Product Specification
02097-DSH-001-C Mindspeed Technologies®7
Preliiminary Information/Mindspeed Proprietary and Confidential
Preliminary Information
Table 1-8. Circuit Response to Single-Point Fault Conditions on Driver Pins
Pin Name Circuit Response to Over-voltage Condition or Short to
VCC
Circuit Response to Under-Voltage Condition or Short
to Ground
Config1-4 Does not affect output power (some conditions can selectively
enable/disable driver output).
Does not affect output power (some conditions can selectively
enable/disable driver output).
VCC Outputs are disabled if VCC exceeds the VCC_okay (high level)
threshold. If so, FAIL will be asserted. (1)
Outputs are disabled if VCC voltage is below the VCC_okay (low
level) threshold. If so, FAIL will be asserted. (1)
VCC3T Outputs are disabled if VCC3 exceeds the VCC3_okay (high level)
threshold. If so, FAIL will be asserted. (1)
Outputs are disabled if VCC3 voltage is below the VCC3_okay
(low level) threshold. If so, FAIL will be asserted. (1)
DINp, DINm LED would remain in an optical one or zero condition. LED would remain in an optical one or zero condition.
CPB Pre-bias current is turned off. Does not affect LED operation. A fault state occurs.(2)
FAIL Does not affect LED operation. Does not affect LED operation.
DIS Bias and modulation outputs are disabled and SVCC is opened. Does not affect LED operation (normal condition for circuit
operation).
MODSET No modulation current. A fault state occurs. (2)
PBSET Pre-bias current is turned off. Does not affect LED power. A fault state occurs. (2)
TCSTART Modulation current may increase depending on operating
temperature and TCSLOPE setting.
Modulation current may decrease depending on operating
temperature and TCSLOPE setting.
TCSLOPE Modulation current may decrease depending on operating
temperature and TCSTART setting.
Modulation current may increase depending on operating
temperature and TCSTART setting.
PBOUT The LED is turned off if connected to the LED cathode. A fault state occurs. (2)
OUTP LED modulation is prevented and a fault state occurs. (2) A fault state occurs. (2)
OUTN Does not affect LED operation. Does not affect LED operation.
GNDO LED modulation is prevented and a fault state may occur. (2) Does not affect LED operation.
SVCC Does not affect LED operation. The LED is turned off and a fault state occurs. (2)
NOTES:
1. In this case a fault state will assert the FAIL output, but it is not latched. While the fault condition remains, the bias and modulation outputs are
disabled and the switch at SVCC is open. No fault occurs if in Safety Circuit Bypass (SCB).
2. In this case a fault state will assert and latch the FAIL output, disable bias and modulation outputs and open the switch at SVCC. No fault occurs
if in Safety Circuit Bypass (SCB).