Nominal capacity @ 1 mA, to 2V 1.1 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 50 mA
Maximum pulse current capability 100 mA
Weight 9.6 g (0.339 oz)
Volume 4 cc
Operating temperature range -55 ºC to +85 ºC
Li metal content approx. 0.35 g
U.L. Component Recognition, MH 12193
SUFFIX- /S STANDARD 15-5902-21530
SUFFIX- /T SOLDER TABS 15-5902-31530
SUFFIX- /P AXIAL PINS 15-5902-41530
SUFFIX- /PT2 RADIAL PINS 15-5902-36530
SUFFIX- /TP POLARIZED TABS 15-5902-52530
SUFFIX- /PT POLARIZED TABS 15-5902-53530
TECHNICAL DATA
(Typical values @+25 ºC for batteries stored for one year or less)
International size reference: 1/2AA, ER14252
MODEL TLL-5902
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
TERMINATIONS & ORDERING NO.
iXtra - Long Term High Performance
ECN 1501879 Rev. D 11/08
Page 1 of 2
DISCHARGE CHARACTERISTICS @ +25ºC
220
~14 mA
(0.80 Ah)
470
~7 mA
(0.97 Ah)
3.6 k
~1 mA
(1.10 Ah)
27 k
~0.125 mA
(1.08 Ah)
40 k
~40 µA
(1.02 Ah)
220 k
~17 µA
(0.92 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
VOLTAGE VS. TEMPERATURE
14 mA
7 mA
2 mA
0.8 mA
17 µA
4 µA
2.5
2.7
2.9
3.1
3.3
3.5
3.7
-50-30-101030507090
ºC
Volts CAPACITY VS. CURRENT
-30 °C
25 °C
55 °C
72 °C
1010.10.01
0.2
0.4
0.6
0.8
1.0
1.2
mA
Ah
VOLTAGE RESPONSE
After 1 year
After 2 years
After 4 years
After 7 years
3.1
3.2
3.3
3.4
3.5
0 20 40 60 80 100 120
msec
Volts
VOLTAGE RESPONSE
After 1 year
After 5 years
After 10 years
3.1
3.2
3.3
3.4
3.5
0 20 40 60 80 100 120
msec
Volts
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
High and stable operating voltage
Low self discharge rate
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
CELL FEATURES
TLL-5902
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
iXtra - Long Term High Performance
ECN 1501879 Rev. D 11/08
Page 2 of 2
MAIN APPLICATIONS
Utility meters (elect., water &
gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power
(
ULP
)
Cells should be stored in a
clean & dry (less than 30 %
RH) area
STORAGE CONDITIONS
For updated information please visit
our website www.tadiranbat.com
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 10 µA
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 5 µA
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 10 years
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
0 200 400 600 800 1000 1200
msec
Volts
Pulse applied: 10 mA for 1 sec
Storage: RT
Background current: None