Approval sheet
Page 7 of 8 ASC_WFxxU_V16 Mar.2012
TEST AND REQUIREMENTS(JIS C 5201-1 : 1998)
REQUIREMENT
TEST PROCEDURE Resistor
DC resistance
Clause 4.5 DC resistance values measured at the test voltages specified below :
<10Ω@0.1V, <100Ω@0.3V, <1KΩ@1.0V,
<10KΩ@3V, <100KΩ@10V,<1MΩ@25V, <10MΩ@30V
Within the specified tolerance
Temperature Coefficient
of Resistance(T.C.R)
Clause 4.8
Natural resistance change per change in degree centigrade.
( )
6
121
12 10×
−
ttR RR
(ppm/°C)
R
1
: Resistance at reference temperature
R
2
: Resistance at test temperature
t
1
: 20°C+5°C-1°C
t2 : 125°C+5°C-1°C
Refer to
“QUICK REFERENCE DATA”
Short time overload
(S.T.O.L)
Clause 4.13
Permanent resistance change after a 5second application of a voltage
2.5 times RCWV or the maximum overload voltage specified in the
above list, whichever is less.
∆R/R max. ±(0.2%+0.05Ω)
Resistance to soldering
heat(R.S.H)
Clause 4.18
Un-mounted chips completely immersed for 10±1second in a SAC
solder bath at 260℃±5ºC no visible damage
∆ R/R max. ±(0.1%+0.05Ω)
Solderability
Clause 4.17
Un-mounted chips completely immersed for 2±0.5 second in a SAC
solder bath at 235℃±5℃ good tinning (>95% covered)
no visible damage
Temperature cycling
Clause 4.19
30 minutes at -55°C±3°C, 2~3 minutes at 20°C+5°C-1°C, 30
minutes at +155°C±3°C, 2~3 minutes at 20°C+5°C-1°C, total 5
continuous cycles
no visible damage
∆R/R max. ±(0.25%+0.05Ω)
Load life (endurance)
Clause 4.25 1000 +48/-0 hours, loaded with RCWV or Vmax in chamber controller
70±2ºC, 1.5 hours on and 0.5 hours off ∆R/R max. ±(0.5%+0.05Ω)
Load life in Humidity
Clause 4.24 1000 +48/-0 hours, loaded with RCWV or Vmax in humidity chamber
controller at 40°C±2°C and 90~95% relative humidity, 1.5hours on
and 0.5 hours off
∆R/R max. ±(0.5%+0.05Ω)
Bending strength
Clause 4.33 Resistors mounted on a 90mm glass epoxy resin PCB(FR4);
bending : 3 mm, once for 10 seconds. ∆R/R max. ±(0.1%+0.05Ω)
Adhesion
Clause 4.32 Pressurizing force: 5N, Test time: 10±1sec. No remarkable damage or
removal of the terminations.
Insulation Resistance
Clause 4.6 Apply the maximum overload voltage (DC) for 1minute R≧10GΩ
Dielectric Withstand
Voltage
Clause 4.7
Apply the maximum overload voltage (AC) for 1 minute No breakdown or flashover