AC/DC Power Modules TML Series, 20& 40 Watt CB Scheme Features Encapsulated power supplies with LVD UL 60950-1 increased power density Replaces TML 15 and TML 30 series PCB mount or chassis mount with screw terminals Single, dual and triple output models Universal input 90-264 VAC, 47-440 Hz EMI meets EN 55022, class B and FCC, level B Protection class ll for TML 40 models Short circuit and overload protection 3-year product warranty Also see: TMLM Series, 4 to 20 Watt highest power density, PCB mount. www.tracopower.com/products/tmlm.pdf Referance datasheet for primary TML models, see: www.tracopower.com/products/tml-primary.pdf (not recommended for new design in) The TML series are ultra compact AC/DC power supplies in a fully encapsulated plastic case. They feature versions with screw terminals for easy installation or with solder pins for direct PCB mounting. International safety approvals qualify this product for worldwide markets. The TML series AC/DC modules offer an interesting solution for many space critical applications in commercial and industrial electronic equipment. 20 Watt Models Order code Output power max. Output 1 14.9 W 3.3 VDC/4500 mA Output 2 Output 3 PCB mount Chassis mount TML 20103 TML 20103C TML 20105 TML 20105C 5.0 VDC/4000 mA TML 20112 TML 20112C 12 VDC/1670 mA TML 20115 TML 20115C 15 VDC/1340 mA TML 20124 TML 20124C TML 20205 TML 20205C +5.0 VDC/2000 mA -5.0 VDC/2000 mA TML 20212 TML 20212C +12 VDC/833 mA -12 VDC/833 mA TML 20215 TML 20215C +15 VDC/667 mA -15 VDC/667 mA TML 20512 TML 20512C *5 VDC/2800 mA +12 VDC/250 mA -12 VDC/250 mA TML 20515 TML 20515C *5 VDC/2800 mA +15 VDC/200 mA -15 VDC/200 mA 20 W 24 VDC/840 mA * Output floating www.tracopower.com Page 1 of 5 AC/DC Power Modules TML Series 20 & 40 Watt 40 Watt Models Order code Output power max. Output 1 26.4 W 3.3 VDC/8000 mA Output 2 Output 3 PCB mount Chassis mount TML 40103 TML 40103C TML 40105 TML 40105C 5.0 VDC/8000 mA TML 40112 TML 40112C 12 VDC/3333 mA TML 40115 TML 40115C 15 VDC/2666 mA TML 40124 TML 40124C 24 VDC/1667 mA TML 40205 TML 40205C TML 40212 TML 40212C TML 40215 TML 40215C +15 VDC/1333 mA -15 VDC/1333 mA TML 40252 TML 40252C *5.0 VDC/5000 mA *12 VDC/1250 mA TML 40254 TML 40254C *5.0 VDC/5000 mA *24 VDC/625 mA TML 40512 TML 40512C *5.0 VDC/5000 mA +12 VDC/600 mA -12 VDC/600 mA TML 40515 TML 40515C *5.0 VDC/5000 mA +15 VDC/500 mA -15 VDC/500 mA 40 W +5.0 VDC/4000 mA -5.0 VDC/4000 mA +12 VDC/1666 mA -12 VDC/1666 mA * Output floating Input Specifications Input voltage ranges - AC input 90 - 264 VAC - DC Input 100 - 375 VDC Input frequency 47 - 440 Hz Input current at full load (115 VAC / 230 VAC nominal input) TML 20 models: 400 mA / 270 mA max. TML 40 models: 860 mA / 460 mA max. Leakage current 0.25 mA max. External fuse (required) TML 20 models: 2.0 A slow blow type (recommendation) TML 40 models: 1.5 A slow blow type (recommendation) Output Specifications Voltage set accuracy TML 20 models: TML 40103 model: TML 40 single and symetric dual output models: TML 40 asymetric dual and triple output models: 2 % 3 % 2 % 3 % for output 1, 5 % for output 2&3 Minimum load TML 20 single and dual output models: 0 % TML 20 triple output models: 10 % (each output) TML 40 single output models: 1 % TML 40 symetric dual output models: 10 % (each output) TML 40 asymetric dual and triple output models: 25 % (each output) operation at lower load condition will not damage these power supplies, however, they may not meet all listed specifications. Ripple and noise (20 MHz bandwidth) TML 20 models: <0.7 % of Vout + 90 mV [Vp-p] TML 40103 model: <50 mVp-p TML 40 other models: <1 % of Vout [Vp-p] Regulation - Input variation single and symetric dual output models: 0.5 % (each output) TML 20 triple output models: 1 % for output 1, 5 % for output 2&3 TML 40 asymetric dual and triple output models: 0.5 % for output 1, 5 % for output 2&3 All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 5 AC/DC Power Modules TML Series 20 & 40 Watt Output Specifications Regulation - Load variation TML 20 single output models: TML 20 dual output models: TML 20 triple output models: TML 40 single output models: TML 40 symmetric dual output models: TML 40 asymmetric dual output models: TML 40 triple output models: 1 %, 0-100 % load 3 % (each output), 10-100 % symmetric load 2 % for output 1, 20-100 % load 5 % for output 2&3, 20-100 % symmetric load 0.5 % 1-100 % load 1 % (each output), 10-100 % symmetric load 2 % for output 1, 25-100 % load 6 % for output 2, 25-100 % load 3 % for output 1, 25-100 % load 7 % for output 2&3, 25-100 % symmetric load Current limitation above 105 % of rated output current Overvoltage protection (main output only) by Zener diode Short circuit protection hiccup mode, indefinite (automatic recovery) Overtemperature protection (TML 40 models only) at +100C Max. capacitive load Model series Output: Single output models Dual output models symetric Dual output models asymetric Triple output models TML 20 TML 40 3.3 VDC 25`000 F 60`000 F 5.0 VDC 13`000 F 40`000 F 12 VDC 920 F 8`600 F 15 VDC 820 F 6`600 F 24 VDC 600 F 1`400 F +5.0 / -5.0 VDC 4`300 / 4`300 F 12`000 / 12`000 F +12 / -12 VDC 560 /560 F 4`400 / 4`400 F +15 / -15 VDC 220 /220 F 1`000 / 1`000 F +5.0 / +12 VDC - 10`000 / 470 F +5.0 / +24 VDC - 10`000 / 400 F +5.0 / +12 / -12 VDC 3`500 / 220 / 220 F 10`000 / 780 / 780 F +5.0 / +15 / -15VDC 3`500 / 150 / 150 F 10`000 / 900 / 900 F General Specifications Temperature ranges - Operating TML 20 models: TML 40 models: - Power derating above +50C TML 20 models: TML 40 models: - Case max. - Storage (non operating) Temperature coefficient -25C to +70C -40C to +60C 3.75 %/K 3.0 %/K +95C -40C to +85C TML 20 models: 0.02 %/K TML 40 models: 0.01 %/K Efficiency 74 - 84 % (depending on model) Humidity (non condensing) 95 % rel max. Switching frequency (pulse width modulation PWM) TML 20 models: 100 kHz typ. TML 40 models: 132 kHz typ. Hold-up time 10 ms min. Isolation voltage - Input/Output 3`000 VAC Reliability /calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) >200'000 h EMI / RFI conducted EN 55022, class B, FCC part 15, level B EMC compliance EN 55024 All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 5 AC/DC Power Modules TML Series 20 & 40 Watt General Specifications Protection class class II to IEC/EN 60536 Safety standards UL/cUL 60950-1, IEC/EN 60950-1 - Certification documents www.tracopower.com/overview/tml Casing material plastic resin + fiberglass (UL 94V-0 rated) Environmental compliance - Reach www.tracopower.com/products/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Outline Dimensions 11.5 (0.45) 5 1 3.75 4 23.75 (0.94) 11.5 6 8.5 (0.79) Bottom view (0.33) 20.0 (0.79) 7 2 20.0 47.5 (1.87) 8.5 8 (0.45) 3 (0.33) TML 20 models for PCB mount: 62.0 (2.44) 21.7 (0.85) 8.0 (0.31) (0.15) 69.5 (2.74) Pin diameter o 1.0 mm (0.039) Weight: 110 g (3.9 oz) Pinout / Connection 4 x o3.5 (0.16) 6.0 (0.23) Pin/ con. 4.0 27.6 (1.09) TML 20C models for chassis mount: (4 x o0.14) 54.6 (2.15) 46.0 (1.81) 4 1 2 5 Top view Single output Dual output 1 FG 2 AC in (N) 3 AC in (L) Triple output 4 no pin / nc no pin / nc Vout 3 5 -Vout 1 Vout 2 com. 2/3 6 no pin com. 1/2 Vout 2 7 +Vout 1 +Vout 1 -Vout 1 8 no pin no pin nc = not to connect +Vout 1 6 7 3 8 5.0 86.0 (3.38) (0.20) 96.0 (3.78) Weight: 155 g (5.5 oz) www.tracopower.com Dimensions in[mm], () = Inches Tolerances = 0.5mm (0.02) Page 4 of 5 AC/DC Power Modules TML Series 20 & 40 Watt Outline Dimensions TML 40 models for PCB mount: (0.60) 8 15.24 3 12.7 (0.50) 5 2 4.1 32.05 (1.26) 12.7 (0.50) 6 (0.60) Bottom view 15.24 55.88 (2.20) 64.1 (2.52) 7 4 81.3 (3.20) 25.0 (0.98) 6.0 (0.24) (0.16) 89.5 (3.52) Pin diameter o 1.2 mm (0.047) Weight : 280 g (9.9 oz) TML 40C models for chassis mount: 6.5 Pin/ con. (0.25) 32.5 (1.28) Pinout / Connection 4 x o3.5 6.85 (0.23) 4 50.0 (1.97) Dual sym. output 1 (4 x o0.14) 63.7 (2.50) Single output 1 2 3 Triple output no pin / nc 2 AC in (L) 3 AC in (N) 4 +Vout 1 Vout 1 +Vout 2 Vout 2 5 no pin / nc no pin / nc +Vout 1 +Vout 1 6 -Vout 1 com. 1/2 -Vout 2 com. 2/3 7 no pin / nc no pin / nc -Vout 1 -Vout 1 8 nc Vout 2 no pin / nc Vout 3 5 Top view Dual asym. output 6 nc = not to connect 7 8 6.0 100.0 (3.94) (0.24) 112.0 (4.41) Dimensions in[mm], () = Inches Tolerances = 0.5mm (0.02) Weight : 325 g (11.5 oz) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. May 16, 2019 Page 5 of 5