54
G3VM-41HR
MOS FET Relays
Low 30-m ON Resistance.
Higher power, 2.5-A switching with a
40-V load voltage, SOP package.
Continuous load current of 2.5 A (connection C = 5 A).
Dielectric strength of 1,500 Vrms between I/O.
! Refer to “Common Precautions”.
Application Examples
Broadband systems
Measurement devices
Data loggers
Industrial equipment
Note: The actual product is marked differently from the image
shown here.
List of Models
Note: The AC peak and DC value is given for the load voltage.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/Internal Connections (Top View)
Actual Mounting Pad Dimensions (Recommended Value, Top View)
RoHS compliant
Contact form Terminals Load voltage (peak value)
(See note.)
Model Number per stick Number per tape
SPST-NO Surface-mounting
terminals
40 V G3VM-41HR 75 ---
G3VM-41HR(TR) --- 2,500
4.4
±
0.25
6.3
±
0.25
0.4
±
0.1
2.54
±
0.25
2.1 max.
0.1
±
0.1
7.0
±
0.4
0.6
±
0.3
0.15
G3VM-41HR
Note: The actual product is marked differently
from the image shown here. Weight: 0.13 g
654
13
2
G3VM-41HR
6 to 6.3
1.2
0.8
2.542.54
G3VM-41HR
55
G3VM-41HRG3VM-41HR
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Engineering Data
Load Current vs. Ambient Temperature
G3VM-41HR
Safety Precautions
Refer to “Common Precautions” for all G3VM models.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF30 mA
LED forward current reduction rate IF/°C0.3 mA/°CTa 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 40 V
Continuous load
current
Connection A IO2.5 A Connection A: AC peak/DC
Connection B and C: DC
Connection B 2.5
Connection C 5
ON current reduction
rate
Connection A IIO/°C33.3 mA/°CTa 50°C
Connection B 33.3
Connection C 66.7
Pulse on current Iop 7.5 A t = 100 ms
Connection temperature Tj125 °C
Dielectric strength between input and
output (See note 1.)
VI-O 1,500 Vrms AC for 1 min
Operating temperature Ta40 to +85 °C With no icing or condensation
Storage temperature Tstg 55 to +125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C 10 s
Load
or AC
DC
1
2
3
6
5
4
1
2
3
6
5
4
Load
DC
DC
Load
Connection Diagram
Connection
A
Connection
B
Connection
C
1
2
3
6
5
4
Note: 1. The dielectric strength between the in-
put and output was checked by apply-
ing voltage between all pins as a
group on the LED side and all pins as
a group on the light-receiving side.
Item Symbol Mini-
mum
Typical Maxi-
mum
Unit Measurement
conditions
Input LED forward voltage VF1.18 1.33 1.48 V IF = 10 mA
Reverse current IR--- --- 10 µAV
R = 5 V
Capacity between terminals CT--- 70 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- 0.4 3 mA IO = 100 mA
Output Maximum resistance
with output ON
Connection A RON --- 0.03 0.06 IF = 5 mA, IO = 2 A, t < 1S
Connection B --- 0.015 0.03 IF = 5 mA, IO = 2 A, t < 1S
Connection C --- 0.008 --- IF = 5 mA, IO = 4 A, t < 1S
Current leakage when the relay is
open
ILEAK --- --- 10 nA VOFF = 40 V
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MVI-O = 500 VDC,
RoH 60%
Turn-ON time tON --- 1.0 5.0 ms IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF --- 0.15 1.0 ms
VOUT
IF
tON tOFF
10% 90%
IF1
2
6
4
RLVDD
VOUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 40 V
Operating LED forward current IF57.520mA
Continuous load current (AC peak/DC) IO--- --- 2 A
Operating temperature Ta20 --- 65 °C
6
5
4
3
2
1
020 0 20 40 60 80 100
Ambient temperature (°C)
Load current (A)
Connection C
Connection A, Connection B