6
D4C
Specifications
Approved Standards
Ratings
Standard Model
Pre-wired Model
Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
UL/CSA
B300 (D4C-16@@, -17@@)
B150 (D4C-26@@, -27@@)
B300
B150
Characteristics
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C,
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching
current: 0.1 A)
*3. Outdoor specifications: 500,000 operations min.
*4. Excluding Plastic Rods.
*5. Pre-wired models: 250 V
*6. Pre-wired models: class III
Agency Standard File No.
TÜV Product
Service EN60947-5-1 *1, 3
UL UL508 E76675 *2
CSA CSA C22.2 No.14 LR45746 *2
CCC(CQC) GB14048.5 2003010305077626 *3
*1. Models with VCTF oil-resistant cables and pre-wired models only.
(Applicable only to standard models listed on pages 2 to 4.)
*2. SJT(O)-cable models only.
(Applicable only to standard models listed on pages 2 to 3.)
*3. Ask your OMRON representative for information on approved models.
Rated voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (0.1)
5
1.5
1
0.7
0.5
3
2
2.5
1.5
1.3
0.8
8 VDC 5 (0.1) 2 5 4 3
14 VDC 5 (0.1) 2 4 4 3
30 VDC 4 (0.1) 2 3 3 3
125 VDC 0.4 0.05 0.4 0.05
250 VDC 0.2 0.03 0.2 0.03
Inrush
current
NC 20 A max.
NO 10 A max.
Note: 1. The values given on the left are steady-state
currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times
the steady-state current.
4. Motor loads have an inrush current of 6 times
the steady-state current.
5. The values "0.1" given in parentheses are for
micro load models.
Rated voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC1110.71111
30 VDC 11111111
Model Applicable category and
ratings I the
D4C-1@@@ AC-15 2 A/250 V
DC-12 2 A/30 V
5 A
4 A
D4C-2@@@ AC-15 2 A/125 V 5 A
D4C-3@@@ DC-12 2 A/30 V 4 A
D4C-4@@@ AC-14 0.1 A/125 V
DC-12 0.1 A/30 V
0.5 A
0.5 A
D4C-5@@@ AC-14 0.1 A/125 V 0.5 A
D4C-6@@@ DC-12 0.1 A/30 V 0.5 A
Rated voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC 5 A 30
15
3
1.5
3,600
3,600
360
360
Rated voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
120 VAC 5 A 30 3 3,600 360
Degree of protection IP67
Durability
*1
Mechanical *3 10,000,000 operations min.
Electrical *2
200,000 operations min. (5 A at 125 VAC, resistive load)
Operating speed 0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
Operating
frequency
Mechanical 120 operations/min
Electrical 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial)
250 m
Ω
max. (initial value with 2-m VCTF cable)
300 m
Ω
max. (initial value with 3-m VCTF cable)
400 m
Ω
max. (initial value with 5-m VCTF cable)
Dielectric
strength
Between terminals of
the same polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-
carrying metal
part and ground
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV (EN60947-5-1)
Between each terminal
and non-current-carry-
ing metal part,
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1)
Rated insulation voltage (Ui)
300 V (EN60947-5-1) *5
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gI or gG (IEC60269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed
thermal current (I the) 5 A, 4 A, 0.5 A (EN60947-5-1)
Protection against electric shock
Class I (with grounding wire) *6
Vibration re-
sistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *4
Shock re-
sistance
Destruction 1,000 m/s2 min.
Malfunction 500 m/s2 min. *4
Ambient operating temperature
−10°C to +70°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight (D4C-1202) With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g