1
Digital Fiber Sensors
E3X-DA-S
Stable Detection with Advanced Fiber
Sensors
A wide range of added value with standard models with one
input and two out puts, and ul tra-long-t erm APC models wit h an
APC life of approximately 20 years.
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in
this class even for low-reflective objects and large objects.
The E3X-DA0-S supports an EtherCAT Communications Unit or
CompoNet Communications Unit.
Ordering Information
Amplifier Units
Pre-wired Models and Wire-saving Connector Models [Dimensionspage 25]
A Wire-saving connector sold separately is required.
Communications Unit Connector Models (for EtherCAT and CompoNet) [Dimensionspage 27]
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Type Appearance Connecting
method Model Applicable wire-saving connector
(sold separately)
NPN output PNP output Type Model
Standard
models
Pre-wired
(2 m) E3X-DA21-S 2M E3X-DA51-S 2M --- ---
Wire-saving
connector E3X-DA7-S E3X-DA9-S
Master
connector E3X-CN21
Slave
connector E3X-CN22
Ultra-long-term
APC models
Pre-wired
(2 m) E3X-DA21R-S 2M E3X-DA51R-S 2M --- ---
Wire-saving
connector E3X-DA7R-S E3X-DA9R-S
Master
connector E3X-CN21
Slave
connector E3X-CN22
High-speed
response
models
Pre-wired
(2 m) E3X-DA21F-S 2M E3X-DA51F-S 2M --- ---
Wire-saving
connector E3X-DA7F-S E3X-DA9F-S
Master
connector E3X-CN11
Slave
connector E3X-CN12
Type Appearance Connecting method Model
Standard
model Connector for Communications
Unit E3X-DA0-S
E3X-DA-S
2
Wire-saving Connectors (sold separately) Protection stickers attached [Dimensionspage 27]
Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support
only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.
Accessories (sold separately)
Mounting Brackets [Dimensionspage 28] End Plate [Dimensionspage 28]
Product Overview
}: Strong point of the model {: Provided ---: Not provided
*1.2. Except for the response time, the Communications Unit Connector Models for EtherCAT and CompoNet have the same I/O, performance,
and functions as the Standard, Wire-saving Connector Models.
(The fastest response time of the Communications Units Connector Models is 250 µs.)
Type Appearance Cable length No. of conductors Model
Master connector
2 m
4E3X-CN21
Slave connector 2E3X-CN22
Master connector 3E3X-CN11
Slave connector 1E3X-CN12
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
Types Standard models1Ultra-long-term APC models High-speed response models
Connecting
method Pre-wired Wire-saving
connector Pre-wired Wire-saving
connector Pre-wired Wire-saving
connector
Item Models E3X-DA21-S
E3X-DA51-S E3X-DA7-S
E3X-DA9-S E3X-DA21R-S
E3X-DA51R-S E3X-DA7R-S
E3X-DA9R-S E3X-DA21F-S
E3X-DA51F-S E3X-DA7F-S
E3X-DA9F-S
Input/output External input 1 input --- 1 input --- ---
Output 2 outputs 1 output and 1 APC alarm output 1 output
Performance
Sensing distance
with E32-T11R 280 to 2,000 mm
(Depends on response time) 140 to 1,000 mm
(Depends on response time) 280 mm
(Only Super-high-speed Mode)
Sensing distance
with E32-D11R 100 to 840 mm
(Depends on response time) 50 to 420 mm
(Depends on response time) 100 mm
(Only Super-high-speed Mode)
Giga Power
(GIGA RAY) }
(Margin: × 160) {{
High-speed
response2
(fastest response
time)
{
(80 µs) {
(80 µs) }
(46 µs)
Function
Power tuning {{{
Automatic power
control (APC) {}
(Ultra-long-term APC) {
Timer {{{
ATC {{{
Key lock {{{
Easy key lock
(switchable) --- {{
APC margin
display --- {---
Slow-motion display
--- --- {
E3X-DA-S
3
Ratings and Specifications
Amplifier Units
1. The E3X-DA0-S Amplifier Unit allows you to use an E3X-ECT EtherCAT Communications Unit or E3X-CRT CompoNet Communications Unit.
2. Only for Pre-wired models.
3. The following details apply to inputs.
Type Standard models Ultra-long-term APC
models High-speed response
models
Standard models Model for
Communications Unit
Item Model E3X-DA@-S
(@: 21/51/7/9) E3X-DA0-S*1
E3X-DA
@
R
-S
(@:
21/51/7/9) E3X-DA
@F-S
(@:
21/51/7/9)
Light source
(wavelength) Red,4-element LED (625 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption Normal mode : 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control output /
APC alarm output 1Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max.
External input 2No-voltage input
(contact/transistor)3--- No-voltage input
(contact/transistor)3---
Protection circuits Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Re-
sponse
time
Super-high-
speed Mode 4Operate or reset: 80 µs --- Operate or reset: 80 µs
NPN output: O per at e: 46
µ
s,
Reset: 48
µ
s
PNP output: Operate: 51
µ
s,
Reset: 53
µ
s
High-speed
Mode Operate or reset: 250 µs
---
Standard Mode Operate or reset: 1 ms
High-resolution
Mode Operate or reset: 4 ms
Tough Mode Operate or reset: 16 ms
Sensitivity setting Teaching or manual method
Func-
tions
Power tuning Light emission power and reception gain, digital control method
Differential
detection
Switchable between Single-edge and Double-edge Detection Modes.
Single edge: Set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms.
Double edge: Set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms ---
Automatic
power control
(APC)
Always enabled.
High-speed control of emission current
Wide-range APC for the E3X-DA
@
R-S
Timer Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1-s increments)
ATC Provided
APC margin
display --- Provided ---
Slow-motion
display --- Provided
Zero reset Negative values can be displayed. (Threshold value is shifted.)
Resetting
settings Select from initial reset (factory defaults) or user reset (saved settings).
Mutual
interference
prevention Possible for up to 10 units 5---
ECO Mode 6Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF).
External input
setting 2Select from teaching operations, power tuning, zero reset, emitter OFF, or ATC start. ---
Output setting Select from output for each channel, area output, or self-
diagnosis. ---
Indicator Operation indicator for channel 1(orange)
Operation indicator for channel 2(orange)
Operation indicator for
channel 1(orange)
APC alarm output indicator
(orange)
Operation indicator for
channel 1(orange)
Power tuning indicator
(orange)
Contact input (relay or switch) Non-contact input (transistor)
NPN ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc. ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0. 1 mA max.)
PNP ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V. O N: Vcc - 1.5 V to Vcc (sinking c urr e n t: 3 m A max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
E3X-DA-S
4
4. The communications function and mutual interference prevention function are disabled if the detection mode is set to Super-high-speed mode.
5. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units
and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units.
6. For the standard models E3X-DA@-S (@: 21/51/7/9/0), the rated sensing distance is approximately 1/2 and the incident level is approximately
1/3 of the normal levels when ECO mode is enabled.
7. The maximum number of connectable Units is 30 when the E3X-ECT is used with the E3X-DA0-S.
8. The following temperature ranges apply for operation when an E3X-ECT or E3X-CRT Communications Unit is used with the E3X-DA0-S:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups
of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 40°C.
Wire-saving Connectors
Item Model E3X-DA@-S
(@: 21/51/7/9) E3X-DA0-S
E3X-DA
@
R
-S
(@:
21/51/7/9) E3X-DA
@F-S
(@:
21/51/7/9)
Digital display Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 19.)
Display orientation Switching between normal / reversed display is possible.
Key lock Key lock Key lock / Easy key lock.
Ambient illumination
(Receiver side) Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Maximum connectable
Units 16 (The ambient temperature specification depends on the number of connected units.)7
Ambient temperature
range
Operating: Groups of 1 to 2 Amplifiers: 25 to 55°C
Groups of 3 to 10 Amplifiers: 25 to 50°C
Groups of 11 to 16 Amplifiers: 25 to 45°C8
Storage: 30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
(Destruction)
10 to 55 Hz with a 1.5-mm
double amplitude for 2
hours each in X, Y, and Z
directions
10 to 150 Hz with a 0.7-mm
double amplitude for 80 min
each in X, Y, and Z directions
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours
each in X, Y, and Z directions
Shock resistance
(Destruction) 500 m/s2 for 3 times each in
X, Y, and Z directions 150 m/s2 for 3 times each in
X, Y, and Z directions 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired (standard cable
length: 2 m) or wire-saving
connector Connector for
Communications Unit Pre-wired (standard cable length: 2 m) or wire-saving
connector
Weight (packed state)
Pre-wired Models: Approx.
100 g, Wire-saving
Connector Models: Approx.
55 g Approx. 55 g Pre-wired Models: Approx. 100 g, Wire-saving
Connector Models: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction Manual
Item Model E3X-CN21/22/11 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact resistance 20 mmax. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor
resistance of the cable.)
No. of insertions Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.)
Materials Housing Polybutylene terephthalate (PBT)
Contacts Phosphor bronze / gold-plated nickel
Weight (packed state) Approx. 55 g Approx. 25 g
E3X-DA-S
5
Sensing Distance
E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9)
Threaded Models
Cylindrical Models
Flat Models
Sleeve Models
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method Sensing direction Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Right-angle M4 E32-T11N 2M 2,000 1,400 1,000 700 280
Straight E32-T11R 2M
Reflective
Right-angle M3 E32-C31N 2M 110 80 50 46 14
M6 E32-C11N 2M 780 560 350 320 100
Straight
M3
E32-D21R 2M 140 100 60 40 16
E32-C31 2M 330 240 150 100 44
E32-C31M 1M
M4 E32-D211R 2M 140 100 60 40 16
M6 E32-D11R 2M 840 600 350 240 100
E32-CC200 2M 1,400 1,000 600 400 180
Sensing
method Size Sensing
direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam 1 dia.
Top-view
E32-T223R 2M 450 300 250 150 60
1.5 dia. E32-T22B 2M 680 480 400 220 90
Reflective
3 dia. E32-T12R 2M 2,000 1,400 1,000 700 280
Side-view E32-T14LR 2M 750 550 450 260 100
1.5 dia.
Top-view
E32-D22B 2M 140 100 60 40 16
1.5 dia. + 0.5 dia. E32-D43M 1M 28 2 0 12 8 4
3 dia.
E32-D22R 2M 140 100 60 40 16
E32-D221B 2M 300 220 140 90 40
E32-D32L 2M 700 500 300 200 90
3 dia. + 0.8 dia. E32-D33 2M 70 50 30 20 8
Sensing
method Sensing direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
Top-view E32-T15XR 2M 2,000 1,400 1,00 0 700 280
Side-view E32-T15YR 2M 750 550 450 260 100
Flat-view E32-T15ZR 2M
Reflective
Top-view E32-D15XR 2M 840 600 350 240 100
Side-view E32-D15YR 2M 200 140 100 52 24
Flat-view E32-D15ZR 2M
Sensing
method Sensing direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
Side-view E32-T24R 2M 170 120 100 50 20
E32-T24E 2M 450 300 250 150 60
Top-view E32-T33 1M 150 110 90 50 20
E32-TC200BR 2M 2,000 1,400 1,000 700 280
Reflective
Side-view E32-D24R 2M 70 52 30 20 8
Top-view
E32-D43M 1M 28 20 12 8 4
E32-D331 2M 14 10 6 4 2
E32-D33 2M 70 50 30 20 8
E32-DC200F4R 2M 140 100 60 40 16
E32-DC200BR 2M 840 600 350 240 100
E3X-DA-S
6
E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9)
Small-spot, Reflective
High-power Beam
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Type Spot diameter Center
distance
(mm) Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Variable spot
0.1 to 0.6 dia. 6 to 5 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia. 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
Parallel light 4 dia. 0 to 20 E32-C31 2M + E39-F3C Spot diameter of 4 mm max. at 0 to 20 mm.
E32-C31N 2M + E39-F3C
Integrated
lens 0.1 dia. 5 E32-C42S 1M Spot diameter of 0.1 mm at 5 mm.
6 dia. 50 E32-L15 2M Spot diameter of 6 mm at 50 mm.
Small-spot
0.1 dia.
7
E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm.
0.5 dia. E32-C31 2M + E39-F3A-5 Spot diameter of 0.5 mm at 7 mm.
E32-C31N 2M + E39-F3A-5
0.2 dia.
17
E32-C41 1M + E39-F3B Spot diameter of 0.2 mm at 17 mm.
0.5 dia. E32-C31 2M + E39-F3B Spot diameter of 0.5 mm at 17 mm.
E32-C31N 2M + E39-F3B
3 dia. 50 E32- C C 2 00 2M + E39-F18 Spot diameter of 3 mm at 50 mm.
E32-C11N 2M + E39-F18
Type Sensing
direction Aperture
angle Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-beam
Integrated lens
Top-view 10 ° E32-T17L 10M 20,000 *1 20,000 *1 20,000 *1 20,000 *18,000
Side-view 30 ° E32-T14 2M 4,000 *24,000 *2 4,000 *2 4,000 *21,800
Through-
beam
models with
lenses
Right-angle 12 ° E32-T11N 2M + E39-F1 4,000 *24,000 *2 4,000 *2 4,000 *22,000
6 ° E32-T11N 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *23,600
Top-view 12 ° E32-T11R 2M + E39-F1 4,000 *24,000 *2 4,000 *2 4,000*22,000
6 ° E32-T11R 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *23,600
Side-view 60 ° E32-T11R 2M + E39-F2 1,450 1,040 800 500 200
Top-view 12 ° E32-T11 2M + E39-F1 4,000 *24,000 *2 4,000 *2 4,000 *21,860
6 ° E32-T11 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *2 4,000 *2
Side-view 60 ° E32-T11 2M + E39-F2 2,300 1,640 1,320 860 320
Top-view 12 ° E32-T51R 2M + E39-F1 4,000 *24,000 *2 4,000 *2 3,900 1,500
6 ° E32-T51R 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *2 4,000 *2
Side-view 60 ° E32-T51R 2M + E39-F2 1,400 1,000 720 500 200
Top-view 12 ° E32-T81R-S 2M + E39-F1 4,000 *24,000 *2 4,000 *2 2,700 1,000
6 ° E32-T81R-S 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *21,800
Side-view 60 ° E32-T81R-S 2M + E39-F2 1,000 720 550 360 140
Top-view 12 ° E32-T61-S 2M + E39-F1 4,000 *24,000 *2 4,000 *2 4,000 *21,800
6 ° E32-T61-S 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *23,100
Side-view 60 ° E32-T61-S 2M + E39-F2 1,680 1,200 900 600 240
Top-view 12 ° E32-T51 2M + E39-F1-33 4,000 *24,000 *2 4,000 *2 2,300 1,400
6 ° E32-T51 2M + E39-F16 4,000 *24,000 *2 4,000 *2 4,000 *2 4,000 *2
Reflective
Integrated
lens Top-view 4 ° E32-D16 2M 40 to 2,800 40 to 2,000 40 to 1,400 40 to 900 40 to 480
E3X-DA-S
7
E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9)
Narrow View
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Detection without Background Interference
Transparent Object Detection (Retro-re flective)
Transparent Object Detection (Limited-reflective)
Chemical-resistant, Oil-resistan t
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method Sensing direction Aperture
angle Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Side-view
1.5 ° E32-A03 2M 3,220 2,300 1,780 1,200 500
E32-A03-1 2M
3.4 ° E32-A04 2M 1,280 920 680 450 200
4 °
E32-T24SR 2M 4,000 *2,960 2,200 1,460 580
E32-T24S 2M 4,000 *3,500 2,600 1,740 700
E32-T22S 2M 4,000 *4,000 *3,800 2,500 1,000
Sensing
method Sensing direction Model S ensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Limited-
reflective Flat-view E32-L16-N 2M 0 to 15 0 to 12
E32-L24S 2M 0 to 4
Side-view E32-L25L 2M 5.4 to 9 (center 7.2)
Sensing
method Feature Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard mode High-speed
mode Super-high-
speed mode
Retro-
reflective
Film detection M3 E32-C31 2M + E39-F3R
+ E39-RP37 250 200
Square E32-R16 2M 150 to 1,500
Threaded Models M6 E32-R21 2M 10 to 250
Sensing
method Feature Sensing
direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard mode High-speed
mode Super-high-
speed mode
Limited-
reflective
Small size
Flat-view
E32- L24S 2M 0 to 4
Standard E32-L16-N 2M 0 to 15 0 to 12
Glass substrate
alignment, 70 °C E32-A08 2M 10 to 20
Standard/
long-distance E32-A12 2M 12 to 30
Side view form Side-view E32-L25L 2M 5.4 to 9 (center 7.2)
Glass substrate
mapping, 70 °C Top-view E32-A09 2M 15 to 38
Sensing
method Type Sensing
direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard mode High-speed
mode Super-high-
speed mode
Through-
beam
Oil-resistant
Right-angle
E32-T11NF 2M 4,000 *14,000 *1 4,000 *1 4,000 *1 2,200
Chemical/oil-
resistant Top-view E32-T12F 2M 4,000 *14,000 *1 4,000 *1 4,000 *1 1,600
E32-T11F 2M 4,000 *14,000 *1 4,000 *1 2,600 1,000
Side-view E32-T14F 2M 1,400 1,000 800 5 00 200
Chemical/oil-resistant
at 150 °C
Top-view E32-T51F 2M 4,000 *1 3,600 2,800 1,800 700
Reflective
Semiconductors:
Cleaning, developing,
and etching; 60°C
Top-view
E32-L11FP 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
19 to 31 mm from center of moun ting hole A (Recommended detecti on distance: 22 mm)
Semiconductors:
Resist stripping ; 85°
C
E32-L11FS 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
32 to 44 mm from center of moun ting hole A (Recommended detecti on distance: 35 mm)
Chemical/oil-resistant
E32-D12F 2M *2 320 190 130 60
Chemical-resistant cable
E32-D11U 2M 840 600 350 240 100
E3X-DA-S
8
E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9)
Bending-resistant
Heat-resistant
Area Beam
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
1.5 dia. E32-T22B 2M 680 480 400 220 90
M3 E32-T21 2M
M4 E32-T11 2M 2,500 1,800 1,350 900 360
Square E32-T25XB 2M 500 360 300 170 70
Reflective
1.5 dia. E32-D22B 2M 140 100 60 40 16
M3 E32-D21 2M
3 dia. E32-D221B 2M 300 220 140 90 40
M4 E32-D21B 2M
M6 E32-D11 2M 840 600 350 240 100
Square E32-D25XB 2M 240 170 100 60 30
Sensing
method Heat-resistant temperatur e Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
100 °C E32-T51R 2M 1,600 1,100 800 560 225
150 °C E32-T51 2M 2,800 2,000 1,500 1,000 400
200 °C E32-T81R-S 2M 1,000 720 550 360 140
350 °C E32-T61-S 2M 1,680 1,200 900 600 240
Reflective
100 °C E32-D51R 2M 670 480 280 190 80
150 °C E32-D51 2M 1,120 800 450 320 144
200 °C E32-D81R-S 2M 420 300 180 120 54
300 °C E32-A08H2 2M 10 to 20
E32-A09H2 2M 20 to 30 (center 25)
350 °C E32-D611-S 2M 420 300 180 120 54
E32-D61-S 2M
400 °C E32-D73-S 2M 280 200 120 80 36
Sensing
method Type Sensing
width Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Area 11 mm E32-T1 6PR 2M 3,100 2,200 1,700 1,120 440
E32-T16JR 2M 2,750 2,000 1,500 960 380
30 mm E32-T16WR 2M 4,000 *3,400 2,600 1,700 680
Reflective Array 11 mm E32-D36P1 2M 700 500 300 200 90
Sensing method Tube
diameter Feature Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Tube-mounting
3.2/6.4/9.5 dia
Stable residual
quantity dete ctio n
E32-A01 5M Applicable tube: Transparent tube with a diamet er of 3.2, 6.4, or 9.5 mm,
Recommended wall thickness: 1 mm
8 to 10 dia Mounting at
multi levels E32-L25T 2M Applicable tube: Transp arent tube with a diameter of 8 to 10 mm,
Recommended wall thickness: 1 mm
No restrict ions
Large tubes E32-D36T 2M Applicable tube: Transparent tube (no restrict ions on diameter)
Liquid contact
(heat-resistant
up to 200 °C) E32-D82F1 4M Liquid-contact Type
E3X-DA-S
9
E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9)
Vacuum-resistant
FPD, Semiconductors, and Solar Cells
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method Heat-resis tant temperature Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam 120 °C E32-T51V 1M 720 520 400 260 100
E32-T51V 1M + E39-F1V
3,780 2,700 2,000 1,360 520
200 °C E32-T84SV 1M 1,760 1,250 950 640 260
Sensing
method Application Operating
temperature Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Limited-
reflective
Glass presenc e detection
70 °C E32-L16-N 2M 0 to 15 0 to 12
Glass substrate alignment
E32-A08 2M 10 to 20
300 °C E32-A08H2 2M
70 °C E32-A12 2M 12 to 30
Glass substrate mappi n g
E32-A09 2M 15 to 38
300 °C E32-A09H2 2M 20 to 30
Wet processes:
Cleaning, Resist
developin g and etching
60 °C E32-L11FP 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended dete ction distance: 22 mm)
Wet process:
Resist stripping
85 °C E32-L11FS 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended dete ction distance: 35 mm)
Through-
beam Wafer mapping 70 °C
E32-A03 2M 3,220 2,300 1,780 1,200 500
E32-A03-1 2M
E32-A04 2M 1,280 920 680 450 200
E32-T24SR 2M 4,000 *2,960 2,200 1,460 580
E32-T24S 2M 4,000 *3,500 2,600 1,740 700
E3X-DA-S
10
E3X-DA@R-S (@:21/51/7/9)
Threaded Models
Cylindrical Models
Flat Models
Sleeve Models
Sensing
method Sensing direction Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Right-angle M4 E32-T11N 2M 1,000 700 500 350 140
Straight E32-T11R 2M 1,000 700 530 350 140
Reflective
Right-angle M3 E32-C31N 2M 55 40 25 23 7
M6 E32-C11N 2M 390 280 175 160 50
Straight
M3
E32-D21R 2M 70 50 30 20 8
E32-C31 2M 165 120 75 50 22
E32-C31M 1M
M4 E32-D211R 2M 70 50 30 20 8
M6 E32-D11R 2M 420 300 170 120 50
E32-CC200 2M 700 500 300 200 90
Sensing
method Size Sensing
direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
1 dia.
Top-view
E32-T223R 2M 220 160 130 75 30
1.5 dia. E32-T22B 2M 340 240 200 110 45
3 dia. E32-T12R 2M 1,000 700 530 350 140
Side-view E32-T14LR 2M 370 270 210 130 50
Reflective
1.5 dia.
Top-view
E32-D22B 2M 70 50 30 20 8
1.5 dia. +
0.5 dia. E32-D43M 1M 1511642
3 dia.
E32-D22R 2M 70 50 30 20 8
E32-D221B 2M 150 110 70 45 20
E32-D32L 2M 350 250 150 100 45
3 dia. +
0.8 dia. E32-D33 2M 35 25 16 10 4
Sensing
method Sensing direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
Top-view E32-T15XR 2M 1,000 700 530 350 140
Side-view E32-T15YR 2M 370 270 210 130 50
Flat-view E32-T15ZR 2M
Reflective
Top-view E32-D15XR 2M 420 300 170 120 50
Side-view E32-D15YR 2M 100 70 40 26 12
Flat-view E32-D15ZR 2M
Sensing
method Sensing direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
Side-view E32-T24R 2M 85 60 50 25 10
E32-T24E 2M 225 150 125 75 30
Top-view E32-T33 1M 75 55 45 25 10
E32-TC200BR 2M 1,000 700 530 350 140
Reflective
Side-view E32-D24R 2M 35 26 15 10 4
Top-view
E32-D43M 1M 1511642
E32-D331 2M 75320.8
E32-D33 2M 35 25 16 10 4
E32-DC200F4R 2M 70 50 30 20 8
E32-DC200BR 2M 420 300 170 120 50
E3X-DA-S
11
E3X-DA@R-S (@:21/51/7/9)
Small-spot, Reflective
High-power Beam
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Type Spot diameter Center
distance
(mm) Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Variable spot
0.1 to 0.6 dia. 6 to 15 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia. 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
Parallel light 4 dia. 0 to 20 E32-C31 2M + E39-F3C Spot diameter of 4 mm max. at 0 to 20 mm.
E32-C31N 2M + E39-F3C
Integrated
lens 0.1 dia. 5 E32-C42S 1M Spot diameter of 0.1 mm at 5 mm.
6 dia. 50 E32-L15 2M Spot diameter of 6 mm at 50 mm.
Small-spot
0.1 dia.
7
E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm.
0.5 dia. E32-C31 2M + E39-F3A-5 Spot diameter of 0.5 mm at 7 mm.
E32-C31N 2M + E39-F3A-5
0.2 dia.
17
E32-C41 1M + E39-F3B Spot diameter of 0.2 mm at 17 mm.
0.5 dia. E32-C31 2M + E39-F3B Spot diameter of 0.5 mm at 17 mm.
E32-C31N 2M + E39-F3B
3 dia. 50 E32-CC200 2M + E39-F18 Spot diameter of 3 mm at 50 mm.
E32-C11N 2M + E39-F18
Type Sensing
direction Aperture
angle Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-beam
Integrated lens
Top-view 10 ° E32-T17L 10M 20,000 *1 20,000 *1 20,000 *1 10,000 4,000
Side-view 30 ° E32-T14 2M 4,000 *2 4,000 *2 3,400 2,250 900
Through-
beam
models with
lenses
Right-angle 12 ° E 32-T11N 2M + E39-F1 4,000 *2 4,000 *2 3,700 2,400 970
6 ° E32-T11N 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 4,000 *2 1,800
Top-view 12 ° E32-T11R 2M + E39-F1 4,000 *2 4,000 *2 3,700 2,400 970
6 ° E32-T11R 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 4,000 *2 1,800
Side-view 60 ° E32-T11R 2M + E39-F2 725 520 400 250 100
Top-view 12 ° E32-T11 2M + E39-F1 4,000 *2 4,000 *2 3,600 2,300 930
6 ° E32-T11 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 4,000 *2 2,300
Side-view 60 ° E32-T11 2M + E39-F2 1,150 820 660 430 160
Top-view 12 ° E32-T51R 2M + E39-F1 4,000 *2 3,900 2,900 1,900 760
6 ° E32-T51R 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 3,600 1,400
Side-view 60 ° E32-T51R 2M + E39-F2 700 500 360 250 100
Top-view 12 ° E32-T81R-S 2M + E39-F1 4,000 *2 2,650 2,100 1,300 520
6 ° E32-T81R-S 2M + E39-F16 4,000 *2 4,000 *2 3,600 2,300 900
Side-view 60 ° E32-T81R-S 2M + E39-F2 500 360 280 180 70
Top-view 12 ° E32-T61-S 2M + E39-F1 4,000 *2 4,000 *2 3,400 2,200 900
6 ° E32-T61-S 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 3,900 1,500
Side-view 60 ° E32-T61-S 2M + E39-F2 840 600 450 300 120
Top-view 12 ° E32-T51 2M + E39-F1-33 4,000 *2 3,400 2,660 1,150 700
6 ° E32-T51 2M + E39-F16 4,000 *2 4,000 *2 4,000 *2 4,000 *2 2,600
Reflective
Integrated
lens Top-view 4 ° E32-D16 2M 40 to 1,400 40 to 1,000 40 to 700 40 to 450 40 to 240
E3X-DA-S
12
E3X-DA@R-S (@:21/51/7/9)
Narrow View
Detection without Background Interference
Transparent Object Detection (Retro-ref lective)
Transparent Object Detection (Limited-reflective )
Chemical-resistant, Oil-resistant
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Sensing
method Sensing direction Aperture
angle Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Side-view
1.5 ° E32-A03 2M 1,610 1,150 890 600 250
E32-A03-1 2M
3.4 ° E32-A04 2M 640 460 340 225 100
4 °
E32-T24SR 2M 2,100 1,500 1,100 750 300
E32-T24S 2M 2,400 1, 750 1,300 870 350
E32-T22S 2M 3,500 2,500 1,900 1,250 500
Sensing
method Sensing direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Limited-
reflective Flat-view E32-L16-N 2M 0 to 15 0 to 12
E32-L24S 2M 0 to 4
Side-view E32-L25L 2M 5.4 to 9 (center 7.2)
Sensing
method Feature Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Retro-
reflective
Film detection M3 E32-C31 2M + E39-F3R
+ E39-RP37 250 200 150 100 50
Square E32-R16 2M 150 to 1,500
Threaded Models M6 E32-R21 2M 10 to 250
Sensing
method Feature Sensing
direction Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Limited-
reflective
Small size
Flat-view
E32- L24S 2M 0 to 4
Standard E32-L16-N 2M 0 to 15 0 to 12
Glass substrate
alignment, 70 °C E32-A 0 8 2 M 10 to 20
Standard/
long-distance E32-A12 2M 12 to 30
Side view form Side-view E32-L25L 2M 5.4 to 9 (center 7.2)
Glass substrate
mapping, 70 °C Top -v i ew E32-A0 9 2M 15 to 38
Sensing
method Type Sensing
direction Model Sensing distance (m m)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mod e
Through-
beam
Oil-resistant
Right-angle
E32-T11NF 2M 4,000 *1 4,000 *1 4,000 *1 3,100 1,200
Chemical/oil-
resistant Top-view E32-T12F 2M 4,000 *1 4,000 *1 3,000 2,000 800
E32-T11F 2M 3,500 2,500 2,000 1,300 520
Side-view E32-T14F 2M 700 500 400 250 100
Chemical/oil-resistant
at 150 °C
Top-view E32-T51F 2M 2,500 1,800 1,400 900 350
Reflective
Semiconductors:
Cleaning, developing,
and etching; 60°C
Top-view
E32-L11FP 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended detect ion distance: 22 mm)
Semiconductors:
Resist stripping; 85°
C
E32-L11FS 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended detect ion distance: 35 mm)
Chemical/oil-resistant
E32-D12F 2M *2 160 95 65 30
Chemical-r esistant cabl e
E32-D11U 2M 420 300 170 120 50
E3X-DA-S
13
E3X-DA@R-S (@:21/51/7/9)
Bending-resistant
Heat-resistant
Area Beam
Liquid-level Detection
Sensing
method Size Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
1.5 dia. E32-T22B 2M 340 240 200 110 45
M3 E32-T21 2M
M4 E32-T11 2M 1,250 900 680 450 180
Square E32-T25XB 2M 250 180 150 85 35
Reflective
1.5 dia. E32-D22B 2M 70 50 30 20 8
M3 E32 - D 2 1 2M
3 dia. E32-D221B 2M 150 110 70 45 20
M4 E32-D21B 2M
M6 E32-D11 2M 420 300 170 120 50
Square E32-D25XB 2M 120 85 50 30 15
Sensing
method Heat-resis tant temperature Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam
100 °C E32-T51R 2M 800 560 425 280 110
150 °C E32-T51 2M 1,400 1,000 760 500 200
200 °C E32-T81R-S 2M 500 360 280 180 70
350 °C E32-T61-S 2M 840 600 450 300 120
Reflective
100 °C E32-D51R 2M 330 240 135 95 40
150 °C E32-D51 2M 560 400 230 160 72
200 °C E32-D81R-S 2M 210 150 90 60 27
300 °C E32-A08H2 2M 10 to 20
E32-A09H2 2M 20 to 30 (center 25)
350 °C E32-D611-S 2M 210 150 90 60 27
E32-D61-S 2M
400 °C E32-D73-S 2M 140 100 60 40 18
Sensing
method Type Sensing
width Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam Area 11 mm E32-T16PR 2M 1,550 1,100 840 560 220
E32-T16JR 2M 1,370 980 750 480 190
30 mm E32-T16WR 2M 2,000 1,700 1,300 850 340
Reflective Array 11 mm E32-D36P1 2M 350 250 150 100 45
Sensing method Tube
diameter Feature Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Tube-mounting
3.2/6.4/9.5 dia
Stable res i dual
quantity detection
E32-A01 5M Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm,
Recommended wall thickness: 1 mm
8 to 10 dia Mounting at
multi levels E32-L25T 2M Applicable tube: Transparent tube with a diame ter of 8 to 10 mm,
Recommended wall thickness: 1 mm
No restrictions
Large tubes E32-D36T 2M Applicable tube: Transparent tube (no restrictions on diameter)
Liquid cont a c t
(heat-resistant
up to 200 °C) E32-D82F1 4M Liquid-contact Type
E3X-DA-S
14
E3X-DA@R-S (@:21/51/7/9)
Vacuum-resistant
FPD, Semiconductors, and Solar Cells
Sensing
method Heat-resistant temperatur e Model Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mode
Through-
beam 120 °C E32-T51V 1M 360 260 200 130 50
E32-T51V 1M + E39-F1V
1,890 1,350 1,000 680 260
200 °C E32-T84SV 1M 880 630 480 320 130
Sensing
method Application Operating
temperature Model Sensing dis tance (mm)
Tough mode
High-resolution
mode
Standard
mode High-speed
mode Super-high-
speed mod e
Limited-
reflective
Glass presence detection
70 °C E32-L16-N 2M 0 to 15 0 to 12
Glass substrate alignment
E32-A08 2M 10 to 20
300 °C E32-A08H2 2M
70 °C E32-A12 2M 12 to 30
Glass substrate mapping
E32-A09 2M 15 to 38
300 °C E32-A09H2 2M 20 to 30 (center 25)
Wet processes:
Cleaning, Resist
developing and etc hing
60 °C E32-L11FP 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended detect ion distance: 22 mm)
Wet process:
Resist stripping
85 °C E32-L11FS 2M 8 to 20 mm from tip of lens (Recommended detection distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended detect ion distance: 35 mm)
Through-
beam Wafer mapping 70 °C
E32-A03 2M 1,610 1,150 890 600 250
E32-A03-1 2M
E32-A04 2M 640 460 340 225 100
E32-T24SR 2M 2,100 1,500 1,100 750 300
E32-T24S 2M 2,400 1,750 1,300 870 350
E3X-DA-S
15
I/O Circuit Diagrams
NPN Output
PNP Output
Note: 1. Operation with area settings is as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2. Timing Charts for Timer Settings (T: Set Time)
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA21-S
E3X-DA21R-S
E3X-DA21F-S
Light-ON LIGHT ON
(L-ON)
1. For the E3X-DA21R-S, this is the APC alarm output.
This output does not exist on the E3X-DA21F-S.
2. This input does not exist the E3X-DA21F-S.
Dark-ON DARK ON
(D-ON)
E3X-DA7-S
E3X-DA7R-S
E3X-DA7F-S
Light-ON LIGHT ON
(L-ON)
For the E3X-DA7R-S, this is the APC alarm output.
This output does not exist on the E3X-DA7F-S.
Dark-ON DARK ON
(D-ON)
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA51-S
E3X-DA51R-S
E3X-DA51F-S
Light-ON LIGHT ON
(L-ON)
1. For the E3X-DA51R-S, this is the APC alarm output.
This output does not exist on t he E3X-DA51F-S.
2. This input does not exist the E3X-DA51F-S.
Dark-ON DARK ON
(D-ON)
E3X-DA9-S
E3X-DA9R-S
E3X-DA9F-S
Light-ON LIGHT ON
(L-ON)
For the E3X-DA9R-S, this is the APC alarm output.
This output does not exist on the E3X-DA9F-S.
Dark-ON DARK ON
(D-ON)
ON delay OFF delay One-shot ON de lay and OFF delay
T1: ON-delay set time
T2: OFF-delay set time
T1 and T2 can be set separately.
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and
black
(oran
g
e) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Load
Load
Operation indicator
(orange) ch2 Brown
Black
Control output
ch1
Control output
ch2 1
External
input 2
Orange
Blue
Pink
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
E3X-DA21-S
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
E3X-DA7-S
Load
Load
Operation indicator
(orange) ch2 Brown
Black
Control output
ch1
Control output
ch2
Orange
Blue
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black (oran
g
e) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
E3X-DA51-S
Load
Load
Operation indicator (orange) ch2 Brown
Black
Control output
ch1
Control output
ch2
1
External
input 2
Orange
Pink
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Blue
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
E3X-DA9-S
Load
Load
Operation indicator (orange) ch2 Brown
Black
Blue
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Control output
ch1
Control output
ch2
Orange
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black (orange) leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T2T1
T1T2
E3X-DA-S
16
Nomenclature
Operating Procedure
Amplifier Units
E3X-DA@-S (@: 21/51/7/9/0)
Locks the fiber.
Incident level, function, etc. Threshold, function settings,
etc.
Use to select the channel to display and set.
Use to select SET or RUN Mode.
Function setting
operations UP
DOWN
MODE
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(ch1) (orange)
Lock lever
Main Display (Red) Sub-Display (Green)
Channel Selector
Mode Selector
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(ch2) (orange)
Operation Keys
Note: Nomenclature and operating procedures for the E3X-
DA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on
pages 19 and 20.
3 s
MODE
UP DOWN
RUN
RUN
DOWN MODE
Press
both
for 3 s.
Setting the Operation Mode1
The operation mode is set in SET Mode.
Adjusting the Power (RUN Mode)2
The current incident light level can be adjusted near the
power tuning target value (default: 2,000).
Set the Channel Selector Switch to the desired channel
before making any adjustments or settings.
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Release the key after
the progress bar is
displayed.
This completes the
adjustment.
Incident level Threshold (default)
PTUN Progress bar
Display changes after
specific time.
Power tuning
target value
Incident level Threshold
Setting Thresholds Manually (RUN Mode)3
Display Error Action
A threshold can be set manually. A threshold can also
be adjusted manually after teaching to fine-tune it.
This restores the default
setting.
"OFF" will flash twice.
Even if the display method is changed, the threshold will appear
on the sub-display when the key is pressed.
Setting Errors
An error has occurred if one of the following displays appears after
the progress bar is displayed.
Over Error
The incident light
level is too low
for the power
tuning target
value.
Bottom Error
The incident light
level is too high
for the power
tuning target
value.
Set the Mode Selector
Switch to RUN.
(Factory-set to RUN)
PTUN OFF
PTUN OVER
PTUN BOTM
Light level
Increases threshold. Decreases threshold.
Threshold (default)
Incident level
Flashes twice
Threshold
Flashes twice
Press the DOWN Key
right after pressing
the MODE Key.
To restore the default
power setting:
Confirm that the MODE Key setting is PTUN (power tuning). The
default setting is PTUN.
If power tuning is executed while SHS is selected for the detection
function, the minimum power will be set.
The power will not
be tuned. The power
can be increased up
to approximately 5
times the incident
light value.
The power will be
turned to the
minimum level. The
power can be
decreased down to
approximately
1/20th the incident
light value.
Refer to 5. Setting Functions on page 18.
Refer to 5. Setting Functions on page 18.
E3X-DA-S
17
UP DOWN
UP DOWN
SET
UP DOWN
RUN
Incident level Threshold
TECH ----
Incident level Threshold
THRU Threshold
Press
either
for 1 s. Press
either
for 1 s.
Press
either
for 1 s.
Press
either
for 1 s.
To RUN
UP DOWN
Incident level Threshold
FULL Threshold
Incident level Threshold
Press
either
for 3 s. Press
either
for 3 s.
Incident level Threshold
UP DOWN
UP DOWN
Workpiece
TECH ----
Incident level Threshold
2PNT Threshold
Teaching the Threshold (SET Mode)4
You can set the threshold to above the incident light level without
a workpiece by the percentage set for the teaching level.
"----" will be displayed.
With no workpiece:
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
The threshold that
was set will flash twice.
Incident level Threshold
TECH ----
Incident level Threshold
RFCT Threshold
4-3.
Teaching a Reflective Fiber Unit without a Workpiece
Set the SET/RUN Mode
Selector Switch to SET.
SET
4-1. Setting the Threshold at Maximum Sensitivity
The threshold can be set to the maximum sensitivity.
This is useful when the longest detection distance is
required.
Set the SET/RUN Mode
Selector Switch to SET.
The threshold that
was set will flash twice.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
SET
You can set the threshold to below the incident light level
without a workpiece by the percentage set for the teaching
level.
"----" will be displayed.
With no workpiece:
With no workpiece:
The threshold that
was set will flash twice.
4-2.
Teaching a Through-beam Fiber Unit without a Workpiece
Set the SET/RUN Mode
Selector Switch to SET.
SET
Two points in the following figures are detected, and
the intermediate point of the light levels for the
two points is set as the threshold.
"----" will be displayed.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
The threshold that
was set will flash twice.
4-4. Two-point Teaching
4-5. Positioning Teaching
Set the SET/RUN Mode
Selector Switch to SET.
With a workpiece:
For positioning
teaching, place the
workpiece where
you want to
position it.
With no workpiece:
For positioning
teaching, place the
workpiece where
you want to
position it.
There are five methods that can be used for teaching, as described
below. Use the method most suitable for the application.
Two-point teaching, positioning teaching, and automatic teaching
can be performed in RUN Mode.
For operating procedures, refer to the Instruction Manual provided
with the product.
An error has occurred if OVER or LO is displayed on the
sub-display. If that occurs, repeat the operation from the beginning.
This completes the
setting procedure.
Refer to 5. Setting Functions on page 18.
Refer to 5. Setting Functions on page 18.
E3X-DA-S
18
The detection settings and MODE Key settings are the same for channel 1 and channel 2.
Other functions can be set separately for each channel.
Setting Functions (SET Mode)5
Moving between Functions
11. External input memory
(Refer to the Instruction Manual
provided with the sensor.)
SET
Set the SET/RUN Mode
Selector Switch to SET.
7. Display orientation
(To reverse the orientation of
the display.)
6. Display switch
(To change the display method)
4. ATC setting
(To change the ATC setting)
8. ECO Mode
(To set the ECO Mode)
9. Output setting
(To change outputs for
channel 2)
10. External input
(To change functions controlled
using the external input)
RUN
Set the SET/RUN Mode
Selector Switch to RUN.
When the
settings have
been completed
2. Timer
(To use the timer setting)
0. Operation mode
(To set the operation mode)
5. MODE Key
(To change the function of the
MODE Key during operation)
3. Teaching level
(To change the teaching level)
1. Detection
(To change response speed and
detection precision)
Teaching
MODE
The function transition boxes show the default settings.
More functions may be displayed depending on the detailed settings.
Refer to 4. Teaching the
Threshold on page 17.
Setting (display)Function Description
Used to change the response speed or detection precision.
1. Detection
Super-high-speed: , High-speed: , Standard: ,
High-resolution: , Tough: , Differential operation:
Use the UP and DOWN Keys to change the settings.
UP DOWN
Light ON: , Dark ON:
0. Operation mode
Used to set the differential response time.
Single edge: , Double edge:
Differential edge
(differential operation
selected)
Used to set the edge to be detected.
Differential time
Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms: ,
Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms:
4. ATC setting
Setting at Power-ON
(ATC ON)
Used to enable or disable the ATC function.
Used to set the processing to be performed when the
power is turned ON.
ATC enabled: , ATC disabled:
No setting: , ATC start processing: ,
Power tuning and ATC start processing:
Functions
Timer disabled: , OFF-delay timer: ,
ON-delay timer: , One-shot timer:
ON-delay + OFF-delay timer:
2. Timer
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments,
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments
Time
(timer enabled) Used to change timer settings when timers are enabled.
The timer can be set from 1 to 5,000 ms.
Used to enable or disable timers.
Executes power tuning: ,
Executes a zero reset: , Two-point teaching: ,
Automatic teaching: , ATC start:
Setting range: 100 to 3,900 (increments of 100)
Maximum power :
5. MODE Key
Power tuning target value
(performing power tuning)
Used to change the function of the MODE Key during RUN
operation.
Used to set target values during power tuning.
3. Teaching level Setting range: to Used to change the threshold setting when teaching a
Through-beam Fiber Unit without a workpiece or teaching
a Reflective Fiber Unit without a workpiece.
Refer to 1. Setting the Operation Mode on page 16.
Refer to 2. Adjusting the Power on page 16.
E3X-DA-S
19
Setting (display)Function Description
6. Display switch L-PE D-BT
Used to display the incident light level and the
threshold.
Used to display the incident light level as a percentage of
the threshold and the threshold.
Use to display the incident light peak level and no incident
light bottom level. (Refreshed when output turns ON or OFF.)
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red, OFF: Green)
Used to display the current incident light level and the peak
incident light level. Display changes at a fixed interval.
Used to display the incident light level and the channel
(unit number).
Incident level Threshold
% incident level
Threshold
Detection status
Fixed interval
Current incident
level
PEAK
Current incident
level
Peak incident
level
Fixed interval
PEAK BOTM
Incident level Channel (unit number)
Normal display: , Up/down reversed display:7. Display orientation Used to reverse the orientation of the display.
Used to enable or disable the ECO mode.
Used to display the peak and bottom levels of incident
light within a set time. (Updated every 2 s.)
Write results to EEPROM: ,
Do not write results to EEPROM:
10. External input
Used to set writing the results.
(Refer to Instruction Manual provided with the product.)
11. External input
memory
Used to change the functions to be controlled using the
external input.
(Refer to the Instruction Manual provided with the sensor.)
Through-beam, no-workpiece teaching: ,
Reflective, no-workpiece teaching: ,
Two-point teaching: , Automatic teaching: ,
Power tuning: , Zero reset: ,
Light OFF: , ATC start:
Lit digital display: , Dimmed digital display: ,
OFF:
8. ECO Mode
Each channel: ,
Output when the incident light level is between two thresholds: ,
Self-diagnosis output:
9. Output setting
Used to change the output details for channel 2.
This setting will be disabled if the detection function is set
to DIFF (i.e., differential operation) and the output will be
used for an alarm output.
E3X-DA-S
20
MODE
MODE
MODE
DOWN MODE
UP
UP
RUN
RUN
RUN
RUN
Convenient Functions6
6-1. Setting the Digital Display to Zero (Zero Reset)
The incident light level on the main display can be set to 0.
The incident light level and the threshold will both be
shifted. This is useful when you want to set the reference
display to zero.
To return to original value for incident light level:
Set the SET/RUN Mode
Selector Switch to RUN.
Factory setting
Set the SET/RUN Mode
Selector Switch to RUN.
Factory setting
Change the function to 0RST (zero reset) with the MODE Key.
The default setting is PTUN.
All key operations can be disabled.
“LOC OFF” will flash twice
and key operations will be
enabled.
To release the lock:
“LOC ON” will flash twice
and key operations will be
disabled.
6-2. Locking the Keys (Key Lock)
LOC ON
LOC OFF
Set the SET/RUN Mode
Selector Switch to RUN.
Factory setting
Set the SET/RUN Mode
Selector Switch to RUN.
Factory setting
Press
both
for 3 s.
Press
both
for 3 s.
Press
both
for 3 s.
Press
both
for 5 s.
3 s
MODE
MODE
UP DOWN
SET
All settings can be returned to the factory defaults or to
user-saved settings.
Settings initialized.Operation canceled.
INIT YES?
6-3. Resetting Settings (Initial Reset or User Reset)
Set the SET/RUN Mode
Selector Switch to SET.
INIT NO?
UP DOWN
MODE
MODE
UP
SET
Saving User Settings
The current settings can be saved.
Operation canceled.The current settings are saved.
SAVE NO?
Set the SET/RUN Mode
Selector Switch to SET.
SAVE YES?
UP DOWN
1. Press the DOWN Key right after pressing the MODE Key.
2. Press the UP Key right after pressing the MODE Key.
1
2
2
MODE
MODE
RST USERRST INIT
UP DOWN
MODE
MODE
Operation canceled.Perform user reset.
USER NO?USER
(The steps within the dotted lines can be used if settings have
been saved by the user.)
YES?
UP DOWN
MODE
If a key is pressed while key operations are locked, “LOC ON” will
flash twice on the display to
indicate that key operations have
been disabled.
Press
both
for 5 s.
Refer to 5. Setting Functions on page 18.
E3X-DA-S
21
Nomenclature
Operating Procedure
Amplifier Units
E3X-DA@R-S (@: 21/51/7/9)
Easy key lock Selector
ON when output is ON.
OFF when output is OFF.
APC alarm output
indicator (orange) Select to lock or unlock settings.
Locks the fiber.
Incident level, function, etc. Threshold, function settings, etc.
Use to select SET or RUN Mode.
Function setting
operations
UP
DOWN
MODE
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(orange)
Lock lever
Main Display (Red) Sub-Display (Green)
Mode Selector
Operation Keys
MODE
RUN
MODE
RUN
RUN
Initial status Margin APC
APC margin
displayed in
decrements of 10%
Margin APC
APC margin of less
than 10%
Margin APC
ALAT APC
The display switches
every second.
Margin APC
END APC
The display switches
every 0.5 s.
Displaying the APC Margin 2
Displaying the APC margin can be useful for planning
maintenance. When the APC margin is 0%,
APC alarm output will turn ON, and the APC alarm output
indicator will light regardless of the operation of the APC
margin display.
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Press the MODE Key to
display the following for 10 s.
APC margin is 0%.
The display will return
to the normal display.
Incident level Threshold
Press the MODE Key
or press nothing for 10 s.
Locking the Keys (Easy Key Lock) 1
Before shipment, all key operation except for the MODE
Keys can be disabled.
Locked
Unlocking
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Set the SET/RUN Mode
Selector Switch to RUN.
Set the Easy Key Lock
Selector Switch to Locked .
Locked
Set the Easy Key Lock
Selector Switch to Locked .
Unlocked
Set the Easy Key Lock
Selector Switch to Unlocked .
(Factory-set to RUN)
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@R-S.
E3X-DA-S
22
Nomenclature
Operating Procedure
Amplifier Units
E3X-DA@F-S (@: 21/51/7/9)
ON when setting is ON.
OFF when setting is OFF.
Power tuning
indicator (orange) Easy key lock Selector
Locks the fiber
Incident level, function, etc. Threshold, function settings, etc.
Use to select SET or RUN Mode.
Function setting
operations
UP
DOWN
MODE
Select to lock or unlock settings.
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(orange)
Lock lever
Main Display (Red) Sub-Display (Green)
Mode Selector
Operation Keys
MODE
RUN
RUN
MODE
RUN
"A" is displayed when
the output is ON or until
approximately 10 s
has elapsed. (Key
operations will not be
accepted in the status.)
"STAT" will be displayed
and the slow-motion
display will start.
The incident level in
intervals of 17 µs
will be displayed
for approximately 20 s
every 160 ms
(between 0.5 ms before
ON to 1.5 ms after ON).
The output ON time will
be displayed.
END will be displayed.
The display will return to
the normal display.
A
STAT
Incident level Threshold
Incident level Threshold
Incident level Threshold
Output ON time Unit: µs
END
Incident level Threshold
Incident level Threshold
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Displaying the Change of the incident level
Error
Display
2
Changes of the incident level for high-speed workpiece
detection can be displayed. This enables checking the
margin level of light received and the workpiece ON time
in slow motion.
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Turn OFF the output or
convey the workpieces.
OVER US
The following will be displayed
if the ON time exceeds 1,500 µs.
NON DETC
The following will be displayed
if the change in the light amount is low.
Press the MODE key.
Press the MODE Key,
or wait for the slow-motion
display to end.
This may also be displayed when detecting
a workpiece with a small change in light amount
or a slow workpiece of 1,500 µs or longer.
Set the SET/RUN Mode
Selector Switch to RUN.
(Factory-set to RUN)
Locking the Keys (Easy Key Lock) 1
Before shipment, all key operation except for the MODE
Keys can be disabled.
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Unlocking
Locked
Set the Easy Key Lock
Selector Switch to Locked .
Locked
Set the Easy Key Lock
Selector Switch to Locked .
Unlocked
Set the Easy Key Lock
Selector Switch to Unlocked .
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@F-S.
E3X-DA-S
23
Safety Precautions
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the sensor with voltage in excess of the
rated voltage. Excess voltage may result in
malfunction or fire.
Never use the sensor with an AC power supply.
Otherwise, explosion may result.
The following precautions must be observed to ensure safe operation
of the sensor.
1. Do not use the sensor in an environment where explosive or
flammable gas is present.
2. Do not use the sensor in a location subject to splattering with
water, streams, oils, or chemicals.
3. Do not attempt to disassemble, repair, or modify the sensor.
4. Do not apply voltages or currents that exceed the rated range to
the sensor.
5. Do not use the sensor in an ambient atmosphere or environment
that exceeds the ratings.
6. Wire the power supply correctly, including the polarity.
7. Connect the load correctly.
8. Do not short-circuit the load at both ends.
9. Do not use the sensor if the case is damaged.
10.Dispose of the sensor as industrial waste.
11.Do not use the sensor in locations subject to direct sunlight.
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
The sensor is ready to detect within 200 ms after the power supply is
turned ON. If the sensor and load are connected to separate power
supplies, be sure to turn ON the sensor first.
Time may be required for the incident level to stabilize after the power
supply is turned ON.
Operation at Power OF F
A pulse may be output when the power supply is turned OFF. Turn
OFF the power supply to the load or the load line before turning OFF
the power supply to the sensor.
Mutual Interference Protection Function
Mutual interference prevention is enabled if Amplifier Units are
connected together. It is also enabled in the same way if E3X-DA-S-
series Units and E3C-LDA-series Units are used together.
Mounting
Connecting and Disconnecting Wire-saving Connectors
Mounting Connectors
1. Insert the Master or Slave connector into the Amplifier Unit until it
clicks into place.
2. Attach the protective seals (provided as accessories) to the sides
of master and slave connectors that are not connected.
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit away from the other unit.
2. After the Amplifier Unit has been separated, press down on the
lever on the connector and remove it. (Do not attempt to remove a
connector without first separating the Amplifier Unit from the other
Units.)
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor.
WARNING
CAUTION
Precautions for Safe Use
Precautions for Correct Use
Note: 1. The specifications for ambient temperature will vary
according to the number of Amplifier Units used together.
For details, refer to Ambient temperature range on
page 4.
2. Always turn OFF the power supply before joining or
separating Amplifier Units.
Insert
Seal
Remove
Lever
Press down
Click into place
E3X-DA-S
24
Mounting the End Plate (PFP-M)
Use an End Plate if the Amplifier Unit might move due to vibration.
Fiber Connection
The E3X Amplifier Unit has a lock lever for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
1. Connecting Fibers
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock lever.
Note: If one of the fibers from the Fiber Unit is labeled as the Emitter
fiber, such as with a Coaxial Sensor, insert that fiber into the
Emitter section. Refer to Dimensions for the Fiber Unit to see if
there is an Emitter fiber label.
Fibers with E39-F9 Attachment
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
Adjusting
Mutual Interference Protection Function
The values that appear on the digital display may fluctuate somewhat
due to light from other sensors. If this occurs, you can stabilize
detection by setting a threshold that is close to half way between the
incident levels with and without a sensing object.
Output Short-circuits Protecti on
OVER/CUR will flash on the display if the output short-circuit
protection function operates due to a load short-circuit in a control
output. If this occurs, check the load connections.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
The E3X-MC11-SV2 Mobile Console does not currently support the
new Tough Mode and ON-delay + OFF-delay timer. You also cannot
use the E3X-MC-S.
Communications Unit
Using CompoNet
Use the E3X-CRT Communications Unit.
To connect this Communications Unit, you mus t use the E3X-DA0-S
Amplifier Unit.
Using EtherCAT
Use the E3X-ECT Communications Unit.
To connect this Communications Unit, you mus t use the E3X-DA0-S
Amplifier Unit.
Using DeviceNet
Use the E3X-DRT21-S Version 3 Communications Unit.
To connect this Communications Unit, you mus t use the E3X-DA7-S
or E3X-DA9-S Amplifier Unit.
Note: Do not pull on the fiber, apply pressure on it, or otherwise
subject it to excessive force when it is attached to the
Amplifier Unit. (Use a force of 0.3 N·m max.)
End Plate
9 mm
Insertion position
Locked Unlocked
Protective cover
Lock lever
Fiber insertion mark
Fiber
Fiber Unit
9 mm
13 mm
9 mm
13 mm
Note: 1. To maintain the fiber properties, confirm that the lock is
released before removing the fibers.
2. Be sure to lock or unlock the lock lever within an ambient
temperature range between 10°C and 40°C.
Locked Unlocked
Protective cover
E3X-DA-S
25
Dimensions
Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Attachment mounted (E39-F9)
10 10
LEnd Plate
(sold separately)
PFP-M
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
Center of DIN track
28.1
4.43.4
2-M3
16
16
Two, 2.4 dia.
5.65
4.5
101.45
101.45
10
10
Two, 2.4 dia.
101.45
101.45
5.65
4.5
6.3
Operation indicator (1ch) Main display Sub-display
Indicator 1
15.6 35.25
10
10
10.3
3.4
(9) 12.5
141.1
141.1
(36.2) (21.3)
70
70
32
32
180°
3.4
12.5
Vinyl-insulated round cable
Standard length: 2 m 2
141.1
141.1
70
70
32
32
Two, 3.2 dia.
Holes
Hole for optical communications
180°
Digital Display Area
DIN track mounting
Multiple connection diagram
With Mounting Bracket Attached
Mounting Holes
(9)
(9.4)
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
16
18.7 4.3
4.3
18.7
4.3
Vinyl-insulated round cable
Standard length: 2 m 2
Hole for optical communications
2. The cable specifications are as follows:
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
4 dia. cable / 5 conductors
(Conductor cross section: 0. 2 mm2,
Insulator diameter: 1.1 mm)
E3X-DA21F-S
E3X-DA51F-S
4 dia. cable / 3 conductors
(Conductor cross section: 0. 2 mm2,
Insulator diameter: 1.1 mm)
Pre-wired Models
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
The number of expansion
L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the
Amplifier Units if they are mounted side by side.
1. The indicators are as follows:
E3X-DA21-S
E3X-DA51-S Operation indicator
(2 ch)
E3X-DA21R-S
E3X-DA51R-S APC alarm output
indicator
E3X-DA21F-S
E3X-DA51F-S Power tuning
indicator
E3X-DA-S
26
6.3
Operation indicator (1ch) Main display Sub-display
Indicator 1
15.6 35.25
Fiber Attachment mounted (E39-F9)
5.65
4.5
101.45
101.45
Two, 2.4 dia.
101.45
101.45
5.65
4.5
10 10
LEnd Plate
(sold separately)
PFP-M
10
10
10
10
Two, 2.4 dia.
28.1
4.4
3.4
16
2-M3
Fiber Attachment mounted (E39-F9)
12.95
Dia. A 2
(9.4)
141.1
141.1
70
70
32
32
Two, 3.2 dia.
Holes
180°
3.4
12.95
Dia. A 2
141.1
141.1
(36.2) (21.3)
(9)
70
70
32
32
180°
3.4
Digital Display Area
DIN track mounting
Multiple connection diagram
With Mounting Bracket Attached
Mounting Holes
(9)
4.3
8.1
Hole for optical communications
18.7
Center of DIN track
DIN track
(sold separately)
PFP-@N
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Hole for optical communications
16
18.7 4.3
8.1
4.3
10.3
16
Wire-saving Connector Models
E3X-DA7-S
E3X-DA9-S
E3X-DA7R-S
E3X-DA9R-S
E3X-DA7F-S
E3X-DA9F-S
2. The cable diameters are as follows:
E3X-CN21 (4 conductors)
E3X-CN22 (2 conductors)
E3X-CN11 (3 conductors)
4.0 dia.
E3X-CN12 (1 conductor)
2.6 dia.
The number of expansion
L (mm)
110
220
330
440
550
660
770
880
990
10 100
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier
Units if they are mounted side by side.
1. The indicators are as follows:
E3X-DA7-S
E3X-DA9-S Operation indicator
(2 ch)
E3X-DA7R-S
E3X-DA9R-S APC alarm output
indicator
E3X-DA7F-S
E3X-DA9F-S Power tuning
indicator
E3X-DA-S
27
Wire-saving Connectors
Communicatio ns Unit Connector Models (for EtherCAT and CompoNet)
E3X-DA0-S
4.5
5.65
Two, 2.4 dia.
15.1
32.8
4.3
28.1 16
34.8
70 8.1
44.3
32
3.4
10
28.1 16
3.4
4.4
11.7
11.75
12.15 3.25
29.8
Two, 3.2 dia.
18.7
Master Connector
E3X-CN21
(7)
2,000+50
0
Edge of amplifier
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave Connector
E3X-CN22
(7)
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
2,000
+50
0
Edge of amplifier
E3X-DA-S
28
Accessories (sold separately)
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
Master Connector
E3X-CN11
(7)
Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
2,000+50
0
Edge of amplifier
Slave Connector
E3X-CN12
(7)
Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
2,000+50
0
Edge of amplifier
Mounting Brackets
E39-L143
Four, R1.7
7
3.4
1
3163
10
max.
710.3
7.3
5.3
(10.3) 2.5
34.8
22
16
26.8
3
Two, 3.2 dia.
3.4 1
2-M3
16±0.1
Mounting Holes
Material: Stainless stee l (SUS304)
End Plate
PFP-M 50
11.5
10
M4×8
panhead screw
M4 spring washer
4.8
1.3 1.8 1.8
1
6.2 10
35.5
35.3
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRA CT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party cer tif ication documents identifying ratings and limitations of use that apply
to the products. This inf ormation by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applica tions for w hich par ticular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, co mbustion systems, railroad systems, aviation systems, medical equipment, amu sement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determ ining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual perf ormance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the pr oduct may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has be en carefully checked and is believed to be accurate; however, no responsibility is assum ed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
CSM_3_1_0912
Cat. No. E396-E1-03 Printed in Japan
(0510)
© OMRON Corporation 2010 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200