CSM_H8PS_DS_E_6_3
1
Cam Positioner
H8PS
This Compact Cam Positioner, Popular for Its
Ease-of-use, Now Comes with Even Better
Functions.
Compact 8-, 16-, and 32-output Models available that are 1/4-
DIN size at 96 x 96 mm.
High-speed operation at 1,600 r/min and high-precision settings
to 0.5° ensure widespread application.
Highly visible display with backlit negative transmissive LCD.
Advance angle compensation function to compensate for output
delays.
Bank function for multi-product production (8 banks).
(H8PS-16@/-32@ models.)
Speed display and pulse output.
Approved standards: UL/CSA and EMC.
Refer to Safety Precautions for All Counters and
Safety Precautions on page 18 and 19.
Features
Models with 8, 16, or 32 Outputs
The lineup includes Models with 32 outputs in a compact 1/4-DIN
size. Using the optional Parallel Input Adapter (Y92C-30) enables
expanding to up to 64 outputs for one encoder to support anything
from a simple positioning application to a large-scale system.
Simple Programming
The programming method is designed based on a one key-one
action concept for settings that could not be simpler. Both initial
settings and factory adjustments are effort-free.
Large, Backlit Negative LCDs
Large LCDs, red for the process value and green for set values, show
a wealth of operation information, making operating status visible at
a glance.
High Speed Up To 1,600 r/min
High Precision Up To 0.5° (at 720 Resolution)
High-speed, high-precision applications can be easily handled and
productivity increased.
Bank Function for Multi-product Production
Up to eight different programs can be registered in advance to
enable fast and easy switching between products (16/32-output
Models only).
USB Communications for Easy Setting from
a Computer
Optional Support Software can be used to enable programming from
a personal computer via USB communications. Programs can be
easily copied, saved, printed, and much more.
Speed Display and Speed Alarm Output
Both the speed (rotations/minutes) and present angular position can
be displayed at the same time. Alarm outputs can be produced for
both upper and lower speed limits.
Advance Angle Compensation Function to
Compensate for Output Delays
The advance angle compensation (ADV) function automatically
advances the ON/OFF angle of outputs in proportion to machine
(encoder) speed to compensate for the delay in timing of ON/OFF
operation. ADV values can be set individually for 7 cam outputs.
Pulse Output for Timing Control
The number of pulses per rotation and the pulse output start angle
can be set to enable operations like adjusting timing with a PLC or
outputting to a rotation meter.
8-output Models 16-output Models 32-output Models
96 mm
96 mm
CAM STEP
12 7
RUN
CAM STEP
12 7
RUN
Switchable
Present angular
position
Speed
Speed
Present angular
position
Speed
Upper limit
alarm output
Lower limit
alarm output
Upper limit
Lower limit
Errors
Cam program settings
100°8° compensation 180°
92°172°
At high-speed (400 r/min)
Pulse output PLC
Rotation meter
H8PS
2
Model Number Structure
Model Number Legend
Ordering Information
List of Models
Cam Positioner
Dedicated Absolute Encoder
Accessories (Order Separately)
Note: Ask your OMRON representative about the availability of non-standard lengths.
Recommended USB Cables
Note: If you can’t purchase recommended replacement, please purchase commercially available USB cable that attached ferrite core.
1234
H8PS-@@@@
1. Number of outputs
8: 8 outputs
16: 16 outputs
32: 32 outputs
2. Panel language
B: English
3. Mounting method
None: Flush mounting
F: Surface mounting/
track mounting
4. Output configuration
None: NPN transistor output
P: PNP transistor output
Number of outputs Mounting method Output configuration Bank function Model
8 outputs Flush mounting NPN transistor output No H8PS-8B
PNP transistor output H8PS-8BP
Surface mounting/
track mounting
NPN transistor output H8PS-8BF
PNP transistor output H8PS-8BFP
16 outputs Flush mounting NPN transistor output Yes H8PS-16B
PNP transistor output H8PS-16BP
Surface mounting/
track mounting
NPN transistor output H8PS-16BF
PNP transistor output H8PS-16BFP
32 outputs Flush mounting NPN transistor output H8PS-32B
PNP transistor output H8PS-32BP
Surface mounting/
track mounting
NPN transistor output H8PS-32BF
PNP transistor output H8PS-32BFP
Type Resolution Cable length Model
Economy 256 2 m E6CP-AG5C-C 256P/R 2M
Standard 256 1 m E6C3-AG5C-C 256P/R 1M
2 m E6C3-AG5C-C 256P/R 2M
360 E6C3-AG5C-C 360P/R 2M
720 E6C3-AG5C-C 720P/R 2M
Rigid 256 2 m E6F-AG5C-C 256P/R 2M
360 E6F-AG5C-C 360P/R 2M
720 E6F-AG5C-C 720P/R 2M
Name Specification Model
Discrete Wire Output Cable 2 m Y92S-41-200
Connector-type Output Cable 2 m E5ZE-CBL200
Support Software CD-ROM H8PS-SOFT-V1
Shaft Coupling for the E6CP Axis: 6 mm dia. E69-C06B
Shaft Coupling for the E6C3 Axis: 8 mm dia. E69-C08B
Shaft Coupling for the E6F Axis: 10 mm dia. E69-C10B
Extension Cable (See note.) 5 m (same for E6CP, E6C3, and E6F) E69-DF5
Parallel Input Adapter Two Units can operate in parallel. Y92C-30
Protective Cover --- Y92A-96B
Watertight Cover --- Y92A-96N
Track Mounting Base --- Y92F-91
Mounting Track 50 cm × 7.3 mm (l × t) PFP-50N
1 m × 7.3 mm (l × t) PFP-100N
1 m × 16 mm (l × t) PFP-100N2
End Plate --- PFP-M
Spacer --- PFP-S
Name Recommended manufacturer Specification Model
USB Cable ELECOM CO.Ltd. A-miniB, 2m U2C-MF20BK
H8PS
3
Specifications
Ratings
Item H8PS-@B H8PS-@BF H8PS-@BP H8PS-@BFP
Rated supply voltage 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Mounting method Flush mounting Surface mounting,
track mounting
Flush mounting Surface mounting,
track mounting
Power consumption Approx. 4.5 W at 26.4 VDC for 8-output models
Approx. 6.0 W at 26.4 VDC for 16-/32-output models
Inputs Encoder input Connections to a dedicated absolute encoder
External
inputs
Input
signals
8-output Models: None
16-/32-output Models: Bank inputs 1/2/4, origin input, start input
Input type No voltage inputs: ON impedance:1 kΩ max. (Leakage current: approx. 2 mA at 0 Ω)
ON residual voltage: 2 V max., OFF impedance: 100 kΩ min., Applied voltage: 30 VDC max.
Minimum input signal width: 20 ms
Outputs Cam outputs
RUN output
NPN open-collector transistor outputs
30 VDC max.,
100 mA max. (Do not exceed 1.6 A total for all cam
outputs and the RUN output.),
residual voltage: 2 VDC max.
PNP open-collector transistor outputs
30 VDC max. (26.4 VDC for 16-/32-output Models),
100 mA max. (Do not exceed 1.6 A total for all cam
outputs and the RUN output.),
residual voltage: 2 VDC max.
Pulse output NPN open-collector transistor output
30 VDC max.,
30 mA max.,
residual voltage: 0.5 VDC max.
PNP open-collector transistor output
30 VDC max. (26.4 VDC for 16-/32-output Models)
30 mA max.,
residual voltage: 2 VDC max.
Number of outputs 8-output Models: 8 cam outputs, 1 RUN output, 1 pulse output
16-output Models: 16 cam outputs, 1 RUN output, 1 pulse output
32-output Models: 32 cam outputs, 1 RUN output, 1 pulse output
Number of banks 8 banks (for 16-/32-output Models only)
Display method 7-segment, negative transmissive LCD (Main Display: 11 mm (red), Sub-display: 5.5 mm (green))
Memory backup method EEPROM (overwrites: 100000 times min.) that can store data for 10 years min.
Ambient operating
temperature
10 to 55°C (with no icing or condensation)
Storage temperature 25 to 65°C (with no icing or condensation)
Ambient humidity 25% to 85%
Degree of protection Panel surface: IP40, Rear case: IP20
Case color Light gray (Munsell 5Y7/1)
H8PS
4
Characteristics
Note: 1. Cam output precision, however, is 2° max. for Encoder with 256 resolution (P/R).
2. Although 32-output Models can have 10 steps set for any one output, there must be no more than 160 steps total set for all cam outputs.
3. The maximum is 1000 r/min when an E6CP-AG5C-C Encoder is connected.
4. ADV stands for Advance Angle Compensation.
Setting unit 0.5° increments at a resolution of 720, 1° increments at a resolution of 256 or 360 (See note 1.)
Number of steps Up to 10 steps can be set for each cam to turn the output ON/OFF 10 times. (See note 2.)
Inputs Encoder input Connections to a dedicated absolute encoder
Response rotation speed (in Run/Test Mode)
1600 r/min max. at a resolution of 256 or 360 (1200 r/min max. if ADV function is set for 4 or more cams)
(See notes 3 and 4.)
800 r/min max. at a resolution of 720 (600 r/min max. if ADV function is set for 4 or more cams)
Includes error data detection
Encoder cable extension
distance
256/360 resolution
100 m max. at 330 r/min or less
52 m max. at 331 to 1200 r/min (331 to 900 r/min if ADV function is set for 4 or more cams)
12 m max. at 1201 to 1600 r/min (901 to 1200 r/min if ADV function is set for 4 or more cams)
720 resolution
100 m max. at 330 r/min or less
52 m max. at 331 to 600 r/min (331 to 450 r/min if ADV function is set for 4 or more cams)
12 m max. at 601 to 800 r/min (451 to 600 r/min if ADV function is set for 4 or more cams)
Output response time 0.3 ms max.
Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-carrying metal
parts, between all current-carrying parts and the USB connector
Dielectric strength 1000 VAC, 50/60 Hz for 1 min between current-carrying terminals and exposed non-current-carrying metal
parts
500 VAC, 50/60 Hz for 1 min between current-carrying section and USB connector, and between current-
carrying terminals and non-current-carrying metal part of output connector
Impulse withstand voltage 1 kV between power terminals
1.5 kV between current-carrying terminals and exposed non-current-carrying metal parts
Noise immunity ±480 V between power terminals, ±600 V between input terminals
Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity 8 kV (malfunction), 15 kV (destruction)
Vibration
resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each
Malfunction 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each
Shock
resistance
Destruction 300 m/s2 3 times each in 6 directions
Malfunction 200 m/s2 3 times each in 6 directions
Approved safety standards cULus (Listing): UL508/CSA C22.2 No. 14
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group1 Class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge
8 kV air discharge
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance EN61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst: EN61000-4-4: 2 kV for power-line
1 kV for I/O signal-line
Immunity Surge: EN61000-4-5: 1 kV line to line (power line)
2 kV line to ground (power line)
Weight Approx. 300 g (Cam Positioner main unit only)
H8PS
5
Functions
Item H8PS-8@H8PS-16@H8PS-32@
Encoder rotation direction
switching
Encoder data can be set with a DIP switch to forward (CW) or reverse (CCW) direction.
Encoder origin designation The present display angular
position can be set to 0° (origin) by
pressing the ORIGIN Key on the
front panel.
The present display angular position can be set to 0° (origin) by using the
origin input terminal or the ORIGIN Key on the front panel.
Note: All banks use the same origin.
Angle display switch Converts the Absolute Encoder value display from 256 divisions/revolution to 360°/revolution.
Rotation display monitor Graphically displays the Encoder rotational angular position.
Teaching function Sets the cam output ON/OFF angle based on actual machine (Encoder) operation.
Pulse output Outputs a preset number of pulses per Encoder rotation. It also sets the pulse output start angle.
Switching the angle and
speed displays
Displays both the present angular position and the number of Encoder revolutions (speed) in Run Mode.
Switches back and forth between the main display showing the present angular position with the sub-display
showing the speed and the main display showing the speed with the sub-display showing the present angular
position.
Bank function --- Enables the entire cam program to be changed at one time by switching
banks (0 to 7).
The bank that is running can be switched using the bank input terminal or the
BANK Key on the front panel.
Also enables programs to be copied between banks.
Advance angle compensation
(ADV) function
Automatically advances the ON/OFF angle of cam outputs in proportion to machine (encoder) speed to
compensate for the delay in timing of ON/OFF operation. ADV values can be set individually for 7 cam outputs.
Speed alarm output A specified cam output can be used as an Encoder speed alarm output.
The function can output upper and lower limit speed alarms.
All protection function Disables all key and switch operations in Run Mode to prevent incorrect or unauthorized operation.
Cam protection function Prohibits program changes at the cam output level. Any cam numbers can be protected.
Step number limit Limits the number of steps that can be set per cam output. Prohibits incorrect operations by adding to the
program.
Output prohibit --- The start input can be turned OFF in Run or Test Mode to prohibit cam
output.
Note: Use this function carefully for the application because no cam outputs
are provided when the start input is turned OFF.
Support Software settings --- Programs can be uploaded or downloaded easily by connecting a personal
computer to the Cam Positioner using a USB Cable (Recommended USB
Cables: ELECOM CO.Ltd. U2C-MF20BK) and the Support Software (H8PS-
SOFT-V1, sold separately).
H8PS
6
Connections
Terminal Arrangement
Note: For PNP output models, the VS terminal and power supply terminals are not connected internally.
H8PS-8@ (8-output Models) H8PS-16@/-32@ (16-/32-output Models)
Encoder
12345678
910111213
24 VDC
+
Alignment markings
(Rear view)
Pulse output
RUN output
Not used
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
NPN Output,
Flush Mounting
H8PS-8@
Encoder
6789 10111213
12345
Alignment markings
(Rear view)
24 VDC
+
Bank 1
Bank 2
Bank 4
Origin
Start
Not used
Not used
Not used
Pulse output
RUN output
COM
12345678
910111213
24 VDC
+
Encoder
Alignment markings
(Front view)
Pulse output
RUN output
Not used
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
NPN Output,
Surface Mounting
H8PS-8@F
678910111213
12345
24 VDC
+
Encoder
Alignment markings
(Front view)
Bank 1
Bank 2
Bank 4
Origin
Start
Not used
Not used
Not used
Pulse output
RUN output
COM
NPN Output,
Surface Mounting
H8PS-16@F/-32@F
12345678
9 10111213
24 VDC
+
Encoder
Alignment markings
(Rear view)
Pulse output
RUN output
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
Vs (See note.)
PNP Output,
Flush Mounting
H8PS-8@P
Note: The VS terminal
is not internally
connected to the
positive (+) power
supply terminal.
6789 10111213
12345
24 VDC
+
Encoder
Alignment markings
(Rear view)
Bank 1
Bank 2
Bank 4
Origin
Start
Not used
Not used
Vs (See note.)
Pulse output
RUN output
COM
PNP Output,
Flush Mounting
H8PS-16@P/-32@P
Note: The VS terminal
is not internally
connected to
the positive (+)
power supply
terminal.
12345678
9 10111213
24 VDC
+
Encoder
Alignment markings
(Front view)
Pulse output
RUN output
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
Vs (See note.)
PNP Output,
Surface Mounting
H8PS-8@FP
Note: The VS terminal
is not internally
connected to the
positive (+) power
supply terminal.
6789 10111213
12345
24 VDC
+
Encoder
Alignment markings
(Front view)
Bank 1
Bank 2
Bank 4
Origin
Start
Not used
Not used
Vs (See note.)
Pulse output
RUN output
COM
PNP Output,
Surface Mounting
H8PS-16@FP/-32@FP
Note: The VS terminal
is not internally
connected to the
positive (+) power
supply terminal.
H8PS
7
Output Cable Connections (16-/32-output Models Only)
1. E5ZE-CBL200 Connector-type Output Cable (Order Separately) Connections
Output Cable 1 Wiring Table Output Cable 2 Wiring Table
Note: 1.
The COM pins in the output connectors are connected inside the Cam Positioner to the negative terminal of the 24-VDC power supply input.
2.
The Vs pins in the output connectors are connected inside the Cam Positioner to the Vs terminal.
3. The Vs pins in the output connectors are not used on models with NPN outputs.
4.
The COM pins in output connector 1 and output connector 2 are connected to each other inside the Cam Positioner. The Vs pins in output connector 1
and output connector 2 are also connected to each other inside the Cam Positioner.
Output Connector 1 (CN1) Output Connector 2 (CN2) (See note.)
Output Connector 1 (CN1) Output Connector 2 (CN2) (See note.)
(Bottom view) (Bottom view)
Note: The 16-output Models do not have CN2 Connectors.
Output Connector Output signals
Output Connector 1 (CN1) Cam 1 to Cam 16, COM, Vs
Output Connector 2 (CN2) (See note.) Cam 17 to Cam 32, COM, Vs
Flush Mounting Models Surface Mounting Models
(CN1)
E5ZE-CBL200
Connector-type
Output Cable
(Order Separately)
H8PS-16@/-32@
(CN2)
XG4M-2030
MIL Connector
(made by OMRON)
1 3 5 7 9 1113151719
246810 12 14 16 1820
Pin Arrangement of XG4M-2030 Connectors
Output
Cable 1
Output
Cable 2
Outputs Connector
pin No.
Outputs Connector
pin No.
Cam 1 20 Cam 9 19
Cam 2 18 Cam 10 17
Cam 3 16 Cam 11 15
Cam 4 14 Cam 12 13
Cam 5 12 Cam 13 11
Cam 6 10 Cam 14 9
Cam 7 8Cam 15 7
Cam 8 6Cam 16 5
COM 4COM 3
Vs 2Vs 1
Outputs Connector
pin No.
Outputs Connector
pin No.
Cam 17 20 Cam 25 19
Cam 18 18 Cam 26 17
Cam 19 16 Cam 27 15
Cam 20 14 Cam 28 13
Cam 21 12 Cam 29 11
Cam 22 10 Cam 30 9
Cam 23 8Cam 31 7
Cam 24 6Cam 32 5
COM 4COM 3
Vs 2Vs 1
H8PS
8
Using Connector-Terminal Block Conversion Units
2. Y92S-41-200 Discrete Wire Output Cable (Order Separately) Connections
A1 A2 A3 A4 A5 A6 A7 A8A9 A10
B1 B2 B3 B4 B5 B6 B7 B8B9 B10
A1 A2 A3 A4 A5 A6 A7 A8A9 A10
B1 B2 B3 B4 B5 B6 B7 B8B9 B10
XW2D-20G6
Connector-Terminal Block
Conversion Unit (Order Separately)
H8PS-16@/-32@
(CN1)
E5ZE-CBL200
Connector-type
Output Cable
(Order Separately)
Output Cable 1
Terminal Arrangement of the XW2D-20G6 Connector-Terminal Block Conversion Unit
Output Cable 2
Output Cable 2Output Cable 1
(CN2)
Vs
Vs
COM
COM
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
Cam 9
Cam 10
Cam 11
Cam 12
Cam 13
Cam 14
Cam 15
Cam 16
Vs
COM
Cam 17
Cam 18
Cam 19
Cam 20
Cam 21
Cam 22
Cam 23
Cam 24
Vs
COM
Cam 25
Cam 26
Cam 27
Cam 28
Cam 29
Cam 30
Cam 31
Cam 32
H8PS-16@/-32@
(CN1)
Y92S-41-200
Discrete Wire
Output Cable
(Order Separately)
Output Cable 2 Output Cable 1
(CN2)
Output Cable 1 Wiring Table
Output Cable 2 Wiring Table
Outputs Cable
color
Marks Marking
color
Outputs Cable
color
Marks Marking
color
Cam 1 Orange Black Cam 9 Orange Red
Cam 2 Gray Black Cam 10 Gray Red
Cam 3 White Black Cam 11 White Red
Cam 4 Yellow Black Cam 12 Ye l l o w Red
Cam 5 Pink Black Cam 13 Pink Red
Cam 6 Orange Black Cam 14 Orange Red
Cam 7 Gray Black Cam 15 Gray Red
Cam 8 White Black Cam 16 White Red
COM Yellow Black COM Ye l l o w Red
Vs Pink Black Vs Pink Red
Outputs Cable
color
Marks Marking
color
Outputs Cable
color
Marks Marking
color
Cam 17 Orange Black Cam 25 Orange Red
Cam 18 Gray Black Cam 26 Gray Red
Cam 19 White Black Cam 27 White Red
Cam 20 Yellow Black Cam 28 Ye l l o w Red
Cam 21 Pink Black Cam 29 Pink Red
Cam 22 Orange Black Cam 30 Orange Red
Cam 23 Gray Black Cam 31 Gray Red
Cam 24 White Black Cam 32 White Red
COM Yellow Black COM Ye l l o w Red
Vs Pink Black Vs Pink Red
H8PS
9
Input Connections
Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs.
No-voltage Inputs
No-voltage Input Signal Levels
Note: Use a maximum DC power supply of 30 V.
Output Connections
Note: Internal circuit damage may result from a short circuit in the load.
NPN Output Models
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
PNP Output Models
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
H8PS-16@
H8PS-32@6 7 89
10 11
Note: Operates when the contact turns ON.
COM
Bank 1
Bank 2
Bank 4
Origin
Start
Sensor, etc.
H8PS-16@
H8PS-32@6 7 89
10 11
Note: Operates when the transistor turns ON.
COM
Bank 1
Bank 2
Bank 4
Origin
Start
H8PS-16@
H8PS-32@
Note: Operates when the transistor turns ON.
PLC,
sensor,
etc.
6 7 89
10 11
COM
Bank 1
Bank 2
Bank 4
Origin
Start
Open Collector Contact Input Voltage-output sensors can also be connected.
Connection Examples
No-contact inputs Short-circuit level for transistor ON
Residual voltage: 2 V max.
Impedance when ON: 1 kΩ max.
(The leakage current is approx. 2 mA
when the impedance is 0 Ω.)
Open level for transistor OFF
Impedance when OFF: 100 kΩ min.
Contact inputs Use a contact that can adequately switch
2mA at 5 V.
Item Cam outputs,
RUN output
Pulse output
Output method NPN open collector
Dielectric strength 30 VDC
Rated current 100 mA (See note.) 30 mA
Residual voltage 2 VDC max. 0.5 VDC max.
Leakage current 100 μA max. 5 μA max.
Note: Always connect a diode to absorb
counter-electromotive force when
connecting an inductive load.
Load
Outputs
COM/()
(See note.)
Item Cam outputs,
RUN output
Pulse output
Output method PNP open collector
Dielectric strength 8-output Models: 30 VDC
16-/32-output Models: 26.4 VDC
Rated current 100 mA (See note.) 30 mA
Residual voltage 2 VDC max.
Leakage current 100 μA max.
Vs (See note 2.)
Load
Outputs
COM/()
(See note 1.)
Note: 1. Always connect a diode to absorb counter-electromotive force when
connecting an inductive load.
2. The VS terminal and power supply terminals are not connected internally.
H8PS
10
Operating Mode
Functions
The H8PS Cam Positioner receives angle signal inputs from the Dedicated Absolute Encoder and outputs the preset ON/OFF angles as cam outputs.
Program Examples
1. H8PS-8@ (8-output Models)
2. H8PS-16@ /-32@ (16-/32-output Models)
Note: The entire cam program can be changed at one time with 16- and 32-output Models with the bank function (banks 0 to 7).
For details on the procedure for switching banks, refer to page 29.
Cam output
(cam number)
Step 0 Step 1 Step 9
ON angle OFF angle ON angle OFF angle ON angle OFF angle
145°90°135°225°270°315°
20°90°135°180°--- ---
890°225°270°285°315°345°
Cam output 1
Cam output 2
Cam output 8
Pulse output
(See note 1.)
RUN output
Note 1: The number of pulses per Encoder rotation
and the pulse output start angle can be set.
Note 2: With counterclockwise rotation (359°, 358°
...1°, 0°), step 0 for cam output 1 turns ON
at 89° and OFF at 44° at in the diagram.
0°45°90°135°180°225°270°315°0°45°
Step 1 Step 9
Step 0
Step 0
Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)
(ON/OFF ratio 1:1)
ON during Run or Test Mode. OFF when an error occurs.
Step 1
Step 1 Step 9
Step 0
Cam output 1
Cam output 2
Cam output 32
Pulse output
(See note 1.)
RUN output
Start input
(See note 2.)
Note 1: The number of pulses per Encoder rotation
and the pulse output start angle can be set.
Note 2: Be sure to turn ON the start input in Run and
Test modes. Otherwise, there will be no
outputs (output prohibited), including the cam
outputs, pulse output, and RUN output.
Note 3: With counterclockwise rotation (359°, 358°
...1°, 0°), step 0 for cam output 1 turns ON at
89° and OFF at 44° in the diagram.
0°45°90°135°180°225°270°315°0°45°
Step 0
Step 0
Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)
(ON/OFF ratio 1:1)
ON during Run or Test Mode. OFF when an error occurs.
Step 1
Step 1 Step 9Step 0
Step 1 Step 9
Cam Program (Bank No. 7)
Cam Program (Bank No. 2)
Cam Program (Bank No. 1)
Cam Program (Bank No. 0)
Cam output
(cam number)
Step 0 Step 1 Step 9
ON angle OFF angle ON angle OFF angle ON angle OFF angle
1 45°90°135°225°270°315°
20°90°135°180°--- ---
32 90°225°270°285°315°345°
H8PS
11
Nomenclature
Displays
Operation Keys
8-output Models
16-/32-output Models
Display Details
No. Display
color
Description
(1) Orange Lit while cam outputs are ON.
(2) Red PV: Lit while the present angular position or speed is displayed in
main display.
SV: Lit while the setting value is displayed in main display.
(3) Orange Lit while the start input is ON in Run or Test Mode.
Not lit when an error occurs.
(4) Orange Displays Encoder present angular position, direction, and speed
guidelines.
(5) Green Displays the bank number that is running in Run or Test Mode and
the bank number selected in Programming Mode.
(6) Green Displays the cam number for the angle setting displayed on sub-
display.
(7) Green Displays the step number for the angle setting displayed on sub-
display.
(8) Orange Lit while the All Protection function is enabled.
(9) Orange The indicator for the selected mode is lit.
PRG: Programming Mode
TST: Test Mode
RUN: Run Mode
(10) Red Displays the present angular position or the speed and settings
being made.
(11) Red Displays units for the angle or the speed displayed on main display.
(12) Red Lit while using an Encoder with a resolution of 256 if 256° display is
selected.
(13) Green Displays units for the angle or the speed displayed on sub-display.
(14) Green Displays the speed or the ON/OFF angle settings.
(15) Green Indicates whether main display displays the ON or OFF angle
setting.
(16) Green Lit while setting the Advance Angle Compensation (ADV) Function.
CAM STEP
(1) Cam output indicators
(2) PV/SV indicator
(4) Rotation display
monitor
(6) Cam No. display
(7) Step No. display
(8) All protect
indication
(9) Mode indicator
(10) Main display
(11) Unit indication
(13) Unit indication
(12) 256 indication
(14) Sub-display
(15) ON/OFF
indication
(16) ADV indication
12345678PRG
TST
RUN
CAM STEP
(8) All protect
indication
(9) Mode indicator
(10) Main display
(11) Unit indication
(13) Unit indication
(12) 256 indication
(14) Sub-display
(15) ON/OFF
indication
(16) ADV indication
12345678910 PRG
TST
RUN
11 12 13 14 15 16 17 1819 20
21 22 23 24 25 26 27 2829 30
31 32
(3) Start input
indication
(5) Bank No. display
(2) PV/SV indicator
(4) Rotation display
monitor
(6) Cam No. display
(7) Step No. display
(1) Cam output indicators
8-output Models
16-/32-output Models
Operation Key Details
No. Description
1 Displays program details in Run Mode.
2Selects the cam number with Keys.
3Selects the step number with Keys.
4 Selects the bank number.
5 Selects the ON angle, or OFF angle
6 Writes the set data to memory.
7Changes the angle or other setting value with Keys.
8 Connects the Cam Positioner to a personal computer via USB cable (order
separately) for programming with the Support Software (order separately).
9 Moves to the screen for clearing settings
10 Designates the current angle of the machine (Encoder) as the origin (0°).
11 Programming or Test Mode: Press to shift to the ADV function setting
screen.
Programming Mode: Press and hold at least 3 s to shift to the Function
Setting Mode.
Run Mode: Press and hold at least 5 s to enable/disable the All Protection
function.
12 Switches modes.
Programming Mode (PRGM):
Used to write cam programs, set the ADV function,
etc.
Test Mode (TEST): Used to modify settings while the Encoder is running.
Run Mode (RUN): Used for normal operation and to check the cam
program.
13 Select the method used for programming cams.
Teaching: ON/OFF Angles can be set based on actual machine (Encoder)
operation.
Manual: ANGLE Keys can be used to set ON/OFF angles.
14 Sets the H8PS rotation direction (rotation display monitor, etc.) to the
machine (Encoder) rotation direction.
15 Sets the resolution of the connected Encoder.
Also sets the unit for angle display when using an Encoder with a
resolution of 256.
ORIGIN
CHECK
CAM
STEP
CLEAR
ANGLE
ADV
WRITE
DO NOT USE.
CW
CCW
PLS/R ANG
DSPL
CAM STEP
1. CHECK key
2. CAM keys
3. STEP keys
5. ON/OFF key
6. WRITE key
7. ANGLE keys
9. CLEAR key
10. ORIGIN key
13. Programming
mode switch
15. Encoder resolution
switch
12. Mode switch
PRGM
TEST
RUN
TCH
MAN
ONOFF
OFF
ON
4321
OFF
OFF
ON
ON
OFF
ON
OFF
720 360
360360
360256
256256
ON
43
11. ADV key
14. Rotation direction
switch
1. CHECK key
2. CAM keys
3. STEP keys
5. ON/OFF key
6. WRITE key
7. ANGLE keys
9. CLEAR key
10. ORIGIN key
8. USB connector
4. BANK key
ONOFF
OFF
ON
4321
OFF
OFF
ON
ON
OFF
ON
OFF
720 360
360360
360256
256256
ON
43 ORIGIN
CHECK
CAM
STEP
CLEAR
ANGLE
ADV
WRITE
DO NOT USE.
CW
CCW
PLS/R ANG
DSPL
CAM STEP
PRGM
TEST
RUN
TCH
MAN
BANK
13. Programming
mode switch
15. Encoder resolution
switch
12. Mode switch
14. Rotation direction
switch
11. ADV key
H8PS
12
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Main Unit
Cam Positioners
52.9
46
(14.6) 12
91.8 × 91.8
15.2
M3.5 terminal screw
96
96
21.6
52.9
46
(14.6) 12
91.8 × 91.8
15.2
M3.5 terminal screw
96
96
21.6
14.6
Mounting panel
(1 to 5 mm)
α
52.9
52.3 + α
11 dia.
Mounting bracket (included)
Mounting screws
(2 included) (M4 x 12)
92
+0.8
0
92
+0.8
0
Flush Mounting Models
H8PS-8B@ (8-output Models)
Panel Cutout
(according to DIN 43700)
Note: Mounting panel thickness must be 1 to
5 mm. Flush mounting
Note: An 8-output Model is shown in the above
diagrams. The Encoder is connected
from the bottom with 16-/32-output
Models.
H8PS-16B@ (16-output Models)
H8PS-32B@ (32-output Models)
115.2±
0.3
Four, M4 tap holes
81.8±
0.2
74.4
(See note 1.)
60.6
DIN Track
DIN Track Mounting Base
Y92F-91
(Order Separately)
16 16
(60.6)
58
46
22.9
16
91.8 × 91.8
M3.5 terminal screw
96
96
90
121.2
Terminal cover
M3.5 terminal screw
96
96
90
(60.6)
58
46
16
121.2
22.9
91.8 × 91.8
Terminal cover
Mounting holes
Surface
Mounting
Note: 1. These dimensions vary with the kind
of DIN track (reference value).
2. An 8-output Model is shown in the
above diagrams. The Encoder is
connected from the bottom with 16-/
32-output Models.
H8PS-16BF@ (16-output Models)
H8PS-32BF@ (32-output Models)
Track
Mounting
Surface Mounting Models
H8PS-8BF@ (8-output Models)
H8PS
13
Encoder Connecting Direction
Accessories (Order Separately)
Parallel Input Adapters
Y92C-30
This Adapter enables two H8PS Cam Positioners to share signals
from an Encoder.
Note: H8PS has been improved in 2004 April.
Do not mix old and new model with Y92C-30.
When you use 2 x H8PS, please use by "Old & Old" or "New &
New" models.
Use the cable marked with a triangle when connecting only one
H8PS Cam Positioner to the Parallel Input Adapter.
Panel Surface Mounting
Panel Back Mounting
Encoder
Output cable
Encoder
Encoder
Output cable
Encoder
H8PS-8B@H8PS-8BF@H8PS-16B@
H8PS-32B@H8PS-16BF@
H8PS-32BF@
Connected to the H8PS. Connected to the H8PS.
Y92C-30
From the Dedicated Absolute Encoder
R6.5
14 dia.36
40.4 6.5
246089
47 1,030
15 37
8.5 dia.
17 dia.
26
11.3
9
74±
1
Two, M4 tap holes
Front
M4 screw (included)
36
74±
1
Two, 4.3 dia. holes
Back
M4 screw (included)
M4 nut (included)
36
H8PS
14
Accessories (Order Separately)
CHECK
CAM STEP
CAM
STEP
Y92A-96N
Y92A-96N
92
+0.8
0
92
+0.8
0
131.7
21.9 (2)
115.6 28.9
69.3
Cover dimensions
CAM
STEP
CHECK
CAM STEP
Watertight Cover
Y92A-96N
Use for flush mounting when waterproofing is
required. The Y96A-96N conforms to IP66 and
NEMA4 (for indoor use) standards for waterproofing.
The operating environment may cause the waterproof packing to deteriorate, shrink, or harden.
Therefore, it is recommended that the packing be replaced regularly.
Panel Cutout
Protective Cover
Y92A-96B
A hardened Y92A-96B Protective Cover is
available.
Use it for the following:
To protect the front panel from dust and
dirt.
To prevents the set value from being
altered due to accidental contact with the
keys or switches.
DIN Track Mounting Base
Y92F-91
Discrete Wire Output Cable
Y92S-41-200
Cable length: 2 m
Connector-type Output Cable
E5ZE-CBL200
Cable length: 2 m
1
35±0.3
7.3±0.15
27±0.15
4.5
15 25 25
10 15 (5)*
10
25 25
* The numbers in parentheses () are dimensions for the PFP-50N.
1,000 (500)*
15 25 25
1,000
4.5
25 25 15
10 1
242735±0.3
16
1.5
29.2
10
4.8
1.3
35.5 35.3
1.8
1
1.8
10
6.2
M4 spring washer
50
11.5
M4 x 8
pan-head
screw
10
5
16
12
44.3
34.8
16.5
Mounting Track
PFP-100N
PFP-50N PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
H8PS
15
Combining this Encoder with an H8PS Cam Positioner
enables high-precision detection of the operation timing of
various automatic machines.
The E6CP-A is a low-cost, money-saving Encoder.
The standard E6C3-A is well suited to environments subject
to water and oil.
The standard E6F-A is a rigid type that is compatible with
high shaft-tolerance applications as well as environments
subject to water and oil.
Note: Refer to the relevant datasheet for details.
Ratings and Characteristics
Note: 1. The following inrush currents flow when the power is turned ON.
E6CP-AG5C-C: Approx. 8 A (time: approx. 0.3 ms),
E6C3-AG5C-C: Approx. 6 A (time: approx. 0.8 ms),
E6F-AG5C-C: Approx. 9 A (time: approx. 5 μs)
2. JEM1030: Applicable as of 1991
E6CP-A/E6C3-A/E6F-A Rotary Encoders (Absolute)
Item E6CP-AG5C-C E6C3-AG5C-C E6F-AG5C-C
Rated supply voltage 12 VDC 10% to 24 VDC +15%, ripple (p-p) 5% max.
Current consumption
(See note 1.)
70 mA max. 60 mA max.
Resolution (pulses
per rotation)
256 (8-bit) 256 (8-bit), 360 (9-bit), or 720 (10-bit)
Output code Gray binary
Output configuration NPN open-collector output
Output capacity Applied voltage: 28 VDC max.
Sink current: 16 mA max.
Residual voltage:0.4 V max.
(sink current at 16 mA)
Applied voltage: 30 VDC max.
Sink current: 35 mA max.
Residual voltage:0.4 V max.
(sink current at 35 mA)
Logic Negative logic (H = 0, L = 1)
Accuracy Within ±1°
Rotation direction Clockwise (viewed from the shaft) for output code increment
Rise and fall times of
output
1.0 μs max. (control output voltage: 16 V; load
resistance: 1 kΩ; output cord: 2 m max.)
1.0 μs max. (control output voltage: 5 V; load resistance: 1 kΩ; output cord: 2 m max.)
Starting torque 0.98 m N·m max. 10 m N·m max. (at room temperature),
30 m N·m max. (at low temperature)
9.8 m N·m max. (at room temperature),
14.7 m N·m max. (at low temperature)
Moment of inertia 1 × 106 kg·m2 max. 2.3 × 106 kg·m2 max. 1.5 × 106 kg·m2 max.
Shaft-load
tolerance
Radial 29.4 N 80 N 120 N
Thrust 19.6 N 50 N
Max. permissible
rotation
1000 r/min 5000 r/min
Ambient temperature 10 to 55°C (with no icing) 10 to 70°C (with no icing)
Storage temperature 25 to 85°C (with no icing) 25 to 80°C (with no icing)
Ambient humidity 35% to 85% (with no condensation)
Degree of protection IEC standard IP50 IEC standard IP65 (JEM standard IP65f) (See
note 2.)
IEC standard IP65 (JEM standard IP65f)
Insulation resistance 200 MΩ min. (at 500 VDC) between charged parts and the case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between charged parts and the case
Vibration resistance Destruction:
10 to 55 Hz,1.5-mm double amplitude for 2 hr
each in X, Y, and Z directions
Destruction:
10 to 500 Hz, 2-mm double amplitude, 150 m/
s2 3 times each in X, Y, and Z directions, 11-
min sweep time
Destruction:
10 to 500 Hz,1.5-mm double amplitude 3
times each in X, Y, and Z directions, 11-min
sweep time
Shock resistance Destruction: 1000 m/s2 3 times each in X, Y, and Z directions
Weight Approx. 200 g (with 2-m cord) Approx. 300 g (with 1-m cord) Approx. 500 g (with 2-m cord)
Datasheet Cat. No. --- F058 E283
H8PS
16
Dimensions
Note: All units are in millimeters unless otherwise indicated.
45°45°
38 dia.
56 dia. 50 dia.
16.9 dia.
2,000
10 50
40 37
5
3
8
1
Four, M4 holes
(depth: 10) (See note 1.)
(See note 2.)
Note 1: Round, vinyl-insulated cable
with 10 cores (external
dia.: 6, cross-sectional
area: 0.18 mm
2
, insulation:
1.0 mm dia.), standard
length: 2 m
Note 2: Connector to the H8PS
Cam Positioner.
25 dia.
0
0.2
6 dia.
0.008
0.020
8
16
5.5 dia. holes
Two, C1
(18)16
9
2
(5.1)
3.1
+0.1
0
120°
120°120°
25 dia.
Three, M5
Panel
68±0.2 dia.
E6CP-AG5C-C
Accessory
Mounting Bracket (Included) Bracket Mounting Diagram
Note: Order the E69-C06B
Coupling separately.
30 dia.
Oil-resistant, shield PVC-insulated cable with 12 cores (external dia.: 6,
cross-sectional area: 0.2 mm2, insulation: 1.1 mm dia.), standard length: 1 m or 2 m
50 dia.
D cut: Phase-Z position (range: ±15°)
40±0.1 dia.
10
Three, M4 holes
(depth: 5)
120°±0.1
120°±0.1
8 dia.
+0
0.018
+0
0.021
6
8.8
6
12 dia. 1
1
5
10
(15)
38
20
(58)
37
E6C3-AG5C-C
Note: Order the E69-C08B
Coupling separately.
8
16
5.5 dia. holes
Two, C1
(18)16
9
2
3.1+
0.1
0
(5.1)
120°
120°
120°
72±0.2 dia.
Panel
Three, M5
40 dia.
Bearings
48 dia.
24 dia.
Four, M3 holes (depth: 6)
17
1
60 dia.
54 dia.
15 3
3
20
60
(85)
5
14 max.
42.5
(See note 2.)
(See note 1.)
2,000
16.9 dia.
37
Note 1: Round, shielded vinyl-insulated cable
with 12 cores (external dia.: 6,
cross-sectional area: 0.2 mm2,
insulation: 1.1 mm dia.),
standard length: 2 m
Note 2: Connector to the H8PS Cam Positioner
10 dia.
0
0.015
40 dia.
0
0.025
E6F-AG5C-C
Bracket Mounting Diagram
Accessory
Mounting Bracket (included)
Note: Order the E69-C10B
Coupling separately.
H8PS
17
Accessories (Order Separately)
Safety Precautions for Encoders
Precautions for Correct Use
Do not subject the E6CP Encoder to oil or water.
The Encoder consists of high-precision components. Handle it with
utmost care and do not drop it, otherwise malfunctioning may
result.
When connecting the shaft of the Encoder with a chain timing belt
or gear, connect the chain timing belt or gear with the shaft via a
bearing or coupling as shown in the following diagram.
If the decentering or declination value exceeds the tolerance, an
excessive load imposed on the shaft may damage or shorten the
life of the Encoder.
Do not place excessive loads on the shaft if the shaft is connected
to a gear.
The tightening torque must not exceed the value given in the table
at the right when the Rotary Encoder is mounted with screws.
Do not pull wires with a force greater than 29.4 N while the Rotary
Encoder is secured and wired.
Do not subject the shaft to shock. Therefore, do not strike the shaft
or coupling with a hammer when inserting the shaft into the
coupling.
Make sure there is no foreign matter in the Connector before
connecting it to the Encoder.
Mounting Procedure
22
Four, M3 Hexagon
socket-head setscrews
6H8 dia.15 dia.
(11)
(16.4) 2.8
2.8
5.5 5.5
26.2
Four, M4 Hexagon
socket-head setscrews
10H8 dia.22 dia.
(12)
(19)
3.6 3.6
7.17.1
16.9 dia. 16.9 dia.
39.6
(See note 1.) (See note 3.)(See note 2.)
375,000
Note 1: E6F-AG5C-C, E6CP-AG5C-C, and E6C3-AG5C-C Connectors for the H8PS.
Note 2: 6-dia., 12-core shielded cable (cross-sectional area: 0.2 mm2, insulation: 1.1 mm dia.), standard length: 5 m
Note 3: Connected to the H8PS Cam Positioner.
8H8 dia. 8H8 dia.19 dia.
3.5 3.5
6.8 6.8
23.6
Four, M4 Hexagon
socket-head setscrews
E69-C06B Shaft Coupling (for the E6CP)
Note: The material is fiber-glass-reinforced
polybutylene terephthalate resin (PBT).
E69-C10B Shaft Coupling (for the E6F)
Note: The material is fiber-glass-reinforced
polybutylene terephthalate resin (PBT).
Note: Refer to Characteristics on page 4 for the maximum cable length.
The following models are also available: E69-DF10 (10 m), E69-DF15 (15 m), E69-DF20 (20 m), and E69-DF98 (98 m).
E69-DF5 Extension Cable
E69-C08B Shaft Coupling (for the E6C3)
Note: The material is fiber-glass-reinforced
polybutylene terephthalate resin (PBT).
Chain
sprocket
Bearings
Coupling
Rotary Encoder
Rotary Encoder
Fastening
plate
Cord
29.4 N max.
Refer to the table for
the maximum
insertion lengths of
the shaft into the
Coupling.
1 Insert the shaft into the Coupling.
2 Secure the Encoder.
3 Secure the Coupling.
4 Connect the power and I/O lines.
5 Turn ON the power and check the
outputs.
Coupling Maximum insertion length
E69-C06B 5.5 mm
E69-C08B 6.8 mm
E69-C10B 7.1 mm
Coupling Tightening torque
E69-C06B 0.25 N·m
E69-C08B 0.44 N·m
E69-C10B 0.44 N·m
Do not secure the
Coupling and shaft
with screws at this
time.
Be sure to turn
OFF the Encoder
before connecting
the lines.
H8PS
18
Safety Precautions for Cam Positioners
Refer to Safety Precautions for All Counters.
Precautions for Safe Use
Observe the following items to ensure the safe use of this product.
Environmental Precautions
Store the H8PS within specified ratings. If the H8PS has been
stored at temperatures 10°C or lower, let it stand for 3 hours or
longer at room temperature before turning ON the power supply.
Use the H8PS within the specified ratings for operating temperature
and humidity.
Do not operate the H8PS in locations subject to sudden or extreme
changes in temperature, or locations where high humidity may
result in condensation.
Do not use the H8PS in locations subject to vibrations or shock.
Extended use in such locations may result in damage due to stress.
Do not use the H8PS in locations subject to excessive dust,
corrosive gas, or direct sunlight.
Install the H8PS well away from any sources of static electricity,
such as pipes transporting molding materials, powders, or liquids.
The H8PS is not waterproof or oil resistant.
Do not use it in locations subject to water or oil.
The life expectancy of internal components may be reduced if the
H8PS is mounted side-by-side.
Do not use organic solvents (such as paint thinner or benzine),
strong alkaline, or strong acids because they will damage the
external finish.
Usage Precautions
Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
Pay careful attention to polarity to avoid wrong connections when
wiring terminals.
Do not connect more than two crimp terminals to the same
terminal.
Use the specified wires for wiring.
Applicable Wires
AWG24 to AWG18 (cross-sectional area of 0.208 to 0.832 mm2)
Solid or twisted wires of copper
Do not connect loads that exceed the rated output current. The
output elements may be destroyed, possibly resulting in short-
circuit or open-circuit faults.
Always connect a diode to protect against counterelectromotive
force when using an inductive load. Counterelectromotive force
may destroy output elements, possibly resulting in short-circuit or
open-circuit faults.
Use the specified cables to connect outputs.
Do not install input lines in the same duct or conduit as power
supply or other high-voltage lines. Doing so may result in
malfunction due to noise. Separate the input lines from high-
voltage lines.
Internal elements may be destroyed if a voltage outside the rated
voltage is applied.
Maintain voltage fluctuations in the power supply within the
specified range.
Use a switch, relay, or other contact so that the rated power supply
voltage will be reached within 0.1 s. If the power supply voltage is
not reached quickly enough, the H8PS may malfunction or outputs
may be unstable.
Do not turn OFF the power supply when changing or deleting
settings. The contents of the EEPROM may be corrupted.
Tighten terminal screws to a torque of 0.80 N·m so that
they do not become loose.
Minor fires or malfunction may occasionally occur.
For 16- and 32-output Models, leave the protective label
attached to the H8PS when wiring. Removing the label
before wiring may occasionally result in fire if foreign
matter enters the Unit.
Remove the label after the completion of wiring to ensure
proper heat dissipation. Leaving the label attached may
occasionally result in fire.
Do not disassemble, modify, or repair the H8PS or touch
any of the internal parts. Otherwise, minor electric shock,
fire, or malfunction may occasionally occur.
Do no allow metal fragments, lead wire scraps, or chips
from processing during installation to fall inside the H8PS.
Otherwise, minor electric shock, fire, or malfunction may
occasionally occur.
Do not touch the terminals when power is being supplied.
For Surface-mounting H8PS, always connect the terminal
cover for after completing wiring. Otherwise, minor injury
due to electric shock may occasionally occur.
!CAUTION
H8PS
19
Precautions for Correct Use
A cam output will remain ON if the set angles for two steps overlap
for the same cam number.
Step 1: 120° ON 170° OFF
Step 2: 150° ON 210° OFF
A step will produce no output if the ON and OFF angle for the step
are the same.
The RUN output does not turn ON during programming.
Note: The RUN output turns ON with the timing shown in the diagram,
but it remains OFF when an error occurs. Thus, you can use the
output as a timing signal during operation, including trial
operation.
Input signals may be accepted, not accepted, or unstable for the
following times when the power supply is turned ON or OFF. Set the
system to allow leeway in the timing of input signals. Approx. 1
second is required from the time the power supply is turned ON
until outputs are made. Refer to the Operation Manual (Cat. No.
Z199) for information on other timing.
When using 16-/32-output Modules, the operation timing of the
outputs will be as shown below in relation to the ON/OFF timing of
the start input. Refer to Bank Functions (F7/F8/F9) on page 29
when switching banks.
Do not subject H8PS Connectors (outputs, Encoder) to more than
30 N of force.
Confirm the waveform of the power supply circuit and install a
surge absorber. Surge or noise applied to the power supply may
destroy internal elements or cause malfunctions.
Switch the power supply circuit with a device rated at 3.5 A or
higher.
Inrush current of approximately 3.5 A will flow for a short period of
time when the power supply is turned ON. The H8PS may not start
if the capacity of the power supply is not sufficient. Be sure to use a
power supply with sufficient capacity.
EEPROM is used as memory when the power is interrupted. The
write life of the EEPROM is 100000 writes. The EEPROM is written
when settings are changed or deleted or when the resolution is
changed.
Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents
may occur if the settings are not appropriate.
Connect all negative () terminals, COM terminals, and Vs
terminals.
When using the Y92C-30 Parallel Input Adapter for parallel
operation, do not connect more than two H8PS Cam Positioners to
the same Encoder.
ON
OFF 120°150°170°210°
ON
OFF
RUN/TEST
PRGM
RUN output
Mode Switch
Unstable
Unstable
Not accepted
Accepted
Input status
Power
supply
0 to 1.3 s
ON
OFF
5 ms 0 to 1 s
225 ms max. 225 ms max.
Output OFF
Output OFF
Output possible
ON
OFF
Cam outputs
RUN output
Start input
Refer to the following manual for precautions in using the Cam Positioner and other information required for operation:
H8PS Cam Positioner Operation Manual (Cat. No. Z199)
H8PS
20
Operating Procedures
Flow of Operation
Settings for Basic Functions
Changing the Mode Programming Mode
Used to write cam programs, set the advance angle compensation
function, etc.
All outputs will remain OFF.
Test Mode
Used to write cam programs, set the advance angle compensation
function, and perform other operations while actually turning ON
outputs to confirm operation timing. This mode is also used to adjust
settings during operation.
Run Mode
Used for normal operation. Settings, such as writing cam programs
and setting the advance angle compensation function, cannot be
performed.
The Encoder resolution and rotation direction is set on a DIP switch.
For details on the setting methods, refer to page 21.
The Encoder is mounted to the machine and the origin for operation is determined.
For details on the setting methods, refer to page 21.
Parameters can be set in Function Setting Mode to perform more advanced operations.
For details, refer to page 26 Advanced Functions.
The machine is operated and outputs are actually made to check the timing of operation.
If the timing of operation is not correct, it can be changed.
For details, refer to page 23.
The ON/OFF angles that have been set can be checked.
For details, refer to page 24.
Deletes settings. There are two methods that can be used to delete settings.
Clearing all programs (deletes all programming)
Clearing individual steps, cams, and banks
For details, refer to page 25.
There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming).
Using the ANGLE Keys (Manual Mode)
Actually turning the Encoder (Teaching Mode)
Setting from personal computer using Support Software (order separately)
For details on the setting methods, refer to pages 22 to 23.
Advanced
function
Advance angle compensation (ADV) function can be set if required.
For details on the setting methods, refer to page 27.
Operation is started.
For details, refer to page 24.
Advanced
function
Setting the Origin
Setting ON/OFF Angles
Setting the ADV Function
Checking ON/OFF Angle Settings
Initial Settings
Programming Cams (Programming Mode)
Checking Timing (Test Mode)
Operation (Run Mode)
Clearing Settings
Setting Functions
Setting Resolution and
Rotation Direction
PRG
TST
RUN
PRG
TST
RUN
PRG
TST
RUN
All Protection Switching the Angle
and Speed Display
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
Main Display: Angle
Sub-display: Speed
↓ ↑
Main Display: Speed
Sub-display: Angle
Refer to page 24.
Test Mode
Run Mode
PRG
RUN
TST
Changed with the mode switch.
Changed with the mode switch.
Key
1 s min.
ADVKey
5 s min.
ON/OFF
Programming Mode
H8PS
21
Setting Resolution and Rotation
Direction
One of three resolutions can be selected for the Encoder connected
to the H8PS: 256, 360, or 720. The resolution and display angle are
set here.
Setting the Origin
The origin of the Cam Positioner is set to match the origin of the
machine (Encoder). The same origin is used for all banks.
(The bank function is supported only for 16-/32-output models.)
Turn OFF the power supply.
Set the display angle and the
Encoder resolution.
Check the rotation direction of the machine (Encoder).
Connect the machine (Encoder) and turn ON
the power supply.
End of preparations.
Open the front cover at the lower part of the H8PS and
set pins 3 and 4 on the DIP switch.
Note: Changes to DIP switch settings are enabled when the power is turned ON.
Note: Default setting.
Turn ON the power supply.
Turn the Encoder in the actual direction of operation and
confirm that the rotation display monitor turns clockwise.
If the monitor turns counterclockwise, turn OFF the power supply
and change pin 1 on the DIP switch to CCW.
Rotation Display Monitor
(See note.)
Note 1: Default settings are shown in reverse type.
Note 2: When using an Encoder with a resolution of 256, displaying 360°
directly is not possible. The H8PS thus provides a convenient
setting that enables converting the display and settings to 360°
when using an Encoder with a resolution of 256. When using a
360° display, however, some angles will not be displayed.
(See note 2.)
OFF
ON
4321
Not used. CCW
OFF
OFF
ON
ON
OFF
ON
OFF
720 360
360360
360256
256256
ON
43
CW
OFF
ON
4321
Not used. CCW
OFF
OFF
ON
ON
OFF
ON
OFF
720 360
360360
360256
256256
ON
43
Display
angle
Resolution
CW
Display
angle
Resolution
Example: Setting the Present Angular Position of 150° to 0°
Change the mode.
Set the programming
mode switch.
Set the machine to its origin.
Specify the origin.
End
Turn the machine (Encoder) to the position of the desired
origin (150° in this example).
Press the ORIGIN Key. (See note.)
In approx. 1 s, the present angular position display will
change to 0° and the previous display will return.
Set the mode switch to PRGM.
Set the programming mode switch to TCH.
Mode Programming mode
PRG
TST
RUN
TCH
MAN
CAM STEP
PRG
CAM STEP
PRG
Note: With 16-/32-output models, the origin input
from the terminal block can be turned ON to
specify the origin.
H8PS
22
Setting ON/OFF Angles in Manual Mode
ON/OFF angles can be set manually using the ANGLE Keys
on the front of the Cam Positioner.
Setting ON/OFF Angles in Teaching
Mode
ON/OFF angles can be set based on actual machine (Encoder)
operation.
Example: Setting Step 1 of Cam No. 2 to Turn ON at 28° and
Turn OFF at 51°
Set the bank No.
Set the cam and step No.
Set the ON angle.
Set the OFF angle.
End
Change the mode.
Set the programming
mode switch.
Set the mode switch to PRGM.
Set the programming mode switch to MAN.
Banks can be specified only for
16-/32-output models.
Note: Pressing the or Key continually will automatically increment or
decrement the value. Pressing the other key during automatic increment
or decrement will increase the speed.
Press the BANK Key to specify the bank number and
then press the WRITE Key.
Press the CAM Keys to specify cam No. 2.
Press the STEP Keys to specify step No. 1.
Press the Key to flash the .
Press the ANGLE Keys to set an angle of 28
and then press the WRITE Key.
Press the Key to flash the .
Press the ANGLE Keys to set an angle of 51 and then
press the WRITE Key.
"OFF"
"ON"
ON OFF
ON OFF
Mode Programming mode
PRGM
TEST
RUN
TCH
MAN
CAM STEP
PRG
CAM STEP
PRG
CAM STEP
PRG
Example: Setting the ON/OFF Angles by Teaching Step 2 of
Cam No. 3
Set the bank No.
Set the cam and step No.
Set the ON angle.
Set the OFF angle.
End
Change the mode.
Set the programming
mode switch.
Press the Key to flash the .
Turn the machine (Encoder) to the desired ON angle.
(195° in this example)
Press the
WRITE
Key.
Press the Key to flash the .
Turn the machine (Encoder) to the desired OFF angle.
(278° in this example)
Press the
WRITE
Key.
Set the mode switch to PRGM.
Set the programming mode switch to TCH.
Banks can be specified only for
16-/32-output models.
Press the CAM Keys to specify cam No. 3.
Press the STEP Keys to specify step No. 2.
Press the
BANK
Key to specify the bank number and
then press the
WRITE
Key.
Mode Programming mode
PRGM
TEST
RUN
TCH
MAN
CAM STEP
TST
CAM STEP
TST
CAM STEP
TST
"
ON
"
ON OFF
"
OFF
"
ON OFF
H8PS
23
Setting ON/OFF Angles Using Support
Software
With 16-/32-output models, programs can be uploaded or
downloaded easily with the optional Support Software (H8PS-SOFT-
V1) by connecting a personal computer to the Cam Positioner using
the USB cable (Recommended USB Cables: ELECOM CO.Ltd.
U2C-MF20BK).
Support Software Functions
Writing cam programs
Setting functions
Editing, saving, and printing programs
Displaying and printing cam program operation charts
Simple simulations of programs
Applicable OS: Windows 98, 2000, ME, or XP
Refer to the user’s manual for the Support Software for details.
Checking Timing (Test Mode)
Testing Operation
Operation can be tested to check operation timing.
Note: 1. Outputs will turn ON and OFF in Test Mode. Confirm system
safety before switching to Test Mode.
2. With 16-/32-output model, be sure to turn ON the start input.
Outputs are not turned ON unless the start input is turned
ON.
Mode
PRGM
TEST
RUN
CAM STEP
12 7
TST
Set the mode switch to TEST.
Operate the Encoder and check the timing of operation.
Present angular position
ON/OFF angle setting
If the timing is not correct, change the ON/OFF angle settings.
The settings can be changed in Test Mode.
H8PS
24
Operation (Run Mode)
Starting Operation
Switching the Angle and Speed Displays
All Protection Function
The all protection function locks the H8PS in Run Mode and prohibits
any changes to settings. It can be used to prevent incorrect or
unauthorized operation. If the Key is pressed for at least 5 s in
Run Mode, the All Protection indicator will light on the display
and all keys and switches will be disabled. If the mode switch is
changed to Programming or Test Mode while protection is enabled,
the All Protection indicator will flash to indicate that settings
cannot be changed. If a setting on the DIP switch is changed while
protection is enabled, the All Protection indicator will flash when
the power supply is turned ON to indicate that settings cannot be
changed.
Checking ON/OFF Angle Settings
During Run Mode, the CAM Keys and STEP Keys
can be used to check the ON/OFF angle settings for any step. Also,
the Key can be pressed to check the ON/OFF angle
settings in order for all steps starting from cam 1. If there is no key
operation for 10 s or longer during the checking operation, the
previous display will be resumed.
Note: For 16/32-output models, be sure that the start input is ON
and that the start input indicator is lit. Outputs (including
the cam, pulse, and run outputs) will not function if the
start input is OFF. The 8-output models do not have a
start input.
Mode
PRGM
TEST
RUN
RUN
12 7
CAM STEP
Set the mode switch to RUN to start operation.
Present angular position
Speed (r/min)
Start input
indication
(See note.)
Press the Key for at least 1 s in Run Mode to reverse the
display positions of the present angular position and speed (r/min)
between main display and sub-display.
RUN
RUN
12 7
12 7
Present angular position on main display
Speed (r/min) on sub-display
Speed (r/min) on main display
Present angular position on sub-display
Press the Key for 1 s min.
ON OFF
ON OFF
ADV
Press the ADV Key for 5 s min.
All Protection Function Disabled (Normal Operation)
All Protection Function Enabled
RUN
CAM STEP
12 456
RUN
CAM STEP
12 456
All protection indication
CHECK
H8PS
25
Clearing Settings
Clearing All Programs
The all clear function can be used to delete all cam programs, the
settings for advance angle compensation function, and all other
settings. All settings in the Function Setting Mode will be returned to
their default settings.
Clearing Individual Steps, Cams, and Banks
ON/OFF angle settings can be deleted by step, by cam, or by bank. If
settings are deleted by cam, the settings for the advance angle
compensation (ADV) function will not be deleted. If settings are
deleted by bank, the settings for the ADV function will also be
deleted. Settings in the Function Setting Mode will not be deleted.
Initial Display
Set the mode switch to PRGM or TEST.
Press the WRITE Key.
CLEAR Key
Press the CLEAR Key for 3 s min.
Confirm that clr flashes on the display.
After the completion of all clear
processing, the screen displays end for
approximately one second and then
resume the previously displayed screen.
If the CLEAR Key is pressed again before
pressing the WRITE Key, the settings will
not be deleted and the previous display
will be resumed.
Mode
PRGM
TEST
RUN
CAM STEP
PRG
CAM STEP
PRG
PRG
Initial Display
Screens for Individually Clearing Items
Set the mode switch to PRGM or TEST.
Press the WRITE Key.
Press the CLEAR Key.
Deleting Settings by Step
Press the STEP Keys
to specify the step to be
deleted.
Deleting Settings by Cams
Press the CAM Keys to
specify the cam to be
deleted.
Deleting Settings by Banks
Press the BANK Key to
specify the bank to be
deleted.
CLEAR Key.
After the completion of all clear
processing, the screen displays end for
approximately one second and then
resume the previously displayed screen.
If the CLEAR Key is pressed again before
pressing the WRITE Key, the settings will
not be deleted and the previous display
will be resumed.
Mode
PRGM
TEST
RUN
CAM STEP
PRG
CAM STEP
PRG
CAM STEP
PRG
CAM STEP
PRG
PRG
H8PS
26
Advanced Functions
Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following
pages. For details, refer to the Operation Manual (Cat. No. Z199).
Mode Transitions
PRGM
TEST
RUN
PRGM
TEST
RUN
PRGM
TEST
RUN
: No. of pulse outputs [60]
: Pulse output start angle [0°]
: Speed alarm upper limit [---]
: Speed alarm lower limit [---]
: Step number limit [---] (See note 1.)
: Cam protection [None]
: Bank enable/disable [Disable]
: Bank switching method [Bank inputs] (See note 2.)
: Bank copy (See note 2.)
Shaded items above are not displayed for 8-output models.
The values in parentheses are the default settings.
Note 1: The default setting is for 10 steps for all cams.
Note 2: Not displayed when F7 is disabled.
: E24 detection enable/disable [Enable]
Setting the
ADV Function
Advance angle
compensation (ADV)
function automatically
advances the ON/OFF
angle of outputs in
proportion to the
machine (Encoder)
speed.
Refer to pages 28 to 30.
Programming Mode
Test Mode
Run Mode
PRG
Function Setting Mode
RUN
TST
Changed with the mode switch.
Changed with the mode switch.
ADV Key 3 s min.
ADV Key
ADV Key 5 s min. ON/OFF Key 1 s min.
All Protection Switching the Angle
and Speed Display
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
Main Display: Angle
Sub-display: Speed
↓ ↑
Main Display: Speed
Sub-display: Angle
Refer to page 24.
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
H8PS
27
Advance Angle Compensation (ADV)
Function
The advance angle compensation function automatically advances
the ON/OFF angle of cam outputs in proportion to machine
(encoder) speed. As the speed of the machine increases, the system
can be affected by the delay in outputs. If the ADV function is used,
the output delay caused by higher speeds is automatically
compensated.
As shown in the following diagram, ADV function is used to linearly
compensate outputs according to the speed based on the ADV value
setting for a specific speed.
Example: ADV Value Set to 2° at 100 r/min
ADV value can be set independently for cams 1 to 7 (7 total). For the
ADV function, the speed and the amount of angle compensation are
set. If “- - -” is displayed for any setting, the ADV function is disabled.
The setting ranges are given in the following table.
Note: Default settings are shown in reverse type.
The maximum response speed will decrease as shown in the
following table when ADV values are set for 4 cams or more.
Note: Even if the ADV value is set to 0°, the cam must be included in
the number of cams with ADV settings.
1. Set the mode switch to PRGM or TEST.
2. Set cam number 4 with the CAM Keys . (See note.)
3. Press the Key to move to the ADV function setting display
and confirm that “ADV” is displayed.
Setting Display
7. Press the Key after finishing setting the ADV function. The
previous display in Programming or Test Mode will be resumed.
Note: If the bank function is being used, set the bank number before
setting the cam number.
Encoder Speed ADV value
Resolution Display angle
256 256 ”, 1 to 1,600 ”, 0 to 255
256 360 ”, 1 to 1,600 ”, 0 to 359
360 --- , 1 to 1,600 ”, 0 to 359
720 --- ”, 1 to 800 ”, 0 to 359.5
Number of cams
with ADV settings
Encoder resolution Max. response
speed
0 to 3 256/360 1,600r/min
720 800r/min
4 to 7 256/360 1,200r/min
720 600r/min
Amount of angle compensation
1000 Speed (r/min)
Note: The maximum amount of angle compensation is 360°.
ADV value
2°
100°
8° advance angle
compensation
Cam program setting
180°
92°172°
At high speed
(400r/min)
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Example: Setting the ADV Value to 2° at 100 r/min for Cam 4
4. Set the speed to 100 with the
ANGLE Keys and then
press the Key.
5. Set the ADV value to 2 with the
ANGLE Keys .
6. Press the Key to write
the settings to memory.
ADV
CAM STEP
TST
WRITE
TST
CAM STEP
TST
CAM STEP
WRITE
ADV
H8PS
28
Pulse Output (f1/f2)
Outputs a preset number of pulses per Encoder rotation. Pulses are
output at a 1:1 ON/OFF ratio and pulse output can be started from a
specified angle.
Number of Output Pulses (f1)
Select the number of pulses per rotation from the following table.
Note: Default settings are shown in reverse type.
The number of pulses is set using the F1 menu in the Function
Setting Mode.
Setting Display
Pulse Output Start Angle (f2)
The setting ranges are given in the following table.
Note: 1. Default settings are shown in reverse type.
2. The output accuracy is 2° maximum, so not all angles can
be set.
The starting angle for pulse outputs is set using the F2 menu in the
Function Setting Mode.
Setting Display
Speed Alarm Outputs (f3/f4)
Specific cam outputs can be used as Encoder speed alarm outputs.
Alarms can be output for upper and lower speed limits.
The speed alarm outputs are assigned to cam outputs as shown in
the following table. The speed alarms are set to “- - -” for the default
settings, i.e., the normal cam outputs are enabled. If a speed alarm is
set to any value but “- - -”, the normal cam output for the
corresponding cam number will be disabled.
The setting ranges for the upper and lower limits speed alarm are
given in the following table.
Note: Default settings are shown in reverse type.
Speed Alarm Upper Limit (f3)
The upper limit set value is set using the F3 menu in the Function
Setting Mode.
Upper Limit Setting Display
Note: If banks are being used, the bank number must be set.
Speed Alarm Lower Limit (f4)
The lower limit set value is set using the F4 menu in the Function
Setting Mode.
Lower Limit Setting Display
Note: If banks are being used, the bank number must be set.
Encoder resolution Settable number of pulses
256 1, 2, 3, 4, 5, 6, 9, 10, 12, 15, 18, 20,
30, 36, 45, , 90
360 1, 2, 3, 4, 5, 6, 9, 10, 12, 15, 18, 20,
30, 36, 45, , 90, 180
720 1, 2, 3, 4, 5, 6, 8, 9, 10, 12, 15, 18, 20, 24,
30, 36, 40, 45, , 72, 90, 120, 180, 360
Example: Setting 90 Pulses per Rotation
Set the number of pulses with the
ANGLE Keys and then press the
Key.
Encoder Start angle
Resolution Display
angle
256 256 to 255°
256 360 to 359° (See note 2.)
360 --- to 359°
720 --- to 359.5°
Example: Setting the Pulse Output Start Angle to 100°
Set the pulse output start angle to 100
with the ANGLE Keys and then
press the Key.
1
Output start angle
Operation for 9 Output Pulses and a Start Angle of 0°
23
90°180°270°0°0°
456789
1
Output start angle
Operation for 9 Output Pulses and a Start Angle of 10°
23
90°180°270°0°0°10°
456789
60
60
60
CAM STEP
PRG
WRITE
0
0
0
0
PRG
CAM STEP
WRITE
Upper Limit
Alarm Output
Lower Limit
Alarm Output
H8PS-8@ (8 outputs) Cam 7 Cam 8
H8PS-16@ (16 outputs) Cam 15 Cam 16
H8PS-32@ (32 outputs) Cam 31 Cam 32
Encoder resolution Speed
256, 360 ” or 0 to 1,600 r/min
720 ” or 0 to 800 r/min
Example: Setting the Upper Limit Set Value to 700 r/min for a 16-
output Model
Set the upper limit set value to 700 with
the ANGLE Keys and then press
the Key. (See note.)
Example: Setting the Lower Limit Set Value to 20 r/min for a 16-
output Model
Set the upper limit set value to 20 with
the ANGLE Keys and then press
the Key.
Speed
Upper Limit Alarm Output
Lower Limit Alarm Output
Upper limit SV
Lower limit SV
- - -
- - -
PRG
CAM STEP
WRITE
CAM STEP
PRG
WRITE
H8PS
29
Step Number Limit (f5)
With the H8PS, up to 10 steps can be set to turn the output ON/OFF
10 times for each cam. The number of steps that can be set,
however, can be restricted to prevent programming from being added
through operating mistakes. Settings can be made for all cams at
once or each cam individually. The default setting for the Step
Number Limit is 10 steps for all cams.
The maximum number of steps to be set is set using the F5 menu in
the Function Setting Mode.
Display for Collective Settings
The cam number can be set to a on the setting display to set all
cams at once. If the number of steps is displayed as “---” when the
cam number is a, the collective settings for all cams are disabled.
The maximum number of steps to be set is set using the F5 menu in
the Function Setting Mode.
Display for Individual Settings
Cam Protection (f6)
Cam programs can be write-protected. Use this setting to protect the
programs for only specific cam numbers. Protected cam numbers will
not be displayed in Programming Mode or Test Mode. Writing or
changing programs will not be possible. Protected cam numbers will
also not be displayed in Run Mode and cannot be checked. The
default settings are for no protection for all cams.
Cam protection is set using the F6 menu in the Function Setting
Mode.
Setting Display
Bank Functions (f7/f8/f9)
The bank function is supported by 16-/32-output models. Banks
enable changing the entire cam program at once by switching bank
numbers (0 to 7).
In Run Mode or Test Mode, the start input must be turned OFF and
ON as shown in the following diagram in order to change banks.
Control the start input when changing banks.
Bank Enable/Disable (f7)
The default setting disables the bank function. To use banks, change
the setting using the F7 menu in the Function Setting Mode.
Setting Display
Bank Switching Method (f8)
The following methods can be used to switch the bank: the bank
inputs on the terminal block or the BANK Key on the front of the Cam
Positioner.
Example: Limiting the Number of Steps to 2 for All Cams
Collectively.
Set the cam number to a with the
CAM Keys and set the
maximum number of steps to 2 with
the Angle Keys . Press the
Key to write the setting to
memory.
Example: Limiting the Number of Steps to 1 for Cam 3.
Set the cam number to 3 with the
CAM Keys and set the
maximum number of steps to 1 with
the Angle Keys . Press the
Key to write the setting to
memory.
Example: Protecting Cam 3 with an 8-output Model
Set the cam number to be
protected (and not displayed) to 3
with the CAM Keys and
then press the Key. The
output display will go out.
PRG
CAM STEP
WRITE
PRG
CAM STEP
WRITE
CAM STEP
PRG
12 45678
Not lit (protected)
WRITE
Enable or disable the bank function
with the ANGLE Keys .
Cam Program (Bank No. 7)
Cam Program (Bank No. 2)
Cam Program (Bank No. 1)
Cam Program (Bank No. 0)
Control output
(cam number)
Step 0 Step 1 Step 9
ON angle
OFF angle
145°90°135°225°270°315°
20°90°135°180°--- ---
32 90°225°270°285°315°345°
OFF angle OFF angle
ON angle ON angle
Start
input
Bank 0
Bank 0 Bank 1 Bank 2
Bank 1
Bank 2
T2
T4
T1 T2 T3
Operation
ON
OFF
ON
OFF
RUN
output
Unstable region (outputs OFF) T1: 225 ms max.
T2: 400 ms max.
T3: 20 ms min.
T4: 20 ms min.
Bank
specification
CAM STEP
PRG
yes no
(Enabled) (Disabled)
H8PS
30
Bank Switching Method (f8)
The following methods can be used to switch the bank: the bank
inputs on the terminal block or the BANK Key on the front of the Cam
Positioner. The method is set using the F8 menu in the Function
Setting Mode.
Note: 1. Default settings are shown in reverse type.
2. This setting can be made only when the Bank Function (F7)
has been enabled.
Setting Display
The bank inputs on the terminal block are used as shown in the
following table.
ON: Shorted to COM terminal.
OFF: Open
Bank Copy (f9)
Programs can be copied between banks. This function is convenient
to copy a program to a different bank when only some of the ON/OFF
angle settings need to be changed.
Note: This operation can be used only when the Bank Function (F7)
has been enabled.
Banks are copied using the F9 menu in the Function Setting Mode.
Setting Display
1. Set the number of the bank to be copied.
2. Set the number of the bank to receive the copy.
3. Execute the copy.
4. Copying completed.
E24 Detection (f10)
Displaying E24 errors (Encoder disconnected) can be disabled. The
setting does not normally need to be changed. When the Y92C-30
Parallel Input Adapter (order separately) is used to connect more
than one H8PS to the same Encoder, an E24 error can appear even
if the Encoder connection is normal. If this happens, use the E24
Detection function (F10) in the Function Setting Mode to disable E24
detection displays.
Note: Default settings are shown in reverse type.
Setting Display
Setting Display Description
Bank input
(IN)
Banks can be changed only with the bank
inputs. Even if a different bank number is
displayed in Programming Mode, the bank
specified with the bank inputs will be used
after switching to Run Mode or Test Mode.
Bank Key
(KEY)
key Banks can be changed only with the
BANK Key. Bank inputs are disabled.
Use the ANGLE Keys to set
the bank switching method.
Bank No. Bank input terminals
124
0OFF OFF OFF
1ON OFF OFF
2OFF ON OFF
3ON ON OFF
4OFF OFF ON
6ON OFF ON
6OFF ON ON
7ON ON ON
in
CAM STEP
PRG
in key
(IN) (KEY)
Example: Copying the Program in Bank 2 to Bank 3
Set bank number 2 (the copy
source) with the Key and
then press the Key.
Set bank number 3 (the copy
destination) with the Key and
then press the Key.
Confirm that cpy is displayed and
then press the Key again.
After completion of copying end is
displayed for approx. 1 s and the
previous display will be resumed.
PRG
CAM STEP
BANK
WRITE
PRG
CAM STEP
BANK
WRITE
PRG
CAM STEP
WRITE
PRG
CAM STEP
Setting Display Description
Enabled An E24 error will be displayed if the
Encoder is not connected correctly in
Run Mode or Test Mode.
Disabled no An E24 error will not be displayed
even if an Encoder is not connected.
yes
Enable or disable E24 detection
with the ANGLE Keys .
PRG
CAM STEP
yes no
(Enabled) (Disabled)
H8PS
31
Self Diagnostic Function
The following displays will appear on the main display if an error occurs. If an error occurs, all outputs (including cam, pulse, and run outputs) will
be turned OFF.
Angle Data Table
To assist with programming when using an Encoder with a resolution of 256/rotation, displays and settings may be done by conversion to 360
degrees by setting a pin on the DIP switch inside the front cover. The following table shows the conversions.
Display Meaning Recovery method
e00 Origin designation data error Press the CLEAR Key for at least 3 s. All settings, including the origin designation data, will be
initialized.
e11 Memory error: RAM error Cycle the power supply.
e12 Memory error: Checksum error Press the CLEAR Key for at least 3 s. All settings, including the origin designation data, will be
initialized.
e13 CPU error Cycle the power supply.
e21 Response speed exceeded The Encoder is rotating faster than the allowable range. Reduce the speed to within the allowable
range. Then cycle the power supply or switch to Programming Mode and then to Run Mode.
e22 Encoder data error There are surges or noise around the product or in the wiring. Check the wiring and protect the
product from surges and noise. Then cycle the power supply.
e23 Encoder resolution inconsistent Set the Encoder resolution according to the specifications of the Encoder. Then cycle the power
supply.
e24 Encoder disconnected Connect the Encoder connector properly. Then, cycle the power supply or switch to Programming
Mode and then to Run Mode.
012345678910 11 12 13 14 15
0°1°3°4°6°7°8°10°11°13°14°15°17°18°20°21°
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
23°24°25°27°28°30°31°32°34°35°37°38°39°41°42°44°
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
45°46°48°49°51°52°53°55°56°58°59°60°62°63°65°66°
48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
68°69°70°72°73°75°76°77°79°80°82°83°84°86°87°89°
64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
90°91°93°94°96°97°98°100°101°103°104°105°107°108°110°111°
80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
113°114°115°117°118°120°121°122°124°125°127°128°129°131°132°134°
96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
135°136°138°139°141°142°143°145°146°148°149°150°152°153°155°156°
112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
158°159°160°162°163°165°166°167°169°170°172°173°174°176°177°179°
128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143
180°181°183°184°186°187°188°190°191°193°194°195°197°198°200°201°
144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
203°204°205°207°208°210°211°212°214°215°217°218°219°221°222°224°
160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175
225°226°228°229°231°232°233°235°236°238°239°240°242°243°245°246°
176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191
248°249°250°252°253°255°256°257°259°260°262°263°264°266°267°269°
192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207
270°271°273°274°276°277°278°280°281°283°284°285°287°288°290°291°
208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223
293°294°295°297°298°300°301°302°304°305°307°308°309°311°312°314°
224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239
315°316°318°319°321°322°323°325°326°328°329°330°332°333°335°336°
240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
338°339°340°342°343°345°346°347°349°350°352°353°354°356°357°359°
256 display (Encoder output data)
360° display (360° converted data)
01
0°1°
How to Use the Table
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2019.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2019 All Right Reserved.