45 Series - Miniature P.C.B. Relays 16 A + Faston 250 Features include: * Miniature P.C.B. Faston 250 mount relay * DC coil * 8 mm between coil and contacts in accordance with VDE 0700 * Sealed, with removable pip to avoid ozone accumulation when relay is operating * NO contact version (supplied as standard) * Approvals (accoding to type): CSA, cUL, IMQ, SEMKO, SEV, VDE AIR CONDITIONING IIII I II I I II I ELECTRONIC APPLIANCES I III WHITE GOODS 39 45 Series - Miniature P.C.B. Relays 16 A + Faston 250 45.61 C MINIATURE P.C.B. FASTON 250 POWER RELAY 16 A TYPE 45.61 1 NO (SPST-NO) 5 mm pinning - Tin plated connections for P.C.B. - Standard contact material: AgNi + AgCdO - Ordering information: see page 42 28.9 copper side view 14 1.5 11 14 A1 A2 28.9 6.3 11 12.3 18 7.5 28 1.5 5 A1 1 1 5 0.4 32.5 A2 3 40.5 TECHNICAL DATA DIELECTRIC STRENGTH tested at leakage current between coil and contacts 4,000 V 10 mA for 1 min at 50 Hz between open contacts 1,000 V SURGE TEST (1.2/50 s) VOLTAGE BETWEEN COIL AND CONTACTS 6,000 V ISOLATION RESISTANCE 20 * 103 M ISOLATION GROUP C 250 ISOLATION DISTANCES 8 mm between coil and contacts according to VDE 0700 MAXIMUM SWITCHING FREQUENCY - without load - at rated load 36,000 cycles/h 600 cycles/h AMBIENT TEMPERATURE (-40 ... +125)C MECHANICAL LIFE 20 * 106 cycles PROTECTION CATEGORY OF ENCLOSURES IP 67 OPERATE AND RELEASE TIME: - pick-up time (from 0 to UN) TYPE OF DUTY DIELECTRIC TEST TYPE OF RELAY 40 10 ms (including contact bounce) continuous 2 all-or-nothing 45 Series - Miniature P.C.B. Relays 16 A + Faston 250 CONTACT SPECIFICATIONS RATED CURRENT MAXIMUM PEAK CURRENT NOMINAL RATE IN AC1 NOMINAL RATE IN AC15 RATED VOLTAGE MAXIMUM SWITCHING VOLTAGE BREAKING CAPACITY IN DC1 SINGLE PHASE HP MOTOR RATING CONTACT RESISTANCE: - initial ELECTRICAL LIFE 16 A 30 A 4,000 VA 750 VA 250 V AC 400 V AC see diagram H 45 0.55 kW/0.8 HP 50 m 100 * 103 cycles, (+85C) 5 * 104 cycles, (+125C) 500 mW (10 V/5 mA) AgNi + AgCdO MINIMUM SWITCHING LOAD STANDARD CONTACT MATERIAL F 45 H 45 20 107 DC BREAKING CURRENT (A) CYCLES 10 106 105 6 4 2 1 0.6 0.4 0.2 0.1 0 1 2 3 4 LOAD (kVA) 20 60 100 140 180 220 DC VOLTAGE (V) Breaking capacity for DC1 load at 600 cycles/h. Contact life AC1 load at 900 cycles/h (+85C). K 45 k REDUCTION FACTOR 1 0.8 k 0.6 0.4 1 0.8 0.6 0.4 0.2 COS Load reduction factor vs cos . 41 45 Series - Miniature P.C.B. Relays 16 A + Faston 250 COIL SPECIFICATION VERSIONS: DC - direct current RATED POWER 0.65 W MINIMUM POWER 0.35 W OPERATING RANGE (0.73 ... 1.5) UN HOLDING VOLTAGE 0.4 UN MUST DROP-OUT VOLTAGE 0.1 UN NOMINAL MAGNETOMOTIVE FORCE 180 A THERMAL INSULATION CLASS OF WIRE F (+155C) THERMAL RESISTANCE 52C/W CONDUCTED DISTURBANCE IMMUNITY BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV) SURGE (acc. to EN 61000 - 4 - 5) level 3 (2 kV) DC VERSION DATA R values relate to +20C. Tolerance of R and I values: 10%. Nominal voltage UN Resistance Umin Umax R V V V Operating range 6 Nominal coil absorption I mA 4.4 9 55 109 12 8.8 18 220 55 24 17.5 36 900 27 48 35 72 3,500 14 60 43.8 90 5,500 11 110 80.3 165 18,000 6.1 R 45 2.5 S 45 80 Umin UN 1.5 UN 70 TEMPERATURE "t" (C) 1 2 1.5 1 2 0.5 -20 60 50 1.2 UN 40 UN 30 20 0.73 UN 10 -10 0 10 20 30 40 50 60 70 80 90 10 AMBIENT TEMPERATURE (C) 20 30 40 50 60 HEATING TIME (min) Temperature rise "t " vs applied voltage. DC coils. Operating range (DC type) vs ambient temperature 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature ORDERING INFORMATION Example: 45 series for P.C.B. + Faston 250, 1 NO (SPST-NO) contact, coil rated 12 V DC. 4 5 Series 6 1 No. of poles 1 = 1 NO (SPST-NO) Type 6 = P.C.B. + Faston 250 42 9 Coil version 9 = DC 0 1 2 Coil rated voltage 006 = 6V 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V 0 0 0 0