Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1800F Multi-Conductor - Single-Pair Cable For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (42x40) HC BC conductors, Datalene(R) insulation, conductors cabled with fillers, TC "French Braid" Shield (95% coverage), BC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material Dia. (mm) 1 24 42x40 BC - Bare Copper 0.6096 Total Number of Conductors: 2 Insulation Insulation Material: Insulation Trade Name Insulation Material Datalene(R) Dia. (mm) FHDPE - Foam High Density Polyethylene 1.4732 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) French Braid TC - Tinned Copper 95 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 26 Stranded BC - Bare Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 5.359 mm Pair Pair Color Code Chart: Number Color 1 Red & Black Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +60C Non-UL Temperature Rating: 60C Bulk Cable Weight: 35.717 Kg/Km Max. Recommended Pulling Tension: 184.600 N Min. Bend Radius/Minor Axis: 57.150 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL2R Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1800F Multi-Conductor - Single-Pair Cable EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Other Specification: AES/EBU Digital Audio Flame Test UL Flame Test: UL1666 Riser Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 110 Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 39.372 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 85.306 Nominal Velocity of Propagation: VP (%) 76 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 77.7597 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 21.064 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100m) .384 1.50926 .706 2.19827 .768 2.2967 1.024 2.72323 1.411 3.41224 1.536 3.57629 2.048 4.2653 2.822 5.44646 3.072 5.74175 4.096 7.31663 5.645 9.48209 6.144 10.0727 Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1800F Multi-Conductor - Single-Pair Cable 8.192 12.1725 11.290 14.8629 12.288 15.6832 24.576 23.3279 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.75 Amps per conductor @ 25C Notes (Overall) Notes: Datalene(R) insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. Put Ups and Colors: Item # Putup Ship Weight Color 1800F B59U1000 305 MT 11.793 KG BLACK, MATTE Notes Item Desc 1800F B591000 305 MT 11.793 KG BLACK, MATTE C #24 PR FHDPE BRD PVC 1800F B59500 152 MT 6.124 KG BLACK, MATTE C #24 PR FHDPE BRD PVC 1800F G7VU1000 305 MT 11.793 KG RED, MATTE #24 PR FHDPE BRD PVC 1800F G7WU1000 305 MT 11.793 KG GREEN, MATTE #24 PR FHDPE BRD PVC 1800F G7XU1000 305 MT 11.793 KG BLUE, MATTE #24 PR FHDPE BRD PVC 1800F G8MU1000 305 MT 11.793 KG YELLOW, MATTE #24 PR FHDPE BRD PVC 1800F U90U1000 305 MT 11.793 KG GRAY, MATTE #24 PR FHDPE BRD PVC 1800F Z4BU1000 305 MT 11.793 KG VIO Z4B #24 PR FHDPE BRD PVC #24 PR FHDPE BRD PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 06-22-2010 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013