1
1
2
2
3
3
4
4
A A
B B
C C
D D
APPLICATION
USB-2000-CAXXXX
DIMENSIONS ARE IN INCHES
DRAWN:
CHECK
ENGINEER
CAGE CODE
19476
SCALE
.X+/- 0.5
.XX+/-0.05
.XXX+/-0.005
ANGLES +/- 5 DEG
[MM]
DRAWING NUMBER REVISIONSIZE
N/C
SIGNATURE
TITLE
24960 AVENUE TIBBITTS, VALENCIA, CA 91355 www.cicoil.com 661-295-1295
THESE DRAWI NGS AND SPECIFICATIONS ARE THE PROPERTY OF
CICOIL LLC AND ARE ISSUED IN STRICT CONFIDENCE AND SHALL NOT
BE REPRODUCED OR COPIED OR USED AS THE BASIS FOR THE
MANUFACTURE OR SALE 0F EQUPMENT WITHOUT PERMISSION.
DASH
NO
QTY
REQD
NEXT
ASSEMBLY
FINAL
ASSEMBLY
VIEW PROJECTION
USB CABLE ASSEMBLY
STANDARD TOLERANCES
UNLESS OTHERWISE NOTED
rruiz
JOHN PALAHNUK
JOHN PALAHNUK
12/4/2012
DO NOT SCALE DRAWING
SHEET 1 OF 1
MATERIAL:
8/21/2013
8/21/2013
FILE: USB-2000-CAXXXX (C).idw
DATE
}
"B" BILL OF MATERIALS, H-P; USB-2000-
DESCRIPTIONPART NUMBERQTYITEM
CICOIL BULK
CABLE
579R101A/R
1
ASSMANN
USB TYPE A
CONNECTOR
A-USBPA-3-R*
12
ASSMANN
USB TYPE B
CONNECTOR
A-USBPB-2-R*
1
3
BLACK HEAT
SHRINK
(-55°C TO
+135°C)
PRODUCTION
PREFERENCE
14
"A" BILL OF MATERIALS, H-H; USB-2000
DESCRIPTION
PART NUMBER
QTY
ITEM
CICOIL BULK
CABLE
579R101
A/R
1
ASSMANN
USB TYPE A
CONNECTOR
A-USBPA-3-R*22
BLACK HEAT
SHRINK
(-55°C TO
+135°C)
PRODUCTION
PREFERENCE
A/R3
REVISION HISTORY
ZONE REV DESCRIPTION DATE BY
ALL N/C INITIAL RELEASE 12/04/12 RR
CROSS SECTION VIEW
OF THE CABLE
P/N: 579R101
WIDTH .31"
HEIGHT .15"
A
B
O
O
ASSY. P/N: USB-2000-CAX003
USB-2000-CAX006
USB-2000-CAX012
NOTES, UNLESS OTHERWISE SPECIFIED:
1 INSTALL CONNECTORS AS REQUIRED
2 STRIP AND TIN PER IEC-J-STD-001
3 USE STRAIN RELIEF AS REQUIRED
4 INSTALL BLACK HEAT SHRINK AS REQUIRED
5 CONDUCTORS: ULTRA FLEXIBLE,
FINELY STRANDED, TINNED COPPER
6 SHIELDING: ULTRA FLEXIBLE, BRAIDED
SHIELDS,WITH 90% NOMINAL COVERAGE
7 MINIMUM BEND RADIUS: 6X CABLE HEIGHT FOR
INTERMEDIATE FLEX;
10X CABLE HEIGHT FOR CONTINUOUS FLEX
8 FLEX LIFE: 10,000,000 CYCLES NOMINAL
9 OUTER JACKET DUROMETER RATING:
65 (SHORE A)
10
TEMPERATURE RATING FOR CABLE:
-65°C TO +165°C
TEMPERATURE RATING FOR
FINISHED ASSEMBLIES:
-20°C TO +85°C
11 OUTER JACKET DIELECTRIC STRENGTH:
450 VOLTS/MILS (17.7 kv/mm)
12 * OR EQUIVALENT
12
3
22
1
LENGTH IN FEET"H"= HOST TO HOST
OR
"P"= HOST TO PERIPHERAL