Carbon Film Fixed Resistors
Type CFR Series
1773195 CIS WR 09/2011 Dimensions are in millimeters Dimensions are shown for For email, phone or live chat, go to: te.com/help
and inches unless otherwise reference purposes only.
specified. Values in brackets Specifications subject
are standard equivalents. to change.
The resistive element comprises a thin film of carbon, deposited onto a high thermal con-
ductivity ceramic core. Metal end caps are force fitted to the element prior to spiralling to
value. Tinned copper lead wires are welded to the end caps and the components are then
coated. One coat of phenolic resin is followed by three coats of epoxy resin. All resistors
are tested for value and tolerance.
Key Features
■
Low cost, combined with high
reliability, make these compo-
nents suitable for use in most
types of circuits, including
audio, communications,
measurement and computer
applications.
■
Premium quality carbon film
resistors whose ceramic core
has a high alumina content
offering power to size ratios
not normally associated with
carbon film product.
■
Available in 5 power ratings
from 1 ohm to 10 Mohm.
The smallest case size
(CFR16) has a full 0.25 W
power rating.
Characteristics -
Electrical
CFR16 CFR25 CFR50 CFR100 CFR200
Rated Power @ 70 °C (W) 0.25 0.33 0.5 12
Resistance Range (Ohms) Min 1R0 1R0 1R0 1R0 1R0
Max 4M7 10M 10M 10M 10M
Tolerance (%) 2 5
Code letter G J
Temp. Coefficient up to 10R ±350 ±350 ±350 ±350 ±350
(ppm/°C) 11R - 99K 0 to -450 0 to -450 0 to -450 0 to -450 0 to -450
100K - 1M0 0 to -700 0 to -700 0 to -700 0 to -700 0 to -700
1M1 - 10M 0 to -1500 0 to -1500 0 to -1500 0 to -1500 0 to -1500
Selection Series E24
Limiting Element Voltage (V) 200 250 350 500 500
Max Overload Voltage1(V) 400 500 700 1000 1000
Max Intermittent Overload Voltage2(V) 500 700 750 750 750
Operating Temp. Range (°C) -55 to +155
Climatic Category (°C) 55/155/56
Dielectric Strength (V) 400 500 700 1000 1000
Insulation Resistance (Mohms) 1000
1Maximum Overload Voltage is 2.5 times rated voltage up to the specified voltage for 5 seconds.
2Maximum Intermittent Overload Voltage is 4 times rated voltage up to the specified voltage for 1 second ON and 25 seconds OFF. >100R