Embedded Power for Business-Critical Continuity MP Series Rev. 12.12.2013 MP Series 1 of 6 MicroMP 1U Multi Output Up to 1200 Watts Total Power: Up to 1200 Watts Input Voltage: 85 - 264 Vac 120-300 Vdc # of Outputs: Up to 12 Special Features * * * * * * * * * * * * * * * Full Medical EN60601 approval PMBus High efficiency Current limit modification (foldback or constant current) High power density. uMP4: 10.8 W/cu-in uMP1: 15.1 W/cu-in Intelligent fan (speed control/fault status) Downloadable GUI from website uP controlled PFC input with active inrush protection Optional conformal coating Industrial temp range (-40 C to 70 C) No preload required Industrial shock/vibration (> 50G's) Low cost IEC or terminal block input Low profile 1U size Electrical Specifications MP4C shown Input Input range: 85 - 264 Vac, 120 - 350 Vdc (limited to 250 Vac/300 Vdc in medical apps) Frequency: 47 - 440 Hz Inrush current: 40 A peak max. (soft start) Efficiency: Up to 91% @ full case load Power Factor: 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz) Turn-on time: AC on 2 sec for uMP1 and 1.5 sec for uMP4, inhibit/enable 250 ms typical EMI filter: CISPR 22/EN55022 Level "B" Leakage current: 300 A Max. @ 240 VAC Radiated EMI: CISPR 22/EN55022 Level "B" Holdover storage: 16.7 ms minimum (independent of input Vac, 0 C to 50 C)) AC OK: Signal goes low indicating loss of AC input. Hold up = Full cycle ride thru (50 Hz) Harmonic distortion: Meets EN61000-3-2 Isolation: Meets EN60950 and EN60601 Global Inhibit/Enable: TTL, Logic "1" and Logic "0"; fan off when unit is inhibited Input fuse (internal): uMP1: 16 A/250 V TLAG, uMP4: 10 A / 250 V. (both lines fused) Warranty: 2 years Environmental Specifications Operating temperature: Safety * * * * UL CSA VDE BABT * CB * CE * CCC UL60950/UL60601-1 CSA22.2 No. 234 Level 5 EN60950/EN60601-1 Compliance to EN60950/EN60601 BS7002 Certificate and report Mark to LVD Approved -40 to 70 C ambient. Derate each output 2.5% per degree from 50 C to 70 C. ( -20 C start up). Meets full spec after 1/2 load. 10 min warm-up Storage temperature: -40 C to 85 C Electromagnetic susceptibility: Designed to meet EN61000-4; -3, -5, -6, -11 Level 3, Level 4 for -2, -4 Humidity: Operating; non-condensing 10% to 95% RH Vibration: MIL-STD-810E MTBF demonstrated: > 350,000 hours at full load, one uMP4 case + two modules, Telcordia SR-332 calculated MTBF Altitude: Up to 10k feet; derate linear to 50% from 10k-30k feet Embedded Power for Business-Critical Continuity Rev. 12.12.2013 MP Series 2 of 6 Output Factory set point accuracy: 1% Margining: 3 - 7% nominal analog (single output module only) Overall regulation: 0.4% or 30 mV which ever is greater. Ripple: RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz Dynamic response: < 5% or 250 mV, with 50% step load Recovery time: To within 1% in < 300 sec Reverse voltage protection: 100% of rated output current All outputs disabled when internal temp exceeds safe operating range. Thermal protection: (OTP) Remote sense: Single wire parallel: DC OK: Minimum load: Housekeeping standby: p to 0.5 V total drop (not available on triple output module) U Current share to within 5% of total rated current 5% of nominal. Not required 5 Vdc @ 1.0 A max. present whenever AC input is applied Module inhibit: Output/Output isolation: Logic - output on with low or open. Different logic options available > 1 Megohm, 500 V Vout Full load (A) OVP trip max (V) OCP trip typ (Iout%) SCP trip max (Iout%) Overshoot (max mV) Peak Deviation (max mV) 40 40 40 2.00 V 5.96 V 6.31 V 130% 130% 130% 160% 160% 160% 150 250 250 250 250 250 36 36 30 5.76 V 9.00 V 10.80 V 130% 130% 130% 160% 160% 160% 250 250 300 250 250 300 25 20 16 10.80 V 15.60 V 19.50 V 130% 130% 130% 160% 160% 160% 300 600 750 300 600 750 13 10 8 15.60 V 31.20 V 39.00 V 130% 130% 130% 160% 160% 160% 600 1200 1500 600 1200 1500 7 5 4 36.40 V 62.40 V 78.00 V 130% 130% 130% 200% 160% 200% 1400 2400 3000 1400 2400 3000 3V3 Module 0.9 3.3 3.6 5 V Module 3.2 5 6 12 V Module 6 12 15 24 V Module 12 24 30 48 V Module 28 48 60 Case Line-Up Case Max Output MP4 - 4 Slot 400 W - 600 W MP1 - 6 Slot 1000 W - 1200 W Dimensions 256.90.8 x 88.90.5 x 40.00.7 (10.11" x 3.5" x 1.57") 256.90.8 x 1270.5 x 40.00.5 (10.11" x 5" x 1.57") Connections Max Current Amps IEC/Terminal Block 9.91 IEC/Terminal Block 13.87 Output Module Line-Up Output Range (Vdc) 0.9 - 3.6 3.2 - 6.0 6.0 - 15.0 12.0 - 30.0 28.0 - 54.0 5.0 - 28.0 5.0 - 28.0 Max Current (Amps) Max Power (Watts) 40 36 25 13 7 4 4 144 180 240 240 240 96 96 Module Codes Standard Outputs A, B, C, D - 2, 2.2, 3, 3.3 E, F, G, H - 5, 5, 2, 5.5, 6 I, J, K, L, M, N - 8, 10, 11, 12, 14, 15 O, P, Q, R, S - 18, 20, 24, 28, 30 T, U, V, W, X, Y - 28, 30, 33, 36, 42, 48, 54, 60 Dual Output Module. Each output is rated to 96W (192 Watts total). Wide range is adjustable. Embedded Power for Business-Critical Continuity Rev. 12.12.2013 MP Series 3 of 6 Ordering Info Case Size MPXY - S2E - DER - DLL Module Codes S2 = 200 W Single O/P (1 slot) D = 96 W/96 W Dual O/P Common Ground (1 slot) I = 96 W/96 W Dual O/P Isolated Ground (1 slot) Case Size Single - Phase Input where X = 4 = 1.57" x 3.5" x 10"; 400 W - 600 W, 4 Slots 1 = 1.57" x 5" x 10"; 1000 W - 1200 W, 6 Slots Input Type where Y = T = Terminal Block C = IEC Connector, C14 B = IEC Connector, C16 Voltage Codes: See Voltage Code Table - 00 Case Option Codes First digit 0 - F = Parallel Code Code Slots in Parallel Code Slots in Parallel Code Slots in Parallel Code 1 1&2 6 1,2&3 B 1,2&3; 4&5 0 2 3 4 2&3 3&4 4&5 7 8 9 1,2,3&4 1,2,3,4&5 1,2,3,4,5&6 C D E 1,2,3&4; 5&6 1&2; 3&4; 5&6 1,2&3; 4,5&6 5 5&6 A 1&2; 3&4 F 2&3; 4&5 Standard Output Ratings Module Output Voltage Code Single Output ONE SLOT 240 Watts Max Dual Output ONE SLOT 192 Watts Max Module Identification S2 D = Dual Common Ground I = Dual Isolated Ground Output Module Line-Up A B C D E F G H I J K L M N O P Q R S T U V W X Y * For "I" codes only 2.0 V 2.2 V 3.0 V 3.3 V 5.0 V 5.2 V 5.5 V 6.0 V 8.0 V 10.0 V 11.0 V 12.0 V 14.0 V 15.0 V 18.0 V 20.0 V 24.0 V 28.0 V 30.0 V 33.0 V 36.0 V 42.0 V 48.0 V 54.0 V 60.0 V A Factory assigned for modified standards - ### Factory assigned for modified standards Slots in Parallel no module in parallel Application Notes (Only for Output Voltages 14.0V-24.0V) 1. Units should not be operated in parallel 2. In a single unit, parallel modules should not be individually inhibited 3.Total load capacitance should not exceed 2000uF Derating Curves - MP1 Voltage Codes Volts - Hardware Code Second digit 0 = No Options 1 = Reverse Air 3 = Global Enable 5 = Opt 1 + Opt 3 Parallel Codes Code Software Code Case Option Codes Module/Voltage/Option Codes Output Current V1 40.0 40.0 40.0 40.0 36.0 34.0 32.0 30.0 25.0 24.0 22.0 20.0 17.0 16.0 13.0 12.0 10.0 8.6 8.0 7 6.7 5.7 5.0 4.4 4.0 Output Current V1 V2 N/A N/A N/A 4.0* 4.0* 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.4 3.4 N/A N/A N/A N/A N/A N/A N/A Embedded Power for Business-Critical Continuity S2 Module MP4 (AC input on opposite side) S L O T S L O T S L O T S L O T 4 3 2 1 MP4 =4 available slots DC Output Control & Signals (Single output) J2 J1 Input 85-264 Vac 200-264 Vac 400 W max. 600 W max. 240 W MP1 (AC input on opposite side) S L O T 6 S L O T 5 S L O T 4 S L O T 3 S L O T 1 S L O T 2 Rev. 12.12.2013 MP Series 4 of 6 J2 1.00.25 V ADJ 5.30.5 J1 V+ Pin 1 2 3 4 5 6 7 8 9 10 Function No connection No connection Current share Module inhibit return Module ISO inhibit SCOM -RMT sense Margin Remote margin / V prog. +RMT sense 29.80.2 37.50.3 32.50.3 36.50.3 36.50.3 V- MP1 = 6 available slots Input 85-264 Vac 1000 W max. CAPS HEIGHT 4.50.3 12.5 MAX 3.0 MAX 200-264 Vac 1200 W max. 0.8 - 1.5 1.60.16 Pin Connectors Figure 1. AC Input AC Input Pin 1 2 3 IEC Connector Terminal Block PE N L 9 10 Mates with Landwin 2050S1000 Housing 2053T011V Pin or JST PHDR-10VS Housing JST SPHD-002T-P0.5 (28-24) JST SPHD-001T-P0.5 (26-22) Connector Kit Part No.: 70-841-023 PFC Input Connector (control & signals) Pin 1 2 3 4 5 6 7 8 9 Figure 2. Connector J1 & J2 1 2 J1 Function AC neutral AC line (hot) Chassis (earth) ground Function Input AC OK - "emitter" Input AC OK - "collector" Global DC OK - "emitter" Global DC OK - "collector" Spare Global inhibit/optional enable logic "1" Global inhibit/optional enable logic "0" Global inhibit/optional enable return +5 VSB housekeeping 10 +5 VSB housekeeping return J2 I2C Bus Output Connector Pin 1 2 3 4 5 6 7 8 9 10 Function 5 Vcc bus Serial data signal (SDA) Secondary return (COM) Serial clock signal (SCL) Address bit 2 (A2) No connection Address bit 1 (A1) No connection Address bit 0 (A0) No connection 1 2 130.01.5 9 10 Dual Module DC Output Control & Signals (Dual output) Pin 1 2 3 4 5 6 7 8 9 10 Function -RMT sense V2 +RMT sense V2 No connection Module inhibit rtn Module ISO inhibit SCOM -RMT sense V1 No connection No connection +RMT sense V1 Embedded Power for Business-Critical Continuity MP Series MP4 (400/600 Watts Max) Case Size: MP4: 10.11" x 3.5" x 1.57" (256.9mm x 88.9mm x 40.0mm) Weight: MP4 Case: 1.96 lbs * Single O/P: 0.22 lb. * Dual O/P: 0.16 lb. * Blank: 0.06 lb. Rev. 12.12.2013 MP Series 5 of 6 Forward Airflow Notes: 1. Input: IEC 60320 C13 (for IEC connector) Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4-0.5 Nm); Wire: 12-16 AWG; Wire Strip Length: 0.354" (9.0 mm) 2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts. Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD-002T-PO.5 (JST) pins. 3. Output Module Connectors: All single O/P modules are M4 x 10mm screws; Max. Torque: 6.94 to 8.68 lb-in (0.785 to 0.981 N-m). Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm); Control signal connector: Refer to Item 2. 4. Chassis Material: Steel with chemical film coating (conductive). 5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m) 6. All dimensions are in millimeters and inches, and are typical. Forward Airflow Embedded Power for Business-Critical Continuity MP Series MP1 (1000/1200 Watts Max) Case Size: MP1: 10.11" x 5" x 1.57" (256.9mm x 127mm x 40.0mm) Weight: MP1 Case: 2.78 lbs * Single O/P: 0.22 lb. Americas * Dual O/P: 0.16 lb. * Blank: 0.06 lb. 5810 Van Allen Way Rev. 12.12.2013 MP Series 6 of 6 Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com Forward Airflow While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Notes: 1. Input: IEC 60320 C13 (for IEC connector) Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4-0.5 Nm); Wire: 12-16 AWG; Wire Strip Length: 0.354" (9.0 mm) 2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD-002T-PO.5 (JST) pins. 3. Output Module Connectors: All single O/P modules are M4 x 10mm screws; Max. Torque: 6.94 to 8.68 lb-in (0.785 to 0.981 N-m). Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm); Control signal connector: Refer to Item 2. 4. Chassis Material: Steel with chemical film coating (conductive). 5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m) 6. All dimensions are in millimeters and inches, and are typical. Forward Airflow Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson and the Emerson Network Power logo are trademarks of Emerson Electric Co. (c)2012 Emerson Electric Co. All rights reserved.