M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com August 2015
2/6
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
Accuracy
(combined non linearity, hysteresis, and repeatability)
Isolation, Body to any Lead
Long Term Stability (1 year)
Total Error Band (17-4PH)
Over compensated temperature range
Total Error Band (316L, ≤3k psi)
Over compensated temperature range
Total Error Band (316L, >3k psi)
Over compensated temperature range
< (Supply Voltage -9V) / 0.02A
<2ms (Voltage Output); <3ms (Current Output); Without Snubber
17-4PH or 316L Stainless Steel Port, 316L Stainless Steel Snubber
Gage Pressure Reference Vent
Under 1k psi, customer to ensure venting through mating connector
50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L
For custom configurations, consult factory.
Notes
Compensated Temperature: The temperature range over which the product will produce an output proportional to pressure within the
specified performance limits.
Operating Temperature: The temperature range over which the product will produce an output proportional to pressure but may not remain
within the specified performance limits.
Storage Temperature: The temperature range over which the product can be stored safely in occasions without pressure applied or power
input and remains rated performance. Beyond this temperature range may cause permanent damage to the product.
All configurations are built with supply voltage reverse and output short-circuit protections.
EN 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (8kV contact/15kV air)
IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz)
IEC 61000-4-4 Electrical Fast Transient Immunity (1kV)
IEC 61000-4-5 Surge Immunity (V+ to V-: ±2KV/42Ω; L to Case: ±1KV/12Ω; V- to V0: ±1KV/42Ω)
IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency
Fields (150K~80MHz, 10V level for voltage output models, 3V level for current output model)
IEC 61000-4-9 Pulse Magnetic Field Immunity (100A/m peak)
For all CE compliance tests, max allowed output deviation ±1.5 %F.S.