Address:
Email:sal
e
Website:
w
Tel:+44(0
Fax:+44(
0
MidasCompone
n
e
s@midascomp
o
w
ww.midascom
p
)1493602602
0
)1493665111
n
tsLtd, Electra H
o
nents.co.uk
p
onents.co.uk
ouse, 32 Southt
o
o
wn Road, Great
Yarmouth,Norf
o
o
lk, England, NR31ODU
BOOKBINDING AREA
DOC. DATASHEET STATEMENT
The following icons are absolutely designed by Midas independently in 2007-SEP. They are not in common
use in the LCD industry yet but just used for marking out Midas products’ characteristics quickly and
simply without any special meaning. Midas reserves the composing right and copyright.
No one else is allowed to adopt these icons without Midas approval.
1.
The ISO9001 logo used in this document is authorized by SGS (www.sgs.com). Midas had already
successfully passed the strict and professional ISO9001:2000 Quality Management System Certification and
got the certificate (No.: CN07/00404)
2.
The technologies/techniques/crafts which denoted by the following icons are not exclusively owned by Midas,
but also shared by Midas LCD strategic cooperators, however all these technologies/techniques/crafts have
been finally confirmed by Midas professional engineers and QC department.
3.
SAMPLE APPROVAL document rather than consider this DATASHEET as the standard for judging whether or not the
LCD meets your requirements. Once you instruct Midas to a mass-production without definite demand for
providing sample before, Midas will disclaim all responsibility if the mass-production is proved not meeting with
your requirements.
As the difference in test standard and test conditions, also Midas insufficient familiarity with the actual LCD
using environment, all the referred information in this DATASHEET (including the icons) only have two functions:
4.1: providing quick reference when you are judging whether or not the product meets your requirements.
4.2: listing out definitely the tolerance.
4.
The sequence of the icons is random and doesn’t indicate the importance grade.
5.
Icons explanation
6.
This icon on the cover indicates the product
is with high contrast; Otherwise not.
HIGH CONTRAST LONG LIFE VERSION
This icon on the cover indicates the product
is long life version (over 9K hours guaranteed);
Otherwise not.
HC
3.0V
Vlcm=3.0V
This icon on the cover indicates the product
can work at 3.0V exactly; otherwise not.
3TIMEs 100% QC EXAMINATION
This icon on the cover indicates the product
has passed Midas thrice 100% QC.
Otherwise not.
This icon on the cover indicates the LED had passed
Midas twice strict selection which promises the
product’s identical color and brightness; Otherwise not.
TWICE SELECTION OF LED MATERIALS
This icon on the cover indicates the product
is with high response speed; Otherwise not.
FAST RESPONSE TIME
This icon on the cover indicates the product
is with protection circuit; Otherwise not.
PROTECTION CIRCUIT
FFF
YC
XC
OPERATION TEMPERATURE RANGE
This icon on the cover indicates the operating
temperature range (X-Y).
This icon on the cover indicates the product
meets ROHS requirements; Otherwise not.
RoHS COMPLIANCE
RoHS
Midas 2006 version logo.Midas is an integrated manufacturer of flat
panel display (FPD). Midas supplies TN, HTN, STN, FSTN monochrome
LCD panel; COB, COG, TAB LCD module; and all kinds of LED backlight.
WIDE VIEWING SCOPE
This icon on the cover indicates the product
is with wide viewing scope; Otherwise not.
Anti UV VERSION
This icon on the cover indicates the product
is against UV line. Otherwise not.
UV
N
New structure, new craft, new
technology and new materials inside both LCD
module and LCD panel to improve the "RainBow"
N SERIES TECHNOLOGY (2008 developed)
PAGE 1/20
BOOKBINDING AREA
STANDARD
DOC. REVISION RECORD
DESCRIPTION
INITIAL ISSUED
DATE
2005.05
ITEM
ALL
PAGE
ALL
APPROVEDNO.
1
Added further information of LED backlight
2007.04 4 4/20
2
Adopt logos on the cover for fast reference
2008.01 -Cover
3
LU BOO
Deleted “N = No Ic from CODE2
2008.10
4-
Code System
Added CODE “B” for DFSTN version in CODE7
2008.10
5-
Code System
Midas LCD Part Number System
MC
COG
132033
A
*
6
W
*
*
-
S
N
T
L
W
*
*
1
2
3
4
5
6
7
8
9
-
10
11
12
13
14
15
16
1 = MC: Midas Components
2 = Blank: COB (chip on board) COG: chip on glass
3 = No of dots (e.g. 240064 = 240 x 64 dots) (e.g. 21605 = 2 x 16 5mm C.H.)
4 = Series
5 = Series Variant: A to Z
6 = 3: 3 o’clock 6: 6 o’clock 9: 9 o’clock 12: 12 o’clock
7 = S: Normal (0 to + 50 deg C) W: Wide temp. (-20 to + 70 deg C) X: Extended temp (-30 + 80 Deg C)
8 = Character Set
Blank: Standard (English/Japanese)
C: Chinese Simplified (Graphic Displays only)
CB: Chinese Big 5 (Graphic Displays only)
H: Hebrew
K: European (std) (English/German/French/Greek)
L: English/Japanese (special)
M: European (English/Scandinavian)
R: Cyrillic
W: European (English/Greek)
U: European (English/Scandinavian/Icelandic)
9 = Bezel Height (where applicable / available)
Top of Bezel to Top
of PCB
Common
(via pins 1
and 2)
Array
or Edge
Lit
Blank
9.5mm / not
applicable
Common
Array
2
8.9 mm
Common
Array
3
7.8 mm
Separate
Array
4
7.8 mm
Common
Array
5
9.5 mm
Separate
Array
6
7 mm
Common
Array
7
7 mm
Separate
Array
8
6.4 mm
Common
Edge
9
6.4 mm
Separate
Edge
A
5.5 mm
Common
Edge
B
5.5 mm
Separate
Edge
10 = T: TN S: STN B: STN Blue G: STN Grey F: FSTN F2: FFSTN
11 = P: Positive N: Negative
12 = R: Reflective M: Transmissive T: Transflective
13 = Backlight: Blank: Reflective L: LED
14 = Backlight Colour: Y: Yellow-Green W: White B: Blue R: Red A: Amber O: Orange G: Green RGB: R.G.B.
15 = Driver Chip: Blank: Standard I: I2C
16 = Voltage Variant: e.g. 3 = 3v
F/Displays/Midas Brand/Midas LCD Part Number System 2 March 2011.doc
PAGE 3/20
BOOKBINDING AREA
STANDARD
DOC. CONTENTS
GENERAL SPECIFICATIONS --------------------------------------------1.
Page 4
MECHANICAL SPECIFICATIONS --------------------------------------2.
Page 4
ABSOLUTE MAXIMUM RATINGS --------------------------------------3.
Page 4
ELECTRONICAL CHARACTERISTIC ---------------------------------4.
Page 4
OPTICAL CHARACTERISTICS ------------------------------------------5.
Page 5
ELECTRICAL SPECIFICATIONS----------------------------------------6.
Page 6
EXTERNAL DIMENSION---------------------------------------------------7.
Page 8
PIN ASSIGNMENT ----------------------------------------------- -----------8.
Page 9
POWER SUPPLY ------------------------------------------------------------9.
Page 9
REFLECTOR OF SCREEN AND DDRAM ADDRESS --------------10.
Page 9
INITIALIZATION -------------------------------------------------------- ------ -
15.
Page 16
INTERFACE TO MPU ------------- -------------------------------------------
16.
Page 18
INSTRUCTION TABLE11.
Page 10
---------------------------------------------------
12.
Page 11
INSTRUCTION DESCRIPTION
-------------------------------------------
13.
Page 15
CGRAM
-----------------------------------------------------------------------
14.
Page 15
DDRAM
-------------------------------------- ---------------------------- -----
17.
Page 19
FONT MAP
---------------- -- ------------------- ------------------------------
18.
Page 20
PACKING DETAIL
---------------------------------------------------------
PRODUCT
SPEC.
MODE NO. PAGE
BOOKBINDING AREA
16 Characters by 1 Line
1/16
1. GENERAL SPECIFICATIONS
4/20
ITEM NOMINAL DIMENSIONS / AVAILABLE OPTIONS
DISPLAY FORMAT
LCD PANEL OPTIONS
POLARIZER OPTIONS
BACKLIGHT OPTIONS
VIEWING ANGLE OPTIONS
TEMPERATURE RANGE OPTIONS
CONTROLLER IC
DISPLAY DUTY
DRIVING BIAS 1/5
SUNPLUS
ITEM SYMBOL CONDITION MIN MAX UNIT
Vdd 25 C -0.3 7.0 V
V0 25 C Vdd -13.5 Vdd +0.3 V
Vin 25 C -0.3 Vdd +0.3 V
Vopr
Vstg
___
___
C
C
3. ABSOLUTE MAXIMUM RATINGS
POWER SUPPLY ( LOGIC)
POWER SUPPLY (LCD)
INPUT VOLTAGE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
STN (Yellow-green color)
Positive, Transflective
Array type LED backlight (Yellow-green color)
6:00(Bottom)
-20 70
-30 80
Widetemp.range(-20C~70C)
2. MECHANICAL SPECIFICATIONS
OVERALL SIZE LED backlight version : 80.0 x 36.0 x max 13.5
VIEWING AREA 64.5W x 13.8H HOLE-HOLE 75.0W x 31.0H
mm
CHARACTER SIZE 3.07W x 6.56H mm CHARACTER PITCH 0.70W
mm
mm
mm
mm
DOT SIZE 0.55W x 0.75H mm DOT PITCH 0.08W x 0.08H
ITEM SYMBOL CONDITION STANDARD UNIT
MIN TYP MAX
Input voltage Vdd +5V 4.7 5.0 5.5 V
110
___
___
___
Supply current Idd Vdd=5V mA
Vdd-V0
0C
V
25 C
50 C
LED forward voltage Vf 25 C V
LED forward current If 25 C mA
Recommended LCD driving
voltage for normal temp.
Version module
LED reverse Current
LED Peak wave length
LED illuminance (Without LCD)
25 C
LED life time
-20 C
70 C
___
3.8 4.4
___
___
___
___
___
Hours
___ ___
568 575
___
110
___ ___
Lv
___
nm
p
25 C If = 110mA
25 C If = 110mA
25 C If = 110mA
4. ELECTRONICAL CHARACTERISTIC*
9K**
Ir
* The above data are for reference only.
** The warranty period of FORDATA LCD module is 1YEAR counted from the date shown on the label of products.
A
1.3
90 ___ 120
FDCC1601E-FLYYBW-51LK
4.504.20 4.70
4.30
4.50
4.15
4.00
4.65
4.80
5.00
4.60
PRODUCT
SPEC.
MODE NO. PAGE 5/20
BOOKBINDING AREA
ITEM SYMBOL CONDITION MIN MAX UNIT
K=4 30
VIEWING ANGLE 25 deg
CONTRAST RATIO 2
RESPONSE TIME(RISE) 120
___
___
TYP
RESPONSE TIME(FALL) ___
___
______
120
150
150
___ ___
___ ___
FOR TN TYPE LCD MODULE (T =25 C, Vdd=5.0V 0.25V)
A
ITEM SYMBOL CONDITION MIN MAX UNIT
K=4 40
VIEWING ANGLE 60 deg
CONTRAST RATIO 6
RESPONSE TIME(RISE) 150
___
___
TYP
RESPONSE TIME(FALL) ___
___
______
150
250
250
___ ___
___ ___
FOR STN TYPE LCD MODULE (T =25 C, Vdd=5.0V 0.25V)
A
1.4
12
Viewing Angle
Contrast Ratio K
XX`
Y( =180 ) 1
2
DEFINITION OF ANGLE & DEFINITION OF VIEWING ANGLE 1 & 2
B2
B1
Setpoint Driving Voltage
Brightness(%)
Brlghtness(%)
Rise Time Fall Time
Time(ms)
Select Signal Non-Select
TRTF
90%
100%
10%
Non-Select
Brightness Curve for
selected Segment
Brightness Curve for
Non- selected Segment
DEFINITION OF CONTRAST RATIO K(=B /B )21 DEFINITION OF OPTICAL RESPONSE TIME T & TRF
Y( =0 )
ms
ms
ms
ms
5. OPTICAL CHARACTERISTIC
K
TR
TF
21
_
K
TR
TF
21
_
PRODUCT
SPEC.
MODE NO. PAGE 6/20
BOOKBINDING AREA
6. ELECTRICAL SPECIFICATIONS
6.1 DC CHARACTERISTICS ( VDD = 4.5V to 5.5V, TA = 25 C )
INPUT HIGH VOLTAGE
INPUT LOW VOLTAGE
Pins ( E. RS. R/W. DB0 - DB7 )
Pins ( RS. R/W. DB0 - DB7 )
Vdd = 5.0V
Write mode
Read mode
6.2 AC CHARACTERISTICS ( VDD = 4.5V to 5.5V, TA = 25 C )
VIH1
VIL1
V
V
CHARACTERISTICS TEST CONDITIONSYMBOL LIMIT
MIN. TYP. MAX. UNIT
CHARACTERISTICS TEST CONDITION
ENABLE CYCLE TIME
ADDRESS HOLD TIME
ENABLE PULSE WIDTH
ENABLE RISE/ FALL TIME
ADDRESS SETUP TIME
DATA SETUP TIME
DATA HOLD TIME
Pins RS, R/W, E
Pins: DB0 - DB7
SYMBOL LIMIT
MIN. TYP. MAX. UNIT
tC
tPW
t,tRF
tSP1
tHD1
500
230
80
10
40
10
20
ns
tHD2
tSP2
ns
ns
ns
ns
ns
ns
Pin E
Pins: DB0 - DB7
Pins RS, R/W, E
Pin E
Pin E
CHARACTERISTICS TEST CONDITION
ENABLE CYCLE TIME
ADDRESS HOLD TIME
ENABLE PULSE WIDTH
ENABLE RISE/ FALL TIME
ADDRESS SETUP TIME
DATA OUTPUT DELAY TIME
DATA HOLD TIME
Pins RS, R/W, E
Pins: DB0 - DB7
SYMBOL LIMIT
MIN. TYP. MAX. UNIT
tC
tPW
t,tRF
tSP1
tHD1
500
230
5
40
10
20
ns
tHD2
tD
ns
ns
ns
ns
ns
ns
Pin E
Pins: DB0 - DB7
Pins RS, R/W, E
Pin E
Pin E
120
2.2
-0.3
Vdd
0.6
INPUT HIGH CURRENT IIH -2.0 2.0
OUTPUT HIGH
VOLTAGE ( TTL )
INPUT LOW CURRENT
OUTPUT LOW
VOLTAGE ( TTL )
I =-0.1mA
Pins: DB0 - DB7
OH
I = 0.1mA
Pins: DB0 - DB7
OL
IIL
VOH1
V
V
A
VOL1
2.4
0.4
Vdd
-20 -50 -100
A
6.3.1 WRITE MODE TIMING DIAGRAM
RS
R/W
E
DB0-DB7
VIH1
VIL1
tSP1
VIL1
VIH1
VIL1
tHD1
VIL1
tPW
tHD1tF
VIH1
VIL1
VIH1
VIL1
VIH1
VIL1
VIH1
VIL1
tRtSP2
tC
tHD2
VIL1
Valid Data
6.3.2 READ MODE TIMING DIAGRAM
RS
R/W
E
DB0-DB7
VIH1
VIL1
tSP1
VIH1
VIL1
tHD1
tPW
tHD1tF
VIH1
VIL1
VIH1
VIL1
VIH1
VIL1
VIH1
VIL1
tRtD
tC
tHD2
VIL1
Valid Data
VIH1 VIH1
PRODUCT
SPEC.
MODE NO. PAGE 7/20
BOOKBINDING AREA
PRODUCT
SPEC.
MODE NO. PAGE 8/20
BOOKBINDING AREA
7. EXTERNAL DIMENSIONS
0.75
0.08
6.56
0.08
3.77
3.07
0.55
Vss
Vdd
Vo
RS
R/W
E
DB 0
DB 7
U1
8
COM1
COM16
COM16 LCD
SEG1
16 1
SEG40
SEG1--40
40
16
LED BACKLIGHT
PIN15
PIN16
R
T2
T1
1.6
16
1
13.8 V.A.
24.5 0.2
31.0 0.2 H.H.
36.0 0.5 O.S.
80.0 0.5 O.S.
75.0 0.2 H.H.
64.5 0.2 V.A.
70.8 0.2
P2.54X15
0 1.00 16PL
59.62
6.56
0 2.5 4PL
2.0
7.5
A
K
UNIT
ITEM T2T1
LED backlight
EL or without backlight mm
mm
8.5
4.5
13.5
9.5
FDCC1601E-FLYYBW-51LK
PRODUCT
SPEC.
MODE NO. PAGE
BOOKBINDING AREA
8.PIN ASSIGNMENT
10. REFLECTOR OF SCREEN AND DDRAM ADDRESS
PIN SYMBOL FUNCTION
1Vss
2Vdd
3V0
4RS
LED+
LED-
7-14 DB0 - DB7
5R/W
6E
Display position
DDRAM address
Display position
DDRAM address
Display position
DDRAM address
1-1 means first character of line 1 on screen
Display position
DDRAM address
Display position
DDRAM address
Display position
DDRAM address
Display position
DDRAM address
Display position
DDRAM address
1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8
00 01 02 03 04 05 06 07 08 09
0A 0B 0C 0D 0E 0F 10 11 12 13
14 15 16 17 18 19 1A 1B 1C 1D
1E 1F 20 21 22 23 24 25 26 27
1-9 1-10 1-11 1-12 1-13 1-14 1-15 1-16
40 41 42 43 44 45 46 47 48 49
4A 4B 4C 4D 4E 4F 50 51 52 53
54 55 56 57 58 59 5A 5B 5C 5D
5E 5F 60 61 62 63 64 65 66 67
9/20
16
15
Contrast Adjust
Data bus line
Register Select Signal
Data Read / Write
Enable Signal
GND
Power supply for BKL (0V)
Power supply for BKL (+5.0V)
Power supply for LCM (+5.0V)
9.POWER SUPPLY
SINGLE SUPPLY TYPES
VDD-VO: LCD DRIVING VOLTAGE
RPOT: 10K-20K
Vdd
+5V
Vdd ~
Vdd
RPOT
VSS V0
V0
PRODUCT
SPEC.
MODE NO. PAGE 10/20
BOOKBINDING AREA
Instruction Code
Instruction
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Description
Execution
Time(fosc=
270kHz)
Clear Display 0 0 0 0 0 0 0 0 0 1 1.52ms
Return Home 0 0 0 0 0 0 0 0 1 - 1.52ms
Entry Mode
Set 0 0 00 00 01I/DSH
Assign cursor moving
direction and enable the
shift of entire display
38
Display
ON/OFF
Control
0000001DCB
Set display(D)
cursor(C) and blinking
of cursor(B) on/off
38
Cursor or
Display Shift 0 0 00 01S/CR/L- -
Set cursor moving and
display shift control
bit, and the direction,
without changing
DDRAM data
38
Function Set 0 0 0 0 1 DL N F - -
Set interface data
length(DL:8bit/4bit),
number of display line
(N:2line/1line)
and,display font type
F:5X11dots / 5X8dots
38
Set CGRAM
Address 0 0 0 1 AC5 AC4 AC3 AC2 AC1 AC0 Set CGRAM address in
address counter 38
Set DDRAM
Address 001 Set DDRAM address in
address counter 38
Read Busy
Flag and
Address
01BF
Whether during internal
operation or not can be
known by reading BF
The contents of address
counter can also be read
0
Write Data to
RAM 1 0 D7 D6 D5 D4 D3 D2 D1 D0 Write data into internal
RAM (DDRAM/CGRAM) 38
Read data
from RAM 1 1 D7 D6 D5 D4 D3 D2 D1 D0 38
Write 20H to DDRAM
set DDRAM address to
00H from AC
Set DDRAM address to
00H from AC and return
cursor to its original
position if shifted. The
contents of DDRAM are
not changed.
Read data from internal
RAM (DDRAM/CGRAM)
AC6 AC5 AC4 AC3 AC2 AC1 AC0
AC6 AC5 AC4 AC3 AC2 AC1 AC0
11. INSTRUCTION TABLE
FDCC1601E-FLYYBW-51LK
A. Clear Display
Clear all the display data by writing 20H (space code) to all DDRAM address, and set
DDRAM address to 00H into AC (address counter).
Return cursor to the original status, namely, bring the cursor to the left edge on the first line
of the display.
Make the entry mode increment ( I/D = HIGH )
B. Return Home
Return cursor to its original site and return display to its original status,if shifted.
Contents of DDRAM does not change.
C. Entry Mode Set
Set the moving direction of cursor and display.
I/D:Increment /decrement of DDRAM address(cursor or blink)
I/D=High,cursor/blink moves to right and DDRAM address is increased by 1.
I/D=low,cursor/blink moves to left and DDRAM address is decreased by 1.
*CGRAM operates the same way as DDRAM, when reading from or writing to CGRAM.
SH:Shift of entire display
When DDRAM read (CGRAM read/write) operation or SH=Low,shifting of entire
display is not performed.if SH=High, and DDRAM write operation,shift of entire display
is performed according to I/D value(I/D=High,shift left, I/D=Low, shift right).
0000000001
000000001-
00000001I/DSH
PRODUCT
SPEC.
MODE NO. PAGE 11/20
BOOKBINDING AREA
12. INSTRUCTION DESCRIPTION
Set DDRAM address to 00H into the address counter.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
D. Display ON/OFF Control
D:Display ON/OFF control bit
When D=High, entire display is turned on.
When D=Low, display is turned off, but display data remains in DDRAM.
C:Cursor ON/OFF control bit
When C=High, cursor is turned on.
When C=Low, cursor is disappeared in current display ,but I/D register preserves its data.
B:Cursor Blink ON/OFF control bit
and display characters at the cursor position.
WhenB=Low,blinkisoff.
E. Cursor or Display Shift
Shifting of right/left cursor position or display without writing or reading of display data.
This instruction is used to correct or search display data.
During 2-line mode display, cursor moves to the 2
ndline after the 40th
digit of the 1st line.
Note that display shift is performed simultaneously in all the lines.
When displayed data is shifted repeatedly, each line is shifted individually.
When display shift is performed, the contents of the address counter are not changed.
0000001DCB
000001S/CR/L- -
S/C R/L Operation
0 0 Shift cursor to the left, AC is decreased by 1
0 1 Shift cursor to the right, AC is increased by 1
10
Shift all the display to the left,cursor moves according to the display
11
Shift all the display to the right,cursor moves according to the display
PRODUCT
SPEC.
MODE NO. PAGE 12/20
BOOKBINDING AREA
When B=High, cursor blink is on, which performs alternately between all the High data
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
F. Function set
DL:Interface data length control bit
When DL=High, it means 8-bit bus mode with MPU.
When DL=Low, it means 4-bit bus mode with MPU.
When 4-bit bus mode, it needs to transfer 4-bit data twice.
N:Display line number control bit
When N=Low, 1-line display mode is set.
When N=High, 2-line display mode is set.
F:Display font type control bit
When F=Low, 5x8 dots format display mode is set.
When F=High, 5x11 dots format display mode.
G. Set CGRAM Address
Set CGRAM address to AC.
This instruction makes CGRAM data available from MPU.
H. Set DDRAM Address
Set DDRAM address to AC.
This instruction makes DDRAM data available from MPU.
In 2-line display mode(N=High),DDRAM address in the 1
st line is from 00H to
27H and DDRAM address in the 2nd
00001DLNF- -
0 0 0 1 AC5 AC4 AC3 AC2 AC1 AC0
0 0 1 AC6 AC5 AC4 AC3 AC2 AC1 AC0
PRODUCT
SPEC.
MODE NO. PAGE 13/20
BOOKBINDING AREA
WWhen 1-line display mode (N=Low), DDRAM address is from 00H to 4FH
line is from 40H to 67H
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
I. Read Busy Flag & Address
This instruction shows whether IC is in internal operation or not .
you and also read the value of the address counter.
J. Write data to RAM
Write binary 8-bit data to DDRAM/CGRAM.
The selection of RAM from DDRAM,and CGRAM,is set by the previous address set
instruction(DDRAM address set,CGRAM address set).
RAM set instruction can also determine the AC direction to RAM.
After write operation, the address is automatically increased /decreased by 1,according the
entry mode.
K. Read data from RAM
Read binary 8-bit data from DDRAM/CGRAM.
The selection of RAM is set by the previous address set instruction.If the address set
instruction of RAM is not performed before this instruction, the data that has been read
first is invalid, as the direction of AC is not yet determined. If RAM data is read several
times without RAM address instructions set before read operation,the correct RAM data
can be obtained from the second. But the first data would be incorrect,as there is no time
margin to transfer RAM data.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0 1 BF AC6 AC5 AC4 AC3 AC2 AC1 AC0
1 0 D7 D6 D5 D4 D3 D2 D1 D0
1 1 D7 D6 D5 D4 D3 D2 D1 D0
PRODUCT
SPEC.
MODE NO. PAGE 14/20
BOOKBINDING AREA
If BF is High, internal operation is in progress and shall wait until BF is to be
Low, which by then the next instruction can be performed. In this instruction
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
In case of DDRAM read operation,cursor shift instruction plays the same role as DDRAM
address set instruction,it also transfers RAM data to output data register.
After read operation,address counter is automatically increased/decreased by 1 according
to the entry mode.
After CGRAM read operation,display shift may not be executed correctly.
Note:In case of RAM write operation,AC is increased/decreased by 1 as in read operation.
At this time,AC indicates the next address position, but only the previous data can be read
by the read instruction.
13. RELATIONSHIP BETWEEN CHARACTER CODE AND CGRAM
14. DISPLAY DATA RAM(DDRAM)
DDRAM stores display data of maximum 80x8 bits(80 characters).
DDRAM address is set in the address counter(AC) as a hexadecimal number
MSB LSB
Character code CGRAM Address CGRAM Data
D7 D6 D5 D4 D3 D2 D1 D0 A5 A4 A3 A2 A1 A0 P7 P6 P5 P4 P3 P2 P1 P0
Pattern
number
0000x000 000 000
00
01
01
10
10
11
11
1
0
1
0
1
0
1
xxx0111
0
xxx10001
xxx10001
xxx11111
xxx10001
xxx10001
xxx10001
xxx00000
pattern 1
0 000x111 000 00
00
01
01
10
10
11
11
0
1
0
1
0
1
0
1
xxx10001
xxx10001
xxx10001
xxx11111
xxx10001
xxx10001
xxx10001
xxx00000
pattern8
AC6 AC5 AC4 AC3 AC2 AC1 AC0
PRODUCT
SPEC.
MODE NO. PAGE 15/20
BOOKBINDING AREA
PRODUCT
SPEC.
MODE NO. PAGE 16/20
BOOKBINDING AREA
15. INITIALIZATION
15.1 8-bit interface mode (Condition: fosc = 270KHZ)
Power On
Wait time > 15 ms
after Vdd > 4.5V
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
00 0011XXXX
Wait time > 4.1 ms
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
00 0011XXXX
Wait time > 100 s
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
00 0011XXXX
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
00 0011NFXX
00 00001000
00 00000001
00 000001I/DS
Initialization Ends
Wait time > 40 ms
After Vdd > 2.7V
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF can be checked after the following instructions.
Function set ( Interface is 8 bits length.
Specify the number of display lines and
character font. )
The number of display lines and character
font cannot be changed afterwards.
Display off
Display clear
Entry mode set
()
PRODUCT
SPEC.
MODE NO. PAGE 17/20
BOOKBINDING AREA
Power On
Wait time > 15 ms
after Vdd > 4.5V
Wait time > 4.1 ms
Wait time > 100 s
Initialization Ends
RS R/W DB7 DB6 DB5 DB4
00 0010
00 0010
RS R/W DB7 DB6 DB5 DB4
00 0011
Wait time > 40 ms
After Vdd > 2.7V
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF cannot be checked before this instruction.
Function set ( Interface is 8 bits length. )
BF can be checked after the following instructions.
Function set ( Set interface to be 4 bits length.)
Interface is 8 bits length.
The number of display lines and character
font cannot be changed afterwards.
Display off
Display clear
Entry mode set
RS R/W DB7 DB6 DB5 DB4
00 0011
RS R/W DB7 DB6 DB5 DB4
00 0011
00 NFXX
00 0000
00 1000
00 0000
00 0001
00 0000
0 0 0 1 I/D S
Function set ( Interface is 4 bits length.
Specify the number of the display lines
and character font.)
()
15.2 4-bit interface mode (Condition: fosc = 270KHZ)
FDCC1601E-FLYYBW-51LK
PRODUCT
SPEC.
MODE NO. PAGE 18/20
BOOKBINDING AREA
If Interface Data Is 8-bits Long If Interface Data Is 4-bit Long
Data transfer is made through all 8 bus lines from
DB0 to DB7
Data transfer is accomplished through 4 bus lines
from DB4 to DB7.(while the rest of 4 bus lines from
DB0 toDB3 are not used.)
Data transfer is completed when 4-bits of data is
transferred twice.(upper 4-bits of data, then lower
4-bits of data.)
Features
1. Interface to an 8-bit or 4-bit MPU is available.
2. 192 types of alphanumeric, symbols and special characters can be displayed with the
built - in character generator (ROM).
3. Other preferred characters can be displayed by character generator (RAM).
4. Various instructions may be programmed.
Clear display
Cursor at home
On/Off cursor
Blink character
Shift display
Shift cursor
Read/Write display data .etc.
5. Compact and light weight design which can easily be integrated into end products.
6. Single power supply +5V drive (except for extended temperature type).
7. Low power consumption.
16.INTERFACE TO MPU
RS
R/W
E
Internal
DB7
Internal Operation
Busy
No
Data
Busy flag
Check
Instruction
Write
Busy flag
Check
Busy flag
Check Instruction
Write
Busy Busy
DB4-DB7
RS
E
LCD Unit
R/W
4
RS
R/W
E
Internal
DB7
Internal Operation
Busy
Busy flag
Check
Instruction
Write
Busy flag
Check
Busy
D15
D14
D13
R10-R13
HMCS43C
Note: IR7,IR3: Instruction 7th bit,3rd bit
Ac3: Address Counter 3rd bit
Instruction
Write
Ac3Ac3
IR7 IR3 D7 D3
INTERFACE TO 8-BIT MPU INTERFACE TO 4-BIT MPU
A
B
C
G2A
G2B
G
1K
200
DB0-DB7
RS
E
LCD Unit
R/W
D0-D7
A0
A4
A5
A6
A7
MI
IORQ
RD
Z80
LS 138
Y1
FDCC1601E-FLYYBW-51LK
PRODUCT
SPEC.
MODE NO. PAGE 19/20
BOOKBINDING AREA
17. STANDARD FONT MAP
FDCC1601E-FLYYBW-51LK
17. STANDARD FONT MAP
LLLL LLLH LLHL LLHH LHLL LHLH LHHL LHHH HLLL HLLH HLHL HLHH HHLL HHLH HHHL HHHH
LLLL
LLLH
LLHL
LLHH
LHLL
LHLH
LHHL
LHHH
HLLL
HLLH
HLHL
HLHH
HHLL
HHLH
HHHL
HHHH
CG
RAM
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Upper
4bit
Lower
4bit
Anti - static Bag
FORDATA
LCD Module
BOX
CARTON
18. PACKING DETAIL
WITH LED BKL
45 PCS/BOX
10 BOXES/CARTON
450 PCS/CARTON
18.00 KGS/CTN(G.W.)
0.07 M /CARTON
3
WITHOUT LED BKL
45 PCS/BOX
10 BOXES/CARTON
450 PCS/CARTON
16.00 KGS/CTN(G.W.)
0.07 M /CARTON
3
NOTE
1. The weight is estimated for reference only.
2. Packing detail may be changed without notice.
PRODUCT
SPEC.
MODE NO. PAGE 20/20.
BOOKBINDING AREA