I-18
PRESSURE SWITCHES
Visit www.GemsSensors.com for most current information.
PS71 Series / p2of2 / 07-MAY-14
MINIATURE
1 Pressure Range Code
Insert Pressure Range Code from Table 1, below.
2 Pressure Fitting1
12L14 Zinc-Plated Steel
-2MNZ = 1/8˝ NPTM
-4MNZ = 1/4˝ NPTM
-8MNZ = 1/2˝ NPTM
-2MGZ = 1/8˝ BSPM (G type)
-4MGZ = 1/4˝ BSPM (G type)
-4MSZ = 7/16˝-20 SAE Male
-6MSZ = 9/16˝-18 SAE Male
-M10Z = M10 x 1.0, Straight
-M12Z = M12 x 1.5, Straight
-M14Z = M14 x 1.5, Straight
316 Stainless Steel
-2MNS = 1/8˝ NPTM
-4MNS = 1/4˝ NPTM
-2MGS = 1/8˝ BSPM (G type)
-4MGS = 1/4˝ BSPM (G type)
3 Circuit
-A = SPST/N.O.
-B = SPST/N.C.
-C = SPDT
4 Electrical Termination
-SP = Spade Terminals2
-FLXX = Flying Leads3
-FLSXX = Flying Leads w/PVC Shrink Tubing3
-ELXX = 1/2˝ NPT Male Conduit w/Flying Leads4
-CABXX = 18 AWG PVC Cable5
-H = DIN 43650A Male Half Only6
-HR = Right Angle DIN 43650A Male Half Only6
-HC = DIN 43650A 9mm Cable Clamp6
-HCR = Right Angle DIN 43650A 9mm
Cable Clamp6
-HN = DIN 43650A with 1/2˝ Female NPT Conduit6
-HNR = Right Angle DIN 43650A with 1/2˝ Female
NPT Conduit6
5 Options7
-V = Viton® Diaphragm
-E = EPDM Diaphragm
-N = Neoprene Diaphragm
-10A = 10A @ 125/250 VAC Max. Rating
-G = Gold Contacts
(for loads less than 12 mA @ 12 VDC)
-RD = Reduced Differential
(25% reduction typical)
-IP = Ingress Protection8
-OF = Oil Free Cleaned9
-R = Restrictor (low damping coefficient) Brass
-SR = Spiral Restrictor (high damping coefficient)
300 Series Stainless Steel10
-WF = Weather Pack Connector, Female
-WM = Weather Pack Connector, Male
-DE = Deutsch Connector, Male, DT04 Series
6 Fixed Set Point (optional)
A. Specify set point -FS
(in PSI or BAR, see example)11
B. Set Point Actuation
R on Rising Pressure
F on Falling Pressure
Example: -FS2BARF for 2 BAR Falling
or -FS20PSIR for 20 PSI Rising
Notes:
1. Other fittings available.
Consult factory.
2. 20% increase in deadband
typical.
3. 18˝ is standard. Specify lead
length in inches (max. 48˝).
e.g. -FL18 or -FLS30.
4. 18˝ is standard. Specify
lead length in inches (max.
48˝). e.g. -EL18 or -EL30.
5. 36˝ is minimum. Specify
cable length in inches. e.g.
-CAB36 or -CAB120.
6. DIN connectors require -C
SPDT circuit.
7. Options -10A, -G or -RD
cannot be combined.
8. Ingress Protection is
available only with -FL, -FLS
or -CAB Electrical
Termination choices.
Ingress Protection requires
Fixed Set Point -FS.
9. Requires stainless steel
housing.
10. -SR will result in wider
deadbands and slower
response time.
11. Set Point must be within
Pressure Range selected in
Step 1.
Pressure Range Code Pressure Range Accuracy* Average Deadband**
10 10-30 psi (0.7-2.1 bar) ±1.5 psi (0.103 bar) +2% of setting 3.5 psi (0.28 bar) +11% of setting
20 25-75 psi (1.7-5.2 bar) ±2.5 psi (0.172 bar) +2% of setting 3.5 psi (0.28 bar) +11% of setting
30 65-300 psi (4.5-20.7 bar) ±5.0 psi (0.345 bar) +2% of setting 20 psig (1.38 bar) +11% of setting
40 250-1000 psi (17.2-69.0 bar) ±15 psi (1.03 bar) +2% of setting 45 psig (3.10 bar) +12% of setting
50 1000-3000 psi (69-206.8 bar) ±30 psi (2.06 bar) +3% of setting 70 psig (4.83 bar) +12% of setting
60 2500-5000 psi (172.4-344.7 bar) ±50 psi (3.45 bar) +4% of setting 140 psi (9.65 bar) +13% of setting
* Accuracy and set point of units may change due to the effects of temperature.
** These numbers are for the standard microswitch. With either the -SP or -10A option, the values are typically 20% greater than those
listed. With the -RD option, the values will be typically 25% less than those listed. In certain applications deadband can be tailored
and controlled to customer specifications. Consult factory for details.
Table 1 — Pressure Range Codes
PS71 -10 -4MNZ -C -H -XX -XXXX
1 2 3 4 5 6
How To Order
Use the Bold characters from the chart below to construct a product code. Please reference Notes.