SIZE CAGE CODE DWG NO.
037Z3 87093
DEFENSE SUPPLY CENTER, COLUMBUS
COLUMBUS, OH 43216-5000 AREV APAGE 7
ENGINEERING DATA:
Temperature rating: -65°C to +260°C.
REQUIREMENTS:
Dimensions and configurations: See figures 1 through 5.
Insulation resistance: Not applicable.
Corrosion (salt Spray): Method 101, test condition B, MIL-STD-202. The salt solution concentration shall be 5
percent.
Special detail: After exposure, hardware shall be washed, shaken, and lightly brushed, as specified in method 101
of MIL-STD-202, and then permitted to dry for 24 hours at 40°C. Hardware shall then be examined for evidence of
corrosion and pitting and ease of coupling.
Part or Identifying Number (PIN): See table I.
Approved sources of supply. Approved sources of supply are listed herein. Additional sources will be added as they
become available. The vendors listed on the requirements drawing have agreed to this drawing and a certificate of
compliance has been submitted to DSCC-VAI.