NPC-1210SeriesSpecications
Medium Pressure Sensors
Pressure Ranges
•Gaugeanddifferential:
•5psi(34kPa,0.34bar)
•15psi(100kPa,1.0bar)
•30psi(210kPa,2.1bar)
•50psi(340kPa,3.4bar)
•100psi(690kPa,6.9bar)
•Absolute:
•15psi(100kPa,1.0bar)
•30psi(210kPa,2.1bar)
•50psi(340kPa,3.4bar)
•100psi(690kPa,6.9bar)
•Forotherpressureranges,pleasecontactNovaSensor.
Parameter Value Units Notes
Environmental
Temperature Range
Operating –40 to 125 °C (-40° to 257°F)
Compensated 0 to 60 °C (32°F to 140°F)
Storage –55 to 150 °C (–67 to 302 °F)
Mechanical
Weight 2.5 g (0.005
lb)
Media
Compatibility
Compatible with
exposedmaterials
7
Positive
differential and
gauge ports
Dry gases
only
Absolute.
negative
differential ports
Dry gases
only
Parameter Units Minimum Typical Maximum Notes
Performance Parameters *
FS Output (FSO) mV 75 100 150 2,3
Zero Pressure
Output
mV -2 — 2 3
Linearity %FSO -0.1 — 0.1 4,8
Pressure
Hysteresis
%FSO -0.1 — 0.1
Input
Impedance
W 2500 4000 6000
Output
Impedance
W 4000 5000 6000
Thermal
Accuracy–Span
%FSO -0.5 — 0.5 3,5,8
Thermal
Accuracy–Zero
%FSO -0.5 — 0.5 3,5,8
Temperature
Coefcient–
Resistance
%/°C — 0.2 — 5
Thermal
Hysteresis–Zero
%FSO — 0.1 — 5
InputExcitation mA — 1.5 2.0
Pressure
Overload
Rated — — 3X 6
* 1. Supply current = 1.5 mA and ambient temperature = 77°F (25°C),
unless otherwise noted. Gauge and differential pressure devices are calibrated
by applying pressure to the positive differential port (P2) and venting to
atmosphere the reference port (P1).
2. Output span of unamplified sensor.
3. Compensation resistors are an integral part of the sensor package;
no additional external resistors are required. Pins 7 and 8 must be kept open.
The NPC-1210 is interchangeable only when used with the gain set resistor
shown in the schematic diagram. Maximum gain-set resistor mismatch is 2%.
4. Best fit straight line.
5. Temperature range 32°F to 140°F (0°C to 60°C), reference to 77°F (25°C).
6. 3X or 200 psi (13.78 bar) maximum, whichever is less.
7. Exposed materials are pyrex, ceramic, silicon, epoxy, RTV, and stainless steel.
8. 5 psi (0.34 bar) spec.: Linearity: 0.25 ±%FSO, TC-span:
0.75 ±%FSO, TC-zero: 0.75 ±%FSO. otherwise noted.
Low Pressure Sensors
Pressure Ranges
• Gaugeanddifferential:
• 10 in H20(2.5kPa,0.025bar)
•1psi(6.9kPa,0.069bar)
Parameter Value Units Notes
Environmental
Temperature Range
Operating –40 to 125 °C (-40° to 257°F)
Compensated 0 to 60 °C (32°F to 140°F)
Storage –55 to 150 °C (–67 to 302 °F)
Mechanical
Weight 2.5 g (0.005
lb)
Media
Compatibility
Compatible with
exposedmaterials
7
Positive
differential and
gauge ports
Dry gases
only
Absolute.
negative
differential ports
Dry gases
only
Parameter Units Minimum Typical Maximum Notes
Performance Parameters *
FSO 10 inH2O mV 25 50 70 2,3
FSO 1 psi mV 50 75 110 2,3
Zero Pressure
Output
mV -2 — 2 3
Linearity %FSO -0.5 — 0.5 4
Pressure
Hysteresis
%FSO -0.1 — 0.1
Input
Impedance
W 2500 4000 6000
Output
Impedance
W 4000 5000 6000
Thermal
Accuracy–Span
%FSO -1.0 — 1.0 3,5
Thermal
Accuracy–Zero
%FSO -1.25 — 1.25 3,5
Temperature
Coefcient–
Resistance
%/°C — 0.22 — 5
Thermal
Hysteresis–Zero
%FSO — 0.1 — 5
InputExcitation mA — 1.5 2.0
Pressure
Overload
psi (bar) 5 (0.34) — — 6