www.aemc.com
Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS
Three-Phase Power Quality Analyzer
2GB of memory for trend data
storage and additional memory
for : up to 50 snapshots, 210
captured transients/inrush
and 10,000 alarm events
Special
product
features
2
G
B
M
E
M
O
R
Y
C
A
P
T
R
E
T
R
A
N
S
I
E
N
T
S
T
R
E
N
D
R
E
C
O
R
D
I
N
G
'
'
'
'
PRODUCT INCLUDES
Five black 10 ft voltage leads, five black alligator clips, twelve color-
coded input ID markers, USB cable, NiMH battery, 110/240V power
adapter with US power cord, large classic tool bag, soft carrying
pouch, quick start user guide, and USB stick supplied with product
user manual and DataView® software.
8336
Five voltage and four current input terminals
SPECIFICATIONS
MODEL 8336
Input Terminals 5 voltage / 4 current
Inputs 4 voltage / 4 current
Voltage (TRMS AC+DC) Phase-to-Phase: 0 to 2000
Phase-to-Neutral : 0 to 1000V
Voltage Ratio up to 500kV
Current (TRMS AC+DC) MN93: 500mA to 200Aac; MN193: 0.005 to 100Aac
SR193 Clamp: 1A to 1000Aac
AmpFlex® or MiniFlex® Clamps: 100mA to 10000Aac
MR193 Clamp: 1A to 1300Aac/dc
SL261 Clamp: 50mA to 100Aac/dc
Current Ratio: up to 60kV
J93: 50 to 3500Aac, 50 to 5000Adc
Frequency (Hz) 40 to 70Hz
Distribution Systems 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W, 3p
5W, Split-Phase 2W & 3W, 2 ½ Element & Aron meters
Power Values W, VA, var, VAD, PF, DPF, cos ϕ, tan ϕ
Energy Values Wh, varh, VAh, VADh
Harmonics 1st to 50th, Direction, Sequence; THD: 0 to 50, Phase
Transients up to 210
Trend Mode Records up to 41 variables as fast as once per second
for one month depending on selected storage rate
Flicker Pst & Plt
Inrush Mode Yes, >10 min
Unbalance Yes
Record Mode Yes
Alarm Mode 40 types; 10,000 recorded
Waveform Mode Calculated: AN (RMS, DC, CF, PK+/-) and FK
Peak Yes
Phasor Display Automatic
Data Stoage 2GB card for trend + 4MB partitioned
for snapshot, transients and alarms
Other Measurements 256 samples/cycle for trend recording
Display Color ¼ VGA TFT screen (320 x 240) diagonal 148mm
Snapshots 50
Sampling Frequency 256 samples/cycle for trend recording
Electrical Safety IEC 61010, 1000V CAT III / 600V CAT IV
Protection IP53 - Non Operating
Languages more than 26
Communication Interface USB
Battery Life 10 hrs in non - Record Mode with display on;
25 hrs in Record Mode with display off
Power Supply 9.6V NiMH rechargeable battery pack (included)
External AC supply: 110/230Vac ±10% (50/60Hz)
Dimensions / Weight 9.8 x 7.8 x 2.6" (240 x 180 x 55mm) / 4.3 lbs (1.95kg)
NEW!
3
3
W
A
R
R
A
N
T
Y
Y
E
A
R
*
* Registration must take place within 30 days of purchase
R
A
T
I
N
G
S
A
F
E
T
Y
IP
Rated
53
Non Operating
AmpFlex® 193
Flexible Current Probe (6500A)
Color-coded, 24", rated 600V CAT IV
OPTIONAL KITS
MN193
Current Probe (5A/100A)
Color-coded, rated 600V CAT III
PowerPad® III Model 8336
www.aemc.com
Technical Assistance (800) 343-1391
CATALOG NO. DESCRIPTION
2136.30 PowerPad® III Model 8336 (no probes)
2136.31 PowerPad® III Model 8336 w/4 193-24-BK Sensors
2136.32 PowerPad® III Model 8336 w/4 MN193-BK Probes
Accessories (Optional)
2133.73 Extra Large Classic Tool Bag
2140.15 Replacement – Soft Carrying Pouch
2140.17 5A Adapter Box (special order only)
2140.19 Replacement – Battery 9.6V NiMH
2140.28 AC Current Probe Model MR193-BK
2140.32 AC Current Probe Model MN93-BK
2140.33 AC Current Probe Model SR193-BK
2140.34 AmpFlex® Sensor 24" Model 193-24-BK
2140.35 AmpFlex® Sensor 36" Model 193-36-BK
2140.36 AC Current Probe Model MN193-BK
2140.43 Replacement – Set of 5, 10 ft (3m) black leads w/5 black alligator clips
2140.44 Lead, 1 10 ft (3m) black lead w/black alligator clip
2140.45 Replacement – Set of 12, Color-coded Input ID Markers
2140.46 Replacement – 5 ft USB Cable
2140.48 MiniFlex® Sensor 10" Model MA193-10-BK
2140.49 AC/DC Current Probe Model J93-BK
Power and Energy Mode Phasor Diagram
Recording Mode Harmonics Mode
Configuration Transient Mode
PowerPad® III Model 8336
Large Color Functional Displays
FEATURES
Measurement of TRMS voltages up to 1000Vrms
AC/DC for two-, three-, four- or five-wire systems
Measurement of TRMS currents up to 10,000Arms
(sensor dependent)
Direct measurement of neutral current & voltage
Frequency measurement (40 to 70Hz systems)
Record and display trend data as fast as once
per second for one month for up to 41 variables
Up to 210 transient detection on all V and I inputs
down to 65/sec
Selectable PT and CT ratios
Inrush current measurement
Calculation of Crest Factors for V and A
Calculation of the Factor K for transformers
Calculation of short-term and long-term flicker
Calculation of the Three-Phase voltage unbalance
Harmonic measurements (referenced to the
fundamental or RMS value) for voltage, current or
power, up to 50th harmonic
Displays of harmonic sequencing and
direction and calculation of overall harmonics
Real-time display of Phasor diagrams
including values and phase angles
Monitors the average value of any parameter,
calculated for a period from 1 sec to 2 hrs
Measurement of active, reactive and apparent power
per phase and their respective sum total
Calculation of power factor, displacement power
factor and tangent factor
Recording, time stamping and characterization of
disturbance (swells, sags and interruptions,
exceedence of power and harmonic thresholds)
2GB internal, simultaneous Trend Recording memory;
Alarm, Photo and Transient Inrush memories are separate
Measurement of energy VAh, varh, Wh & VADh
The Max and Min RMS measurements are
calculated every half-period
Includes FREE DataView® software for configuring data
storage, real-time display, analysis and report generation
65μs/sample trend recording
POWER QUALITY ANALYZERS, METERS & LOGGERS
Three-Phase Power Quality Analyzer