General Purpose US US Fuses General Purpose Fuses American Power Fuses AMP-TRAP 2000(R) ATQR (Class CC TD) Take control of fault currents headed for your control transformer ATQR small-dimension fuses feature time delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. The newest member of our Amp-trap 2000(R) family of fuses - ATQR fuses provide superior protection for the branch circuits of electrical distribution systems. Features /Benefits Applications * Time delay for control transformer inrush loads without nuisance opening * Highly current limiting for low peak let-thru current * Rejection-style design prevents replacement errors (when used with recommended fuse blocks) * High-visibility orange label ensures instant recognition, and simplifies replacement * Metal-embossed date and catalog number for traceability and lasting identification * Fiberglass body provides dimensional stability in harsh industrial settings * High-grade silica filler ensures fast arc quenching and high current limitation * * * * Control Transformers Solenoids Inductive Loads Lighting, Heating and General-purpose Loads Approvals * UL Listed to Standard 248-4 * CSA Certified to Standard C22.2 No. 248.4 Ratings AC: 1/10 to 30A 600VAC, 200kA I.R. Highlights * Time Delay * Best Choice for Small Transformer Protection * Most Current-Limiting GPUS21 12/04 General Purpose General Purpose US Fuses US Fuses American Power Fuses AMP-TRAP 2000(R) ATQR (Class CC TD) Standard Fuse Ampere Ratings, Reference Numbers Ampere Rating Catalog Number Reference Number Ampere Rating Catalog Number 1/10 1/8 15/100 3/16 2/10 1/4 3/10 4/10 1/2 6/10 3/4 8/10 1 1-1/8 1-1/4 1-4/10 1-1/2 1-6/10 1-8/10 2 2-1/4 2-1/2 ATQR1/10 ATQR1/8 ATQR15/100 ATQR3/16 ATQR2/10 ATQR1/4 ATQR3/10 ATQR4/10 ATQR1/2 ATQR6/10 ATQR3/4 ATQR8/10 ATQR1 ATQR1-1/8 ATQR1-1/4 ATQR1-4/10 ATQR1-1/2 ATQR1-6/10 ATQR1-8/10 ATQR2 ATQR2-1/4 ATQR2-1/2 E201921 A212175 S223507 J222556 Q216766 V211664 V219875 D211143 C211142 V213711 A223077 L215750 F218827 H222555 T219874 Z223076 T219345 E200863 R201403 D214731 K215749 G215240 2-8/10 3 3-2/10 3-1/2 4 4-1/2 5 5-6/10 6 6-1/4 7 7-1/2 8 9 10 12 15 17-1/2 20 25 30 ATQR2-8/10 ATQR3 ATQR3-2/10 ATQR3-1/2 ATQR4 ATQR4-1/2 ATQR5 ATQR5-6/10 ATQR6 ATQR6-1/4 ATQR7 ATQR7-1/2 ATQR8 ATQR9 ATQR10 ATQR12 ATQR15 ATQR17-1/2 ATQR20 ATQR25 ATQR30 Reference Number Q216260 T218310 V219346 G218828 S201404 F201922 W211665 B212176 T212698 D213213 B214223 E214732 H215241 R216261 S212697 C213212 T213710 A214222 D217284 H217794 F200864 Recommended ATQR Class CC Primary Fuses For Single Phase Control Transformers Trans Primary VA Volts Fla 600 0.04 480 0.05 240 0.10 25 208 0.12 120 0.21 600 0.08 480 0.10 240 0.21 50 208 0.24 120 0.42 600 0.13 480 0.16 240 0.31 75 208 0.36 120 0.63 600 0.17 480 0.21 240 0.42 100 208 0.48 120 0.83 600 0.25 480 0.31 240 0.63 150 208 0.72 120 1.25 600 0.33 480 0.42 240 0.83 200 208 0.96 120 1.67 600 0.42 480 0.52 250 240 1.04 208 1.2 120 2.08 12/04 ATQR AMPS 1/10 1/10 2/10 1/4 4/10 1/4 1/4 4/10 1/2 6/10 1/4 3/10 1/2 3/4 1 3/10 4/10 6/10 1 1-1/2 1/2 1/2 1 1-1/2 2-1/2 1/2 6/10 1-1/2 2 3 6/10 1-1/8 2 3 4* * Secondary protection is required for these ratings. + Fuse will withstand 30 x FLA for .01 second ++ Fuse will withstand 25 x FLA for .01 second GPUS22 Trans Primary VA Volts Fla 0.50 600 480 0.63 300 240 1.25 208 1.44 120 2.5 600 0.83 480 1.04 500 240 2.08 208 2.40 120 4.17 600 1.25 480 1.56 750 240 3.13 208 3.61 120 6.25 600 1.67 480 2.08 1000 240 4.16 208 4.81 120 8.33 600 2.50 480 3.13 1500 240 6.25 208 7.21 120 12.5 600 3.33 2000 480 4.17 240 8.33 208 9.62 600 5.00 3000 480 6.25 240 12.5 5000 600 8.33 480 10.4 ATQR AMPS 1-1/8 1-1/2 2-1/2 3 5* 1-1/2 2 4* 6* 10* 2-1/2 3 7* 8* 15* 3 4* 10* 12* 20* 5* 7* 10 20* 25* 8* 10* 20++* 20++* 12+* 15+* 30++* 20++* 25+* General Purpose US US Fuses General Purpose Fuses American Power Fuses AMP-TRAP 2000(R) ATQR (Class CC TD) Recommended Fuse Blocks for Class CC Fuses Catalog Number Number of Poles Ultrasafe Indicating Fuse Holder Screw with Double Quick Connects Pressure Plate with Double Quick Connects Copper Box Connector ADDER 1 2 3 USCC1I USCC2I USCC3I 30310R 30311R 30312R 30313R 30320R 30321R 30322R 30323R 30350R 30351R 30352R 30353R Number of Poles Ultrasafe Indicating Fuse Holder Screw with Double Quick Connects Pressure Plate with Double Quick Connects Copper Box Connector ADDER 1 X213943 W204857 R212397 Z217510 M218534 N213429 G213929 2 3 D217008 Y218038 Z212910 M213428 Y219579 B222779 V214447 X214955 Reference Number Primary fuses - If primary FLA is less than 2 amps, fuse may be 300% max. (500% for motor control). If primary FLA exceeds 2 amps but is less than 9 amps, fuse may not exceed 167% of primary FLA unless secondary protection is used, when it may be increased to 250%. Fuse sizes shown are based on approx. 40 x FLA for .01 sec. Dimensions GPUS23 12/04 General Purpose General Purpose US Fuses US Fuses American Power Fuses AMP-TRAP 2000(R) ATQR (Class CC TD) CURRENT IN AMPERES MELTING TIME - CURRENT DATA, 600V FUSES ATQR 1/8 to 30 TIME IN SECONDS MAX. INSTANTANEOUS PEAK LET-THRU CURRENT Peak Let-Thru Current Data - ATQR 1/8 to 30, 600 Volts AC AVAILABLE CURRENT IN RMS SYM. AMPERES 12/04 GPUS24