3
www.power-one.com
Safety
Approvals EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment class I
Protection degree IP 20/30
Electric strength test voltage I/case, O/case, Out OK/case 1.5 kV AC
I/O, Out OK/I, Out OK/O 3 kV AC
O/O 300 V DC
EMC
Electrostatic discharge IEC/EN 61000-4-2, level 4 (8/15 kV) criterion B
Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A
Electr. fast transients/bursts IEC/EN 61000-4-4, output/input, level 3/4 (2/4 kV) criterion B
Surge IEC/EN 61000-4-5, input, level 2/3 (1/2 kV) criterion B
Conducted disturbances IEC/EN 61000-4-6, level 2/3 (3/10 V) criterion A
Electromagnetic emissions CISPR 22/EN 55022, 24/48/BQ/CQ/GQ, conducted class B
Environmental –2 units
Operating ambient temperature
U
i nom,
I
o nom, convection cooled –10...50°C
Operating case temperature
T
C
U
i nom,
I
o nom –10...80°C
Storage temperature non operational –25...100°C
Damp heat IEC/EN 60068-2-3, 93%, 40°C 21 days
Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.15 mm/2 gn
Shock IEC/EN 60068-2-27, 6 ms 15 gn
Bump IEC/EN 60068-2-29, 6 ms 10 gn
MTBF MIL-HDBK-217F, GB, 40°C, 24/48Q1000 588'000 h
Environmental –7 units
Operating ambient temperature
U
i nom,
I
o nom, convection cooled –25...71°C
U
i nom,
I
o max, convection cooled –25...50°C
Operating case temperature
T
C
U
i nom,
I
o nom –25...95°C
U
i nom,
I
o max –25...85°C
Storage temperature non operational –40...100°C
Damp heat IEC/EN 60068-2-3, 93%, 40°C 56 days
Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.35 mm/5 gn
Shock IEC/EN 60068-2-27, 11 ms 50 gn
Bump IEC/EN 60068-2-29, 11 ms 25 gn
Random vibration IEC/EN 60068-2-64, 20...500 Hz 4.9 gn rms
MTBF MIL-HDBK-217F, notice 2, GB, 40°C, BQ 2000 853'000 h
Options
Extended temperature range –40...71°C, ambient, operating, for -7 units -9
Output voltage adjustment ±10%
U
o nom, excludes feature R and vice versa P
Accessories
Front panels for 19” rack mounting in 3U or 6U configuration (Schroff/Intermas)
Mating H15 connectors with screw, solder, fast-on or press-fit terminals
Connector retention facilities and code key system for connector coding
Additional external input or output filters
Mechanical mounting supports for chassis, DIN-rail and PCB mounting
Q Series 60...132 Watt DC-DC Converters