UTC MCR100 SCR
UTC UNISONIC TECHNOLOGIES CO., LTD. 1
PLASTIC SILICON
CONTROLLED RECTIFIERS
DESCRIPTION
PNPN devices designed for high volume, line-
powered consumer applications such as relay and
lamp drivers, small motor controls, gate drivers for
larger thyristors, and sensing and detection circuits.
Supplied in an inexpensive plastic TO-92 package
which isreladily adaptable for use in automatic
insertion equipment.
DESCRIPTION
*Sensitive Gate Trigger Current - 200µA Maximum
*Low Reverse and forward Blocking Current - 100µA
Maximum, Tc=125°C
*Low Holding Current 5mA Maximum
*Glass-Passivated Surface for Reliability and
Uniformity
*Also Available with TO-5 or TO-18 Lead Form
TO-92
1
1:CATHODE 2:GATE 3:ANODE
THERMAL CHARACTERISTICS
PARAMETER SYMBOL MAX UNIT
Thermal Resistance, Junction to Case R£cJC 75 °C/W
Thermal Resistance, Junction to Ambient R£cJA 200 °C/W
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MAX UNIT
Peak Reverse Blocking Voltage MCR100-4
MCR100-6
MCR100-8
VRRM 200
400
600
V
Forward Current RMS IT(RMS) 0.8 A
Peak Forward Surge Current, TA=25°C
(1/2 cycle, Sine Wave, 60Hz) ITSM 10 A
Circuit Fusing Considerations, TA=25°C
(t=1 to 8.3 ms) I2t0.415 A2s
Peak Gate Power Forward, TA=25°CPGM 0.1 W
Average Gate Power Forward, TA=25°CPGF(AV) 0.01 W
Peak Gate Current Forward, TA=25°C(300µs, 120PPS) IGFM 1A
Peak Gate Voltage - Reverse VGRM 5V
Operating Junction Temperature Range @ Rated VRRM and
VDRM Tj -65 to +110 °C
Storage Temperature Range Tstg -40 to +150 °C
Lead Solder Temperature
(<1/16 from case, 10 s max) 230 °C
UTC MCR100 SCR
UTC UNISONIC TECHNOLOGIES CO., LTD. 2
ELECTRICAL CHARACTERISTICS (Tj=25°C unless otherwise stated)
PARAMETER SYMBOL MIN MAX UNIT
Peak Forward Blocking Voltage
(Tc=125°C) MCR100-4
MCR100-6
MCR100-8
VDRM 200
400
600
V
Peak Forward or Reverse Blocking Current
(Rated VDRM or VRRM) Tc=25°C
Tc=125°C
IDRM,IRRM 10
100 µA
µA
Forward On Voltage (Note1)
(ITM=1A peak @ TA=25°C) VTM 1.7 V
Gate Trigger Current (continuous dc) (Note 2) Tc=25 °C
(Anode Voltage=7Vdc, RL=100)IGT 200 µA
Gate Trigger Voltage (continuous dc) Tc=25 °C
(Anode voltage=7Vdc, RL=100)Tc=-40 °C
(Anode Voltage=Rated VDRM, RL=100)Tc=125 °C
VGT
0.1
0.8
1.2 V
Holding Current Tc=25 °C
(Anode Voltage=7Vdc, initiating current=20mA) Tc=-40 °CIH 5
10 mA
Notes: 1. Forward current applied for 1 ms maximum duration, duty cycle <=1%
2. RGK current is not included in measurement.