Keysight 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB An integrated AC power solution Data Sheet -- Provides a complete AC and DC power and measurement solution -- Protect valuable DUTs with extensive protection features -- Easy to use graphical user interface (GUI) The Complete AC Power Test Solution Keysight Technologies, Inc., AC power source/analyzers provide a complete AC test solution. As AC sources, they combine the capabilities of a power amplifier and an arbitrary waveform generator. This allows you to simulate normal waveforms and many types of distorted power waveforms. The built in power analyzer combines the capabilities of a multimeter, oscilloscope, harmonic analyzer and power analyzer. These instruments may also be used to produce DC power, either alone or as a DC offset to an AC waveform. Since your product will have to operate in the real world of unpredictable AC power, you need to design and verify its correct operation under a wide range of AC power inputs. Brownouts, dropouts, sags, and other irregularities are not unusual in many communities today. Keysight AC power source/analyzers have the features needed to easily accomplish this test goal either in an R&D environment or on the manufacturing test floor. If you plan to sell your products in a worldwide market, you will also need to test them at the line voltages and frequencies for which they will eventually operate. There is also additional testing needed to meet regulatory requirements for sale into some countries. Keysight AC power source/analyzers offer a complete solution for AC power testing, helping you to simplify this important task. These instruments combine the features of a power amplifier and arbitrary waveform generator to give you the ability to do all of the tests that you need. There are many standard preprogrammed waveforms, or you can use the transient generation system to simulate sophisticated and repeatable AC line disturbances. DC power can also be generated, either as a DC offset or as a pure DC signal. 03 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Powerful Built-in Measurement Capabilities Keysight AC power source/analyzers have extensive 16-bit precision measurement capabilities which would normally require a number of complex measurement instruments, including a DMM (digital multimeter), oscillo-scope, power analyzer, and harmonic analyzer. The precision measurements include: -- rms, DC, AC + DC voltage and current -- Peak voltage and current -- Real, apparent, and reactive power -- Harmonic analysis of voltage and current waveforms providing amplitude and phase up to the 50th harmonic -- THD (total harmonic distortion) -- Triggered acquisition of digitized voltage and current Using the measurement capabilities of a Keysight AC power source/analyzer simplifies your test setups and helps you obtain accurate data quickly. Dual power analyzer Option 020 The powerful built-in power meter/ analyzer in Keysight AC power source/analyzers provides everything that you need to make AC measurements at the AC input to your DUT. For many test scenarios, this is the extent of the AC analysis required. Some test scenarios, however, require AC measurements to be made at both the AC input and the AC output of the DUT. Option 020 provides an additional power analyzer, complete with a precision current shunt, which can be connected anywhere you need it. This second analyzer can even be used for tests where the AC power source/analyzer is not providing power, thus expanding the usefulness of this instrument to many more test configurations. The additional analyzer is equivalent in specifications and capabilities to the standard analyzer. Using the dual power analyzer option instead of an additional power analyzer instrument externally is more than just convenient. Measurements on all four measurement channels (AC source output voltage and current, and dual power analyzer voltage and current inputs) are inherently synchronized with the AC power source/analyzers output waveform. This precision would be difficult to achieve using separate measurement instruments. Examples dual power analyzer applications -- Complete testing of uninterruptible power sources (UPS) -- Efficiency testing of DC power supplies -- Efficiency testing of AC power sources -- Efficiency testing of transformers -- Safety testing of transformers -- Line disturbance and brownout testing of DC power supplies -- Line disturbance and brownout testing of AC power sources -- Sleep mode current monitoring -- Independent power analyzer 04 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Sleep mode current monitoring Many electronic products have power-saving or sleep modes. In this mode, the device draws only enough power to be able to recognize a "wake-up" signal, and then execute a smooth "wake-up". The power drawn in this mode is a critical parameter, and the ability to accurately monitor it is important. The accessory precision current shunt that is supplied with option 020 is mounted in such a way to make it easy for you to replace it with a precision resistor of your choice. By doing this, you can configure the system to accurately monitor extremely low currents. This provides an easy way for you to profile the current draw in all modes of your product's operation. Since Keysight 6811B-6813B AC power source/analyzers produce DC power as well as AC power, portable battery operated products can also be tested with this configuration. UPS (uninterruptible power source) testing The dual power analyzer option provides many important benefits for UPS testing. Since the key to correct UPS operation is having the output react properly to changes on the input, being able to monitor the output relative to the input simplifies testing. For example, commands are available to enable calculation of UPS transfer time, and the phase difference between the UPS input and output voltage. Keysight AC power source/analyzers also have programmable output impedance, enabling the UPS designer to verify product stability over a wide range of AC line impedance. Graphical user interface (GUI) When you need to run a variety of tests, study the results carefully, and then run more tests with slightly varied conditions, writing computer programs using the extensive SCPI command set may seem burdensome. This is when you should download the latest copy of the Keysight AC power source/analyzer graphical user interface from www.keysight.com/find/6800. The AC power source/analyzer GUI makes it quick and easy to set the output of your AC power source/analyzer, be it from a stored waveform or with a waveform that you create using your mouse. The GUI also allows you to see the output of the AC power source/ analyzer in graphical form, save the results, or dump them directly into a Microsoft Excel file. Microsoft Excel link The direct Excel link feature was recently added to meet the current needs of R&D engineers. It makes it easy to keep the results of many tests, and makes them easily retrievable. With it, the test records resulting from changing conditions can be kept in one place and easily compared. Access to raw data often helps in fully understanding test results. For example, small local peaks may not be evident in processed data. V, I and phase results from harmonic measurements are particularly susceptible to not showing the complete story in a graphical representation. Microsoft Excel offers a wide variety of data manipulation and graphical capabilities that can help an engineer gain the fullest understanding from the test data. Test suite for avionics equipment Keysight AC power source/analyzers are well suited for testing equipment intended for use in the avionics industry which operate at nominally 400 Hz. One of the special requirements that many manufacturers in this industry must concern themselves with is testing to meet RTCA DO-160 standards. 05 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet These standards involve both AC and DC immunity tests. The AC power source/analyzer GUI includes a section devoted to these tests. By using this tool, you can quickly step through the required set-ups with confidence. Only need a basic AC source? The AC6800 Series of basic AC sources offer models up to 4000 VA with LAN/LXI Core, USB and optional GPIB. For more information, see Extensive protection to prevent load damage In addition to overcurrent, overvoltage, overpower and overtemperature protection, the 6800 series offers output disconnect relays and remote inhibit capability (quickly disabling the output of the AC power source/analyzers via a TTL signal) to protect the device under test. www.keysight.com/find/ACSources Application information The 6800 series can help you test and improve your products. You can easily perform: -- Static testing-generating and measuring voltage, frequency, and line current for meeting worldwide specifications. -- Dynamic testing-generating AC line transients for limit testing and design verification. -- Specialty testing-measuring current harmonic content and creating custom AC power waveforms (such as a combined AC + DC signal to simulate a telephone ring). -- Precompliance regulatory testing--measuring current harmonics, voltage fluctuations and flicker emissions and generating voltage and frequency disturbances and interharmonics to determine product immunity. Development engineers and test professionals in a wide variety of industries use AC power source/analyzers. Here are a few examples: -- Avionics - Instrumentation, ATE test stations -- Computer products - Computers, monitors, peripherals -- Consumer products - Home appliances, audio and video equipment, heating/cooling controls -- Electrical products - Relays, transformers, power components, fire alarms -- Lighting products - Electronic ballasts, compact fluorescent bulbs, timers -- Motors - AC motors, electronic controllers -- Power products - AC/DC adapters, AC/DC power supplies, PBX power supplies, uninterruptible power supplies -- Telecom products - RF amplifiers, CATV devices, MUX's, routers, switches Keysight AC power source/analyzer with dual power analyzer option (side view) AC in AC source output Keysight supplied cable (for V and I) Equipment under test Keysight supplied shunt Output Shunt Line Load Load Dual power analyzer input (for V and I) AC line cables (customer supplied) Test of efficiency measurement anKeysight Keysight AC source with dual power analyzer option. Figureconfiguration 1. Test configuration of efficiency measurement using using an AC source with the 020the dual020 power analyzer option. 06 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet AC Power Source/Analyzer Graphical User Interface Figure 2. Inrush current measurement Figure 3. Ringer voltage (DC + AC) generation Figure 4. Voltage slew control (brownout) Figure 5. One cycle AC mains dropout Figure 6. User defined waveform: noise with spikes Figure 7. Testing of UPS input and output using dual power analyzer - Option 020 07 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Specifications For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. Specifications (at 0 to 40 C unless otherwise specified) 6811B 6812B 6813B Number of phases 1 1 1 Power 375 VA 750 VA 1750 VA rms voltage 300 V 300 V 300 V rms current 3.25 A 6.5 A 13 A Repetitive & non-repetitive peak current 40 A 40 A 80 A Crest factor 12 6 6 Load power factor capability 0 to 1 0 to 1 0 to 1 DC power 285 W 575 W 1350 W DC voltage 425 VA 425 V 425 V DC current Output ratings (Maximum) 2.5 A 5.0 A 10.0 A Output frequency range1 DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz Constant voltage ripple and noise (20 kHz to 10 MHz) -60 dB (relative to full scale) -60 dB (relative to full scale) -60 dB (relative to full scale) Line regulation (% of full scale) 0.1% 0.1% 0.1% Load regulation (% of full scale) 0.5% 0.5% 0.5% Maximum total harmonic distortion 0.25% at 50/60 Hz 0.25% at 50/60 Hz 0.25% at 50/60 Hz 1% worst case 1% worst case 1% worst case 45 to 1 kHz 45 to 1 kHz 45 to 1 kHz Programming accuracy (at 25 5 C) 6811B 6812B 6813B RMS voltage (% of output + offset) 0.15% + 0.3 V (45 to 100 Hz) 0.15% + 0.3 V (45 to 100 Hz) 0.15% + 0.3 V (45 to 100 Hz) 0.5% + 0.3 V (> 100 to 500 Hz) 0.5% + 0.3 V (> 100 to 500 Hz) 0.5% + 0.3 V (> 100 to 500 Hz) 1% + 0.3 V (> 500 to 1000 Hz) 1% + 0.3 V (> 500 to 1000 Hz) 1% + 0.3 V (> 500 to 1000 Hz) DC voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V Frequency 0.01% + 10 Hz 0.01% + 10 Hz 0.01% + 10 Hz 1. Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 s per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid aliasing effects. 08 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Specifications, continued For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. Measurement accuracy (at 25 55 C) 6811B 6812B Rms. voltage (45 - 100 Hz) 0.03% + 100 mV DC voltage 0.05% + 150 mV 6813B 1 1 0.03% + 100 mV 1 0.03% + 100 mV1 1 0.05% + 150 mV 0.05% + 150 mV1 RMS current (45 - 100 Hz)2 High range 0.05% + 10 mA 0.05% + 10 mA 0.05% + 10 mA Low range 0.05% + 1.5 mA 0.05% + 1.5 mA 0.05% + 1.5 mA High range 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V Low range 0.1% + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V High range 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V Low range 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V Frequency 0.01% + 0.01 Hz 0.01% + 0.01 Hz 0.01% + 0.01 Hz Power factor 0.01 0.01 0.01 Fundamental 0.03% + 1.5 mA 0.03% + 1.5 mA 0.03% + 1.5 mA Harmonics 2-49 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz Fundamental 0.05% + 5 mA 0.05% + 5 mA 0.05% + 5 mA Harmonics 2-49 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz 6811B 6812B 6813B 1.2% + 50 mA 1.2% + 50 mA 1.2% + 50 mA rms voltage 125 mV 125 mV 125 mV DC voltage 250 mV 250 mV 250 mV Overvoltage programming (OVP) 2 V peak 2 V peak 2 V peak rms current 2 mA 4 mA 4 mA Peak current 1.25 mA 25 mA 25 mA Output frequency 10 Hz 10 Hz 10 Hz Phase N/A N/A N/A Power (VA) (45-100 Hz) 2 Power (watts) (45-100 Hz)2 Current magnitude (low range) Current magnitude (high range) Supplemental characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average programming accuracy (% of output + offset) rms current Average programming resolution 1. Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 seconds per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid aliasing effects. 2. Select low measurement range for improved accuracy (10:1) for lower power measurements. 09 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Specifications, continued For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. Supplemental characteristics (Non-warranted characteristics determined by design and useful in applying the product) 6811B 6812B 6813B rms voltage 10 mV 10 mV 10 mV rms current 2 mA 2 mA 2 mA Resistance 0-1 0-1 0-1 Inductance Average measurement resolution Programmable output impedance 20 h - 1 mh 20 h - 1 mh 20 h - 1 mh Remote sense capability Up to 1 Vrms can be dropped across each load lead Up to 1 Vrms can be dropped across each load lead Up to 1 Vrms can be dropped across each load lead Isolation to ground 300 Vrms/425 VDC 300 Vrms/425 VDC 300 Vrms/425 VDC Net weight 28.2 kg (62 lb) 28.2 kg (62 lb) 32.7 kg (72 lb) Shipping weight 31.8 kg (70 lb) 31.8 kg (70 lb) 36.4 kg (80 lb) AC input ratings 6811B 6812B 6813B 87 to 106 VAC *104 to 127 VAC 87 to 106 VAC *104 to 127 VAC 174 to 220 VAC *191 to 254 VAC 174 to 220 VAC 174 to 220 VAC 191 to 254 VAC 191 to 254 VAC 12 A (100 VAC) 28 A (100 VAC) 10 A (120 VAC) 24 A (120 VAC) 7.5 A (200/208 VAC) 15 A (200/208 VAC) 6.5 A (230 VAC) 13 A (230 VAC) Input power (max) (Measured at high line) 1000 VA/700 W 2500 VA/1400 W 3800 VA/2600 W Input frequency 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz Voltage range (VAC) *default factory setting Maximum input current (rms) (Measured at low line) Supplemental characteristics for all model numbers Software driver: Size: VXIplug&play 425.5 mm W x 88.1 mm H x 396 mm D (16.75 in x 3.5 in x 13.7 in ) Warranty: Three years 22 A (200/208 VAC) 20 A (230 VAC) 10 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Ordering Information The 6800 Series AC power source/analyzers come with full documentation on CD-ROM. The CD-ROM includes user's guide, programming guide, GUI quick reference guide, service manual, quick start guide, and application notes. Opt 019 Opt 020 Opt 026 Output raised to 2000VA, frequency reduced to 100Hz (6813B only) Dual power analyzer option 26 Volt, 0.1 A auxiliary 45 to 100 Hz only, reference output (6812B and 6813B) Opt 0B3 Opt 0L1 Printed service manual Printed user's, programming, and quick start guides; printed reference card Opt 100 Opt 120 Opt 200 Opt 208 Opt 230 Opt 831 Opt 832 Opt 833 Opt 834 Opt 841 Opt 842 Opt 844 Opt 845 Opt 846 Opt 847 Opt 848 (6811B and 6812B only) 87 to 106 VAC (100 VAC nominal), 47-63 Hz, Japan only 104-127 VAC (120 VAC nominal), 47-63 Hz (6813B only) 174-220 VAC (200 VAC nominal), 47-63 Hz, Japan only (6811B and 6812B only) 174 to 220 VAC (208 VAC nominal), 47-63 Hz 191 to 254 VAC (230 VAC nominal), 24-63 Hz 12 AWG, 200 to 240 VAC, unterminated (6812B, 6813B only) 4 mm2 wire size, (unterminated (6813B only) 1.5 mm2 wire size, 200 to 240 VAC, unterminated (6812B only) 10 AWG, 100 to 120 VAC, unterminated (6812B only) Line cord with NEMA L6-20P; 20 A, 250 V plug (6812B only) Line cord with IEC 309; 32 A, 220 V plug (6813B only) Line cord with NEMA L6-30P; 30 A, 250 V locking plug (6813B only) Line cord with IEC 309; 16 A, 220 V plug (6812B only) Line cord with NEMA L6-30P; 30 A, 120 V plug (6812B only) Line cord with CEE 7/7; 16 A, 220 V plug (6812B only) Line cord with BS 546; 15 A, 240 V plug (6812B only) Accessories 1CM003A1 1CP002A1 E3663AC 1. Rack mount flange kit 132.6 mm H (3U) - two flange brackets Rack mount flange and handle kit 132.6 mm H (3U) - two brackets and front handles Support rails for Keysight rack cabinets Support rails required. 11 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet Application Notes Keysight 6800 Series AC Power Source/Analyzer - Application Note http://literature.cdn.keysight.com/litweb/pdf/5963-7044E.pdf 5963-7044E Testing Uninterruptible Power Supplies Using Keysight 6800 Series AC Power Source/Analyzers - Application Note http://literature.cdn.keysight.com/litweb/pdf/5967-6056E.pdf 5967-6056E Simplify your Avionics Testing with a 400 Hz Single Phase Power Source that Includes a Built-in 26 V Reference Signal - Application Note http://literature.cdn.keysight.com/litweb/pdf/5989-3700EN.pdf 5989-3700EN Top Top 574.7 mm 22.63" 425.5 mm 16.75" 132.6 mm 5.2" 128 mm 5.04" Terminal strip Screw size: 6-32 Rear Rear 12.7 mm 0.5" Figure 8. Keysight models: 6811B, 6812B, 6813B 50.8 mm 2.0" Side Side 12 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. Unlocking Measurement Insights For more than 75 years we have been helping you unlock measurement insights, first as the electronic measurement businesses of Hewlett-Packard and Agilent Technologies, and now, as Keysight Technologies. Our unique combination of hardware, software and people can help you see what others can't, so you can reach your next breakthrough. www.keysight.com/find/ACSources For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 0124 229 2010 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-02-06-15) This information is subject to change without notice. (c) Keysight Technologies, 2012 - 2015 Published in USA, March 12, 2015 5990-9309EN www.keysight.com