2726
Compact High Voltage Power Supply Units C1309 Series
FEATURES
Compact and lightweight
Allows direct mounting on a PC board.
High stability
Ensures excellent input regulation, load regulation and drift.
Fully enclosed metal-shielded package
Provides effective noise shielding
Parameter C1309-01 C1309-02 C1309-04 C1309-06 Unit
Input Voltage A+12 to +16 +14 to +16 +14 to +16 +14 to +16 V dc
Input Current AB 300 170 170 250 mA Max.
Output Voltage
-
400 to
-
800
-
200 to
-
1100
-
200 to
-
1100
-
400 to
-
1500
V dc
Specification Guaranteed Output Voltage Range
-
500 to
-
800
-
400 to
-
1100
-
400 to
-
1100
-
500 to
-
1500
V dc
Output Current 2 0.7 0.7 1 mA Max.
Line Regulation BC ±0.1 ±0.06 ±0.06 ±0.05 % Typ.
Load Regulation against 0 to 100% Load Change
D±0.1 ±0.15 ±0.15 ±0.2 % Typ.
Ripple/Noise (p-p) B300 100 100 150 mV Typ.
Drift (After Warm-up) B±0.2 ±0.1 ±0.02 ±0.1 %/h Typ.
Programming Resistance 1 10 10 10 k
Programming Voltage +4.8 to +7 0 to +1.4 0 to +1.4 0 to +1.4 V dc
Output Voltage Rise Time (10 %90 %) B30 200 200 200 ms Typ.
Temperature Coefficient BE ±0.05 ±0.03 ±0.005 ±0.02 %/ °C Typ.
Warm-up Time 15 15 15 15 min Typ.
Operating Temperature B+5 to +40 +5 to +40 +5 to +40 +5 to +40 °C
Storage Temperature
-
5 to +60
-
5 to +60
-
5 to +60 5 to +60 °C
Weight 140 120 120 120 g
NOTE AWith single supply voltage.
BMaximum output voltage and current.
C±2 V input change for C1309-01.
±1 V input change for C1309-02, -04 and -06.
DMaximum output voltage.
EOperating temperature: +5 °C to +40 °C
Dimensional Outlines (Unit: mm)
TACCA0123EA
Specifications
21
77
71
60
48
54
56
20
1234
1010 10
(SIDE VIEW)
4-No.2-56UNC
(4PCS OF SCREWS SUPPLIED)
1.0 ± 0.1
7.4
(BOTTOM VIEW)
q
w
e
r
t
y
INPUT VOLTAGE
INPUT VOLTAGE
GND
HV ADJ
HV OUTPUT
GND
NOTE AAt maximum output voltage.
BAt maximum output voltage and current.
Dimensional Outlines (Unit: mm) Output Voltage Controlling Characteristic
TACCA0124EA
TACCB0009EA
Compact High Voltage Power Supply Units C4710 Series
The C4710 series comprises on-board type high voltage power
supply units, designed specifically for photomultiplier tube op-
erations. The C4710 series is designed for ease of use and high
performance, and can be selected from among 6 models to meet
your various needs.
FEATURES
Compact and lightweight
High stability
High output voltage up to 1500 V
Ample protective functions
Fully enclosed metal-shielded package
Specifications
C4710 C4710-01 C4710-02 C4710-50 C4710-51 C4710-52
Input Voltage +15±1+12±1+24±1+15±1+12±1+24±1V dc
Input Current Awith no load 95 120 65 95 120 65
with full load 260 340 145 260 340 145
Specification Guaranteed Output Voltage Range
-
240 to
-
1500 +240 to +1500 V dc
Output Current 1 mA Max.
Line Regulation against ±1 V Input Change
B±0.01 ±0.015 ±0.015 ±0.02 ±0.02 ±0.015 % Typ.
Load Regulation against 0 % to 100 % Load Change
A±0.01 ±0.015 ±0.01 ±0.01 ±0.01 ±0.01 % Typ.
Ripple/Noise (p-p) B0.005 % Typ.
Output Voltage Control By external controlling voltage (+0.8 V to +5 V) or external potentiometer (10k)
Controlling Voltage Input Impedance
40 56 k Typ.
Output Voltage Setting (Absolute Value)
(Controlling Voltage ×300) ±0.5% V Typ.
Output Voltage Rise Time (0 %99 %)
B100 ms Typ.
Temperature Coefficient B±0.01 %/°C Typ.
Operating Temperature B0 to +40 °C
Storage Temperature
-
20 to +60 °C
Weight 105 g
27.5 8
1
5
35
45
10
25
2-MOUNTING THREADS (M2.3)
65
55
45
1
2
3 HV ADJ
4
5HV OUT
+12/15/24 V dc IN
COMMON
V
REF
OUT
(BOTTOM VIEW)(SIDE VIEW)
1
CONTROLLING VOLTAGE
OUTPUT VOLTAGE (V)
+1800
0
+300
+600
+900
+1200
+1500
23456
5.3
1800
0
300
600
900
1200
1500
(C4710, 01, 02) (C471050, 51, 52)
OUTPUT VOLTAGE (V)
0.430
Parameter Unit
Protective Functions
Units protected against reversed power input, reversed/ excessive controlling voltage input,
continuous overloading/short circuit in output.
mA Typ.