Du line Master Channel Generator Types G 3800 0015, G 3800 1015 (R) Fieldbus Installationbus * Programmable channel generator * Option for built-in GSM Modem for monitoring and control via SMS * User-friendly configuration via Windows 98/2000/NT/XP software * Real-time, timer and logic functions * Analog set-point control and monitoring * Light and Rollerblind control functions * Alarm Monitoring * Option for Radio controlled clock for high real time accuracy * 2 x RS232 ports for configuration and Dupline data read/write * 1 x RS485 port for networking of up to 32 Master Generators * Modbus-RTU protocol * Built-in software driver for external radio modem * 4 digital inputs / 4 digital outputs on-board * H8-housing for DIN-rail mounting (EN50022) * AC or DC power supply Product Description Programmable channel generator with built-in dedicated intelligent functions for light and roller blind control, alarm monitoring and analog setpoint control. In addition to that, there is realtime-, timerand logic- functions. Programming is easily performed through Windows-based configuration software. An optional built-in GSM modem Ordering Key can be used for monitoring and control of Dupline signals via SMS. Up to 32 Master generators can be networked as slaves in a RS485 network using the Modbus protocol. The unit has 4 digital inputs and 4 digital outputs onboard, and it is possible to create links to other Dupline networks via external Radio Modem. G 3800 1015 230 Type: Dupline(R) H8-housing GSM phone Master channel generator Supply Type Selection Supply Ordering no. Ordering no. w. GSM telephone 115/230 VAC 10-30 VDC G 3800 0015 230 G 3800 0015 800 G 3800 1015 230 G 3800 1015 800 Input/Output Specifications Serial Port COM 1 COM 2 Data format COM 1, COM 2 Pin assignment TxD RxD GND Dielectric voltage Com.port - Dupline(R) Protocol RS 485 Termination Fs-B Fs-A + (B) - (A) GND V+ Protocol Dupline(R) Output Output voltage Current Short-circuit protection Sequence time 32 channels 128 channels RS 232 115 kBaud 9600 Baud, adjustable 8 bit No parity 1 stop bit 9-pole female SUB-D Pin 2 Pin 3 Pin 5 2 kVAC (rms) Modbus-RTU Pin 27 When in use, connect to pin 31 Pin 28 When in use, connect to pin 30 Pin 29 When in use, connect to pin 31 Pin 30 Pin 31 Pin 32 Pin 33*) Modbus-RTU Dupline(R) carrier 8.2 V < 130 mA Yes Digital outputs Function Output voltage VDD Output current Output voltage drop Off-state leakage current Short-circuit protection Built-in protective diodes Dielectric voltage Output - Dupline(R) Output - Input Inductive loads Inputs Digital Voltage Current Dielectric voltage Input - Dupline (R) GSM Modem Siemens cellular engine Dual Band Output power Antenna connector *) 4 PNP transistors Programmable 35 VDC 100 mA 2V 100 A None None 4 kVAC (rms) 200 V External noise suppression required 6 - 30 VDC ON > 5.5 V OFF < 1.5 V 6 mA 4 kVAC TC35 EGSM900 and GSM1800 Class 4 (2 W) EGSM900 Class 1 (1 W) GSM1800 FME V+ and GND may be used as supply for digital I/O's, if RS 485 is not used. 38.6 ms 132.3 ms Specifications are subject to change without notice (21.08.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 1 Du line G 3800 0015, G 3800 1015 (R) Fieldbus Supply Specifications Power supply AC-Types Rated operational voltage through term. 21 & 24 jumper term. 22 & 23 Power on term. 21 & 23 Neutral on term. 22 & 24 Frequency Rated operational power Power dissipation G 38000015 G 38001015 Rated impulse withstand voltage 230 V 115 V Dielectric voltage Supply - Dupline(R) Supply - Output Supply - Input Supply - Com. ports Heat dissipation Supply Specifications G 38001015 Inrush current Rated impulse withstand volt. Dielectric voltage Supply - Dupline(R) Supply - Output Overvoltage cat. III (IEC 60664) 230 VAC 15% (IEC 60038) 115 VAC 15% (IEC 60038) 45 to 65 Hz Typ. 7 VA/3 W Real-time clock Accuracy Internal back-up time 4 kV Power ON delay 2.5 kV Indication for 4 kVAC (rms) Supply ON 4 kVAC (rms) ON Line 4 kVAC (rms) COM 1 4 kVAC (rms) COM 2 4W RS 485 GSM Overvoltage cat. III (IEC 60664) Environment Degree of protection 10 to 30 VDC Pollution degree Operating temperature - 50 Hz for synchronizing Storage temperature the clock Humidity (non-condensing) - in case of voltage break (AC) the log will automatically Mechanical resistance Shock update itself until 10 mSec Vibration before the loss of current Yes Dimensions 6W Material (see "Technical Information") 6W Weight Reverse polarity protection Rated operational power Power dissipation G 38000015 7W 1A 800 V 500 V 200 V General Specifications 6W 7W Power supply DC-Types Rated operational voltage through term. 21 & 22 DC supply terminal 24 and 25 Installationbus Better than 1 minute/month Typ. 48 hours < 2.5 s LED, green LED, yellow LED, red LED, red LED, red LED, red IP 20 3 (IEC 60664) 0 to +50C (+32 to +122F) -20 to +85C (-4 to +185F) 20 to 80% RH 15 G (11 ms) 2 G (6 to 55 Hz) H8-housing 640 g Wiring Diagrams 6-30 VDC V+ DUPLINE 1 2 D+ D- 3 1 4 5 6 7 1 2 3 8 9 10 2 3 4 V+ VIN 4 11 G 3800 0015 230 V- 12 13 14 15 16 0,1 A 30 V 1 2 3 4 12 VA Inputs 21 P 22 115V 23 N P 24 115V 25 26 27 T 28 Outputs 29 30 Fs-B Fs-A (B) N T Fs-B Fs-A 32 33 34 35 36 V- V+ V+ S-in V - 31 (A) RS 485 Out Supply DUPLINE 1 2 + - 21 22 6-30 VDC D+ D- 3 4 1 5 6 V+ 3 8 9 10 1 2 3 4 V+ VIN 4 7 11 G 3800 0015 800 V- 12 13 14 15 16 1 2 3 4 Inputs 23 24 25 26 27 T Supply 10-265 VAC 10-30 VDC AC monit. input 2 2 Radio Contr. Clock Outputs 28 29 30 Fs-B Fs-A (B) 31 (A) RS 485 32 V- Out 33 V+ 34 35 36 V+ S-in V - Radio Contr. Clock Specifications are subject to change without notice (21.08.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group Du line G 3800 0015, G 3800 1015 (R) Fieldbus Installationbus Mode of Operation Intelligent functions The G3800X015 Master Generator is a programmable channel generator which is particularly well suited for building automation applications due to the dedicated intelligent functions for lighting control, roller blind control, temperature control and alarm monitoring. In addition to that, the unit can be configured to perform real-time, logic and timer functions. The Windowsbased configuration software is extremely easy to use due to the pre-programmed functions. Master Generator configuration The Master Generator is as default configured to operate as a standard channel generator without intelligent functions. In order to make use of the intelligent functions, the Master Generator must be configured by means of the user-friendly Windows-based configuration software. This is included in the package and has to be installed on a Win 95/98/2000/NT/XP PC. When the configuration is completed, the configuration is downloaded into the Master Generator via COM1 (RS232 port). The configuration can be saved on a file, and it is also possible to upload the configuration from a Master Generator. GSM Modem Option The G38001015 Master Generator has a built-in GSM Modem which enables monitoring and control of Dupline signals via SMS messages to/from mobile GSM telephones. There are 3 different ways to use SMS messaging: * The Master Generator can be programmed to send out eventbased SMS messages. The event can be a channel switching ON or OFF, or it can be an analog signal crossing a setpoint. * Requests for status of digital or analog data can be sent and answered via SMS messages * Status of digital channels can be controlled by sending commands via SMS messages In order to make use of the GSM modem, the following is required: * A SIM-card with the pin-code 9090 needs to be inserted into the slot in the front of G38001015. The SIM-card must be a 3V type. * A GSM antenna needs to be connected to the FME connector on G38001015. If the unit is installed in a metal enclosure, the antenna must be installed outside the enclosure and connected to the Master Generator via a cable (an antenna of this type is available as accessory). An LED in the front of G38001015 indicates the status of the GSM modem. By emitting different blink patterns, the LED indicates "connecting", "SIMcard missing", "No network found", "No response from modem", "SMS sent" and "SMS received". Radio Controlled Clock Option It is possible to equip the G3800X015 with an external antenna for radio-controlled clock in order to achieve high timing accuracy in connection with real-time functions and event time stamps. When the antenna ANT2 is used, the G3800X015 will receive accurate timing signals from the DCF77 transmitter located in Frankfurt a.M., Germany. The antenna outputs the demodulated signals to the Master Generator via an open collector driver. The DCF77 transmitter covers all of Central Europe since the transmission radius is at least 1000 km. For longer distance the use of ANT2 depends on receiver conditions. ANT2 connects to the G3800X015 terminals. RS232 ports The Master Generator is provided with two RS232 ports (COM1 and COM2) which both can be used by PC's/PLC's for read/write of Dupline data using the Modbus-RTU protocol. COM1 is also used for download and upload of configuration files (created by the Master Generator configuration software) and for firmware upgrades. If the option for an external radio modem is desired, it needs to be connected to COM2. COM1 has a fixed baudrate of 115 kBaud, while the baudrate of COM2 is adjustable. RS485 port The RS485 port enables networking of up to 32 Master Generators operating as ModbusRTU slaves. This makes it possible for a PC or PLC operating as RS485 Modbus-RTU Master to read/write data from any of the 32 Master Generators. Each unit must be assigned a device address via the configuration software. In total, the RS485 network makes up to 4096 Dupline I/O points accessible from the PC or PLC. Find below a RS485 networking diagram. Modbus-RTU protocol Using the Modbus-RTU commands 2 and 3 through COM1, COM2 or RS485 makes it possible to read any type of Dupline data (digital, analink, multiplexed analog or counter data). The status of digital and multiplexed analog data and reset of counter can be controlled via the commands 5, 6 and 16. See manual for memory map information. Software The Dupline Data Access software package (type no. DUPDATACC) has been developed specifically for the Master Generator. It contains two software tools that provide easy access from a PC to Dupline digital, analog and counter data via one of the RS232 or RS485 ports. The DDE-driver provides a Dynamic Data Exchange interface, which can be used from applications that support client side DDE such as Microsoft EXCEL. Getting Dupline data into an EXCEL spreadsheet is a simple copy-and-paste operation. The Dupline ActiveX driver provides an ActiveX interface, which is a Microsoft standard for communication between two products. The Dupline ActiveX driver can be used from any development tool that supports client side ActiveX such as Microsoft Visual Basic, Delphi and Borland C++ builder. The Dupline Data Access package can be used on single Master Generators as well as Master Generator networks. continuously polling and updating the Dupline data from all remote MGEN's via the radio modem network, and in this way it makes the entire system operate as one big Dupline network. Apart from increased reaction time (depending on the number of remote MGEN's), the system will operate as if it was one Master Generator connected to all the I/O-modules with cable. The Master Generator supports the Radio Modem type 2ASxE and all 3AS types from the Finnish manufacturer SATEL (www.satel.fi). Find below an application diagram for the Radio Modem option. Note: Analink modules cannot be used with Radio Modems. On-board I/O The Master Generator has 4 digital inputs and 4 digital outputs on-board. These have been implemented to reduce the cost of remote stations with only a few signals (e.g. in connection with an SMS alarm system or radio modem remote stations). The onboard I/O's are used via the logic functions of the Master Generator, where they can be assigned to specific channel addresses. Radio Modem driver The Master Generator has a built-in driver for control of an external Radio Modem, which can be used to create wireless links where no cable is available in parts of an installation. One Master Generator must be defined as the central MGEN and up to 32 Master Generators can be defined as remote MGEN's. The central MGEN is Specifications are subject to change without notice (21.08.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 3 Du line G 3800 0015, G 3800 1015 (R) Fieldbus Pin Assignment, COM1, COM2 5 1 9 6 Pin Signal 2 3 5 TxD RxD Signal Ground Installationbus RS 232 Cable 9-pin male to controller 2 3 5 9-pin female to PC 2 3 5 9-pin male to controller 2 3 5 15-pin female to radio modem 11 9 7 Networking PC Interface #1 Dupline #1 Interface #2 Dupline #2 I/O modules * Digital * Analogue * Counter I/O modules * Digital * Analogue * Counter Modbus/RS485 Radio Modem Application Central MGEN RS232 Remote MGEN #1 RS232 Remote MGEN #2 RS232 ANT1 4 ANT2 Specifications are subject to change without notice (21.08.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group Du line G 3800 0015, G 3800 1015 (R) Fieldbus Dimensions (mm) H8-housing Installationbus Scope of Supply 1 x Master Channel Generator 1 x User manual 1 x RS 232 cable 1 x Configuration software G 3800 x015 xxx MAN G 3800 0015 ENG RS 232-9 M/9 F SW G 38xx15 Accessories Dupline Data Access Software DUPDATACC GSM Antenna 900 MHz ANT1 Antenna for Radio controlled clock ANT2 Specifications are subject to change without notice (21.08.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 5