analog control inputs from the PLL filter block and generates a frequency that is used by the time unit generator to create discrete time units that are selected in the skew mix matrix. The operational range of the VCO is determined by the FS control pin. The time unit (tU) is determined by the operating frequency of the device and the level of the FS pin as shown in Table 1. Skew Select Matrix 1Fx 2Fx (N/A) Maximum Ratings Storage Temperature ...................................... -65C to +150C Ambient Temperature with Power Applied ................................................. -55C to +125C Supply Voltage to Ground Potential .................. -0.5V to +7.0V DC Input Voltage ...............................................-0.5V to +7.0V Output Current into Outputs (LOW) ............................... 64mA Static Discharge Voltage ............................................... >2001V (per MIL-STD-883, Method 3015) Latch-Up Current .........................................................>200mA t0 +6tU t0 +5tU t0 +4tU t0 +3tU t0 +2tU t0 t0 +1tU t0 -1tU t0 -2tU t0 -3tU t0 -4tU t0 -5tU t0 -6tU The skew select matrix is comprised of four independent sections. Each section has two low-skew, high-fanout drivers (xQ0, xQ1), and two corresponding three-level function select (xF0, xF1) inputs. Table 2 shows the nine possible output functions for each section as determined by the function select inputs. All times are measured with respect to the REF input assuming that the output connected to the FB input has 0tU selected. Operating Range FB Input REF Input 3Fx 4Fx LM -6tU LL LH -4tU LM (N/A) -3tU LH ML ML (N/A) -2tU -1tU MM MH MM (N/A) 0tU +1tU +2tU HL MH HM (N/A) +3tU HH HL +4tU Range Ambie nt Te mpe rature VCC Commercial 0C to +70C 3.3V 10% Industrial -40C to +85C 3.3V 10% Note: 3. FB connected to an output selected for "zero" skew (ie., xF1 = xF0 = MID). (N/A) HM +6tU (N/A) LL/HH Divided (N/A) HH Invert Figure 1. Typical Outputs with FB Connected to a Zero-Skew Output(3) 3 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Capacitance(6) Parame te r De s cription Te s t Conditions M ax. Units CIN Input Capacitance TA= 25C, f = 1MHz, VCC = 3.3V 10 pF Electrical Characteristics (Over the Operating Range) Parame te r De s cription Te s t Conditions M in. M a x. VOH Output HIGH Voltage VCC = Min., IOH = -12mA VOL Output LOW Voltage VCC = Min., IOL = 35mA VIH Input HIGH Voltage (REF & FB inputs only) 2.0 VCC VIL Input LOW Voltage (REF & FB inputs only) -0.5 0.8 2.4 0.45 V VIHH Three- Level Input HIGH Voltage (Test, FS, xFn)(4) Min. VCC Max. 0.87 VCC VCC VIMM Three- Level Input MID Voltage (Test, FS, xFn)(4) Min. VCC Max. 0.47 VCC 0.53 VCC VILL Three- Level Input LOW Voltage (Test, FS, xFn)(4) Min. VCC Max. 0.0 0.13 VCC IIH Input HIGH Leakage Current (REF & FB inputs only) VCC = Max., VIN = Max. IIL Input LOW Leakage Current (REF & FB inputs only) VCC = Max., VIN = 0.4V IIHH Input HIGH Current (Test, FS, xFn) VIN = VCC IIMM Input MID Current (Test, FS, xFn) VIN = VCC/2 -50 IILL Input LOW Current (Test, FS, xFn) VIN = GND -200 IOS ICCQ ICCN PD (5) 20 -20 A 200 Short Circuit Current VCC = Max., VOUT = GND (25C only) Operating Current Used by Internal Circuitry VCCN = VCCQ = Max., All Input Selects Open Output Buffer Current per Output Pair Power Dissipation per Output Pair Units 50 -200 mA Com'l 95 Mil/Ind 100 mA VCCN = VCCQ = Max., IOUT = 0mA All Input Selects Open, fMAX 19 mA VCCN = VCCQ = Max., IOUT = 0mA All Input Selects Open, fMAX 104 mW Notes: 4. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional tLOCK time before all data sheet limits are achieved. 5. PI6C3991 should be tested one output at a time, output shorted for less than one second, less than 10% duty cycle. Room temperature only. 6. Applies to REF and FB inputs only. Tested initially and after any design or process changes that may affect these parameters. 4 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Switching Characteristics PI6C3991 (Over the Operating Range)(2,7) Parame te r fNOM PI6C3991-2 De s cription Operating Clock Frequency in MHz M in. FS = LOW (1,2) FS = MID (1,2) Typ. M in. 30 15 15 FS = HIGH (1,2) PI6C3991-5 M a x. PI6C3991 Typ. M ax. 30 M in. 25 50 25 50 25 50 80 40 80 40 80 5.0 5.0 5.0 tRPWL REF Pulse Width LOW 5.0 5.0 5.0 Programmable Skew Unit See Table 1 Zero Output Matched- Pair Skew (XQ0, XQ1) tSKEW0 Zero Output Skew (All Outputs) (9,11) tSKEW1 (9,10) Output Skew (Rise- Rise, Fall- Fall, Same Class Outputs) (9,13) Divided- Divided)(9,13) tSKEW2 Output Skew (Rise- Fall, Nominal- Inverted, tSKEW3 Output Skew (Rise- Rise, Fall- Fall, Different Class Outputs)(9,13) tSKEW4 tDEV tPD Output Skew (Rise- Fall, Nominal- Divided, Divided- Inverted 30 40 REF Pulse Width HIGH tSKEWPR M ax. Units 15 tRPWH tU Typ. (9,13) See Table 1 ns See Table 1 0.05 0.2 0.1 0.25 0.1 0.25 0.1 0.25 0.25 0.5 0.3 0.75 0.1 0.5 0.6 0.7 0.6 1. 0 0.5 1.0 0.5 1.0 1.0 1.5 0.25 0.5 0.5 0.7 0.7 1.2 0.5 0.9 0.5 1.0 1.2 1.7 (8,14) Device- to- Device Dkew 1. 2 5 1.25 1.65 Propagation Delay, REF Rise to FB Rise -0.25 0.0 +0.25 -0.5 0.0 +0.5 -0.7 0.0 +0.7 tODCV Output Duty Cycle Variation(15) -0.65 0.0 +0.65 -1.0 0.0 +1.0 -1.2 0.0 +1.2 tPWH Output HIGH Time Deviation from 50% (16) (16) 2.0 2.5 3 1.5 3.0 3.5 tPWL Output LOW Time Deviation from 50% tORISE (16,17) Output Rise Time 0.15 1.0 1.2 0.15 1.0 1.5 0.15 1.5 2.5 tOFALL Output Fall Time(16,17) 0.15 1.0 1.2 0.15 1.0 1.5 0.15 1.5 2.5 tLOCK tJR (18) PLL Lock Time Cycle- to- cycle Output Jitter MHz 0.5 0.5 0.5 RMS(8) 25 25 25 Peak- to- peak(8) 200 200 200 ns ms ps Notes: 7. Test measurement levels for the PI6C3991 are TTL levels (1.5V to 1.5V). Test conditions assume signal transition times of 2ns or less and output loading as shown in the AC Test Loads and Waveforms unless otherwise specified. 8. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters. 9. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are loaded with 30pF and terminated with 50 Ohm to VCC/2. 10. tSKEWPR is defined as the skew between a pair of outputs (XQ0 and XQ1) when all eight outputs are selected for 0tU. 11. tSKEW0 is defined as the skew between outputs when they are selected for 0tU. Other outputs are divided or inverted but not shifted. 12. CL = 0pF. For CL = 30pF, tSKEW0 = 0.35ns. 13. There are three classes of outputs: Nominal (multiple of tU delay), Inverted (4Q0 and 4Q1 only with 4F0 = 4F1 = HIGH), and Divided (3Qx and 4Qx only in Divide-by-2 or Divide-by-4 mode). 14. tDEV is the output-to-output skew between any two devices operating under the same conditions (VCC ambient temperature, air flow, etc.) 15. tODCV is the deviation of the output from a 50% duty cycle. Output pulse width variations are included in tSKEW2 and tSKEW4 specifications. 16. Specified with outputs loaded with 30pF for the PI6C3991 and PI6C3991-5 devices. Devices are terminated through 50 Ohm to VCC/ 2. tPWH is measured at 2.0V. tPWL is measured at 0.8V. 17. tORISE and tOFALL measured between 0.8V and 2.0V. 18. tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VCC is stable and within normal operating limits. This parameter is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits. 5 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 AC Test Loads and Waveforms TTL AC Test Load TTL Input Test Waveform VCC 1ns R1 CL 1ns 3.0V 2.0V Vth=1.5V 0.8V 0V R2 R1=100 R2=100 CL=30pF (Includes fixture and probe capacitance) AC Timing Diagrams tREF tRPWH tRPWL REF tPD tODCV tODCV FB tJR Q tSKEWPR tSKEW0, 1 tSKEWPR tSKEW0, 1 Other Q tSKEW2 tSKEW2 Inverted Q tSKEW3,4 tSKEW3,4 tSKEW3,4 REF Divided by 2 tSKEW1,3,4 tSKEW2,4 REF Divided by 4 6 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Operational Mode Descriptions REF FB System Clock LOAD REF L1 FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 Z0 LOAD L2 Z0 L3 LOAD Z0 L4 Z0 TEST LOAD LENGTH: L1 = L2 = L3 = L4 Figure 2. Zero-Skew and/or Zero-Delay Clock Driver Figure 2 shows the SuperClock configured as a zero-skew clock buffer. In this mode the PI6C3991 can be used as the basis for a lowskew clock distribution tree. When all of the function select inputs (xF0, xF1) are left open, the outputs are aligned and may each drive a terminated transmission line to an independent load. The FB input can be tied to any output in this configuration and the operating frequency range is selected with the FS pin. The low-skew specification, coupled with the ability to drive terminated transmission lines (with impedances as low as 50 Ohm), allows efficient printed circuit board design. REF FB System Clock LOAD REF L1 FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 Z0 LOAD L2 Z0 L3 LOAD Z0 L4 Z0 TEST LOAD LENGTH: L1 = L2, L3 < L2 by 6", L4 > L2 by 6" Figure 3. Programmable Skew Clock Driver 7 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Figure 3 shows a configuration to equalize skew between metal traces of different lengths. In addition to low skew between outputs, the SuperClock can be programmed to stagger the timing of its outputs. The four groups of output pairs can each be programmed to different output timing. Skew timing can be adjusted over a wide range in small increments with the appropriate strapping of the function select pins. In this configuration the 4Q0 output is fed back to FB and configured for zero skew. The other three pairs of outputs are programmed to yield different skews relative to the feedback. By advancing the clock signal on the longer traces or retarding the clock signal on shorter traces, all loads can receive the clock pulse at the same time. In this illustration the FB input is connected to an output with 0ns skew (xF1, xF0 = MID) selected. The internal PLL synchronizes the FB and REF inputs and aligns their rising edges to insure that all outputs have precise phase alignment. Clock skews can be advanced by 6 time units (tU) when using an output selected for zero skew as the feedback. A wider range of delays is possible if the output connected to FB is also skewed. Since "Zero Skew", +tU, and -tU are defined relative to output groups, and since the PLL aligns the rising edges of REF and FB, it is possible to create wider output skews by proper selection of the xFn inputs. For example a +10 tU between REF and 3Qx can be achieved by connecting 1Q0 to FB and setting 1F0 = 1F1 = GND, 3F0 = MID, and 3F1 = High. (Since FB aligns at -4 tU and 3Qx skews to +6 tU , a total of +10 tU skew is realized). Many other configurations can be realized by skewing both the output used as the FB input and skewing the other outputs. Figure 4 shows an example of the invert function of the SuperClock. In this example the 4Q0 output used as the FB input is programmed for invert (4F0 = 4F1 = HIGH) while the other three pairs of outputs are programmed for zero skew. When 4F0 and 4F1 are tied HIGH, 4Q0 and 4Q1 become inverted zero phase outputs. The PLL aligns the rising edge of the FB input with the rising edge of the REF. This causes the 1Q, 2Q, and 3Q outputs to become the "inverted" outputs with respect to the REF input. By selecting which output is connect to FB, it is possible to have 2 inverted and 6 non-inverted outputs or 6 inverted and 2 non-inverted outputs. The correct configura-tion would be determined by the need for more (or fewer) inverted outputs. 1Q, 2Q, and 3Q outputs can also be skewed to compensate for varying trace delays independent of inver-sion on 4Q. REF FB 20 MHz REF FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 40 MHz 20 MHz 80 MHz TEST REF Figure 5. Frequency Multiplier with Skew Connections FB REF Figure 5 illustrates the SuperClock configured as a clock multiplier. The 3Q0 output is programmed to divide by four and is fed back to FB. This causes the PLL to increase its frequency until the 3Q0 and 3Q1 outputs are locked at 20 MHz while the 1Qx and 2Qx outputs run at 80 MHz. The 4Q0 and 4Q1 outputs are programmed to divide by two, which results in a 40 MHz waveform at these outputs. Note that the rising edges of 4Qx and 3Qx outputs are aligned. The 2Q0, 2Q1, 1Q0, and 1Q1 outputs run at 80 MHz and are skewed by programming their select inputs accordingly. Note that the FS pin is wired for 80 MHz operation because that is the frequency of the fastest output. FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 TEST Figure 4. Inverted Output Connections 8 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 offer divide-by-2 and divide-by-4 timing. An inverted output allows the system designer to clock different sub-systems on opposite edges, without suffering from the pulse asymmetry typical of nonideal loading. This function allows the two subsystems to each be clocked 180 degrees out of phase, but still to be aligned within the skew spec. The divided outputs offer a zero-delay divider for portions of the system that need the clock to be divided by either two or four, and still remain within a narrow skew of the "1X" clock. Without this feature, an external divider would need to be add-ed, and the propagation delay of the divider would add to the skew between the different clock signals. These divided outputs, coupled with the Phase Locked Loop, allow the SuperClock to multiply the clock rate at the REF input by either two or four. This mode will enable the designer to distribute a lowfrequency clock between various portions of the system, and then locally multiply the clock rate to a more suitable frequency, while still maintaining the low-skew characteristics of the clock driver. The SuperClock can perform all of the functions described above at the same time. It can multiply by two and four or divide by two (and four) at the same time that it is shifting its outputs over a wide range or maintaining zero skew between selected outputs. REF FB 20 MHz REF FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 10 MHz 5 MHz 20 MHz TEST Figure 6. Frequency Divider Connections Figure 6 demonstrates the SuperClock in a clock divider application. 2Q0 is fed back to the FB input and programmed for zero skew. 3Qx is programmed to divide by four. 4Qx is programmed to divide by two. Note that the rising edges of the 4Qx and 3Qx outputs are aligned. The 1Qx outputs are programmed to zero skew and are aligned with the 2Qx outputs. In this example, the FS input is grounded to configure the device in the 15 to 30 MHz range since the highest frequency output is running at 20 MHz. Figure 7 shows some of the functions that are selectable on the 3Qx and 4Qx outputs. These include inverted outputs and outputs that REF LOAD FB 20 MHz Distribution Clock REF Z0 FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 80 MHz Inverted LOAD 20 MHz 80 MHz Zero Skew 80 MHz Skewed -3.125ns (-4tU) TEST Z0 LOAD Z0 Z0 LOAD Figure 7. Multi-Function Clock Driver 9 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 REF LOAD System Clock FB Z0 L1 REF FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 LOAD L2 Z0 L3 LOAD Z0 L4 TEST FB Z0 REF FS 4F0 4Q0 4F1 4Q1 3F0 3Q0 3F1 3Q1 2F0 2Q0 2F1 2Q1 1F0 1Q0 1F1 1Q1 LOAD LOAD TEST Figure 8. Board-to-Board Clock Distribution Figure 8 shows the PI6C3991 connected in series to construct a zero skew clock distribution tree between boards. Delays of the down stream clock buffers can be programmed to compensate for the wire length (i.e., select negative skew equal to the wire delay) necessary to connect them to the master clock source, approximating a zero- delay clock tree. Cascaded clock buffers will accumulate low-frequency jitter because of the non-ideal filtering characteristics of the PLL filter. It is recommended that not more than two clock buffers be connected in series. 10 PS8450D 11/12/08 PI6C3991 3.3V High-Speed, Low-Voltage Programmable Skew Clock Buffer - SuperClock(R) 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Package Diagram - 32-Pin PLCC (J) Ordering Information Accuracy (ps ) Orde ring Code Package Name Package Type Ope rating Range 750 PI6C3991- JE J32 32- Pin Plastic Leaded Chip Carrier Commercial 250 PI6C3991- 2JE J32 32- Pin Plastic Leaded Chip Carrier Commercial 500 PI6C3991- 5JE J32 32- Pin Plastic Leaded Chip Carrier Commercial Notes: * Thermal characteristics can be found on the company web site at www.pericom.com/packaging/ * E = Pb-free & Green * X suffix = Tape/Reel Pericom Semiconductor Corporation * 1-800-435-2336 * http://www.pericom.com 11 PS8450D 11/12/08