1
Termination Insensitive Mixer,
5 MHz - 1500 MHz
Rev. V5
MD- / MDC- / MDS-158
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
FP-2 (MD-158)
C-7 (MDC-158)
SF-1 (MDS-158)
Features
Low VSWR
Conversion Loss: 6 dB Typical Midband
LO-RF Isolation: 35 dB Typical Midband
Conversion Loss Flatness: 1.5 dB Typical
Impedance: 50 Ohms Nominal
Maximum Input Power: 300 mW max. @ 25°C,
Derated linearly to 85°C @ 3.2 mW/°C
IF Port Current: 50 mA Max.
MIL-STD-883 Screening Available
Description
Transformers convert the LO and RF paths to
balanced lines connecting to a low barrier, Schottky
diode ring quad. These transformers help provide
excellent isolation between ports. Conversion Loss
is low. The direct connection of the IF port to the
diode quad allows these mixers to be used as phase
detectors and bi-phase modulators. Advanced
transformer design yields improved VSWR.
2
Termination Insensitive Mixer,
5 MHz - 1500 MHz
Rev. V5
MD- / MDC- / MDS-158
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Electrical Specifications1: TA = -55°C to +85°C
1. All specifications apply when operated at +7 dBm available LO power with 50 Ohm source and load impedance.
2. For MDC-158 add 1.0 dB to conversion loss.
Pin Configuration (MD-158)
Pin No. Function Pin No. Function
1 GND 5 LO
2 GND 6 GND
3 GND 7 GND
4 IF 8 RF
Absolute Maximum Ratings (MDS-158) 4
Parameter Absolute Maximum
Max Input Power5 300mW
Total Power 350 mW Derated at 85oC @ 3.2
mW/oC
LO Power +24 dBm
4. Operation of this device above any one of these parameters
may cause permanent damage.
5. Ambient Temperature (TA) = +25oC
Pin Configuration (MDS-158)
Pin No. Function Pin No. Function
1 GND 3 LO
2 IF 4 RF
Parameter Test Conditions Frequency Units Min Typ Max
Frequency Range RF, LO Ports
IF Port
5 - 1500
DC - 1000
MHz
MHz
Conversion Loss 5 - 1000 MHz
5 - 1300 MHz
5 - 1500MHz
dB
dB
dB
7.0
9.0
10.0
Isolation LO to RF
5 1500 MHz
5 - 1000 MHz
5 - 600 MHz
dB
dB
dB
20
25
30
LO to IF 5 1500 MHz
5 - 1000 MHz
dB
dB
17
20
RF to IF 5 1500 MHz
5 - 1000 MHz
5 - 600 MHz
dB
dB
dB
8
18
20
DC Polarity Negative
DC Offset mV <1
RF Input 1 dB Compression
1 dB Desensitization
dBm
dBm
+1
-1
SSB Noise Figure Within 1 dB of Conversion Loss
Max.
Typical Two Tone IM
Ratio
With 10 dBm input, each input 60
MHz and 70 MHz IF
300 MHz
1000 MHz
dB
dB
50
48
3
Termination Insensitive Mixer,
5 MHz - 1500 MHz
Rev. V5
MD- / MDC- / MDS-158
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Bottom View of SF-1
Typical Performance Curves
4
Termination Insensitive Mixer,
5 MHz - 1500 MHz
Rev. V5
MD- / MDC- / MDS-158
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.