Automotive brushless DC fans
Climate control for commercial vehicles
Version 2012-09
The engineer’s choice
2
Automotive brushless DC fans
Advantages and characteristics in a glance
Over 40,000 operating hours
Continuous speed control
High efficiency
Low noise emission due to aerodynamically optimised impellers
Increased reliability due to high integration density of the electronics
Can be retrofitted to existing systems
Meet the highest EMC requirements
Control characteristic can be parameterised
Optimised voltage independence
Extended temperature range
Durable ball bearings
Our automotive brushless DC (BL-DC) axial fans and BL-DC dual centrifugal blowers set
the trend in commercial vehicle climate control. They not only fulfil today’s increased expec-
tations for comfort, for example in buses, they also work without wear – because they are
brushless – for over 40,000 hours. No extra maintenance, no additional service required.
That is the reliability you expect from ebm-papst.
3
EC dual centrifugal blowers with brushless DC motor 9
“Premium”
EC axial fans with brushless DC motor 25
EC centrifugal fans - RadiCal, backward curved 43
Ideas for technological change in commercial vehicles 6
Accessories 50
Temperature control module, temperature sensor
Connection leads
Electrical connections 53
Technical parameters & scope 58
Table of contents
EC dual centrifugal blowers with brushless DC motor 19
“Basic”
GreenTech: The Green Company 4
ebm-papst representatives & subsidiaries 62
Sustainability is at the Centre of Our
Thoughts and Actions. Out of Conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
5
GreenTech is acknowledged and certified.
Every step in our chain of production meets the stringent standards of
environmental specialists and the public. The 2008 Environmental Prize
of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
Award 2009 of the dena – to give just a few examples – testify to this.
The environmental advantage gained in the performance of the products
developed from our GreenTech philosophy can also be measured in the
fulfilment of the most stringent energy and environmental standards.
In many instances, our products are already well below the thresholds
energy legislation will impose a few years from now – several times over.
Our customers profit from this every day.
The heart of GreenTech is future-oriented EC technology from ebm-
papst. The EC technology at the core of our most efficient motors and
fans allows efficiency of up to 90%, saves energy at a very high level,
significantly extends service life and makes our products maintenance-
free. These values pay off not only for the environment, but every cent al-
so pays off for the user! All ebm-papst products – even those for which
GreenTech EC technology does not (yet) make sense from an application
viewpoint – feature the greatest possible connection of economy and
ecology.
GreenTech is pro-active development.
Even in the design phase, the materials and processes we use are optimi-
sed for the greatest possible eco-friendliness, energy balance and –
wherever possible – recyclability. We continually improve the material
and performance of our products, as well as the flow and noise charac-
teristics. At the same time, we significantly reduce energy consumption.
Close cooperation with universities and scientific institutes and the pro-
fessorship we endow in the area of power engineering and regenerative
energies allows us to profit from the latest research findings in these
fields – and at the same time ensure highly qualified young academics.
GreenTech is ecofriendly production.
GreenTech also stands for maximum energy efficiency in our production
processes. There, the intelligent use of industrial waste heat and ground-
water cooling, photovoltaics and, of course, our own cooling and venti -
lation technology are of the utmost importance. Our most modern plant,
for instance, consumes 91% less energy than currently specified and
required. In this way, our products contribute to protecting the environ-
ment, from their origin to their recyclable packaging.
6
Ideas for technological change in commercial vehicles
A comfortable environment in commercial vehicles is by no means just a
matter of amenities. Both passenger transportation in buses and coaches
along with trucking that is as free of stress and fatigue as possible place
high demands on vehicle technology, particularly climate control, ventila-
tion and air-conditioning.
For many years, renowned bus manufacturers have installed air-condi-
tioning systems with brushless and wear-free centrifugal blowers and
axial fans from ebm-papst. These products have also come to be used
widely for climate control and ventilation of driver’s cabs in trucks,
tractors and construction equipment as well as in transport refrigeration
systems.
A wide variety of climate control system manufacturers rely the
experience and excellent skills of ebm-papst in our core competencies of
motor development, aerodynamics and electronics.
EC dual centrifugal blowers:
for maximum performance
with the smallest installa-
tion space; easy to control
and extremely quiet.
7
Meeting high demands with new technology
In modern commercial vehicles, EC technology has now become the stan-
dard. Our new second-generation EC axial fans and EC dual centrifugal
blowers set the trend in commercial vehicle climate control around the
world. Our EC fans demonstrate their clear superiority even in hot climates
and tropical regions, where they have also already proven their excellent
performance.
But customers rely on ebm-papst products not only in the area of climate
control. Increasingly, EC fans are also finding application in the cooling of
heat exchangers in the engine compartment of vehicles.
In comparison:
In commutator motors from other manufac-
turers, the commutator performs the task of
distributing current to the coils. The commu-
tator consists of copper segments embedded
in an insulating compound. Mechanical
springs press the integrated carbon brushes
onto the commutator. The friction between
these two mechanical components is the
weak point of conventional DC motors. After a
running time of approximately 5,000 hours,
the carbon brushes and the commutator are
worn out. As a result, the entire blower needs
to be replaced. Furthermore, open loop speed
control is possible only with external electron-
ics.
This is not true of brushless DC motors from ebm-papst. An electronic
control integrated directly into these motors assumes the task of current
distribution. No brushes means no parts to wear out. This increases the
operating time of these motors to more than 40,000 hours. As a result,
the user not only saves on spare parts and repair costs, but also avoids
unproductive downtimes and potential damage to reputation.
EC motors are energy-efficient, since the integrated electronics use con-
tinuous closed loop speed control to draw from the vehicle electrical sys-
tem only the energy actually required. In commercial vehicle applications,
it is also important that fans withstand environmental influences wich are
constantly fluctuating. Standard products would provide less than satis-
factory results in these situations. Therefore, ebm-papst automotive prod-
ucts also feature reliable protection against load dump, reverse polarity,
shock and vibration as well as damage from moisture and dirt in a wide
temperature range. This requires exceptional effort when selecting materi-
als and testing the products. We use extreme tests, which we have
designed together with market-leading OEMs, based on real-world condi-
tions (such as salt spray fog, vibration and temperature change tests) to
ensure the performance of the fans.
In addition to the significantly longer service life, our intelligent EC fans
guarantee extended open and closed loop control options. The function of
the fans can be determined at any time via a diagnostic output. Moreover,
they have an excellent electromagnetic compatibility and operate
extremely quietly.
But ebm-papst offers even more:
If you are ever unable to find a solution with our products, contact us. As a
highly competent consultant and practically oriented implementer, we will
certainly be able to identify a solution in your case using our in-depth
knowledge gained from many applications.
Fans and blowers:
for commercial vehicle climate control
and cooling of individual components..
8
9
EC dual centrifugal blowers with brushless DC motor “Premium”
10
Type
K3G 097-AK32 -42(1)
K3G 097-AK36 -55(1)
Motor
M3G074-CF
M3G074-CF
VDC VDC m3/h rpm W A Pa dB(A) °C kg
13 9-15 750 3630 195 15,0 300 63 -40..+85(2) 2,3 A
13 9-15 1180 3740 385 29,5 0 69 -40..+85(2) 2,6 A
Curve
Nominal voltage
Nominal voltage
range
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 12-volt variant (2) at free air not recommended for long-term operation at 85 °C
A
B
0 100 200 300 400 500 600
1,0
200
2,0
400
600
3,0
800
1000
4,0
200 400 600 800 1000
cfm
Pa
in H2O
m3/h
qV
pfs
B
A
1
3
2
4
2
4
3
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
B
B
B
B
1
2
3
4
1
2
3
4
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
---
3630
3875
4135
3740
4400
4775
4970
---
195
177
143
385
344
309
234
---
63
64
65
69
68
69
70
---
15,0
13,5
11,0
29,5
26,4
23,8
18,0
Min. back pressure
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM (without plug)
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
11
75.5
100
104
335
351
18
10
45
64.5
90
101
217.5
60
136
10
2.5
11
60
139.5
170.5
Ø 4.5
Electr. connection
p. 53
Connection leads
p. 52
Direction
of rotation
450+20
8
View lead connection (K3G097-AK32-42)
UN black
PWM/LIN yellow
GND brown
450+20
6
View lead connection (K3G097-AK36-55)
UN black
PWM/LIN yellow
GND brown
Core-end sleeve tin-plated
as of housing as of housing
Temp. control mod.
p. 50 f.
12
Type
K3G 097-AK68 -85(1)(2)
Motor
M3G074-CF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 1560 4600 690 26,5 75 -40..+60(3) 2,4 G
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) housing/impeller also available in V0 material (3) short-term operation at up to 85 °C possible
A
A
0 200 400 600 800
0,8
200
1,6
400
600
3,22,4
800
1000
1200
4,0
200 400 600 800 1000 1200 1400
cfm
Pa
in H2O
m3/h
qV
pfs
1
3
2
4
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
4600
5095
5435
5720
690
604
526
365
75
74
74
74
26,5
23,2
20,2
14,0
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM (without plug)
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 3
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
13
Electr. connection
p. 55
75.5
100
104
335
351
18
10
45
64.5
90
101
217.5
60
136
10
2.5
11
60
139.5
170.5
Ø 4.5
Direction
of rotation
450+20
0
View connector plug
4-pole lead connection (450 mm) with plug Delphi Metri-Pack 280
Socket on customer side:
Housing: Delphi 12129565
Secondary lock: Delphi 15300016 (TPA lock)
Terminals: Delphi 12077411
Delphi 12077413
Seals: Delphi 15324981
Delphi 15324985
D (GND) brown
C (Diagnosis) white
A (+UB) black
B (PWM/LIN) yellow
1 kHz ... 50 kHz
0 V ... 10 V
Temp. control mod.
p. 50 f.
14
Type
K3G 097-AF24 -01(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A Pa dB(A) °C kg
26 16-32 1240 3730 390 15,0 0 70 -40..+85(2) 2,0 D
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations
A
(1) 24-volt variant (2) over + 70 °C with power derating
200 400 600 800 1000 1200
0 400100 200 300 700600500
600
0,8 2,4
800
3,2
1000
4,0
1
2
3
4
200
1,6
400
cfm
qV
pfs Pa
in H2O
m3/h
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
3730
4125
4490
4985
390
363
309
245
70
69
69
70
15,0
13,9
11,9
9,4
Min. back pressure
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
15
Electr. connection
p. 54
Ø 4.5
75.5
100
335
351
217.5
18
10
45
64.5
90
101
10
60
136
170.5
11
60
139.5
2.5104
1
3
5
2
4
6
View connector plug
1 = UN black
2 = GND brown
3 = PWM/LIN yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02001-4-1021 (not included in delivery)
Temp. control mod.
p. 50 f.
Connection leads
p. 52
16
Type
K3G 097-BF24 -01(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A Pa dB(A) °C kg
26 16-32 1150 3960 375 14,4 0 70 -40..+85(2) 2,0 D
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations
A
(1) 24-volt variant (2) over + 70 °C with power derating
200 400 600 800 1000 1200
0 400100 200 300 700600500
600
0,8 2,4
800
3,2
1000
4,0
1
2
3
4
200
1,6
400
cfm
qV
pfs Pa
in H2O
m3/h
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
3960
4265
4535
5090
375
345
309
223
70
69
69
71
14,4
13,3
11,9
8,6
Min. back pressure
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
17
Electr. connection
p. 54
144.5
163.5
3
92
6567
50
33.814.65
113.5
8.5
55
129
4.8
50
70
325
335
196
217.5
1
3
5
2
4
6
Temp. control mod.
p. 50 f.
Connection leads
p. 52
View connector plug
1 = UN black
2 = GND brown
3 = PWM/LIN yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02001-4-1021 (not included in delivery)
18
19
EC dual centrifugal blowers with brushless DC motor „Basic“
20
Motor
M3G074-CF
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Nominal data
subject to alterations (1) 24-volt variant (2) at free air not recommended for long-term operation at 85 °C
Type
K3G 097-AK34 -65(1)
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 1290 3830 394 15,2 72 -40..+85(2) 2,0 F
A
Electr. connection
0,8 1,2 1,6 2,0 2,4 2,80,4
2
5
6
7
8
10
11
12
9
3
4
1
A
0 100 200 300 400 500 600 700
200 400 600 800 1000 1200
100
200
300
400
500
600
700
800
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
A
A
A
A
5
6
7
8
A
A
A
A
9
10
11
12
3830
4100
4380
4630
3150
3330
3510
3660
2240
2340
2430
4480
394
347
285
238
215
185
149
120
79
67
53
43
72
69
68
68
68
65
63
62
59
56
54
53
15,2
13,3
10,9
9,1
8,3
7,1
5,7
4,6
3,1
2,6
2,0
1,7
80 %
100 %
60 %
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM (without plug)
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: e1 approval in accordance with 2006/28/EC
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
View connector plug
1 = + UB
2 = GND
3 = PWM/LIN, 100 % Speed
4 = 80 % Speed
5 = 60 % Speed
6 = NC (not assigned)
AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with
mating plug; part no. 02001-4-1021 (not included in delivery)
21
75.5
100
104
335
351
18
10
45
64.5
90
101
217.5
60
136
10
2.5
11
60
139.5
170.5
Ø 4.5
5
2
1
4
3
6
Direction
of rotation
Speed setting
5 4 3
60% H NC NC
80% NC H NC NC = not assigned
100% NC NC H H = UN(26 V)
Pin
Electr. connection
p. 55
Temp. control mod.
p. 50 f.
Connection leads
p. 52
22
Motor
M3G074-CF
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Nominal data
subject to alterations
Type
K3G 097-BK34 -65(1)
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 1110 4040 344 13,3 70 -40..+85(2) 2,0 F
A
Electr. connection
(1) 24-volt variant (2) at free air not recommended for long-term operation at 85 °C
0,8 1,2 1,6 2,0 2,4 2,80,4
2
5
6
7
8
10
11
12
9
3
4
1
A
0 100 200 300 400 500 600
200 400 600 800 1000
100
200
300
400
500
600
700
3,2
800
3,6
900
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
A
A
A
A
5
6
7
8
A
A
A
A
9
10
11
12
4040
4210
4380
4630
3310
3390
3520
3650
2330
2360
2410
2480
344
325
279
242
186
171
145
121
67
62
53
42
70
69
68
68
66
64
63
62
57
55
54
53
13,3
12,5
10,6
9,2
7,2
6,6
5,5
4,6
2,6
2,4
2,0
1,6
80 %
100 %
60 %
EC dual centrifugal blowers
with brushless DC motor, Ø 097
Material: Housing: PP plastic, coloured black (conforms to UL 94 HB)
Impeller: PA plastic
Type of protection: IP 24 KM (without plug)
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings on both sides
Motor protection: Overtemperature protection, locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: e1 approval in accordance with 2006/28/EC
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst scroll housing
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
23
196
217.5
8.5
55
129
113.5
50
67
325
70
4.8
50
65
144.5
92
3
163.5
335
5
2
1
4
3
6
Electr. connection
p. 55
Temp. control mod.
p. 50 f.
Connection leads
p. 52
Direction
of rotation
View connector plug
1 = + UB
2 = GND
3 = PWM/LIN, 100 % Speed
4 = 80 % Speed
5 = 60 % Speed
6 = NC (not assigned)
AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with
mating plug; part no. 02001-4-1021 (not included in delivery)
Speed setting
5 4 3
60% H NC NC
80% NC H NC NC = not assigned
100% NC NC H H = UN(26 V)
Pin
24
25
EC axial fans with brushless DC motor „Premium“ and „Power“
26
Type
W3G280-EQ20 -43(1)
Motor
M3G074-CF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 2400 3100 200 7,5 72 -40..+85(2) 2,4 D
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) at free air not recommended for long-term operation at 85 °C
A
A
A
A
A
1
2
3
4
3100
3085
3090
3105
200
197
192
213
72
72
74
76
7,5
7,6
7,3
8,2
1,0 1,50,5
2
3
4
1
A
0 250 500 750 12501000
400 800 1200 1600 2000
100
200
300
400
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
EC axial fans
with brushless DC motor, Ø 280
Material: Wall ring: PP plastic, coloured black
Impeller: PBT plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: IP 24 KM
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Nominal voltage
range
27
Electr. connection
p. 54
Ø303
298
325
+20
18
8.5
X
172
57
94+2
Ø294
Ø125
Ø292
8
21.7˚
4.3 1.5
4
1
6
2
5
3
View X
1 = UN black
2 = GND brown
3 = PWM/LIN yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
"V"
Temp. control mod.
p. 50 f.
Connection leads
p. 52
Type
W3G300-BV12 -41(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A dB(A) °C kg
13 9-16 2610 3200 220 16,7 75 -40..+105(2) 2,0 K
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 12-volt variant (2) over + 85 °C with power derating
A
A
A
A
A
1
2
3
4
3200
3140
2960
2840
220
235
247
248
75
75
73
75
16,7
18,1
18,9
19,0
1,0 1,20,80,60,2 0,4
2
3
4
A
0 250 500 750 1250 15001000
400 800 1200 1600 2000 2400
50
100
150
200
250
300
350
1
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
28
EC axial fans
with brushless DC motor, Ø 300
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
X
300+20
0
54
76.5+2
0
+2
0
16
Ø318+1
0
Ø340
Ø337
24°
9.5
7.5
4x90°
330
Electr. connection
p. 56
29
4
1
6
2
5
3
View X
1 = + UB black
2 = GND brown
3 = PWM/LIN* yellow
4 = NC (not assigned)
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
* optionally LIN-BUS
"V"
Temp. control mod.
p. 50 f.
Connection leads
p. 52
30
Type
W3G300-BV24 -01(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 2570 3160 205 7,90 74 -40..+110(2) 2,0 H
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) over + 95 °C with power derating
A
A
A
A
A
1
2
3
4
1,0 1,20,80,60,2 0,4
2
3
4
A
0 250 500 750 1250 15001000
400 800 1200 1600 2000 2400
50
100
150
200
250
300
350
1
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
3160
3150
3085
2965
205
216
240
244
74
73
73
73
7,90
8,30
9,20
9,40
EC axial fans
with brushless DC motor, Ø 300
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
31
View X
1 = + UB black
2 = GND brown
3 = PWM/LIN* yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
* optionally LIN-BUS
4
1
6
2
5
3
Electr. connection
p. 56
X
300+20
0
54
76.5+2
0
+2
0
16
Ø318+1
0
Ø340
Ø337
24°
9.5
7.5
4x90°
330
"V"
Temp. control mod.
p. 50 f.
Connection leads
p. 52
32
Type
W3G300-BV25 -21(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 3225 3940 380 14,6 79 -40..+110(2) 2,0 H
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) over + 85 °C with power derating
A
A
A
A
A
1
2
3
4
3940
3815
3715
3630
380
408
462
495
79
79
78
81
14,6
15,7
17,7
19,0
1,61,20,80,4
2
3
4
1
A
0 250 500 750 1250 15001000
500 1000 1500 2000 2500 3000
100
200
300
400
2,0
500
2,4
600
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
EC axial fans
with brushless DC motor, Ø 300
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
33
Electr. connection
p. 56
4
1
6
2
5
3
View X
1 = + UB black
2 = GND brown
3 = PWM/LIN* yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
* optionally LIN-BUS
X
300+20
0
54
76.5+2
0
+2
0
16
Ø318+1
0
Ø340
Ø337
24°
9.5
7.5
4x90°
330
"V"
Temp. control mod.
p. 50 f.
Connection leads
p. 52
34
Type
W3G300-ER38 -45(1)
Motor
M3G074-CF
VDC VDC m3/h rpm W A dB(A) Pa °C kg
27,5 16-32 3135 3320 335 12,2 87 275 -40..+85(2) 2,5 C
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Max. back pressure
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) at free air not recommended for long-term operation at 85 °C
A
A
A
A
1
2
3
3320
3295
3255
335
354
367
87
85
86
12,2
12,8
13,3
2
3
1
A
0 250 500 750 1250 15001000
500 1000 1500 2000 2500 3000
100
200
300
400
0,5 1,0 1,5
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
EC axial fans
with brushless DC motor, Ø 300
Material: Wall ring: PP plastic, coloured black
Impeller: PBT plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “A”, intake over struts
Type of protection: IP 24 KM
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
35
15˚
Ø6.8
360 +20
Ø337
Ø340
6˚40'
6
4x90˚
Ø330
Ø323
94+2
2.5
57
3.5
Ø315
+1
Ø318
7
3.5
X
Ø125
4.3 1.5
"A"
A
B
C
D
View X
A = UN rde
B = LIN blue
C = CGND white
D = GND black
Electr. connection
p. 54
Bushing on customer side:
Housing: Packard 12015797
Pins: Packard 12089188
Packard 12124580
Sealings: Packard 15324982
Packard 15324983
Temp. control mod.
p. 50 f.
36
Type
W3G385-CT53 -61(1)
Motor
M3G084-CF
VDC VDC m3/h rpm W A dB(A) °C kg
13 9-16 4110 3100 445 34,0 81 -40..+105(2) 3,3 L
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 12-volt variant (2) over + 70 °C with power derating
A
A
A
A
A
1
2
3
4
3100
3000
2930
2815
445
487
544
590
81
80
78
81
34,0
37,6
41,9
45,6
0,80,4
2
3
4
1
A
0 500 1500 20001000
500 1000 1500 2000 2500 3000 3500 4000
100
200
1,2
300
2,0
500
1,6
400
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
EC axial fans
with brushless DC motor, Ø 385
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
37
Electr. connection
p. 53
3
2
4
1
View X
1 = + UB black
2 = Diagnostic output* white
3 = PWM/LIN yellow
4 = GND brown
* optionally LIN-BUS
X
9.5
7.5
Ø422
Ø414
270
+20
0
399
24°
4x90°
55
89.5+2
0
+2
0
16
17
Ø396+2
0
±1
Bushing on customer side:
Housing: FCI 30432101
Pins: 9,5 mm FCI 60070461
4,8 mm FCI 60040431
Sealings: FCI 60993301
FCI 60992607
"V"
Temp. control mod.
p. 50 f.
38
Type
W3G385-BV44 -01(1)
Motor
M3G084-BF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 3425 2600 260 10,0 76 -40..+110(2) 2,7 H
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) over + 95 °C with power derating
A
A
A
A
A
1
2
3
4
2600
2505
2325
2215
260
272
273
274
76
74
73
74
10,0
10,5
10,5
10,5
0,80,60,40,2
2
3
4
1
A
0 250 500 750 1250 15001000
500 1000 1500 2000 2500 3000
50
100
150
200
1,0
250
1,2
300
1,4
350
cfm
Pa
in H2O
m3/h
qV
pfs
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
EC axial fans
with brushless DC motor, Ø 385
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
39
Electr. connection
p. 56
4
1
6
2
5
3
View X
1 = + UB black
2 = GND brown
3 = PWM/LIN* yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
* optionally LIN-BUS
X
9.5
7.5
Ø422
Ø414
270+20
0
399
24°
4x90°
55
79.5+2
0
+2
0
16
Ø396+2
0
"V"
Temp. control mod.
p. 50 f.
Connection leads
p. 52
40
Type
W3G385-CT65 -21(1)
Motor
M3G084-CF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 4375 3300 525 20,0 83 -40..+110(2) 3,1 L
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) 24-volt variant (2) over + 85 °C with power derating
A
A
A
A
A
1
2
3
4
3300
3180
3050
2920
525
615
610
610
83
81
80
80
20,0
23,7
23,5
23,6
1,61,20,80,4
100
200
300
400
2,0
500
2,4
600
cfm
Pa
in H2O
m3/h
qV
pfs
2
3
4
1
A
500 1500 20001000
500 1000 1500 2000 2500 3000 3500 4000
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
EC axial fans
with brushless DC motor, Ø 385
Material: Wall ring: PA plastic, coloured black
Impeller: PA plastic, coloured black (conforms to UL 94 HB)
Direction of rotation: Clockwise, seen on rotor
Direction of air flow: “V”, exhaust over struts
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, locked-rotor protection,
load dump protection, under-voltage detection
EMC requirements: VDE 0879-2, interference suppression grade 5
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
41
Electr. connection
p. 53
3
2
4
1
View X
1 = + UB black
2 = Diagnostic output* white
3 = PWM/LIN yellow
4 = GND brown
* optionally LIN-BUS
X
9.5
7.5
Ø422
Ø414
270
+20
0
399
24°
4x90°
55
89.5+2
0
+2
0
16
17
Ø396+2
0
±1
Bushing on customer side:
Housing: FCI 30432101
Pins: 9,5 mm FCI 60070461
4,8 mm FCI 60040431
Sealings: FCI 60993301
FCI 60992607
"V"
Temp. control mod.
p. 50 f.
42
43
EC centrifugal fans - RadiCal backward curved
44
EC centrifugal fan RadiCal
backward curved, Ø 220
Material: Impeller: Plastic PA 6.6 GV, coloured black
Electronics housing: Die-cast aluminium, coated in black
Direction of rotation: Clockwise, seen on rotor
Type of protection: Motor: IP 24, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position/condensate discharges:
Rotor on bottom with condensate discharge holes is standard
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: reverse polarity and locked-rotor protection
Technical features: Control input 0-10 VDC / PWM, tach output
Mounting situation: The parameters of the specific installation situation must be
co-ordinated with ebm-papst!
Type
R1G 220-RD02 -02(1)
Motor
M1G074-BF
VDC VDC m3/h rpm W A dB(A) °C kg
24 16-28 1030 2975 104 5,0 --- -40..+60 1,4 E
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) Also possible as 12-volt variant
A
200 400 600 800 1000
0400100 200 300 500 600
100
300
400
500
600
700
0,4 0,8 1,2 1,6 2,0 2,4
1
3
2
200
4
cfm
qV
pfs Pa
in H2O
m3/h
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
2975
2890
2775
2920
104
105
108
106
---
---
---
---
5,0
5,1
5,1
5,1
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
45
Type
R1G 220-RD02 -02
Inlet nozzle
09609-2-4013
Depth of screw
max. 6 mm
Number of blades = 7
Insulating sleeve with single strands 4x 0,75 mm2,
4 x brass lead tips crimped.
Electr. connection
p. 55
Cable assignment
UB red
Lin/PWM yellow
Tach output white
GND blue
Accessory part: Inlet nozzle
not included in the standard scope of delivery
Temp. control mod.
p. 50 f.
Ø220
Ø161
71
73.2
Ø58
45°
450
85
6
M4 (4x)
4x90°
0.8
R21.8
Ø88
63.7
Ø252
21
Ø155
±10
±0.15
+20
±0.2
±1
2
46
EC centrifugal fan RadiCal
backward curved, Ø 250
Material: Impeller: Plastic PA 6.6 GV, coloured black
Electronics housing: Die-cast aluminium, coated in black
Direction of rotation: Clockwise, seen on rotor
Type of protection: Motor: IP 24, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position/condensate discharges:
Rotor on bottom with condensate discharge holes is standard
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: reverse polarity and locked-rotor protection
Technical features: Control input 0-10 VDC / PWM, tach output
Mounting situation: The parameters of the specific installation situation must be
co-ordinated with ebm-papst!
Type
R1G 250-RC69 -02(1)
Motor
M1G074-CF
VDC VDC m3/h rpm W A dB(A) °C kg
24 16-28 1280 2440 105 4,9 --- -40..+60 1,9 E
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations (1) Also possible as 12-volt variant
A
200 400 600 800 1000 1200
0400100 200 300 700600500
600
0,8 2,4
1
2
3
4
200
1,6
400
cfm
qV
pfs Pa
in H2O
m3/h
0,4
100
1,2
300
500
2,0
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
A
A
A
A
1
2
3
4
2440
2275
2255
2425
105
108
110
105
---
---
---
---
4,9
5,2
5,2
4,9
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
47
Electr. connection
p. 55
Type
R1G 250-RC69 -02
Inlet nozzle
96359-2-4013
Number of blades = 7
Insulating sleeve with single strands 4x 0,75 mm2,
4 x brass lead tips crimped.
Cable assignment
UB red
Lin/PWM yellow
Tach output white
GND blue
Temp. control mod.
p. 50 f.
Depth of screw
max. 6 mm
Accessory part: Inlet nozzle
not included in the standard scope of delivery
89
Ø250
Ø255
Ø240
Ø164.5
31
Ø172.5
6
85
450
45°
Ø58
M4 (4x)
R28
4x 90°
Ø4.5(4x)
1.5
Ø88
85
±0.15
+20
±10
±1
+0.3
-0.5
2
48
EC centrifugal fan RadiCal
backward curved, Ø 280
400 800 1200 1600 2000 2400
2800
0800200 400 600 160014001000 1200
100
300
400
500
600
0,4 0,8 1,2 1,6 2,0 2,4
1
3
2
200
4
cfm
qV
pfs Pa
in H2O
m3/h
Curves n
rpm
Ped
W
I
A
LpA
dB(A)
Type
R3G 280-RU26 -81
Motor
M3G084-CF
VDC VDC m3/h rpm W A dB(A) °C kg
26 16-32 2750 2350 252 10,5 72 -40..+60 2,8 H
Curve
Nominal voltage
Flow rate
speed/rpm
Input power
Current draw
Sound pressure level
Perm. amb. temp.
Mass
Electr. connection
Nominal data
subject to alterations
A
A
A
A
A
1
2
3
4
2350
2300
2265
2315
252
300
328
298
72
68
68
69
10,5
12,5
13,7
12,4
Material: Impeller: Plastic PA, coloured black (conforms to UL 94 V0)
Rotor: Coated in black
Electronics housing: Die-cast aluminium, coated in black
Direction of rotation: Clockwise, seen on rotor
Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K
Insulation class: “B” in accordance with EN 60335-1
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,
load dump protection, under-voltage detection
Qualified to: DIN ISO 16750
Nominal voltage
range
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 58 ff.
49
148,5±1
127
Ø187.5 ±0.3
Ø294
Ø260
Ø176.7
Ø280
Ø4.5(x4)
1.25
Ø102.2
460+20
46
Ø182
14°
4x90°
M5
M6
M4
8
112
144
Ø75 ±0.2
Ø58 ±0.2
Ø115±0.2
Depth of screw max. 10 mm
(core removing hole prepared for self-tapping screw)
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
Depth of screw max. 12 mm
(core removing hole prepared for self-tapping screw)
4
1
6
2
5
3
X
Electr. connection
p. 53
Temp. control mod.
p. 50 f.
View X
1 = + UB black
2 = GND brown
3 = PWM/LIN* yellow
4 = INVLIN orange
5 = LOWER blue
6 = Diagnostic output white
AMP Junior Power Timer, 6-pole, coded;
connection lead (460 mm) with mating plug
Part no. 02002-4-1021 (not included in delivery)
* optionally LIN-BUS
Type
R3G 280-RU26 -81
Inlet nozzle
28000-2-4013
Accessory part: Inlet nozzle
not included in the standard scope of delivery
Number of
blades = 6
50
Part no.
50002-1-0174
VDC mA VDC mA k
Ω
°C kg
18-60 10 2-10 0,1 6,8 +30..+55 0,02
50003-1-0174 18-60 10 0-10 0,1 6,8 +10..+45 0,02
Temperature control module
Type of protection: IP42
Nominal data
subject to alterations
Nominal voltage
Current draw
Output voltage
Temperature
control range
Mass
Output current
Output impedance
Electr. connection:
Control function: Both designs have “cooling” as control function
Tolerance ±3 K
8
3,3
Ø3,5
Ø7+0,5
1±0,1
2,5
3+0,2
Ø4,9
6,9
13
5
84,7
45
37,5
6,5
38,5
450
85
6
+20
Output (yellow)
+(red)
(blue)
Core-end sleeve
blue
yellow
red
blue
yellow
white
red
Counter
Controller
Alarm
Speed display
Temperature control module
50002-1-0174
2-10 VDC
or 0-10 VDC
output
18-60 VDC
Connection Fans
Maximum ripple
± 3.5 %
Control input
0 - 10 VDC
Tach output,
pulses per revolution
GND
47 K
680 Ω
47 K
47 V
Isink max.
10 mA
U/V
10
2
0 30 55 Temp. °C
50003-1-0174
U/V
10
1
0106 45 Temp. °C
51
Part no.
50005-1-0174
VDC mA VDC mA k
Ω
°C kg
15-30 10 0-10 1,0 1,1 -20..+80 0,02
Ω
Electr. connection:
Output voltage depending on temperature:
Tolerance ±3 K
8
3,3
Ø3,5
Ø7+0,5
1±0,1
2,5
3+0,2
Ø4,9
6,9
13
5
84,7
45
37,5
6,5
38,5
450
85
6
+20
Output (yellow)
+ (red)
(blue)
Core-end sleeve
blue
yellow
red
0-10 VDC
output
15-30 VDC
Temperature sensor
U/V
10
0-20 80 Temp. °C
Temperature sensor
Type of protection: IP42
Nominal data
subject to alterations
Nominal voltage
Current draw
Output voltage
Output current
Output impedance
Temperature
measuring range
Mass
52
460
25
60
8
Part no.
02001-4-1021
02002-4-1021
Application
EC dual centrifugal blower
EC axial fan
460
25
60
8
02001-4-1021
02002-4-1021
Accessories
subject to alterations
Core-end sleeve
Core-end sleeve
Connection leads
53
Electrical connections
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
Speed setting
PWM 1 kHz - 50 kHz Speed setting with
potentiometer Full speed
100 % PWM -> n=max
10 % PWM -> n=min
0 % PWM -> Standby
Speed setting
0 V - 10 V
10 V -> n=max
1 V -> n=min
0 V -> Standby
1 k33 k
10 k
12 V
U
(black) UN +13 VDC
PWM/LIN
0 V to 10 V
GND
(yellow)
(brown)
REtyp. 75 k
4
3
2
1
PWM
+
-
A) 13 VDC electrical connection (EC dual centrifugal blowers “Premium”)
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
L) 13 VDC electrical connection (EC axial fans „Power“)
Speed setting
PWM 5 Hz - 100 kHz Speed setting with
potentiometer Full speed
100 % PWM -> n=max
15 % PWM -> n=min
0 % PWM -> Standby
Speed setting
0 V - 10 V
10 V -> n=max
1,5 V -> n=min
0 V -> Standby
1 k
10 k
12 V
(black) UB +13 VDC
PWM/LIN
0 V to 10 V
Diagnostic output
GND
(yellow)
(white)
(brown)
REtyp. 44 k
Diagnostic output
Operation:
output level low (U = 0 V)
Rotor locked or overtemperature
or overvoltage/undervoltage:
output level high (U = UB - 2 V)
Imax = 50 mA
Collective fault signal possible
4
2
3
1
0.05 k
PWM U
+
-
54
Electrical connections
Customer circuit
Notes on various control
possibilities and their applications
Connection Fan
C) 27.5 VDC electrical connection
U
+
-
Speed setting
5 V -> n=max
0.75 V -> n=min
0 V -> Standby
nmax
nmin
0.75 V 5 V
max. permitted
offset voltage ±1.5 V
(red)
(blue)
(white)
C
(black)
D
B
AUN +27.5 VDC
LIN
CGND
GND
REtyp. 17 k
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
D) 26 VDC electrical connection
INVLIN REtyp. 100 k
(orange)
4
The blower speed is
determined by the
input (pin 3, 4) that
gives the higher
speed.
Full speed
Standby threshold UB
Standby
Motor stops
Motor turns
Switch
on: typ. 1.5 V
off: typ. 1 V
Switch-on
threshold
32 V
U
21 V
21 V 32 V UB
Speed setting:
21 V -> n=min
0 V -> n=max
UB -> Standby
Speed setting
PWM 5 Hz - 100 kHz Speed setting with
potentiometer Full speed
100 % PWM -> n=max
15 % PWM -> n=min
0 % PWM -> Standby
Speed setting
0 V - 10 V
10 V -> n=max
1,5 V -> n=min
0 V -> Standby
4.7 k
10 k
12 V
(black) UN +26 VDC
PWM/LIN
0 V to 10 V
Diagnostic output
LOWER
GND
(yellow)
(white)
(blue)
(brown)
REtyp. 75 k
Diagnostic output
Operation:
output level low (U = 0 V)
Rotor locked or overtemperature:
output level high (U = UB - 2 V)
Imax = 50 mA
Collective fault signal possible
Speed - lower
Input
UB -> n/2
open -> n
2
5
6
3
1
47 k
0.05 k
PWM U
+
-
U
+
-
55
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
Speed setting
PWM 1 kHz - 50 kHz Speed setting with
potentiometer
Full
speed
100 % PWM->n=max
10 % PWM->n=min
0 % PWM->Standby
Speed setting
0 V - 10 V
10 V -> n=max
1 V -> n=min
0 V -> Standby
4,7 k
10 k
12 V
U
(black) UN +26 VDC
PWM/LIN
0 V .. 10 V
GND
(yellow)
(brown)
REtyp 75 k
4
3
2
1
PWM +
-
G) 26 VDC electrical connection (EC dual centrifugal blowers „Premium/Power“)
Temperature
control module
50002-1-0174
50003-1-0174
(white) DU
3 k Imax=10mA
Diagnostic output
Operation: output level
high (U = UB - 2 V)
Rotor locked or overtemp-
erature: output level
low (U = 0 V)
Imax = 10 mA
Collective fault signal
possible
22 k
E) 24 VDC electrical connection
Temperature
control module
50002-1-0174
50003-1-0174
Speed setting
PWM 1 kHz - 50 kHz
Speed setting
with
potentiometer
Full speed
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
Safe start at
UNom -30 % from 40 % PWM
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
Safe start at
UNom -30 % from 4 V Ucontr
33 K 4.7 K
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
red
white
blue
Maximum ripple
±3.5%
Tach output
pulses per revolution
GND
RE> 100 k
Isink max. 10 mA
680 Ω
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
yellow
Lin/PWM control input
0-10 VDC / PWM
F) 26 VDC electrical connection (EC dual centrifugal blowers “Basic”)
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
Speed setting
PWM 1 kHz - 50 kHz Speed setting
with
potentiometer
Full speed
Speed setting
0 V - 10 V
10 V -> n=max
1 V -> n=min
0 V -> Standby
4.7 k
10 k
12 V
UN +26 VDC
PWM/LIN
0 V to 10 V
(100 %)
GND
REtyp. 75 k
3
1
PWM U
+
-
10 V -> n=max
1 V -> n=min
0 V -> Standby
80 %
speed 60 %
speed
4
5
6
2
(60 %)
(80 %)
REtyp. 75 k
REtyp. 75 k
56
Electrical connections
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
K) 13 VDC electrical connection (EC axial fans „Premium“)
4
The blower speed is
determined by the
input (pin 3, 4) that
gives the higher
speed.
Speed setting
PWM 5 Hz - 100 kHz Speed setting with
potentiometer Full speed
100 % PWM -> n=max
15 % PWM -> n=min
0 % PWM -> Standby
Speed setting
0 V - 10 V
10 V -> n=max
1,5 V -> n=min
0 V -> Standby
10 k
12 V
(black) UB +13 VDC
PWM/LIN
0 V to 10 V
Diagnostic output
LOWER
GND
(yellow)
(white)
(blue)
(brown)
REtyp. 44 k
Diagnostic output
Operation:
output level low (U = 0 V)
Rotor locked or overtemperature
or overvoltage/undervoltage:
output level high (U = UB - 2 V)
Imax = 50 mA
Collective fault signal possible
Speed - lower
Input
UB -> n/2
open -> n
2
5
6
3
1
47 k
0.05 k
PWM U
+
-
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
H) 26 VDC electrical connection (EC axial fans „Premium/Power“)
INVLIN REtyp. 100 k
(orange)
4
The blower speed is
determined by the
input (pin 3, 4) that
gives the higher
speed.
Full speed
Standby threshold UB
Standby
Motor stops
Motor turns
Switch
on: typ. 1.5 V
off: typ. 1 V
Switch-on
threshold
32 V
U
21 V
21 V 32 V UB
Speed setting:
21 V -> n=min
0 V -> n=max
UB -> Standby
Speed setting
PWM 5 Hz - 100 kHz Speed setting with
potentiometer Full speed
100 % PWM -> n=max
15 % PWM -> n=min
0 % PWM -> Standby
Speed setting
0 V - 10 V
10 V -> n=max
1,5 V -> n=min
0 V -> Standby
4.7 k
10 k
12 V
(black) UB +26 VDC
PWM/LIN
0 V to 10 V
Diagnostic output
LOWER
GND
(yellow)
(white)
(blue)
(brown)
REtyp. 44 k
Diagnostic output
Operation:
output level low (U = 0 V)
Rotor locked or overtemperature
or overvoltage/undervoltage:
output level high (U = UB - 2 V)
Imax = 50 mA
Collective fault signal possible
Speed - lower
Input
UB -> n/2
open -> n
2
5
6
3
1
47 k
0.05 k
PWM U
+
-
U
+
-
1 k
NC
57
58
General performance parameters
Any deviations from the technical data and parameters described here
are listed on the product-specific data sheet.
Type of protection
The type of protection is specified in the product-specific data sheets.
Insulation class
The insulation class is specified in the product-specific data sheets.
Mounting position
The mounting position is specified in the product-specific data sheets.
Condensate discharge holes
Information on the condensate discharge holes is provided in the
product-specific data sheets.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Protection class
The protection class is specified in the product-specific data sheets.
Service life
The service life of ebm-papst automotive products depends on:
The service life of the bearing system
The service life of the bearing system depends mainly on the thermal load
on the bearing.
The majority of our products use maintenance-free ball bearings for
any mounting position possible.
The service life L10 of the ball bearings can be taken as approx. 40,000
operating hours at an ambient temperature of 40 °C, yet this estimate
can vary according to the actual ambient conditions.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
product-specific data sheets.
Depending on motor type and field of application, the following protective
features are realised:
Thermal overload protection (TOP), in-circuit
PTC/NTC with electronic diagnostics
Current limitation via electronics
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
59
Legal and normative directives
The products described in this catalogue are designed, developed and
produced in keeping with the standards in place for the relevant product
and, if known, the conditions governing the relevant fields of application.
Standards
Information on standards is provided in the product-specific data sheets.
EMC
Information on EMC standards is provided in the product-specific data
sheets.
Complying with the EMC standards has to be established on the final
appliance, as different mounting situations can result in changed EMC
properties.
Approvals
In case you require a specific approval for your ebm-papst automotive
product (e1, UL, etc.) please let us know.
Most of our products can be supplied with the relevant approval.
Information on existing approvals is provided in the product-specific
data sheets.
Air performance measurements
All air performance measurements are carried out on suction side and on
chamber test beds conforming to the specifications as per ISO 5801 and
DIN 24163. The fans under test are installed in the measuring chamber at
free air intake and exhaust (installation category A) and are operated at
nominal voltage, with AC also at nominal frequency, and without any
additional components such as guard grilles.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
Left: Endurance test room
Middle: Shock test
Right: Chamber test rig
Mechanical strain / performance parameters
All ebm-papst products are subjected to comprehensive tests complying
with the normative specifications. In addition to this, the tests also reflect
the vast experience and expertise of ebm-papst.
Vibration test
Vibration tests are carried out in compliance with
Vibration test in operation according to DIN IEC 68, parts 2-6
Vibration test at standstill according to DIN IEC 68, parts 2-6
Shock load
Shock load tests are carried out in compliance with
Shock load according to DIN IEC 68, parts 2-27
Balancing quality
Testing the balancing quality is carried out in compliance with
Residual imbalance according to DIN ISO 1940
Standard balancing quality level G 6.3
Should you require a higher balancing quality level for your specific
application, please let us know and specify this when ordering your
product.
Chemo-physical strain / performance parameters
Should you have questions about chemo-physical strain, please direct
them to your ebm-papst contact.
Fields of application, industries and applications
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room
technology, automotive and rail technology, medical and laboratory tech -
nology, electronics, computer and office technology, telecommunications,
household appliances, heating, machines and plants, drive engineering.
Our products are not designed for use in the aviation and aerospace
industry!
60
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
Axial and diagonal fans in direction of rotation “V” in full nozzle and
without guard grille
Backward curved centrifugal fans, free-running and with inlet nozzle
Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All acoustic values are established according to ISO 13347, DIN 45635
and ISO 3744/3745 to accuracy class 2 and given in A-rated form.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound power level (Lw), 10 microphones are distributed
over an enveloping surface on the intake side of the fan being tested
(see graphic). The sound power level measured can be roughly calculated
from the sound pressure level by adding 7 dB.
Measuring configuration as per ISO 13347-3 respectively DIN 45635-38:
10 measuring points
d D
h = 1,5d ... 4,5d
Measurement area S = 6d2+ 7d (h + 1,5d)
3d
2d
h
D
1,5d
Room for precision noise measuring
61
Combined level of multiple same-level sound sources
Adding 2 noise sources with the same level results in a level increase of approx. 3 dB.
The noise characteristics of multiple identical fans can be determined in advance based on
the noise values specified in the data sheet. This is shown in the diagram opposite.
Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound
pressure level of a fan is approximately 75 dB(A). The level increase measured from the dia-
gram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A).
Combined level of two different-level sound sources
The acoustic performance of two different fans can be predetermined based on the sound
levels given in the data sheet. This is shown in the diagram opposite.
Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper-
ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is
4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that
the overall sound level of the unit can be expected to be 76.5 dB(A).
Distance laws
Sound power level is independent of distance to the sound source. In contrast to this, sound
pressure level decreases the further away the noise source is. The adjacent diagram shows
the decrease in level under far sound field conditions. Far sound field conditions apply when-
ever the distance between microphone and fan is big when compared to fan diameter and
wavelength to be considered. For more information on far sound field, please consult the rele-
vant literature on this complex topic. Per doubling of distance, the level in the far sound field
decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in
levels can be considerably smaller. The following example only applies to far sound field
conditions and can vary strongly depending on the installation effects:
With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of
1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by
26 dB, i.e. a sound pressure level of 39 dB(A).
15
10 15 20 255 82 3
105 90
1
Number of sources of sound with identical level
Increase in sound pressure / sound power level
4 6 7 9
[dB]
[dB(A)]
3
12 16 20 2484
21 1,50
0
Difference in level with two sources of sound
Increase in sound pressure / sound power level [dB]
[dB(A)]
[dB]
[dB(A)]
0
10 20 50 10052
-10-26 -20-30-40
1
[m]
Distance
Decrease in sound pressure level [dB]
[dB(A)]
62
Heilbronn / Heidelberg
Dipl.-Ing. Mark Gartner
Gehrweg 12
D-74199 Unterheinriet
Phone +49 7130 404569-1
Fax +49 7130 404569-2
Mark.Gartner@de.ebmpapst.com
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 3 b
D-35075 Gladenbach
Phone +49 6462 4071-10
Fax +49 6462 4071-11
Ralph.Brueck@de.ebmpapst.com
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 2657 16-96
Fax +49 2657 16-76
Winfried.Schaefer@de.ebmpapst.com
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Landsbergerstraße 14
D-86932 Pürgen
Phone +49 8196 99877-54
Fax +49 8196 99877-55
Jens.Peter@de.ebmpapst.com
Nuremberg
Dipl.-Wirt.-Ing. (FH) Axel Resch
Steinsfeldstraße 80
D-74626 Bretzfeld
Phone +49 7946 94401-02
Fax +49 7946 94401-03
Axel.Resch@de.ebmpapst.com
Offenburg
Dipl.-Ing. (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 7802 9822-52
Fax +49 7802 9822-53
Ralf.Braun@de.ebmpapst.com
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1
D-73207 Plochingen
Phone +49 7153 9289-80
Fax +49 7153 9289-81
Rudi.Weinmann@de.ebmpapst.com
Ulm
M.Sc. Reinhard Sommerreißer
Am Silbermannpark 10
D-86161 Augsburg
Phone +49 821 6610-7023
Fax +49 821 6610-7024
Reinhard.Sommerreisser@de.ebmpapst.com
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 6106 841-0
Fax +49 6106 841-111
info@red-elektromechanik.de
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
info@breuell-hilgenfeldt.de
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 8104 897-0
Fax +49 8104 897-90
info@schweiger-gmbh.de
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
ebmpapst@breuell-hilgenfeldt.de
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstraße 1
D-74677 Dörzbach
Phone +49 7937 80355-20
Fax +49 7937 80355-25
info@hds-gmbh.net
www.hds-gmbh.net
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 30 944149-62
Fax +49 30 944149-63
Jens.Duchow@de.ebmpapst.com
Bielefeld
Dipl.-Ing. (FH) Wolf-Jürgen Weber
Niehausweg 13
D-33739 Bielefeld
Phone +49 5206 91732-31
Fax +49 5206 91732-35
Wolf-Juergen.Weber@de.ebmpapst.com
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 2925 800-407
Fax +49 2925 800-408
Hans-Joachim.Pundt@de.ebmpapst.com
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr.-Hermann-Krause-Straße 23
D-63452 Hanau
Phone +49 6181 1898-12
Fax +49 6181 1898-13
Christian.Kleffmann@de.ebmpapst.com
Halle
Dipl.-Ing. (TU) Michael Hanning
Lercheneck 4
D-06198 Salzatal / OT Lieskau
Phone +49 345 55124-56
Fax +49 345 55124-57
Michael.Hanning@de.ebmpapst.com
Hamburg
Ingenieurbüro Breuell GmbH
Ing. Dirk Kahl
Elektroingenieur
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-19
Fax +49 40 538092-84
Dirk.Kahl@de.ebmpapst.com
ebm-papst in Germany
Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com
www.ebmpapst.com
ebm-papst
Landshut GmbH
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com
www.ebmpapst.com
fan agent
compact fan agent
motor specialist
motor agent
63
Europe
Austria
ebm-papst Motoren & Ventilatoren GmbH
Straubingstraße 17
A-4030 Linz
Phone +43 732 321150-0
Fax +43 732 321150-20
info@at.ebmpapst.com
www.ebmpapst.at
Belarus
ebm-papst Bel AgmbH
P.O. Box 117
BY-220138 Minsk
Phone +375 17 3851556
Fax +375 17 3851556
info@by.ebmpapst.com
www.ebmpapst.by
Belgium
ebm-papst Benelux B.V.
Sales office Belgium-Luxemburg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 16 396-200
Fax +32 16 396-220
info@be.ebmpapst.com
www.ebmpapst.be
Bulgaria
ebm-papst Romania S.R.L.
Str. Tarnavei No. 20
RO-500327 Brasov
Phone +40 268 331859
Fax +40 268 312805
dudasludovic@xnet.ro
Croatia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Kaštanová 34a
CZ-620 00 Brno
Phone +420 544 502-411
Fax +420 547 232-622
info@ebmpapst.cz
www.ebmpapst.cz
Denmark
ebm-papst Denmark ApS
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 43 631111
Fax +45 43 630505
mail@dk.ebmpapst.com
www.ebmpapst.dk
Estonia
ebm-papst Oy, Eesti Filiaal
Kesk tee 13
Aaviku küla, Jüri Tehnopark
EST-75301 Rae Vald, Harjumaa
Phone +372 65569-78
Fax +372 65569-79
www.ebmpapst.ee
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 9 887022-0
Fax +358 9 887022-13
mailbox@ebmpapst.fi
www.ebmpapst.fi
France
ebm-papst sarl
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai Cedex
Phone +33 820 326266
Fax +33 3 88673883
info@ebmpapst.fr
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 210 9513-705
Fax +30 210 9513-490
contact@helcoma.gr
www.helcoma.gr
Hungary
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Iceland
RJ Engineers
Stangarhyl 1a
IS-110 Reykjavik
Phone +354 567 8030
Fax +354 567 8015
rj@rj.is
www.rj.is
Ireland
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
AuBren Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 57 8664343
Fax +353 57 8664346
sales@ie.aubren.com
www.aubren.com
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 0331 836201
Fax +39 0331 821510
info@it.ebmpapst.com
www.ebmpapst.it
Macedonia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
ebm-papst in Europe
64
Russia
ebm-papst Ural GmbH
Posadskaja-Strasse, 23(E), 3
RU-620102 Ekaterinburg
Phone +7 343 2338000
Fax +7 343 2337788
Konstantin.Molokov@ru.ebmpapst.com
www.ebmpapst.ur.ru
ebm-papst Rus GmbH
proezd 4529, vladenie 5, stroenie 1
RU-141000 Mytistschi, Oblast Moskau
Phone +7 495 9807524
Fax +7 495 5140924
info@ebmpapst.ru
www.ebmpapst.ru
Serbia & Montenegro
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 91 6780894
Fax +34 91 6781530
ventas@ebmpapst.es
www.ebmpapst.es
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 10 4544400
Fax +46 8 362306
info@ebmpapst.se
www.ebmpapst.se
Switzerland
ebm-papst AG
Rütisbergstrasse 1
CH-8156 Oberhasli
Phone +41 44 73220-70
Fax +41 44 73220-77
verkauf@ebmpapst.ch
www.ebmpapst.ch
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 232 3282090
Fax +90 232 3280270
akantel@akantel.com.tr
www.ebmpapst.com.tr
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 21
UA-03067 Kiev
Phone +38 044 2063091
Fax +38 044 2063091
mail@ebmpapst.ua
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane
GB-East Ilsley, Berkshire RG20 7LG
Phone +44 1635 2811-11
Fax +44 1635 2811-61
A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com
Netherlands
ebm-papst Benelux B.V.
Engelseweg 127
NL-5705 AC Helmond
Phone +31 492 502-900
Fax +31 492 502-950
verkoop@nl.ebmpapst.com
www.ebmpapst.nl
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 22 763340
Fax +47 22 619173
mailbox@ebmpapst.no
www.ebmpapst.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236 Warszawa
Phone +48 22 6757819
Fax +48 22 6769587
office@ebmpapst.pl
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda.
Centro Empresarial de Alverca
Rua de Adarse, Vale D’Ervas
Corpo D / Fracção 3
P-2615-178 Alverca do Ribatejo
Phone +351 218 394 880
Fax +351 218 394 759
info@pt.ebmpapst.com
www.ebmpapst.pt
Romania
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 331859
Fax +40 268 312805
dudasludovic@xnet.ro
ebm-papst in Europe
fan agent
compact fan agent
motor specialist
motor agent
65
America
Argentina
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 11 46576135
Fax +54 11 46572092
ventas@ar.ebmpapst.com
www.ebmpapst.com.ar
Brazil
ebm-papst Motores Ventiladores Ltda.
Av. José Giorgi, 301 Galpões B6+B7
Condominio Logical Center
BR-06707-100 Cotia - São Paulo
Phone +55 11 4613-8700
Fax +55 11 4777-1456
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S. de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com
www.ebmpapst.com.mx
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 860 674-1515
Fax +1 860 674-8536
sales@us.ebmpapst.com
www.ebmpapst.us
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 313 406-8080
Fax +1 313 406-8081
automotive@us.ebmpapst.com
www.ebmpapst-automotive.us
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 11 794-3434
Fax +27 11 794-5020
info@za.ebmpapst.com
www.ebmpapst.co.za
ebm-papst in America and Africa
66
ebm-papst in Asia and Australia
fan agent
compact fan agent
motor specialist
motor agent
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 21 5046-0183
Fax +86 21 5046-1119
sales@cn.ebmpapst.com
www.ebmpapst.com.cn
Hong Kong
ebm-papst Hong Kong Ltd.
Unit No. 13,9 / F
Technology Park, 18 On Lai Street
Siu Lek Yuen, Shatin N.T.
Hong Kong - P.R. of China
Phone +852 2145-8678
Fax +852 2145-7678
info@hk.ebmpapst.com
India
ebm-papst India Pvt. Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 44 25372556
Fax +91 44 25371149
sales@in.ebmpapst.com
www.ebmpapst.in
Indonesia
ebm-papst Indonesia
Representative Office
German Centre, 4th Floor, Suite 4470
Jl. Kapt. Subijono Dj. Bumi Serpong Damai
RI-15321 Tangerang
Phone +62 21 5376250
Fax +62 21 5388305
salesdept@id.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 3 9100300
Fax +972 3 5796679
polak@polak.co.il
www.polak.co.il
Japan
ebm-papst Industries Japan K.K.
12th Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 45 47057-51
Fax +81 45 47057-52
info@jp.ebmpapst.com
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 2 366213-24
Fax +82 2 366213-26
info@kr.ebmpapst.com
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Unit 12-2, Jalan USJ Sentral 3
Persiaran Subang, Selangor Darul Ehsan
MAL-47600 Subang Jaya
Phone +60 3 8024-1680
Fax +60 3 8024-8718
salesdept@my.ebmpapst.com
Singapore
ebm-papst SEA Pte. Ltd.
No. 23 Ubi Road 4
#06-00 Olympia Industrial Building
SGP-Singapore 408620
Phone +65 65513789
Fax +65 68428439
salesdept@sg.ebmpapst.com
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 7 557-4268
Fax +886 7 557-2788
eteco@ms22.hinet.net
www.ebmpapst.com.tw
Thailand
ebm-papst Thailand Co., Ltd.
99/9 Moo 2, Central Chaengwattana Tower
14th Floor, Room 1402
Chaengwattana Road Bangtarad, Pakkret
THA-11120 Nonthaburi
Phone +66 2 8353785-7
Fax +66 2 8353788
salesdept@th.ebmpapst.com
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 4 88608-26
Fax +971 4 88608-27
info@ae.ebmpapst.com
www.ebmpapst.ae
Vietnam
ebm-papst Vietnam
Representative Office
Room #102, 25 Nguyen Van Thu Street
District 1
VN-Ho Chi Minh City
Phone +84 8 39104099
Fax +84 8 39103970
linh.nguyen@vn.ebmpapst.com
67
Australia
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 9 837-1884
Fax +64 9 837-1899
sales@ebmpapst.com.au
www.ebmpapst.com.au
37659-7-8811 · 2012-09 · KD-1’
Printed in Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com