UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag Ultra Precision Metal Film Leaded Resistors FEATURES * Exceptional low TCR: 2 ppm/K to 10 ppm/K * Super tight tolerance: 0.01 % to 0.25 % * Exceptional overall stability: class 0.02 * Wide resistance range: 22 to 1 M * Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 DESCRIPTION APPLICATIONS UXA 0204, UXB 0207, and UXE 0414 high precision leaded thin film resistors combine the proven reliability of the professional products with an exceptional level of precision and stability. Therefore they are perfectly suited for applications in the fields of precision test and measuring equipment and particularly for the design of calibration references and standards. * Precision test and measuring equipment * Design of calibration references and standards TECHNICAL SPECIFICATIONS DESCRIPTION UXA 0204 UXB 0207 UXE 0414 0204 0207 0414 A B D 22 to 221 k 10 to 1 M 22 to 511 k 0.25 %; 0.1 %; 0.05 %; 0.01 % 0.25 %; 0.1 %; 0.05 %; 0.01 % 0.1 %; 0.05 % 10 ppm/K; 5 ppm/K; 2 ppm/K 10 ppm/K; 5 ppm/K; 2 ppm/K 10 ppm/K; 5 ppm/K P85 0.05 W 0.125 W 0.25 W P70 0.1 W 0.25 W 0.5 W 200 V 250 V 300 V DIN size CECC size Resistance range Resistance tolerance Temperature coefficient Rated dissipation: Operating voltage, Umax. AC/DC Operating temperature range (1) -20 C to 125 C Peak permissible film temperature (1) 125 C Insulation voltage: 1 min.; Uins 300 V 500 V 800 V Continuous 75 V 75 V 75 V 100 to 100 k 100 to 250 k 100 to 100 k Max. resistance change at P70 for resistance range, R/R max., after: 2000 h Max. resistance change at P85 for resistance range, R/R max., after: 1000 h Failure rate: FITobserved Revision: 07-Mar-16 0.05 % 0.05 % 0.05 % 100 to 100 k 100 to 250 k 100 to 100 k 0.02 % 0.02 % 0.02 % 8000 h 0.04 % 0.04 % 0.04 % 225 000 h 0.12 % 0.12 % 0.12 % 0.1 x 10-9/h Document Number: 28726 1 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag TEMPERATURE COEFFICIENT AND RESISTANCE RANGE TYPE TCR 10 ppm/K UXA 0204 5 ppm/K 2 ppm/K (3) 10 ppm/K UXB 0207 5 ppm/K 2 ppm/K (3) 10 ppm/K UXE 0414 5 ppm/K TOLERANCE RESISTANCE (1)(2)(3) E-SERIES 0.25 % 22 to 221 k E192 0.1 % 43 to 221 k E192 0.05 % 100 to 180 k E192 0.01 % 200 to 150 k E192 0.25 % 47 to 150 k E192 0.1 % 47 to 150 k E192 0.05 % 100 to 150 k E192 0.01 % 200 to 150 k E192 0.25 % 100 to 100 k E192 0.1 % 100 to 100 k E192 0.05 % 150 to 100 k E192 0.01 % 200 to 100 k E192 0.25 % 10 to 1 M E192 0.1 % 10 to 1 M E192 0.05 % 24 to 301 k E192 0.01 % 24 to 301 k E192 0.25 % 10 to 1 M E192 0.1 % 10 to 1 M E192 0.05 % 24 to 221 k E192 0.01 % 24 to 221 k E192 0.25 % 100 to 150 k E192 0.1 % 100 to 150 k E192 0.05 % 150 to 150 k E192 0.01 % 200 to 150 k E192 0.1 % 22 to 511 k E192 0.05 % 100 to 301 k E192 0.1 % 47 to 301 k E192 0.05 % 100 to 301 k E192 Notes (1) Resistance values to be selected from the E192 series, for other values please contact the factory. (2) TCR 10 and TCR 05 are specified over the temperature range from -20 C to +85 C. (3) TCR 02 is specified over the temperature range 0 C to +60 C. Revision: 07-Mar-16 Document Number: 28726 2 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag PART NUMBER AND PRODUCT DESCRIPTION PART NUMBER: UXB02070F1001AC100 U X B 0 2 0 7 0 F 1 0 0 1 A C 1 0 0 TYPE / SIZE VARIANT TCR VALUE TOLERANCE PACKAGING SPECIAL UXA0204 UXB0207 UXE0414 0 = neutral H = 2 ppm/K G = 5 ppm/K F = 10 ppm/K 3 digit value 1 digit multiplier Multiplier 9 = *10-1 0 = *100 1 = *101 2 = *102 3 = *103 4 = *104 T = 0.01 % A = 0.05 % B = 0.1 % C = 0.25 % C1 CU R1 R2 RP Up to 2 digits 00 = standard PRODUCT DESCRIPTION: UXB 0207-10 0.05 % C1 1K0 UXB 0207 10 0.05 % C1 1K0 TYPE SIZE TCR TOLERANCE PACKAGING (1) RESISTANCE VALUE UXA UXB UXE 0204 0207 0414 2 ppm/K 5 ppm/K 10 ppm/K 0.01 % 0.05 % 0.1 % 0.25 % C1 CU R1 R2 RP 1K0 = 1.0 47K = 47 k 50R5 = 50.5 Note * The part number is shown to facilitate the introduction of a unified part numbering system. PACKAGING TYPE / SIZE UXA 0204 UXB 0207 UXE 0414 CODE QUANTITY PACKAGING STYLE WIDTH PITCH DIMENSIONS CU 100 C1 1000 Taped acc. to IEC 60286-1 fan-folded in a box 53 mm 5 mm 74 mm x 42 mm x 184 mm Taped acc. to IEC 60286-1 fan-folded in a box 53 mm 5 mm 75 mm x 40 mm x 187 mm Taped acc. to IEC 60286-1 on a reel 53 mm 5 mm Taped acc. to IEC 60286-1 fan-folded in a box 53 mm 5 mm 47 mm x 84 mm x 374 mm Taped acc. to IEC 60286-1 on a reel 53 mm 5 mm 315 mm x 80 mm x 90 mm CU 100 C1 1000 R1 1000 RP 5000 CU 100 C1 1000 R2 2500 315 mm x 70 mm x 80 mm 315 mm x 76 mm x 86 mm SCRIPT MARKING - Printed resistance value and letter coding for TCR and tolerance RESISTANCE VALUE Clear text code for value Revision: 07-Mar-16 TOL. (%) LETTER CODE TCR (ppm/K) LETTER CODE 0.25 C 10 B 0.1 B 5 A 0.05 A 2 T 0.01 T - - Document Number: 28726 3 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com DESCRIPTION Production is strictly controlled and follows an extensive set of instructions established for reproducibility. A homogeneous film of metal alloy is deposited on a high grade ceramic body (85 % Al2O3) and conditioned to achieve the desired temperature coefficient. Nickel plated steel termination caps are firmly pressed on the metallized rods. Special laser devices are used repeatedly to achieve the target value by slowly and smoothly cutting a helical groove in the resistive layer without damaging the ceramics. A further conditioning is applied in order to stabilise the trimming result. Connecting wires of electrolytic copper plated with pure tin are welded to the termination caps. The resistors are covered by protective coating designed for electrical, mechanical and climatic protection. The terminations receive a final pure tin on nickel plating. Script marking designates the resistance value plus coded TCR and tolerance. The result of the determined production is verified by an accelerated aging (burn-in) and extensive testing procedure performed on 100 % of the individual resistors. Only accepted products are stuck directly on the adhesive tapes in accordance with IEC 60286-1. ASSEMBLY The resistors are suitable for processing on automatic insertion equipment and cutting and bending machines. Excellent solderability is proven, even after extended storage. They are suitable for automatic soldering using wave or dipping. The encapsulation is resistant to all cleaning solvents commonly used in the electronics industry, including alcohols, esters and aqueous solutions. The suitability of conformal coatings, if applied, shall be qualified by appropriate means to ensure the long-term stability of the whole system. The resistors are completely lead (Pb)-free, the pure tin plating provides compatibility with lead (Pb)-free and lead-containing soldering processes. The immunity of the plating against tin whisker growth has been proven under extensive testing. Vishay Beyschlag MATERIALS Vishay acknowledges the following systems for the regulation of hazardous substances: * IEC 62474, Material Declaration for Products of and for the Electrotechnical Industry, with the list of declarable substances given therein (1) * The Global Automotive Declarable Substance List (GADSL) (2) * The REACH regulation (1907/2006/EC) and the related list of substances with very high concern (SVHC) (3) for its supply chain The products do not contain any of the banned substances as per IEC 62474, GADSL, or the SVHC list, see www.vishay.com/how/leadfree. Hence the products fully comply with the following directives: * 2000/53/EC End-of-Life Vehicle Directive (ELV) and Annex II (ELV II) * 2011/65/EU Restriction of the Use of Hazardous Substances Directive (RoHS) with amendment 2015/863/EU * 2012/19/EU Waste Electrical and Electronic Equipment Directive (WEEE) Vishay pursues the elimination of conflict minerals from its supply chain, see the Conflict Minerals Policy at www.vishay.com/doc?49037. APPROVALS Where applicable, the resistors are tested in accordance to EN 60115-1 and EN 140100. Vishay Beyschlag has achieved "Approval of Manufacturer" in accordance with IEC QC 001002-3, clause 2. The release certificate for "Technology Approval Schedule" in accordance with CECC 240001 based on IEC QC 001002-3, clause 6 is granted for the Vishay Beyschlag manufacturing process. Notes (1) The IEC 62474 list of declarable substances is maintained in a dedicated database, which is available at http://std.iec.ch/iec62474. (2) The Global Automotive Declarable Substance List (GADSL) is maintained by the American Chemistry Council and available at www.gadsl.org. (3) The SVHC list is maintained by the European Chemical Agency (ECHA) and available at http://echa.europa.eu/candidate-list-table. Revision: 07-Mar-16 Document Number: 28726 4 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag Power Dissipation P FUNCTIONAL DESCRIPTION UXE 0414 UXB 0207 UXA 0204 0.2 W 0.1 0 50 0 - 50 85 100 150 C Ambient Temperature amb Temperature Rise Tr Derating - Standard Operation UXA 0204 UXB 0207 UXE 0414 60 K 40 20 0 0 0.1 0.2 0.3 0.4 W 0.5 Load P Rise of the surface temperature. Current Noise A 1 Temperature Rise 1 uV/V 0.1 UXA 0204 UXB 0207 UXE 0401 0.01 1 k 10 k 100 k 1 M Resistance Value R Current Noise A1 in accordance with IEC 60195 Revision: 07-Mar-16 Document Number: 28726 5 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag TESTS AND REQUIREMENTS Essentially all tests are carried out in accordance with the following specifications: Unless otherwise specified the following values apply: * EN 60115-1, Generic specification (includes tests) * Relative humidity: 45 % to 75 % The Test Procedures and Requirements table contains only the most important tests. For the full test schedule refer to the documents listed above. The testing also covers most of the requirements specified by EIA/IS-703 and JIS-C-5202. * Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar). The tests are carried out in accordance with IEC 60068-2-xx test method and under standard atmospheric conditions in accordance with IEC 60068-1, 5.3. Climatic category -20 C / +125 C / 56 days (rated temperature range: Lower category temperature, upper category temperature; damp heat, long term, 56 days) is valid. * Temperature: 15 C to 35 C For testing the components are mounted on a test board in accordance with IEC 60115-1, 4.31 unless otherwise specified. In the Test Procedures and Requirements table only the tests and requirements are listed with reference to the relevant clauses of IEC 60115-1 and IEC 60068-2-xx test method. A short description of the test procedure is also given. TEST PROCEDURES AND REQUIREMENTS PROCEDURE REQUIREMENTS PERMISSIBLE CHANGE (R) Stability for product types: IEC 60115-1 CLAUSE IEC 60068-2 TEST METHOD UXA 0204 100 to 100 k 22 to < 100 > 100 k to 221 k - UXB 0207 100 to 250 k 40.2 to < 100 > 250 k to 301 k 10 to < 40.2 > 301 k to 1 M UXE 0414 100 to 100 k 22 to < 100 > 100 k to 511 k - TEST 4.5 - Resistance - 0.25 %; 0.1 %; 0.05 %; 0.01 % 4.7 - Voltage proof URMS = Uins; 60 s No flashover or breakdown At (20 / -20 / 20) C and (20 / 85 / 20) C 10 ppm/K; 5 ppm/K - Temperature coefficient At (20 / 0 / 20) C and (20 / 60 / 20) C 2 ppm/K 4.8 4.13 - Short time overload Room temperature; U = 2.5 x P 70 x R or U = 2 x Umax.; 5 s (0.01 % R + 0.01 ) (0.01 % R + 0.01 ) (0.02 % R + 0.01 ) 4.16 21 (Ua1) 21 (Ub) 21 (Uc) Robustness of terminations Tensile, bending, and torsion (0.01 % R + 0.01 ) (0.01 % R + 0.01 ) (0.02 % R + 0.01 ) at +235 C; 2 s; solder bath method; SnPb40 4.17 20 (Ta) Solderability Good tinning (> 95 % covered); no damage at +245 C; 3 s; solder bath method; SnAg3Cu0.5 4.18.2 20 (Tb) Resistance to soldering heat Unmounted components; (260 5) C; (10 1) s (0.01 % R + 0.01 ) (0.01 % R + 0.01 ) (0.02 % R + 0.01 ) 4.19 14 (Na) Rapid change of temperature 30 min at -55 C 30 min at +125 C 5 cycles (0.01 % R + 0.01 ) (0.01 % R + 0.01 ) (0.02 % R + 0.01 ) 4.22 6 (B4) Vibration 10 sweep cycles per direction; 10 Hz to 2000 Hz 1.5 mm or 200 m/s2 (0.01 % R + 0.01 ) (0.01 % R + 0.01 ) (0.02 % R + 0.01 ) Revision: 07-Mar-16 Document Number: 28726 6 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag TEST PROCEDURES AND REQUIREMENTS PROCEDURE REQUIREMENTS PERMISSIBLE CHANGE (R) Stability for product types: IEC 60115-1 CLAUSE IEC 60068-2 TEST METHOD 100 to 100 k 22 to < 100 > 100 k to 221 k - UXB 0207 100 to 250 k 40.2 to < 100 > 250 k to 301 k 10 to < 40.2 > 301 k to 1 M UXE 0414 100 to 100 k 22 to < 100 > 100 k to 511 k - Climatic sequence: 4.23 4.23.2 UXA 0204 TEST 2 (Ba) Dry heat 125 C; 16 h 4.23.3 30 (Db) Damp heat, cyclic 55 C; 24 h; 90 % to 100 % RH; 1 cycle 4.23.4 1 (Aa) Cold -55 C; 2 h 4.23.5 13 (M) Low air pressure 8.5 kPa; 2 h; 15 C to 35 C 4.23.6 30 (Db) Damp heat, cyclic 55 C; 5 days; 95 % to 100 % RH; 5 cycles DC load apply rated power for 1 min 78 (Cab) Damp heat, steady state (40 2) C; 56 days; (93 3) % RH 4.23.7 4.24 4.25.1 4.25.3 4.29 - Endurance (at 70 C) (0.04 % R + 0.01 ); (0.05 % R + 0.01 ); (0.06 % R + 0.01 ); no visible damage no visible damage no visible damage (0.04 % R + 0.01 ) (0.05 % R + 0.01 ) (0.06 % R + 0.01 ) U = P 70 x R or U = Umax.; 1.5 h on; 0.5 h off 70 C; 2000 h (0.05 % R + 0.01 ) (0.05 % R + 0.01 ) (0.05 % R + 0.01 ) 85 C; 1000 h (0.02 % R + 0.01 ) (0.03 % R + 0.01 ) (0.04 % R + 0.01 ) 85 C; 8000 h (0.04 % R + 0.01 ) (0.06 % R + 0.01 ) (0.08 % R + 0.01 ) - Endurance at upper category temperature 125 C; 1000 h (0.04 % R + 0.01 ) (0.06 % R + 0.01 ) (0.08 % R + 0.01 ) 45 (XA) Component solvent resistance Isopropyl alcohol (used in industrial application) +23 C; toothbrush method Marking legible; no visible damage DIMENSIONS D d L I M DIMENSIONS - Leaded resistor types, mass, and relevant physical dimensions Dmax. (mm) Lmax. (mm) dnom. (mm) Imin. (mm) Mmin. (mm) MASS (mg) UXA 0204 1.6 3.6 0.5 29.0 5.0 125 UXB 0207 2.5 6.3 0.6 28.0 7.5 220 UXE 0414 4.0 11.9 0.8 31.0 15.0 750 TYPE Revision: 07-Mar-16 Document Number: 28726 7 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 UXA 0204, UXB 0207, UXE 0414 www.vishay.com Vishay Beyschlag 12NC INFORMATION FOR HISTORICAL CODING REFERENCE * The resistors have a 12-digit part number starting with 2312. * The subsequent 4 digits indicate the resistor type, specification and packaging; see the 12NC Part Number table. * The remaining 4 digits indicate the resistance value: - The first 3 digits indicate the resistance value. - The last digit indicates the resistance decade in accordance with the 12NC Indicating Resistance Decade table. Last Digit of 12NC Indicating Resistance Decade RESISTANCE DECADE 10 to 99.9 100 to 999 1 k to 9.99 k 10 k to 99.9 k 100 k to 999 k LAST DIGIT 9 1 2 3 4 12NC Example The part number of a UXA 0204 resistor, value 47 k and TCR 10 with 0.1 % tolerance, supplied on bandolier in a box of 1000 units is: 2312 662 34703. 12NC PART NUMBER - Resistor type and packaging DESCRIPTION TYPE TCR 10 ppm/K TOL. 0.25 % 0.1 % 0.05 % 0.01 % (1) UXA 0204 5 ppm/K 0.25 % 0.1 % 0.05 % 0.01 % (1) 2 ppm/K 0.25 % 0.1 % 0.05 % 0.01 % (1) 10 ppm/K 0.25 % 0.1 % 0.05 % 0.01 % (1) UXB 0207 5 ppm/K 0.25 % 0.1 % 0.05 % 0.01 % (1) 2 ppm/K 0.25 % 0.1 % 0.05 % 0.01 % (1) 10 ppm/K 0.1 % 0.05 % (1) UXE 0414 5 ppm/K 0.1 % 0.05 % (1) BANDOLIER IN BOX CU 100 units 562 2.... 562 3.... 562 4.... 562 7.... 562 91... 563 2.... 563 3.... 563 4.... 563 7.... 563 91... 564 2.... 564 3.... 564 4.... 564 7.... 564 91... 572 2.... 572 3.... 572 4.... 572 7.... 572 91... 573 2.... 573 3.... 573 4.... 573 7.... 573 91... 574 2.... 574 3.... 574 4.... 574 7.... 574 91... 592 3.... 592 4.... 592 91... 593 3.... 593 4.... 593 91... BANDOLIER IN BOX C1 1000 units 662 2.... 662 3.... 662 4.... 662 7.... 662 91... 663 2.... 663 3.... 663 4.... 663 7.... 663 91... 664 2.... 664 3.... 664 4.... 664 7.... 664 91... 672 2.... 672 3.... 672 4.... 672 7.... 672 91... 673 2.... 673 3.... 673 4.... 673 7.... 673 91.... 674 2.... 674 3.... 674 4.... 674 7.... 674 91... 692 3.... 692 4.... 692 91... 693 3.... 693 4.... 693 91... 2312 ... ..... BANDOLIER ON REEL R1 1000 units 462 2.... 462 3.... 462 4.... 462 7.... 462 91... 463 2.... 463 3.... 463 4.... 463 7.... 463 91... 464 2.... 464 3.... 464 4.... 464 7.... 464 91... 472 2.... 472 3.... 472 4.... 472 7.... 472 91... 473 2.... 473 3.... 473 4.... 473 7.... 473 91... 474 2.... 474 3.... 474 4.... 474 7.... 474 91... - BANDOLIER ON REEL R2 2500 units 597 3.... 597 4.... 597 91... 598 3.... 598 4.... 598 91... BANDOLIER ON REEL RP 5000 units 577 2.... 577 3.... 577 4.... 577 7.... 577 91... 578 2.... 578 3.... 578 4.... 578 7.... 578 91... 579 2.... 579 3.... 579 4.... 579 7.... 579 91... - Note (1) Readable 12NC coding of resistance values is restricted to values with three significant digits. For resistance values with more than three significant digits, a non readable sequential number will be issued by the factory for each requested combination of resistance value and tolerance. Revision: 07-Mar-16 Document Number: 28726 8 For technical questions, contact: filmresistorsleaded@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. (c) 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Vishay: UXAB20K000B1T UXBA10K000B1T UXBB100R00B1T UXBB10K000A1T UXBB12K000A1T UXBB15K000A1T UXBB15K990A1T UXBB1K1000B1T UXBB1K2000T1T UXBB200K00A1T UXBB4K9900A1T UXBB8K0600A1T UXEB100K00A1A UXB02075H4003FR100 UXB02070F1003BC100 UXB02070F1201TR100 UXB02070F1002BR100 UXB02070F1002AR100 UXB02070F4991AR100 UXE04140F1003AC100 UXB02070F8061AR100 UXB02070F1202AR100 UXB02070F1101BR100 UXB02070F1000BR100 UXB02070F1502AR100 UXB02070F2003AR100