3
SY88802
Micrel
Absolute Maximum Ratings(Note 1)
Power Supply Voltage (VCC)............................ 0V to +7.0V
Input Voltage (VIN) .............................................. 0V to VCC
Output Current (IOUT).................................................25mA
Power Dissipation (PTOT)........................................250mW
Storage Temperature Range (TS)............–55°C to +125°C
Operating Ratings(Notes 2, 3, 4)
Supply Voltage (VCC) .................................. +4.5V to +5.5V
Ambient Temperature (TA), Note 5............ –40°C to +85°C
Junction Temperature (TJ), Note 5 ............ –40°C to 100°C
Resistor to Dissipate Power (REXT) ..................10Ω to 50Ω
Laser Diode Serial Resistor (RSER) ....................0Ω to 50Ω
Resistor to Adjust Current (RSET) ..........1500Ω to 50,000Ω
Package Thermal Resistance
MSOP
(θJA) Still-Air ......................................................113°C/W
(ψJB) Still-Air........................................................74°C/W
GND = 0V; VCC = 5V ±10%; TA = –40°C to +85°C
Symbol Parameter Condition Min Typ Max Units
VIH Input HIGH Voltage VCC–1.165 VCC–0.880 V
(DIN, /DIN, /EN)
VIL Input LOW Voltage VCC–1.810 VCC–1.475 V
(DIN, /DIN, /EN)
VREF Reference Voltage 3.00 V
IIL Input LOW Current VIN = VIL(min) 0.5 µA
(DIN, /DIN, /EN)
IIH Input HIGH Current 100 µA
(DIN, /DIN, /EN)
ICC Supply Current IMOD = 25mA 16 25 mA
IOUT_OFF Output LOW Current 500 µA
(/EN = HIGH)
IOUT Modulation Current 5 15 25 mA
ARSET IOUT/IRSET 30 38 44 —
VOUT Voltage at OUT, /OUT VCC–2.3 VCC V
COUT Capacitance on OUT, /OUT 2.5 pF
Note 1. Specification for packaged product only.
DC ELECTRICAL CHARACTERISTICS(Note 1)
Note 1. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. This is a stress rating only and functional operation
is not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to ABSOLUTE MAXIMUM
RATlNG conditions for extended periods may affect device reliability.
Note 2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
Note 3. The device is guaranteed to meet the DC specifications, shown in the table above, after thermal equilibrium has been established. The device
is tested in a socket such that transverse airflow of ≥500lfpm is maintained.
Note 4. The voltage drop across REXT and RSER plus Laser Diode must not be greater than 2.3V.