General Purpose High Power PCB Relays Potter & Brumfield T90 Series, 30A PCB Relay n n n n 30A, 1 form A (NO); 20A, 1 form C (CO) Available as open frame or sealed construction Meets UL 508 and 873 Spacing - 3.18 through air, 6.36 over surface UL class F insulation system standard Typical applications HVAC, Appliances, Industrial Controls. Coil Data Approvals Coil voltage range Max. coil power Max. coil temperature Coil insulation system according UL UL E22575; CSA LR15734 Technical data of approved types on request. Contact Data Contact arrangement 1 form A (NO), 1 form B (NC), 1 form C (CO) Rated voltage 277VAC Max. switching voltage 277VAC Rated current 30A Limiting continuous current 30A Limiting making current 30A Limiting breaking current 30A Contact material AgCdO Min. recommended contact load 1A, 5VDC or 12VAC Initial contact resistance 75 m at 1A at 5VDC or 12VAC Frequency of operation, with load 360hr Operate/release time max., including bounce 15/15ms 02-2014, Rev. 0214 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Coil resistance 10% 27 40 97 155 380 660 2560 13450 Rated coil power wW 900 900 900 900 900 900 900 900 All figures are given for coil without preenergization, at ambient temperature +23C. 100x103 100x103 100x103 100x103 100x10 100x103 100x103 100x103 100x103 100x103 30x103 30x103 100x103 100x103 1x103 1x103 1x103 1x103 100x103 6x103 6x103 6x103 100x103 100x103 3 10x106 ops. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Ambient temperature vs. coil voltage - 1W coil Coil Temp. Rise Above Ambient (C) Cycles All ratings at 25C (unless otherwise noted) with relay properly vented. Remove vent nib from enclosed relays after soldering and cleaning for optimum life. Mechanical endurance Coil versions, DC coil Coil Rated Operate Release code voltage voltage voltage VDC VDC VDC 5 5 3.75 0.5 6 6 4.5 0.6 9 9 6.75 0.9 12 12 9 1.2 18 18 13.5 1.8 24 24 18 2.4 48 48 36 4.8 110 110 82.5 11 130 Open Style Relay, No Dust Cover 120 110 100 90 80 70 60 30A Load 50 25A Load 40 20A Load 15A Load 10A Load 0A Load 30 20 50 75 100 125 150 175 200 225 125 150 175 200 225 Applied Continuous Coil Voltage (% of Rated Voltage) 150 Coil Temp. Rise Above Ambient (C) Contact ratings Type Load Typical AgCdO, open style relay NO 30A, 240VAC, general purpose NO 20A, 240VAC, resistive heater CO 20A/10A, 240VAC, general purpose CO 20A/10A, 28VDC, resistive UL 508/873 AgCdO NO 30A, 240VAC, general purpose NC 15A, 240VAC, general purpose CO 20A/10A, 240VAC, general purpose NO 20A, 240VAC, resistive NC 15A, 240VAC, resistive CO 20A/10A, 240VAC, resistive NO 80LRA/30FLA, 240VAC NC 30LRA/10FLA, 240VAC CO 53.6LRA/20FLA / 20LRA/6.7FLA, 240VAC NO 98LRA/22FLA, 120VAC NO 2HP, 240VAC NC 1/2HP, 240VAC NO 1HP, 120VAC NC 1/4HP, 120VAC NO 6A, 277VAC, ballast NC 3A, 277VAC, ballast NO TV5, 240VAC, tungsten NC TV3, 240VAC, tungsten NO 20A, 28VDC, resistive NC 10A, 28VDC, resistive 5 to 110VDC 1.0W 155C Class F Wash Tight Relay, Vented 140 130 120 110 100 90 80 70 60 50 40 30 30A Load 25A Load 20A Load 15A Load 10A Load 0A Load 20 50 75 100 Applied Continuous Coil Voltage (% of Rated Voltage) Data graphed above are average values and should be verified in application. Tests were conducted within a 2' (.6m) cube (still air); at nominal coil power @ 25C; with normally open contact loaded; and with 4' (1.22m) long, #10AWG load wires. P.C. board relays were mounted to a 30A, single side P.C. board. Coil rise test conducted with a 30A PC board to maintain 20C max. rise at 30C. The relay connections and wiring must be designed with an adequate cross section to ensure proper current flow and heat dissipation. After cleaning process knock-off nib should be removed for optimum life of wash-tight relays. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 1 General Purpose High Power PCB Relays Potter & Brumfield T90 Series, 30A PCB Relay (Continued) Insulation Data Initial dielectric strength between open contacts between contact and coil Initial insulation resistance between insulated elements Clearance/creepage between contact and coil Other Data (continued) Vibration resistance (functional) 1.65mm max excursions, 10-55 Hz Shock resistance (functional) 10g for 11msec Shock resistance (destructive) 100g Terminal type PCB-tht Weight 20g open relay 26g wash-tight relay Resistance to soldering heat THT IEC 60068-2-20 250C Packaging/unit tray/50 pcs., box/500 pcs. 1500Vrms 1500Vrms 1x109 3.17mm Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature DC coil -55C to 85C 1) Category of environmental protection IEC 61810 RT0 - open, RTIII - wash tight 1) Operating ambient temperature must consider "Must Operate Voltage Change Over Temperature," Contact Temperature Rise, Coil Temperature Rise (If coil is not allowed to cool) and Maximum Coil Temperature. Specification ambient considers 20A load with coil cooled to ambient. Dimensions T90N .680 MAX. (17.27) .950 MAX. (24.13) T90S .031 x .062 (.79 x 1.58) TERMINALS .805 MAX. (20.4) .130 .020 (3.3 .51) .212 MAX. (5.38) .032 x .062 (.8 x 1.6) TERMINALS ) .10 MAX. (2.54) .50 (12.8) .69 (17.6) 1.20 MAX. (30.5) ( .130 + .016 - .010 3.30 + .41 -.25 1.27 MAX. (32.26) .025 x .025 (.64 x .64) TERMINALS .045 x .045 (1.14 x 1.14) TERMINALS Terminal assignment Bottom view on pins 1 form A .016 (.43) 1.08 MAX. (27.43) .025 x .025 2x (.64 x .64) TERMINALS .045 x .045 2x (1.14 x 1.14) TERMINALS PCB layout Bottom view on pins 1 form B .081 .005 DIA. (2.06 .13) 1 form C .300 (7.62) .100 (2.54) .600 (15.24) .600 (15.24) .043 .003 DIA. (1.09 .08) .150 (3.81) Note: This terminal is not present on relays with terminal code 4. .078 .003 DIA. (1.98 .08) Only necessary terminals are present on single throw models and terminal code 4 models. Consequently, some holes will be unnecessary for those models. .350 (8.89) .550 (13.97) .700 (17.78) Accessory Optional plastic dust cover is a snap-on unit, open on the PC board side of the relay. The cover, when ordered with the relay, is shipped separately. It is designed to be snapped into place by the customer after the relay has been assembled to the PC board. Product Code Description 35C620A Black dust cover, for use on T90N relay 35C620A 1.067 MAX. (27.1) .719 (18.26) .50 (12.7) .69 (17.5) Part Number 4-1393209-2 1.256 MAX. (31.9) .090 (2.29) 2 02-2014, Rev. 0214 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions .87 (22.1) Catalog product data, `Definitions' section, application notes and all specifications are subject to change. General Purpose High Power PCB Relays Potter & Brumfield T90 Series, 30A PCB Relay (Continued) Product code structure Typical product code T90 S 5 D 1 2 -24 Type T90 Power PCB relay T90 Enclosure N Open, no enclosure (snap-on dust cover available as an option) S Wash-tight, sealed plastic case with knock off nib for ventilation Contact arrangement 1 1 form A (1 NO) 2 1 form B (1 NC) 5 1 form C (1 CO) Coil Input D DC voltage Mounting and termination 1 PCB terminals 4 PCB terminals, no common terminal between coil terminals (see PCB layout/terminal assignment drawing) Note: Terminal code 4 recommended for UL 873 applications. Consult factory for use of terminal code 1 for UL 873 applications. Contact material 2 AgCdO Coil voltage Coil code: please refer to coil versions table Product Code Enclosure Contacts Terminals Contact Material Coil Part Number T90N1D12-5 T90N1D12-9 T90N1D12-12 T90N1D12-18 T90N1D12-24 T90N1D12-48 T90N1D12-110 T90N1D42-12 T90N1D42-24 T90N5D12-5 T90N5D12-12 T90N5D12-18 T90N5D12-24 T90N5D12-48 T90N5D12-110 T90N5D42-12 T90N5D42-24 T90S1D12-5 T90S1D12-6 T90S1D12-9 T90S1D12-12 T90S1D12-18 T90S1D12-24 T90S1D42-12 T90S1D42-24 T90S1D42-48 T90S5D12-5 T90S5D12-12 T90S5D12-18 T90S5D12-24 T90S5D12-48 T90S5D42-12 T90S5D42-18 T90S5D42-24 open, no cover 1 form A, 1 NO PCB AgCdO 5 VDC 9 VDC 12 VDC 18 VDC 24 VDC 48 VDC 110 VDC 12 VDC 24 VDC 5 VDC 12 VDC 18 VDC 24 VDC 48 VDC 110 VDC 12VDC 24 VDC 5 VDC 6 VDC 9 VDC 12 VDC 18 VDC 24 VDC 12 VDC 24 VDC 48 VDC 5 VDC 12 VDC 18 VDC 24 VDC 48 VDC 12 VDC 18 VDC 24 VDC 7-1393208-4 7-1393208-5 6-1393208-5 6-1393208-8 7-1393208-0 7-1393208-3 6-1393208-4 7-1393208-7 7-1393208-9 9-1393208-5 8-1393208-6 9-1393208-0 9-1393208-3 9-1393208-4 8-1393208-5 9-1393208-9 1393209-2 1-1393209-8 1-1393209-9 2-1393209-0 1-1393209-2 1-1393209-3 1-1393209-6 2-1393209-2 2-1393209-5 2-1393209-6 3-1393209-4 2-1393209-8 3-1393209-0 3-1393209-1 3-1393209-3 1423094-1 3-1393209-8 4-1393209-0 PCB, no extra COM 1 form C, 1 CO PCB PCB, no extra COM wash tight 02-2014, Rev. 0214 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. 1 form A, 1 NO PCB PCB, no extra COM 1 form C, 1 CO PCB PCB, no extra COM Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 3