ELECTRICAL SPECIFICATIONS
Output Signal: Supply Voltage:
4-20mA (2 wire) 10-36 Vdc
1-5 Vdc (3 wire) 10-36 Vdc
1-6 Vdc (3 wire) 10-36 Vdc
2mV/V ratiometric 5-10 Vdc regulated
3mV/V ratiometric 5-10 Vdc regulated
10mV/V ratiometric 5-10 Vdc regulated
20mV/V ratiometric 5-10 Vdc regulated
Reverse polarity protected
Supply Current: Less than 3mA for voltage
output
Circuit to Case Insulation Resistance:
100 M ohms @ 50 Vdc
PHYSICAL SPECIFICATIONS
Standard Process Connections:
(316L stainless steel)
Tri-Clamp®style 11⁄2,˝ 2˝.
Enclosure: NEMA 4X, (NEMA 1 only if <500
psig and electrical termination is Bendix®or
Hirschmann®).
Case: 300 series stainless steel
Cable: No. 24 AWG, 36˝ PVC, shielded,
vented, UL approved.
Diaphragm: 316L stainless steel electro-
polished
Fill: USP grade 99.5% glycerin fill, contact
factory for other fill fluids.
W eight: 13.5 oz. (approx. without cable)
Consult factory for pricing, availability and
required minimums for non-standard
products.
WARNING! Sensitive diaphragm! Do not
touch! Remove protective-cap just before
installation!
Bendix®is registered trademark of Amphenol Corp.
Hirschmann®is registered trademark of Richard Hirschmann
of America Inc.
Tri-Clamp®is a registered trademark of Tri-Clover, Inc.
PERFORMANCE CHARACTERISTICS
Accuracy Class (F.S.): 1.0%
Nonlinearity
Terminal Point* ± 0.7%
B.F.S.L. ±0.4%
Hysteresis ±0.2%
Nonrepeatability ±0.07%
*Including hysteresis
Standard Ranges (psi):
0/30*† 0/300† Vac/30†
0/60*† 0/500 Vac/60†
0/100† 0/750 Vac/100†
0/150† 0/1000
0/200†
Consult factory for non-standard ranges.
*T/C multiply by 1.5 times
†NEMA 4X only with F2 and C1 electrical connections.
Stability: ±1% F.S./year
Durability: 107cycles 20/80% F.S. with
negligible performance change
Response Time: Less than 5m sec.
ENVIRONMENTAL SPECIFICATIONS
Temperature Limits:
Storage –65/+250°F
Operating –20/+180°F
Compensated +30/+130°F
Thermal Coefficients (68°F ref.):
Zero ± 0.04% F.S./°F
Span ±0.04% F.S./°F
Humidity: No performance effect at 95%
relative humidity-noncondensing
FUNCTIONAL SPECIFICATIONS
Overpressure (F.S.):
Proof 200%
Burst 800%
Vibration Sweep:
Less than ± 0.1% F.S. effect for 0-2000 Hz at
20 g's in any axis
Shock: Less than ±0.05% F.S. effect for
100 g's, 20 ms shock in any axis
Position Effect: Less than 0.1% F.S.
Model KS Pressure Transducer/Transmitter
Dimensions
Vmin = 10V+ (.022A x RL)
RL= RS+ RW
RL= Loop Resistance (ohms)
RS= Sense Resistance (ohms)
RW= Wire Resistance (ohms)
D
A
▼
▲
▲
C
▼
▲
▲
▲
B
MODEL ABCD
S15 0.8 4.7 0.9 2.0
S20 0.8 4.7 0.9 2.5
▲
1000
750
500
250
0
0362010
1182
30
Load Limitations 4-20mA Output Only
(R
LOOP )
38 WELLINGTON ROAD
MILFORD, CT. 06460
(203) 783-6650 Customer Service
(203) 783-6659 FAX
www.dresser.com/instruments
All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Dresser Instrument Division 11/97 20MCP 1P 1/94 6P 11/97
How To Order KS #
7
Type Configuration
(KS) Sanitary Seal
(S15) 11⁄2˝ Sanitary Connection
(S20) 2˝ Sanitary Connection
Electrical Termination
(F2) 36˝ Cable, Shielded, PVC Sheathing
(B6) Bendix 6-pin #PTO2A-10-6P*
(B9) WP Bendix 6-pin #PTO2H-10-6P*
(B4) Bendix 4-pin #PTO2A-8-4P*
(B8) WP Bendix 4-pin #PTO2H-8-4P*
(C1) 1⁄2NPT-M Conduit and 36˝ Cable
(HM) Hirschmann Miniature
Accuracy
(7) 1.0%, ±0.040%/°F Output Signal
(42) 4-20mA
(16) 1-6 Vdc
(15) 1-5 Vdc
(02) 2mV/V
(03) 3mV/V
(10) 10mV/V
(20) 20mV/V
Pressure Range
(30) 30 psi
(60) 60 psi
(100) 100 psi
(150) 150 psi
(200) 200 psi
(300) 300 psi
(500) 500 psi
(750) 750 psi
(1000) 1000 psi
(Vac/30) Vac/30
(Vac/60) Vac/60
(Vac/100) Vac/100
*Mating connector available as option