www.redingtoncounters.com
ABOUT REDINGTON
Since 1961 REDINGTON has offered products that have proven to be rugged
and manufactured to the highest quality standards. Over several decades we
have focused on bringing our customers quality products at competitive prices.
This catalog contains several new and innovative products confirming our
commitment to provide state-of-the-art solutions for our customers.
Over the past few years, we have committed to developing the capabilities to
provide the finest electronic solutions for our customers’ counting, elapsed time
indicating and controlling needs. We have done this while continuing to supply
and support our broad range of rugged mechanical and electromechanical
products. We stand ready to work with our customers to provide cost effective
solutions and to match the best technology with your applications.
CUSTOMER SERVICE
We are committed to providing the best customer service anywhere. We strive to
provide our customers with prompt replies, on time delivery and hassle free
customer satisfaction. Our goals are to serve our customers and take the extra
steps necessary to satisfy your requirements.
We provide field assistance backed up by competent technical support from our
headquarters location. We have Authorized Distributors and Representatives
throughout North America that stand ready to assist our customers. Contact your
local Sales Representative, or call us at the factory, to get the name of your
nearest authorized distributor.
REDINGTON COUNTERS, INC.
P.O. Box 608
130 Addison Road
Windsor, CT 06095
on the web...
web site: www.redingtoncounters.com
e-mail: info@redingtoncounters.com
(800) 395-7337
(860) 688-6205
Fax: (860) 688-1591
How to Contact Us
by Mail...
by Phone... by Fax...
Customer Service/Application Assistance
www.redingtoncounters.com
Table of Contents
Page#
Introduction 4
COUNTERS
Electronic
Model 33 LCD 8 digits, self powered 8
Model 3302 LCD Large 4 digit display PCB Mount, self powered 10
Model 52 LCD 8 digits, uni or bi-directional 11
Model 53 LCD 7 or 8 digits, self powered, AC, DC or switch input 13
Model 54 LCD 7 or 8 digits, PCB module, self-powered 15
Model 55 7 digits, 3 mountings, AC/DC, EEPROM, reset 52
Model 56 7 digits, 3 mountings, AC/DC, EEPROM, reset, “Alerts” 55
Model 57 7 digits, 3 mountings, DC, EEPROM, reset, multi-function, 1 or 2 displays 58
Model 59 7 digits, PCB mount, DC, EEPROM, reset, multi-function 61
Model 88 LCD 8 digits, EEPROM, multifunction, uni or bi- directional 85
Model 94 LCD 6 digits, 3 mountings, reset, large figures 16
Electromechanical
Model 10 General-purpose totalizer, 6 figures, versatile mountings 19
Model 10 General-purpose totalizer, 7 figures, versatile mountings 20
Model 40 Low cost, 6 or 7 figures, non-reset 21
Model 44 6 figures, non-reset 23
Model 48 Compact 6 or 7 figures, non-reset 24
Model 49 4 or 6 figures, push-button reset 26
Model 128 4 figures, rotary reset, panel or base mount 28
Model 300 6 figures, panel mount, push-button reset 29
Mechanical
Model 08 Rotary counter 30
Model 14 Small, rotary or stroke counter 31
Model 20 Medium duty, stroke counter 35
Model 22 Medium duty, rotary counter 36
Model 27 Heavy-duty, stroke counter, 5 figures 37
Model 28 Heavy-duty, stroke counter, 5 figures 38
Model 29 Heavy-duty, stroke counter, 6 figures 39
Model 29 Heavy-duty, rotary counter, 6 figures 40
Model 41 Combined register and totalizer, 3 or 4 figures 41
Model 46 Compact, 5 figure, stroke counter 42
Model 750 Rugged revolution counter 43
Model PCU Stroke counter, 3 or 4 figures 44
Hand Tally Counters
Model 18 Hand Tally counters 33
Model 19 Modular Tally counters 34
Model 46T Compact stroke counter with thumb lever, 5 figures 42
Model E1 LCD Hand Tally, 4 digits, self powered 17
Model E2/E3 LCD ADD and ADD/SUBTRACT 4 digit Hand Tally 18
PREDETERMINING COUNTERS
Electronic
Model 83 LCD 6 digits, 1/16 DIN, preset & batch counter, EEPROM, AC/DC 89
Model 88 LCD 8 digits, serial communications, EEPROM, AC/DC, analog I/O 85
Electromechanical
Model 58 4 or 6 figures, panel mount, SPDT switch 45
NEW!
NEW!
NEW!
www.redingtoncounters.com
Table of Contents
Page#
HOUR METERS
Electronic
Model 33 6 digits, totally sealed, 4 mounting, AC/DC inputs 46
Model 51 6 digits, totally sealed, 3 mountings, AC/DC/Inductive, “Alerts”, Tach. 48
Model 53 7 digits, LCD, self powered, AC, DC or switch input 50
Model 55 7 digits, 3 mountings, AC/DC, EEPROM, reset 52
Model 56 7 digits, 3 mountings, AC/DC, EEPROM, reset, “Alerts” 55
Model 57 7 digits, 3 mountings, DC, EEPROM, reset, multi-function, 1 or 2 displays 58
Model 59 7 digits, PCB mount, DC, EEPROM, reset, multi-function 61
Model 88 6 digits, panel mount, Hrs, Min., Sec., serial communications, EEPROM 87
Model 94 6 digits, 3 mountings, reset, large figures 63
Model 720 7 digits, rugged steel housing 64
Electromechanical
Model 77 6 figures, non-reset, panel mount 65
Model 710 5 figures reset, 6 figure non-reset, AC voltage, 3-Hole mount 66
Model 711/731 7 figures, non-reset, AC/DC voltages 67
Model 711/731 7 figures, non-reset, AC/DC voltages, distinctive styling 69
Model 711 6 or 7 figures, reset or non-reset, AC voltage, rectangular styling 70
Model 720 5 or 6 figures, rugged steel housing, designed to mil-spec. 71
Model 722 6 figures, totally sealed AC Hour Meter, 115/230VAC, 50/60Hz 72
Model 732 6 figures, totally sealed DC Hour Meter, 10-80 VDC 74
PREDETERMINING TIMERS
Electronic
Model 83 6 digits, 1/16 DIN, EEPROM, serial communications 94
Model 88 8 digits, EEPROM, serial communications 85
CONTROLLERS & INDICATORS
Electronic
Model 53 Tachometer, 4 digits, LCD, self powered, AC/DC inputs 76
Model 85 4 digits, 1/8 DIN, RED or Green display, input scaling, EEPROM 78
Model 88 8 digits, panel mount, serial communications, input scaling, EEPROM 85
Model 92 Hand Held Tachometer/LCD, rotary and linear speed indicator 98
DIGITAL PANEL METERS
Electronic
Model 85 3 1/2 digits, 1/8 DIN, temperature, rate, freq., volts, amps, ohms, modular 78
ENCODERS/SENSORS
Model 65 Incremental optical encoder, uni or bi-directional 100
Model 65 Proximity switch, DC voltage, for counting or rate input 101
APPENDICES
Glossary of terms 102
Part# Index 106
NEW!
NEW!
NEW!
www.redingtoncounters.com
4
Introduction
TOTALIZING COUNTERS
Totalizing counters are used to sum the total number of
cycles or inputs to a device. These counters have no
“outputs”. Totalizers can be Mechanical, Electromechanical
or Electronic.
Totalizers are typically used to total cycle count, piece
count, and linear length or to indicate position. Displays for
Mechanical & Electromechanical Totalizers are molded
figure wheels usually displaying 0-9 digits on a contrasting
background and have a count capacity of 3-8 figures.
Mechanical Totalizers
The input for Mechanical Totalizers can be Rotary, Stroke or
Rotary Ratchet. Mechanical Totalizers require no operating
power or sensor and are easy to install. For hand operated
applications you need to consider our Model 18, Model 19
or Model 46 with thumb lever option.
Right-hand top-going:
(rotation #4)
Right-hand top-coming:
(rotation #3)
Basic operation of a mechanical stroke counter
The illustration below shows the lever in the rest
position with a total shaft rotation of X+Y+Z. Although
these angles may differ from model to model, the total
shaft rotation contains a pre-travel (X), a count stroke
(Y), and an over-travel (Z). The lever must start in the
pre-travel area and continue through to the over-travel
area to register a count. It is recommended that the
spring furnished with the counter be used to simplify
adjustment of count stroke to drive mechanism.
Left-hand top-coming:
(rotation #1)
Left-hand top-going:
(rotation #2)
Note: This illustrates rotations
2 and 3 only.
SHAFT ROTATIONS: Arrows indicate shaft rotation to increase count.
Model 20
Model 18
Model 46
Punchpress Gaming
Inventory Printing Press
Typical Applications
www.redingtoncounters.com 5
Introduction
Electromechanical Totalizers
These count on AC or DC voltage input signals. Electro-
mechanical Totalizers are often used when it is desirable to
mount the totalizer in a “remote” location. The input can be
from a variety of sensors including a Proximity switch,
Photoelectric or Mechanical switch. Several choices are
available for mounting, reset and add-subtract counting.
Electronic Totalizers
Electronic Totalizers utilize LED’s or LCD’s as displays with
a variety of colors and digits sizes. The count capacity can
be up to 8 digits with leading “0” suppression. Electronic
Totalizers provide the user with several advantages over
Mechanical or Electromechanical Totalizers. Electronic
Totalizers are silent, have high- speed count/input
capability, interface easily with a variety of sensors, have
communications, programmable decimal points, input
scaling and quadrature inputs.
PREDETERMINING COUNTERS/TIMERS
Predetermining counters can provide the user with an output
signal when a preset number is reached. Typical
applications are controlling batch or lot size, positioning,
punching, converting or cut-to-length.
Electromechanical Predetermining Counters
Electromechanical predetermining counters are easy to
preset and apply. They are ideal for slow batch counting
and remote locations. They are limited on their count speed
and do not have automatic reset capability. The input signal
is an AC/DC voltage source and can come from switch or
relay contacts, photoelectric control or proximity switch.
Model 33
Model 53
Model 88
Model 94
Control Panels
Injection Molding Test Equipment
Office Equipment
Typical Applications
Typical Applications
Gaming Machines
Photocopiers
Printing Press
Typical Applications
Batch ControlProcess Control
Electronic Predetermining Counters/Timers
They provide an output signal, relay contacts or solid state,
when a preset number is reached. They can be used for
cut-to length, batch or cycle counting, punching and
positioning. They can also interface with most sensors
including Encoders, Proximity switches and Photoelectric
controls. Some models are available with an analog input
and output.
Model 58
Model 48
Model 40
Model 10
www.redingtoncounters.com
6
Introduction
Typical Applications
Models 83 Models 88
Cut-to-Length Batching
Typical Applications
Model 92Model 88Model 85
Hand-Held Tachometer
Flow Level and Control Temperature
Model 85
Typical Applications
Temperature Volts/Amps
They feature high speeds, silent operation, instant reset,
without loss of incoming counts, bi-directional count
capability, data communications, LED or LCD displays,
programmable decimal points and input scaling.
RATE INDICATORS AND CONTROLLERS
Rate Indicators and Controllers can be used to monitor or
measure frequency or RPM. Hand Held Tachometers are
available to measure RPM or Linear speed. Panel mount
indicators/controllers can display and control High-Low set-
point limits and provide an output signal for controlling.
DIGITAL PANEL METERS
Digital Panel Meters can be used to solve a wide range of
applications. These include, Indication or Controlling, Volts,
Current, Ohms, Temperature, Frequency and RPM. The
Redington Model 85 is modular and the main housing, with
modules, can be utilized to solve all of the applications
below. The Model 85 has “plug-in” modules, which can be
configured to the users needs or specifications. The 1/8
DIN enclosure is rated for IP65 and is available with a RED
or GREEN LED display.
HOUR/MAINTENANCE METERS
Hour/Maintenance Meters are used to record “running” hours
for preventive maintenance or warranty purposes. There are
several mounting variations available, 2-Hole rectangular,
flush-round, flush rectangular, 3-Hole round and PCB
Modules. Other models are available for mounting by a DIN
rail kit. A wide range of voltages, AC DC or Inductive,
makes the Meters adaptable to almost any application.
Most Hour Meters are available with 6-7 figures or digits.
“Redi-Alert” maintenance alarms can be programmed into
the Electronic meters. When the maintenance is due the
display will flash off - on and can provide an electrical
output by relay or solid- state circuit. Some Meters can
record Hour & Counts in the same model.
Electromechanical Hour Meters
Totally sealed Models are provided for harsh environments
that conform to SAE J1378 specifications. Models are
available with 6-7 figures on a contrasting background.
Manual-reset, remote reset and non-reset models provide a
wide choice of options. Most models are agency approved,
UL/cUL/CSA recognized and CE compliant. This technology
is time tested and has proven to be ultra reliable.
Model 88
www.redingtoncounters.com 7
Introduction
Typical Applications
Model 711 Model 720
Model 710
Test Equipment Control Panel
Electronic Hour Meters (LCD)
The standard mountings for the industry are available.
These products are microprocessor based and can be
specifically programmed for an application. Models are
available with Redi-Alerts, electrical outputs, tachometers,
battery operation, or EEPROM memory. Models are also
available with an Hour Meter and Counter in the same
meter. Totally sealed models conform to SAE-1378 and
NEMA 4X specifications.
Typical Applications
Generators
Construction Equipment Medical Equipment
Model 33
Model 53
Model 51
Model 57
www.redingtoncounters.com
8
Model 33 Electronic LCD Counter
Description
Features Options
Specifications
The Redington Model 33 line of LCD counters provides a large display, 7mm high figures, in an eight digit counter. The counters are
available in a variety of mountings: 2-hole rectangular, 3-hole round, flush-round and flush-rectangular. Voltage operating ranges are 10-
277 VDC AND 20-277VAC. All models are totally sealed from moisture and dirt and conform to NEMA 4 & 4X specifications when mounted
with the optional gasket. Their rugged construction makes them ideal replacements for current electromechanical counters. Units have
polarized LCD for high visibility in sunlight.
AC or DC voltage input in the same unit
Totally sealed from moisture and dirt
Always on display
Compact depth
Clip retainer mount or screws (supplied)
Custom logos and bezels
Terminations
Remote reset - dry contact with 6” wire leads
Gaskets
5003-002S gasket for 2-hole mount
5003-003S gasket for flush-rectangular mount
5003-004S gasket for flush-round mount
5003-005S gasket for 3-hole round mount
Display: LCD with large 0.28” [7mm] high figures,
black on light background
Records & Displays: 8 digit (99999999)
Inputs: 10 to 277VDC AND 20-277VAC
Vih* 20VAC or 10VDC minimum
Vil* 3VAC or 3VDC maximum
Speed: 25 counts per second
Battery Life: 7+ years
Shock: 44 to 55g’s, SAE J1378
Vibration: 20 g @ 10 to 80 Hz, SAE J1378
Humidity: 95% SAE J1378
Operating Temperature: -40°F to +185°F [-40°C to +85°C]
Sealing: Totally sealed, panel gaskets-NEMA 4 & 4X
Agency Approvals: CE compliant
UL/cUL recognized (file# ELIY2.E36690)
Termination: 0.250” [6.4mm] spades
Reset: Optional - dry contact with 6” wire leads
Case Material: Polymer (black)
Weight: 1oz [28g]
3301-0000 2-Hole Rect., 10-277 VDC AND 20-277VAC
3301-1000 3-Hole Round, 10-277 VDC AND 20-277VAC
3301-2000 Flush-Rect., 10-277 VDC AND 20-277VAC
3301-3000 Flush-Round, 10-277 VDC AND 20-277VAC
* Vih is the input high voltage. This is specified as the minimum input voltage that the Model 33 will recognize as a high level.
Vil is the input low voltage. This is specified as the maximum input voltage that the Model 33 will recognize as a low level.
3301-0010 2-Hole Rect., 10-277 VDC AND 20-277VAC, remote reset
3301-1010 3-Hole Round, 10-277 VDC AND 20-277VAC, remote reset
3301-2010 Flush-Rect., 10-277 VDC AND 20-277VAC, remote reset
3301-3010 Flush-Round, 10-277 VDC AND 20-277VAC, remote reset
Models Description Models Description
Note: When interfacing the Model 33 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
* All Items are normally in factory stock.
9
Model 33 Electronic
www.redingtoncounters.com
LCD Counter
Dimensions
Applications
2-Hole 3-Hole Round
Flush-Round Flush-Rectangular
Medical Devices Control Panels
Production EquipmentTest Equipment Office Equipment
In-front panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Behind panel cutout: 1.42 X 0.90 [22.9 x 36.1]
Secondary Equipment
Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Maximum panel thickness: 0.15 [3.8]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Maximum panel thickness: 0.15 [3.8]
0.25 [6.3]
1.43 [36.2]
0.99 [25.1]
0.12 [3.0]
0.34 [8.7]
0.93 [23.5]
0.44 [11.2]
Ø2.27 [57.7]
0.28 [7.0]
0.28 [7.0]
2.04 [51.9]
1.75 [44.4]
Ø.15 [Ø3.8]
1.10 [27.9]
0.44 [11.2]
0.34 [8.7]
0.93 [23.5]
0.25 [6.3]
1.43 [36.2]
0.99 [25.1]
0.06 [1.5]
0.06 [1.5] 1.41 [35.8]
0.89 [22.6]
0.28 [7.0]
0.12 [3.0]
0.25 [6.3]
0.99 [25.1]
1.43 [36.2]
Ø2.86 [72.6] 0.93 [23.5]
0.34 [8.7]
0.44 [11.2]
3X Ø.13 [Ø3.2] EQUALLY SPACED
ON A 2.53[89.7] B.C.
0.28 [7.0]
1.60 [40.6]
1.10 [27.9]
0.44 [11.2]
0.34 [8.7]
0.93 [23.5]
0.06 [1.5]
0.06 [1.5]
1.43 [36.2]
0.99 [25.1]
0.25 [6.3]
1.41 [35.8]
0.89 [22.6]
www.redingtoncounters.com
Model 3302
10
Electronic PCB Mount Counter
3302-4322 4-digit, LCD, 0.75" [19] PCB mount, dry contact closure input and remote reset
Description
Features Options
Specifications
Model Description
Dimensions
Applications
The Redington Model 3302-4322 LCD counter provides a very economical, large 4-digit display, 0.75" [19mm] with a PCB mount. The counter is
designed to accept dry contact or other solid-state switch-mode inputs. It has remote reset capability that is compatible with dry contact or switch-mode
inputs. The maximum pulse frequency is up to 30Hz. The counter is battery operated with a rated life of 5 years.
Large LCD display
Always on display
Contact closure input & remote reset
PCB mount
Non-reset
Display: Large 0.75" [19mm], LCD, black on light background
Displays: 4 digit (9999)
Inputs: Dry contact closure or solid-state switch-mode input
Remote Reset: Dry contact closure or solid-state switch-mode input
Battery Life: 5 years (with 50% input duty cycle)
Temp. Range: -40°F to 185°F [-40°C to 85°C]
Agency Approvals: CE Compliant
Termination: (6) 0.025 [0.64] square pins
Weight: 0.5oz, [14g]
Panel Builders Medical Devices Office EquipmentTest Equipment Events or People Counter
Rear View Side View Front View
Front Back
1.31 [33.3]
0.35 [9.0]
0.06 [1.5]
0.63 [16.0]
0.81 [20.6]
0.06 [1.5]
0.03 [.7]
0.99 [25.1]
2X 0.20 [5.1]
0.17 [4.3]
0.08 [2.1]
0.10 [2.4]
0.06 [1.6]
0.44 [11.2]
0.65 [16.4]
0.10 [2.5]
2.04 [51.8]
1.13 [28.8]
0.75 [19.0]
11
www.redingtoncounters.com
Model 52 Electronic LCD Totalizer
The Model 52 LCD 8-digit Miniature Electronic Counter offers a low cost general purpose miniature totalizer with a 10 year internal lithium battery.
It is an economical replacement for electromechanical counters and is available for bi-directional or quadrature inputs. Front panel reset button
can be enabled or disabled by a wiring connection or external contact closure. Easy snap in mount fits 0.94’’ x 1.89’’ [24 x 48mm] DIN panel cutout
(0.98’’ x 1.97’’ [25 x 50mm] with adaptor).
Contact closure/open collector low speed count input with
integral de-bounce circuitry (5200-0000)
Quad signal compatible using 5211-0000 plug-in adaptor.
This permits add/subtract counting in synchronization with
forward/reverse motion without count loss or gaining
additional counts. (5210-0000).
Front panel meets NEMA4/IP65 specification for indoor use.
Counting up to 10kHz.
7mm black characters, on a light background, LCD display.
Power: Internal lithium battery. Nominal life 10 years
Display: 8 digit black LCD, 0.3” [7.6mm]
characters with leading zero blanking
Manual Reset Enable: (PIN 2) link to COMMON (PIN 1) to
enable front panel reset button
Count Range: 99,999,999 display rollover to zero,
leading zeros suppressed
External Reset: (PIN 3) contact closure/open collector,
negative edge triggered. 0.7 threshold.
15mS minimum closure time
Direction Input: (Model 5210-0000) (PIN 4) connection
or electronic input TTL/CMOS
compatible. Add= no connection or >
2.4 volts (logic 1) ; subtract = connect
to COMMON or, 0.7V (logic 0)
direction input must precede count
input by 5µS (minimum) for valid
operation.
Optional triggering from any voltage between 5 and 240VAC
or VDC using the 5202-0000 adaptor and the Model
5200-0000.
Choice of mounting available, front panel with supplied bezel
or rear mounting clip.
5200-0000 Counter/Unidirectional, count up
5210-0000 Counter/Bidirectional, (Add/Subtract)
5201-0000 Terminal block adaptor
5202-0000 High voltage pulse adaptor (for use with 5200-0000 only)
5211-0000 Quadrature adaptor (for use with 5210-0000 only)
Description
Features Options
Specifications
Models DescriptionModels Description
Low Speed Count Input: (Model 5200-0000) (PIN4) contact
closure/open collector with integral de-
bounce circuitry. 30Hz maximum,
negative edge triggered, 0.7V
threshold, 15 mS minimum closure time
High Speed Count Input: (Model 5210-0000) (PIN 5) electronic
input 10kHz maximum, negative edge
triggered, 0.7 threshold 50µS minimum
pulse length, TTL/CMOS compatible
Operating Temperature: +14°F to +140°F [-10°C to +60°C]
Storage Temperature: -4°F to +140°F [-20°C to +60°C]
Environmental Protection: Front panel is NEMA4/IP65 using
gasket supplied.
Mounting: Either with clip mount or two front
screws with bezel supplied.
Approvals: UL Recognized, CE Compliant
Weight: 2 oz. [57g]
*Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 52
12
Electronic LCD Totalizer
Dimensions
1.77 [44.9]
0.86 [21.9]
1.20 [30.5]
0.16 [4.0]
0.94 [24.0]
1.97 [50.0]
1.50 [38.0]
1.89 [48.0]
2.36 [60.0] 0.12 [3.0]
COMMON
RESET ENABLE
EXTERNAL RESET
SLOW SPEED COUNT INPUT
HIGH SPEED COUNT INPUT
1. BLACK
2. GREEN
3. YELLOW
4. BROWN
5. BLUE
CONNECTION DETAILS
1.77 [44.9]
0.86 [21.9]
1.20 [30.5]
0.16 [4.0]
0.94 [24.0]
1.97 [50.0]
1.50 [38.0]
1.89 [48.0]
2.36 [60.0] 0.12 [3.0]
COMMON
RESET ENABLE
EXTERNAL RESET
DIRECTION
COUNT INPUT
1. BLACK
2. GREEN
3. YELLOW
4. BROWN
5. BLUE
CONNECTION DETAILS
48-240V
input
5-48V
input
to counter
opto-isotator
bi-directional
58.5K
4K7
48-240V
5-48V
count inputs
43
2
5
1
6
Counts inputs circuit configuration
connections to
rear screw terminals
SIGNAL COMMON
ENABLE
RESET EXTERNAL
RESET
Model 5200-0000
Model 5210-0000
High Voltage Adaptor
Terminal Block
Panel Cutout
1.87’’ x 0.87’’ [47.5 x 22.1] +0.02 - 0.0, )1.97’’ X 0.98’’ [50.0 x 24.9]
with panel adaptor.)
Accessory Descriptions
5201-0000 SCREW TERMINAL ADAPTOR
The 5201-0000 adaptor provides screw terminal connections for conductors up to 0.098in² [2.5mm2]. The adaptor snaps on to the rear of the counter.
The terminals are protected to the touch and are easily accessible.
5202-0000 HIGH VOLTAGE ADAPTOR
This is a plug in adaptor for use with the 5200-0000. This input adaptor module permits the use of high voltage input pulses from 5-240VAC or VDC.
Opto-isolation provides input to output isolation of 5000V. The adaptor plugs into the rear of the counter by integral clips. Connection is by screw terminal
for conductors up to 0.098in² [2.5mm2].
5211-0000 QUAD ADAPTOR
This is a plug-in adaptor for the (5210-0000) add/subtract counter. It converts the signal from a quadrature output sensor such as a shaft encoder
into count and direction signals. The adaptor retains direct access to the external reset on the 5210-0000. Connection by screw terminals for
conductors up to 0.098in² [2.5mm2].
Applications
RotationPositioningFlow Meter
High Voltage Adaptor Quadrature
Maximum Panel Thickness
0.3’’ [7.5mm]
www.redingtoncounters.com 13
Model 53 Electronic LCD Totalizer
The Model 53 Electronic Totalizer with 7 or 8 LCD digits is ideal as a replacement for electromechanical totalizers or where external power is not
available. Powered by an internal lithium battery these products are highly reliable and provide the user with a choice of several options; with or
without reset and multiple count ranges for optimized performance. The case is available in either tan or black.
Weight 2 oz. [57g]
Temperature:
Operating: -4°F to +140°F [-20°C to +60°C]
Storage: -40°F to +165°F [-40°C to +75°C]
Humidity: 0 to 95% RH, non-condensing
Vibration
Operating: 10 to 55Hz, 0.01” [0.25mm] double amplitude
Non-Operating: 10 to 55Hz, 0.03” [0.75mm] double amplitude
Shock
Operating: 10G
Non-Operating: 30G
Dielectric: 1000VAC 50/60Hz for 1 minute
Accuracy: 100% [Provided Signal Meets Stated Parameters]
Approvals: UL Recognized, CSA Certified, CE Compliant
Lithium battery
Choice of non-reset or remote reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Case color
Mounting adapter plates
8 digits
5003-001S - gasket
Low AC voltage (4-30 VAC)
Description
Features Options
Specifications
Models
All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
TERMINAL BLOCK WIRE LEADS
0.86 [21.8]
0.10 [2.5]
1.58 [40.0]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
Dimensions
0.86 [21.8]
0.10 [2.5]
1.72 [43.7]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
* Items in bold are normally in factory stock.
Figures: 7 or 8 LCD figures, 0.32’’ [8mm] high
Reset: Remote, manual, and non-reset
Speed:
7 Digit: 0-40 counts/second [min. 12.5ms - on, 12.5ms - off]
0-150 counts/second [min. 3.3ms - on, 3.3ms - off]
8 Digit: 0-35 count/second [min14.3ms - on, 14.3ms - off]
Inputs: Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Vih 20VAC/3VDC minimum
Vil 3VAC/1VDC maximum
Power: Self-powered (internal lithium battery)
Mounting: Panel with clip
Terminations: Terminal block, or connector with 8’’ [200mm]
wire leads
Battery Life: ~20years
5300-0000 XX XX X
5300-0001 X X X X X
5300-0100 XXX XX X
5300-0101 X X X X X X
5300-1000 XXXXX
5300-1001 X X X X X
5300-1100 XX X XX X
5300-1010 X X X X X
5300-1011 X X X X X
5300-2000 XXXXX
5300-2001 X X X X X
5300-2100 XX X XX X
5300-2200 X X X X X
5300-2201 X X X X X
Models Reset Input Speed/cps Terminations Color
remote none manual switch 3-30VDC 20-250VAC/VDC 40/150 40 term. block 8” wire leads Tan Black
Note: When interfacing the Model 53 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
www.redingtoncounters.com
Model 53
14
Electronic LCD Totalizer
NOTES:
INPUT / RESET PARAMETERS
To insure proper performance from totalizers the following minimum input durations are required:
0 to 35 cps totalizer Minimum 14.3 ms “on” 14.3 ms “off” The count is activated on the falling edge.
0 to 40 cps totalizer Minimum 12.5 ms “on” 12.5 ms “off” The count is activated on the falling edge.
0 to 150 cps totalizer Minimum 3.3 ms “on” 3.3 ms “off” The count is activated on the rising edge.
All resettable totalizers can be reset by a pulse with a minimum duration of 6 milliseconds.
DUAL RANGE TOTALIZER PROTECTION FEATURE:
Dual range totalizers have a built-in range protection feature. This feature will protect the totalizer from receiving a false signal from the unused input
line. Once a totalizer has received an input from pin #1 or pin #2, it will only accept inputs from that pin until the unit has been reset. For example, if a
totalizer is run in the low speed range and it is determined that a high speed range is preferred, simply switch the input from pin #2 to pin #1 and reset the
totalizer to de-activate this range protection feature. Conversely, if a totalizer is run in high speed range and it is determined that a low speed range is
preferred, simply switch the input from pin #1 to pin #2 and reset the totalizer.
SPECIAL WIRING OPTION
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option does not apply
for units with input of 20 - 250VAC/VDC or manual reset enable.
OPTIONAL INPUTS:
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
Operating Instructions
Number of Parts Shear Packaging Line
Applications
MOUNTING:
Unit Optional
Gasket Panel Clip
WIRING:
The mounting clip accommodates panel thicknesses up to 1/4”
[6.4mm].
Panel adapter plates are available in flush and 2 hole mount to fit
various panel cutouts. Consult the factory for availability.
Color code for the 8” [203mm] lead wires (24AWG) are:
1 - Yellow
2 - Blue
3 - Black
4 - Violet
5 - Gray
1.79 +/- 0.01
[45.5 +1/-0]
0.89 +/- 0.01
[22.6 +1/-0] Panel Cutout
Pin 1 not used
RESET
INPUT
20 - 250VAC/VDC
1 2 3 4 5
AC/DC AC/DC
RESET
INPUT
Pin 1 used for 0 - 150 cps only
3 - 30 VDC
1 2 3 4 5
+DC
+DC
Terminal block will accept wire sizes from 14 to 24AWG.
3 - 30VDC units are protected for transient voltages up to 50 volts
with pulse widths of up to 1 second at a 1% duty cycle (including
reverse polarity).
The operating AC frequency range is 40 to 400Hertz.
SWITCH (non-voltage)
RESET
INPUT
Pin 1 used for 0 - 150 cps only
1 2 3 4 5
15
www.redingtoncounters.com
Model 54 Electronic PCB Mount Totalizer
5400-0010 40/150 cps, switch, remote reset, w/battery
Description
Features Options
Specifications
Models Description
Dimensions
Applications
The Model 54 is a 7 or 8 digit LCD Totalizer with PCB mounting. Ideal for applications where PCB mounting, high reliability and long life are
important. Units are 7 or 8 digits and come with their own lithium battery. Totalizers have two count speed ranges, 40cps or 150cps and are
customer selectable.
Remote or non-reset
Selectable count speeds
High reliability
PCB mounting
Long life lithium battery
Dry contact closure or voltage pulse input
Hour Meter
Tachometer
Without battery
8 digits
Figures: 7 LCD , 0.315" (8mm)
Reset: Remote and non-reset
Speed: 7 Digit: 0 - 40 counts/second (min. 12.5ms-on, 12.5ms-off)
0 - 150 counts/second (min.3.3,s-on, 3.3ms-off)
8 Digit: 0 - 35 counts/second (min. 14.3ms-on,14.3ms-off)
Inputs: Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Vih 20VAC/3VDC minimum
Vil 3VAC/1VDC maximum
Power: Lithium battery (rated @ ~ 20 years)
Mounting: PCB: 0.45" Dia. [11.4mm] Pins, 0 .2" [5.1mm]
spacing:
Temperature:
Operating: -4°F to +140°F [-20°C to +60°C]
Storage: -40°F to +165°F [-40°C to +75°C]
Weight: 2oz [57g]
1.65 [41.9]
0.30 [7.6]
1.14 [29.0]
1.46 [37.1]
0.40 [10.2]
0.31 [7.9]
0.73 [18.5]
Ø.045 [1.14]
0.17 [4.3]
0.43 [10.9]
4X .20 [5.0]
5400-0010
Number of Parts Total Operating Time Motor/Pulley Speed
5400-1010 40/150 cps, 3-30VDC, remote reset, w/battery
Models Description
* All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
www.redingtoncounters.com
Model 94
16
Electronic LCD Totalizer
A 6 figure, battery powered, push-button or key reset, electronic counter, available in base mount or panel mount configuration. No external
power supply is required. Large 0.50’’ [12mm] LCD figures for fast, easy reading. Operates at 6-240 VAC or VDC. Long lasting internal lithium
battery. Attractive styling and silent operation make these models equally well-suited for lab or office equipment applications.
Figures: 6 LCD figures, 0.50’’ [12mm] high
Reset: Push-button, or lock and key
Speed: 0-40 counts/second, (min. 12.5ms - on, 12.5ms - off)
Input: 6-240VAC or VDC
Vih 6VAC/VDC minimum
Vil 2VAC/VDC maximum
9415-001 6 figure, base mount, push-button reset
9415-003 6 figure, panel mount, push-button reset
9415-005 6 figure, panel mount, lock and key reset
Base Mount Panel Mount
Mounting holes: 0.14’’ x 0.24’’ [3.6mm x 6.1mm] slots Panel cutout: 3.0’’ x 1.75” [76.2mm x 44.5mm]
Mounting holes: 0.17’’ [4.3mm] Dia.
Applications
Dimensions
Models Description
Description
Features Options
Specifications
Non-reset
Remote reset
No external power supply needed
Long life lithium battery
Large easy reading display
Operates at 6 to 240 VAC or VDC
Office equipment Production Test labs Control panels
Mounting: Base or panel
Terminations: (2) #22 AWG 221°F [105° C] wire leads,
8’’ [203mm] long
Temp. Range: -14°F to +122°F [-26°C to +50°C]
Power Source: Internal lithium battery
Weight: 18 oz. [510g]
1.75 [44.4]
2.97 [75.3]
1.65 [41.9]
3.15 [80.0]
3.81 [96.8]
3.23 [82.0]
3.31 [84.1]
0.88 [22.2]
1.36 [34.4]
1.87 [47.6]
1.50 [38.1]
4.06 [103.2]
3.15 [80.0]
4.44 [112.7]
1.65 [41.9]
2.90 [73.5]
1.41 [35.8]
Panel Mount/Lock & Key Reset
1.41 [35.8]
2.90 [73.5]
3.15 [80.0]
5.50 [139.7]
2.12 [54.0]
1.65 [41.9]
1.75 [44.5]
5.13 [130.2]
Panel cutout: 4.75 ’’ x 1.50” [76.2mm x 44.5mm]
Mounting holes: 0.17’’ [4.3mm] Dia.
* Items in bold are normally in factory stock.
Note: When interfacing the Model 94 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
17
www.redingtoncounters.com
Model E1 Electronic Tally Counter
Description
Features
Specifications
Models Description
Dimensions
Applications
Food portions
A hand-held reset counter with a 4 digit LCD display and push-button actuator. Case is made of a high impact plastic and comes with a key chain
for ease of use. All electronic construction provides a long life counter with no mechanical parts to wear out. The Tally is a handy way to count
inventory, attendance, traffic, blood cells, or food portions.
Digits: 4 LCD’s 0.24’’ [6mm] high
(maximum count 9999)
Reset: Push button
Battery Operating Life: 250 days (typical)
Weight: 0.7 oz [20g]
Color: Gray body with yellow buttons
Operating Instructions
1. Press ON/RESET key to power ON the unit.
2. Press STEP key once, the LCD will display ‘1’
3. Press START key, the LCD will display ‘1’
4. Press COUNT key to continue the counting, the LCD will display
from 1 to 2 to 3 to 4 etc.
Anytime you want to restart the count from ‘0’, repeat the above steps.
Note: If ‘0000’ is displayed, you can press 1 ON/RESET to reset to ‘0’
When the display gets dim or the counter works erratically,
replace the button type battery. Use 1 X G13A or equivalent.
Battery Replacement
Off
2
4
3
1
2.0”L x 1.7”W x 0.7”D [50.8mmL x 43.2mmW x 17.8mmD]
E1-1804 Electronic Hand Tally
* Item is normally in factory stock.
LCD display
Long life
Inventory Attendance Traffic Blood cells
www.redingtoncounters.com
Model E2 & E3
18
Electronic LCD Tally Counter
Description
Specifications
Applications
The Redington Models E2 & E3 offer an electronic version of the popular Hand Tally counter and are available with a choice of Add only or
Add/Subtract models. Counts are input using large positive action buttons. The Add model has a single count button and the Add/Subtract model
has two separate count buttons. The “+” button (green) will add a count to the total and the “-” button (red) will subtract a count from the total.
When activated, an audible “beeper” sounds every count to verify that a count has been registered. All electronic components provides a long life
counter with no moving parts to wear out. The counter is manufactured from impact-resistant plastic, combining lightweight with outstanding durability.
Display: 4 digit LCD 0.35" [9mm] high
Battery Operating Life: 250 days (without sound)
Reset: Push button
E2-1804 Electronic Hand Tally (Add only)
E3-1804 Electronic Hand Tally (Add/Subtract)
* All Items are normally in factory stock.
Add or Add/Subtract models
Beep at every count with the option of switching the
sound off for silent operation
Cannot accidentally reset or turn off; On/Off/Reset button
must be held down for 3 seconds to reset
Long life battery (replaceable) - typically 250 days without
sound
Large LCD display
No mechanical parts to wear out
Large rubber buttons for comfort of use
Ergonomically designed for ease of use
Carrying cord
Light weight
2.4" L x 1.4" W x 0.6" D [60mm x 35mm x 15mm]
Press On/Off/Reset button to power ON the unit
Add model - Press count button to increment count
Add/Subtract model - Press the “+” button to Add, Press
the “-” button to Subtract
To reset counter press the On/Off/Reset button for 3 seconds
To switch the sound Off/On at any time, hold the count button
down for 3 seconds
To turn Off, press the On/Off/Reset for 3 seconds when
counter display is at “0”
When the display gets dim, replace the battery.
Use 1 type AG10 1.5 V or equivalent
Observe polarity (±) during replacement
Food portions
Inventory Attendance Traffic Blood cells
Features
Models Description Dimensions
Operating Instructions Battery Replacement
Add Model Add/Subtract Model
Operating Temperature: +32°F to +122°F [0°C to +50°C]
Weight: 0.7 oz (20g)
Color: Black case with blue buttons (Add Only) or
green and red buttons (Add/Subtract)
19
www.redingtoncounters.com
Model 10 Electromechanical Totalizer
A 6 figure general purpose, rugged, electromechanical counter, either panel or base mounted, with manual knob reset, key reset, or non-reset.
Frame and housing provides rigid support for accurate alignment and trouble-free use. Distinctive numerals enhance visibility under adverse
viewing conditions.
Figures: 6 figures, white on black, 0.19’’ [5mm] high
Reset: Knob, lock and key, or non-reset
Speed: 1,000 counts/minute (min. 30ms - on, 30ms - off)
Voltage: 24, 115, 230 VAC or 24 VDC
(+/- 10%, but not to exceed 10 volts)
Power: 7.8 watts (nominal)
Voltages
Lead lengths
Terminations
Mounting
1071-024S - additional key for model 1026
Mounting: Base or panel
Terminations: (2)#22 AWG 105°C wire leads, 8’’ [203mm] long
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 18 to 22 oz. [510 to 624g]
1-1006 230VAC, base mount, knob reset
2-1006 115VAC, base mount, knob reset
3-1006 24VAC, base mount, knob reset
8-1006 24VDC, base mount, knob reset
2-1016 115VAC, base mount, non-reset
P1-1006 230VAC, panel mount, knob reset
P2-1006 115VAC, panel mount, knob reset
P3-1006 24VAC, panel mount, knob reset
P8-1006 24VDC, panel mount, knob reset
P2-1016 115VAC, panel mount, non-reset
P31-1026 230VAC, panel mount, lock and key reset
P32-1026 115VAC, panel mount, lock and key reset
P33-1026 24VAC, panel mount, lock and key reset
P38-1026 24VDC, panel mount, lock and key reset
1234561.63
[41.4]
3.68 [93.4]
2.81 [71.4]
3.23 [82.1]
3.31 [84.1] 2.51 [63.8]
1.74 [44.2]
1.30
[32.9]
0.88
[22.3]
4.06 [103.1]
1.62 [41.1]
123456
1.87 [47.5]
1.50 [38.1]
2.27 [57.7]
4.45 [113.0]
5.55 [140.9]
5.13 [130.3]
1.61 [40.9]
1234562.12 [53.9]
1.75 [44.5]
2.27 [57.7]
Base Mount Panel Mount
Lock and Key Reset
Mounting holes: 0.15’’ [3.8mm] Dia. Screws provided: 6-32 x 0.6 [15.2mm]
Panel cutout: 3.85’’ x 1.75’’ [97.8 x 44.5mm]
Screws provided: 6-32 x 0.6 [15.2mm]
Panel cutout: 4.88’’ x 1.75’’ [124.0 x 44.5mm]
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Panel or base mount
Rigid support for accurate alignment
Enhanced visibility
Manual knob, key or non-reset
Applications
Test labsMolding machines Printing pressesPunch press Secondary Machines
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 10
20
Electromechanical Totalizer
Applications
A 7 figure, rugged, electromechanical counter, either panel or base mounted, with manual knob reset, key reset, or non-reset. Frame and housing
provides rigid support for accurate alignment and trouble-free use. Large, easy-to-read numerals assure readability.
Figures: 7 figures, white on black, 0.19’’ [5mm] high
Reset: Knob, lock and key, or non-reset
Speed: 1,000 counts/minute
(min. 30ms - on, 30ms - off)
Voltage: 24, 115, 230 VAC or 24 VDC
(+/- 10%, but not to exceed 10 volts)
Power: 7.8 watts (nominal)
Voltages
Lead lengths
Terminations
Wheel color
Mounting: Base, panel, or behind the panel
Terminations: (2)#22 AWG 105°C wire leads, 8’’ [203mm] long
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 14 to 18 oz. [397 to 510g]
1-1007 230VAC, base mount, knob reset
2-1007 115VAC, base mount, knob reset
3-1007 24VAC, base mount, knob reset
8-1007 24VDC, base mount, knob reset
2-1017 115VAC, base mount, non-reset
P2-1007 115VAC, panel mount, knob reset
P2-1027 115VAC, panel mount, lock and key reset
P8-1027 24VDC, panel mount, lock and key reset
R2-1007 115VAC, behind the panel, knob reset
R2-1017 115VAC, behind the panel, non-reset
1234567
3.67 [93.3]
3.95 [100.3]
2.88 [73.2]
0.87 [22.2]
3.31 [84.1] 2.51 [63.8]
1.50 [38.1]
4.44 [112.9]
4.07 [103.3]
1.50 [38.1]
1.88 [47.6]
1.50 [38.1]
4
3
21 567
2.42 [61.4]
5.54 [140.7]
5.13 [130.3]
1.50 [38.1]
1.75 [44.5]
2.12 [54.0]
4
3
21 567
2.49 [63.1]
Base Mount Panel Mount
Lock and Key Reset
Mounting holes: 0.15’’ [3.8mm] Dia. Screws provided: 6-32 x 0.6 [15.2mm]
Panel cutout: 3.85’’ x 1.75’’ [97.8 x 44.5mm]
Screws provided: 6-32 x 0.6 [15.2mm]
Panel cutout: 4.88’’ x 1.75’’ [124.0 x 44.5mm]
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
7 figure
Panel or base mount
Rigid support for accurate alignment
Large easy to read numerals
Test labsMolding machines Printing pressesPunch press Secondary Machines
21
www.redingtoncounters.com
Model 40 Electromechanical Totalizer
Low cost
Small size
DC and AC
6 or 7 figure
Multiple mounting choices
Voltages
Figures: 6 or 7 figures, white on black, 0.12” (3 mm) high
Reset: Non-reset
Speed: 600 counts/minute (min. 50ms - on, 50ms - off)
Voltage: 115 VAC, 5, 12 or 24 VDC (+ 10/-15% tolerance)
Power: 1.4 watts AC, 1.0 watts DC (nominal)
Mounting: Rear, behind the panel, snap-in, base or PCB mount
Terminations: (2)#22 AWG 221°F [105°C] wire leads,10.5”
[266.7mm] long or (2) 0.03” [0.8mm] Dia. pins for PCB
mounting
Operating Life: Beyond 3 million counts
Temp. Range: +23°F to +104°F [-5°C to +40°C]
Weight: Less than 1 oz. [28g]
2-4016 115VAC, 6 figure, rear mount, wire leads
R2-4016 115VAC, 6 figure, behind the panel mount, wire leads
R9-4016 12VDC, 6 figure, behind the panel mount, wire leads
SR2-4016 115VAC, 6 figure, snap-in panel mount, wire leads
T2-4016 115VAC, 6 figure, PCB mount, pins
V8-4016 24VDC, 6 figure, V-base mount, wire leads
2-4017 115VAC, 7 figure, rear mount, wire leads
R2-4017 115VAC, 7 figure, behind the panel mount, wire leads
R9-4017 12VDC, 7 figure, behind the panel mount, wire leads
SR2-4017 115VAC, 7 figure, snap-in panel mount, wire leads
T2-4017 115VAC, 7 figure, PCB mount, pins
V8-4017 24VDC, 7 figure, V-base mount, wire leads
Description
Features Options
Specifications
Models DescriptionModels Description
The Model 40 is a low cost, non-reset totalizer, available with 6-7 figures (white on black background). A wide choice of operating voltages and
mountings make this product adaptable for most applications. The Model 40 is an ideal solution for applications that require low cost and product
reliability.
www.redingtoncounters.com
Model 40
22
Electromechanical Totalizer
1.17 [29.6]
0.69 [17.6]
1.18 [30.0]
0.71 [18.0]
1.63 [41.5] 0.04 [1.0]
0.08 [2.0]
0.59 [15.0]
0.20 [5.2]
M3 X 0.5 [12.7]
0.35 [8.8]
0.71 [18.0]
1.63 [41.5]
1.17 [29.6]
0.69 [17.6]
0.44 [11.2]
1.28 [32.4]
1.00 [25.4]
1.18 [30.0]
0.93 [23.7]
2X Ø.10 [Ø2.6] X 0.35 DEEP
1.01 [25.7]
0.37 [9.4]
0.39 [10.0]
1.32 [33.5]
1.06 [27.0]
0.08 [2.0]
1.56 [39.5]
PANEL CUTOUT: 1.20 [30.5] X 0.96 [24.4]
0.39 [10.0]
RECOMMENDED PANEL THICKNESS: 0.04 [1.0] to 0.08 [2.0]
2.24 [57.0]
1.83 [46.4]
0.21 [5.3]
0.71 [18.0] 0.75 [19.1]
1.77 [45.0] 0.06 [1.6]
2X 0.14 [3.6] X 0.22 [5.6] SLOT
1.18 [30.0]
0.71 [18.0]
1.63 [41.5]
0.50 [12.7]
1.17 [29.6]
0.69 [17.6]
0.20 [5.2]
Ø.08 [Ø2.0]
0.25 [6.4]
0.50 [12.7]
0.30 [7.7]
0.04 [1.0]
0.39 [10.0]
M3 X 0.5
0.59 [15]
[12.7]
1.77 [45.0]
0.06 [1.6]
1.63 [41.4]
1.13 [28.6]
1.18 [30.0]
0.71
[18.0]
1.86
[47.2]
2.38
[60.5]
4X 0.16 [4.0] X
Rear Mount
Behind the Panel Mount
Snap-In Panel Mount V-Base Mount
D-Base Mount
PCB Mount
Dimensions
Applications
Items dis-
pensed
Office equipment
Photocopi-
ers
Vending/Gaming machines
23
www.redingtoncounters.com
Model 44 Electromechanical Totalizer
A 6 figure, non-reset counter. Metal/plastic frame assembly assures ruggedness while one piece cover discourages tampering. Precision molded
internal gearing requires no lubrication for long, accurate count life. Applications include warranty verification, electronic game counting, coin box
tallies, or wherever small size, highly visible numerals, and solid construction are critical.
Voltages
7 figure
Lead length
Special connectors
Extended temperature range
Count x 2
Figures: 6 figures, white on black, 0.18’’ [4.6mm] high
Reset: None
Speed: 600 counts/minute
(min. 50ms - on, 50ms - off)
Voltages: 115VAC, 24VDC
(+/- 10%, but not to exceed 10 volts)
Power: 1.5 watts (nominal)
Mounting: Rear, behind the panel, base, or combination
Terminations: (2) #22 AWG 221°F [105°C] wire leads,
10’’ [254mm] long
Operating Life: Beyond 3 million counts
Temp. Range: +23°F to +104°F [-5°C to +40°C]
Approvals: UL Recognized, CE Compliant
Weight: 2.5 oz. [71g]
2-4416 115VAC, 6 figure, rear mount
8-4416 24VDC, 6 figure, rear mount
R2-4416 115VAC, 6 figure, behind the panel mount
R8-4416 24VDC, 6 figure, behind the panel mount
V2-4416 115VAC, 6 figure, base mount
V8-4416 24VDC, 6 figure, base mount
RV2-4416 115VAC, 6 figure, combination mount
RV8-4416 24VDC, 6 figure, combination mount
6543
21
2.18 [55.4]
0.78 [19.8]
1.36 [34.5]
0.41 [10.4]
1.11 [28.2]
6543
21
1.00 [25.4]
1.36 [34.5]
0.83 [21.1] 0.78 [19.8]
2.18 [55.4]
1.14 [29.0]
1.54 [39.1]
1.48 [37.6]
1.38 [35.1]
1.03 [26.2]
0.41 [10.4]
0.12 [3.1]
0.10 [2.5] 2.08 [52.8]
123456
6543
21 2.36 [60.0]
1.63 [41.4]
1.75 [44.5]
2.00 [50.8]
0.98 [24.9]
1.13 [28.7]
1.27 [32.3]
2.18 [55.4]
2.38 [60.5]
Rear Mount Behind the Panel Mount
Snap-In Panel Mount Base Mount
Mounting hole: For M3 screw Mounting holes: For M3 self tapping screw
Mounting holes: 0.14’’ [3.6mm] Dia.
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Small size
Highly visible numerals
Solid construction
Applications
Coin box tallies Electronic game countingWarranty verification
Model 48
24
Electromechanical
www.redingtoncounters.com
Totalizer
Applications
Control panels Gaming machines Vending machines Photocopiers
Coin-operated equipment
A compact, economical, 6 or 7 figure, non-reset, electromechanical counter designed for general purpose industrial and commercial counting
applications. It is designed for a variety of mounting methods as required by the application. Commonly used for coin-operating equipment,
photocopiers and vending machines.
Voltages
Lead lengths
5 figure
Figures: 6 or 7 figures, white on black, 0.17’’ [4.3mm] high
Reset: None
Speed: 1,000 counts/minute AC, (min. 30ms - on, 30ms - off)
1,200 counts/minute DC, (min. 25ms - on, 25ms - off)
Power: AC: 24VAC ~ 4 watts
115VAC ~ 3.5 watts
230VAC ~ 5 watts
DC: 12/24VDC ~ 2 watts
Mounting: Panel or base
Terminations: (2) #22 AWG 105°C wire leads, 12” [305mm] long
Operating Life: Beyond 10 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 3.5 oz. [99g]
P2-4816 115VAC, 6 figures, P panel mount
P8-4816 24VDC, 6 figures, P panel mount
R2-4816 115VAC, 6 figures, R panel mount
SR2-4816 115VAC, 6 figures, SR panel mount
SR8-4816 24VDC, 6 figures, SR panel mount
V1-4816 230VAC, 6 figures, V base mount
V2-4816 115VAC, 6 figures, V base mount
V3-4816 24VAC, 6 figures, V base mount
V8-4816 24VDC, 6 figures, V base mount
V9-4816 12VDC, 6 figures, V base mount
D8-4817 24VDC, 7 figures, D base mount
P2-4817 115VAC, 7 figures, P panel mount
P8-4817 24VDC, 7 figures, P panel mount
R8-4817 24VDC, 7 figures, R panel mount
SR8-4817 24VDC, 7 figures, SR panel mount
V2-4817 115VAC, 7 figures, V base mount
V8-4817 24VDC, 7 figures, V base mount
Description
Features Options
Specifications
Models DescriptionModels Description
6 or 7 figure
Compact
Non-reset
Variety of mounting options
* Items in bold are normally in factory stock.
25
www.redingtoncounters.com
Model 48 Electromechanical Totalizer
123456
2.25 [57.2]
0.99 [25.1]
2.36 [60.0]
1.86 [47.2]
1.13 [28.6]
1.63 [41.4] 0.20 [5.0]
P - Mount R - Mount
V - Mount
Mounting holes: For #5 flat head screw
Panel cutout: 1.72’’ x 1.05” [43.7 x 26.7mm]
Mounting holes: For #5 flat head screw
Panel cutout: 1.72’’ x 1.05” [43.7 x 26.7mm]
Mounting holes: 0.16’’ x 0.28’’ [4.1 x 7.1mm] slots
123456
1.44 [36.5]
1.80 [45.8] 2.07 [52.6]
Mounting holes: 0.15’’ [3.8] Dia. Panel cutout: 1.67’’ x 1.29” [42.4 x 32.8mm]
Recommended panel thickness: 0.04” to 0.08” [1.0 to 2.0mm]
D - Mount SR - Mount
Dimensions
123456
2.25 [57.2]
.99 [25.1]]
7
1.01 [25.7]
1.65 [41.9]
2.20 [55.9]
1.88 [47.8]
0.20
[5.1]
0.69
[17.5]
123456
1.39 [35.3] 1.80 [45.7]
1.80 [45.7]
0.14 [3.6]
2.25 [57.2]
1.80 [45.7]
1.80 [45.7]
123456
1.39 [35.3]
0.25 [6.3]
2.00 [50.8]
www.redingtoncounters.com
Model 49
26
Electromechanical Totalizer
Voltages
Extended temperatures
4 or 6 figure
Description
Features Options
Specifications
Models DescriptionModels Description
Economically priced 4 and 6 figure push-button reset, electromechanical counter designed for use where limited space is a factor and when
reliability is critical. Rugged operating mechanisms require no lubrication or maintenance. Compact size and minimum space requirements make
the Model 49 ideally suited for use in control panels, business machines, and test equipment.
Figures: 4 or 6 figures, white on black, 0.16’’ [4mm] high
Reset: Push-button
Speed: 600 counts/minute
(min. 50ms - on, 50ms - off)
Voltages: 115VAC, 24VDC
(+10% to - 15%)
Power: AC: 115VAC ~ 3 watts
DC: 24VDC ~ 2 watts
Mounting: Panel, base, or bail
Termination: (2) #22 AWG 105°C wire leads, 10’’ [254mm] long
Operating Life: Beyond 100 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CE Compliant
Weight: 4 oz. [113g] (4 fig.), 5 oz. [142g] (6 fig.)
B2-4904 115VAC, 4 figure, bail mount
B8-4904 24VDC, 4 figure, bail mount
D2-4904 115VAC, 4 figure, base mount
P2-4904 115VAC, 4 figure, panel mount
P8-4904 24VDC, 4 figure, panel mount
P9-4904 12VDC, 4 figure, panel mount
B2-4906 115VAC, 6 figure, bail mount
B8-4906 24VDC, 6 figure, bail mount
D2-4906 115VAC, 6 figure, base mount
P2-4906 115VAC, 6 figure, panel mount
P8-4906 24VDC, 6 figure, panel mount
P9-4906 12VDC, 6 figure, panel mount
Compact
No maintenance
Quick reset
* Items in bold are normally in factory stock.
27
www.redingtoncounters.com
Model 49 Electromechanical Totalizer
Applications
Control Panels Business Machines Medical devicesTest Equipment
Dimensions
2.55 [64.8]1.65 [41.9]
1.14 [28.9] 0.97 [24.6]
3
21 4
Panel cutout: 1.46’’ x 1.01” [37.1 x 25.7mm]
Bail Mount - 4 Figure
3
16
2.83 [71.9]
3.10 [78.7]
1.14 [29.0] 0.97 [24.6]
24
5
0.95 [24.1]
0.63 [16.0]
2.68 [68.1]
Mounting holes: 0.12’’ x 0.20’’ [3.1 x 5.1mm] slots
Base Mount - 6 Figure
3
16
2.55 [64.8]2.21 [56.1]
1.14 [28.9] 0.97 [24.6]
24
5
Bail Mount - 6 Figure
Panel cutout: 2.00’’ x 1.01” [50.8 x 25.7mm]
2.55 [64.8]1.80 [45.7]
1.80 [45.7] 0.97 [24.6]
1.40 [35.6]
3
21 4
Panel Mount - 4 Figure
Panel cutout: 1.46’’ x 1.01” [37.1 x 25.7mm]
Mounting holes: For #4 flat head screw
0.97 [24.6]
3
21 4
0.98 [24.9]
2.13 [54.1]
2.52 [64.0] 2.83 [71.9]
1.14 [29.0]
0.63 [16.0]
Base Mount - 4 Figure
Mounting holes: 0.12’’ x 0.20’’ [3.1 x 5.1mm] slots
Panel Mount - 6 Figure
Panel cutout: 2.00’’ x 1.01” [50.8 x 25.7mm]
Mounting holes: For #4 flat head screw
2.55 [64.8]2.21 [56.1]
1.80 [45.7] 0.97 [24.6]
1.40 [35.6] 3
21 6
45
www.redingtoncounters.com
28
Model 128 Electromechanical Totalizer
A general purpose, 4 figure electromechanical reset counter perfect for applications where long life, reliability, and accuracy are mandatory.
Several mounting alternatives and large, easy-to-read numbers are combined in a rugged housing.
Figures: 4 figures, white on black, 0.19’’ [5mm] high
Reset: Knob
Speed: 1,000 counts/minute
(min. 30ms - on, 30ms - off)
Voltage: 115 VAC
(+/-10%, but not to exceed 10 volts)
Power: 5 watts (nominal)
Voltages
Lead lengths
Terminations
Mounting: Base, panel, or behind the panel
Terminations: (2)#22 AWG 105°C wire leads, 8’’ [203mm] long
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 10 oz. [284g]
2-1284 115VAC, Base mount, knob reset
D2-1284 115VAC, D panel mount, knob reset
P2-1284 115VAC, P panel mount, knob reset
PR2-1284 115VAC, PR panel mount, knob reset
Base Mount
Mounting holes: 0.15’’ [3.8mm] Dia.
Rugged housing
Long life
Reliable
Accurate
Applications
Dimensions
Models Description
Models Description
Specifications
Features Options
Description
21 342.25 [57.2]1.94 [49.2]
1.13 [28.6]
1.71 [43.4]
1.81 [46.0]
2.30 [58.4]
1.64 [41.7]
2.49 [63.3]
Medical devices Office machinesProduction totals Control Panels
* Items in bold are normally in factory stock.
29
www.redingtoncounters.com
Model 300 Electromechanical Totalizer
An extremely long life, 6 figure, electromechanical counter available in panel mounting versions with manual push-button reset. High count
speeds, bold numbers, and contemporary design make this ideal in office, graphic arts, medical and computer applications.
Voltages
Lead lengths
Terminations
Figures: 6 figures, white on black, 0.15’’ [4mm] high
Reset: Push-button
Speed: 1,000 counts/minute AC, (min. 30ms - on, 30ms - off)
1,500 counts/minute DC, (min. 20ms - on, 20ms - off)
Voltages: 115VAC, 24VDC
(+/- 10%, but not to exceed 10 volts)
Power: 2.8 watts (nominal)
Mounting: Panel
Terminations: Solder terminals
Operating Life: Beyond 200 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 8 oz. [227g]
P2-3106 115VAC, P panel mount, manual reset
R2-3106 115VAC, R panel mount, manual reset
P8-3206 24VDC, P panel mount, manual reset
P9-3206 12VDC, P panel mount, manual reset
R8-3206 24VDC, R panel mount, manual reset
123456
2.37 [60.2]
1.98 [50.3]1.50 [38.1]
2.35 [59.7]
2.75 [69.9]
0.13 [3.3]
0.99 [25.2]
0.46 [11.7]
P - Mount R - Mount
Mounting holes: For #8 flat head screw
Panel cutout: 2.02’’ x 1.05” [51.3 x 26.7mm]
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
High count speed
Bold numbers
Contemporary design
123456
2.37 [60.2]
1.98 [50.3]
1.50
[38.1]
0.99
[25.2]
2.47 [62.7]
0.13 [3.3]
2.88 [73.2]
0.21[5.3]
Office equipmentGraphic arts Medical equipmentComputer applications Control panels
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 08
30
Mechanical Rotary Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
Linear measuring Machine revolutions Positioning
A 5 figure medium duty counter designed for applications where a rotary counter with a quick reset is desirable. When a 1’ circumference
measuring wheel is used with our standard counter, the counter will display feet and inches. Consult the factory if you have custom applications.
Counter will add and subtract
Push button reset
Versatile mounting
•1,000 revolutions per minute (100 feet per minute)
Double shaft
Wheel color
Figure color
Ratios
Mounting
Case color
98WF - Measuring Wheel - 12” circumference
Figures: 5 figures, 0.20” [5mm] high
Reset: Push-button
Rotation: Top going
Shaft Extension: 0.250“ diameter, left hand or right hand
Speed: 1,000 revolutions/minute (100 feet/minute)
Operation Life: Beyond 50 million
Temp. Range: -15°F to 140°F [-26°C to +60°C]
Weight: 10 oz. [283g]
11-0825 Left-hand, top-going, add & subtract 11-0845 Right-hand, top-going, add & subtract
4.18 [106.0]
4.73 [120.1]
2.05 [52.1]
0.42 [10.7]
2.53 [64.3]
0.21 [5.3]
0.30 [7.5]
0.12 [3.0]
Ø.25 [6.4]
1.15 [29.2]
1.22 [31.0]
0.50 [12.7]
1.62 [41.1]
1.10 [27.9]
Left - Hand Shaft
31
www.redingtoncounters.com
Model 14 Mechanical Small Case Totalizers
Four types of drives
Choice of five case configurations
Built-in non-overthrow mechanism on stroke counters
Built-in internal stops on stroke counters
5 Figure: white on black background
Mounting
Double shafts
Figure background and case colors
Sealed
The Model 14 is a compact, 5 figure, non-reset totalizer in a molded case with stainless steel shaft. Four types of drives are available and five
case configurations. An ideal solution when application requirements call for a low cost and compact totalizer.
Figures: 5 figures, white on black, 0.16” [4mm] high
Reset: Non-reset
Rotation: Top-coming or top-going
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.125” [3.2mm]
Speed: Stroke: 1,000 counts/minute
Revolution: 3,000 counts/minute
Direct: 15,000 counts/minute
Rotary Ratchet:
3,000 counts/minute rotary mode
1,500 counts/minute in oscillating mode
Weight: 0.5 oz. [14g]
Temp: -40°F to +160°F [-40°C to +71°C]
Operating Torque: Stroke; 0.8 to 2.0 in/oz
at 75°F Revolution; 0.15 in/oz
Direct; 0.15 in/oz
Rotary Ratchet; 0.3 to 1.0 in/oz
Case Types: Square base mount
Square panel mount
Square - no flange
Cylindrical base mount
Cylindrical panel mount
Drive Types:
Stroke: typical count stroke 39° to 48°
typical total stroke 50° to 52°
Revolution: adds or subtracts one(1) count per
revolution.
Direct: adds or subtracts ten (10) counts per
revolution
Rotary Ratchet: adds ten (10) counts per revolution
adds only one (1) count per 36° to 60°
oscillation.
11B-1415 lh, top coming, stroke, sq case, base mt
11B-1515 lh, top coming, rev. drive, sq case, base mt
11B-1615 lh, top coming, direct drive, sq case, base mt
11B-1715 lh, top coming, rotary rat., sq case, base mt
11B-1425 lh, top going, stroke, sq case, base mt
11B-1525 lh, top going, rev. drive, sq case, base mt
11B-1625 lh, top going, direct drive, sq case, base mt
11B-1725 lh, top going, rotary rat., sq case, base mt
11B-1435 rh, top coming, stroke, sq case, base mt
11B-1535 rh, top coming, rev. drive, sq case, base mt
11B-1635 rh, top coming, direct drive, sq case, base mt
11B-1735 rh, top coming, rotary rat., sq case, base mt
11B-1445 rh, top going, stroke, sq case, base mt
11B-1545 rh, top going, rev drive, sq case, base mt
11B-1645 rh, top going, direct drive, sq case, base mt
11B-1745 rh, top going, rotary rat., sq case, base mt
rat = ratchet
rev = revolution
sq = square
mt = mount
lh = left hand
rh = right hand
Similar products are also available in the following configurations:
Square case - panel mount change 11B to 11P
Square case - without flange change 11B to 11N
Cylindrical case - base mount change 11B to 21B
Cylindrical case - panel mount change 11B to 21P
Description
Features Options
Specifications
Models DescriptionModels Description
www.redingtoncounters.com
Model 14
32
Mechanical Small Case Totalizers
0.88 [22.4]
0.43
[10.9]
0.35
[8.9]
1.06
[26.9]
0.125 [3.2]
0.80
[20.3] 0.45
[11.4]
0.81 [20.6]
0.026 [0.7] X
0.020D [0.5]
SLOT
1.36
[34.5]
0.11
[
2.8
]
0.43
[10.9]
0.03
[0.8]
2X 0.13 [3.3]
0.88 [22.4]
0.43
[10.9]
0.35
[8.9]
1.06
[26.9]
0.08
[2.0] 0.62
[15.8]
1.36
[34.5]
0.125
[3.2]
0.45
[11.4]
2x 0.13 [3.3]
0.02
[0.5] 0.43
[10.9]
0.81 [20.6]
0.11 [2.8]
0.80
[20.3]
0.026 [0.7] x
0.020D [0.5]
SLOT
0.80
[20.3]
0.88 [22.4] 0.35
[8.9]
0.08 [2.0] 0.62 [15.8]
0.125
[3.2]
0.45
[11.4]
0.80 [20.3]
0.40
[10.2]
0.03
[7.6] 0.43
[10.9]
0.026 [0.7] X
0.020D [0.5] SLOT
0.88 [22.4]
0.41
[10.9]
0.35
[8.9]
0.08
[2.0] 0.62 [15.8] 2x 0.13 [3.3]
0.125
[3.2]
0.80
[20.3] 0.38
[9.7]
0.84 [21.3]
0.41
[10.4] 0.10
[2.5]
1.26
[32.0]
0.63
[16.0]
0.026 [0.7] X
0.020D [0.5] SLOT
0.129
[3.3]
0.095
[2.4]
0.22 [5.6]
0.437 [11.1] 0.65
[16.5]
0.25
[6.4]
0.31
[7.9]
0.057 [1.5]
0.129
[3.3]
0.095
[2.4]
0.437
[11.1]
0.22 [5.6]
1.0
[25.4]
1.12
[28.5]
0.25
[6.4]
0.31 [7.9]
0.057
[1.5]
0.94
[23.9]
0.88 [22.4]
0.41
[10.4]
0.35
[8.9]
0.08 [2.0] 0.62 [15.8] 2X 0.13 [3.3]
0.125
[3.2]
1.27
[32.3]
0.38
[9.7]
0.43
[10.9]
0.80
[20.3]
0.026 [0.7] X
0.020D [0.5] SLOT
0.10 [2.5]
0.07 [1.8]
Square Case Base Mount Square Case Without Flange
Square Case Panel Mount Cylindrical Case Base Mount
Short Lever (10006-028S) Standard Lever (10006-027S)
Cylindrical Case Panel Mount
Applications
Dimensions
Vending machinesCircuit breakers Gaming machines Business and office equipment
33
www.redingtoncounters.com
Model 18 Mechanical Tally Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A 4 figure, hand-held or desk mounted reset counter with push-button actuator. Case is chrome plated steel. Hand-held model comes with thumb ring
for ease of use. Single desk mounted style has plastic base with mounting holes. Multiple desk units, from 2 to 10, mounted on a single base with a
common reset. These tallys are a convenient way to count inventory, attendance, traffic, blood cells, or food portions.
Figures: 4 figures, white on black, 0.16’’ [4mm] high
Reset: Knob
Operating Life: Beyond 5 million counts
12-1804 Hand Tally with finger ring
13-1804 Desk Tally with mouning base
3-1804-2 Versa Tally: 2 units, common reset and base
3-1804-3 Versa Tally: 3 units, common reset and base
3-1804-4 Versa Tally: 4 units, common reset and base
3-1804-5 Versa Tally: 5 units, common reset and base
Model 12-1804
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 3.5 oz. [99g]
3-1804-6 Versa Tally: 6 units, common reset and base
3-1804-7 Versa Tally: 7 units, common reset and base
3-1804-8 Versa Tally: 8 units, common reset and base
3-1804-9 Versa Tally: 9 units, common reset and base
3-1804-10 Versa Tally: 10 units, common reset and base
1.17 [29.7]
1.64 [41.7]
1.81 [46.0]
1
3
24
2.29 [58.2]
12 34
12 3
4
3 HOLES 0.138 [3.51] DIA.
ON A 1.965 [49.9] B.C.
EQUALLY SPACED
2.62 [66.5]
1.81 [46]
Ø 2.24 [57]
1.17 [29.7]
Model 13-1804
Chrome plated steel housing
Long life
Multiple units
Food portions
Inventory Attendance Traffic Blood cells
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 19
34
Mechanical Modular Tally Counter
Description
Features Options
Specifications
Models Description
Dimensions
Applications
The Redington “Victor” counters are manually operated mechanical totalizers ideal for use when you need to count more than one item at the
same time. Models are available from a single counter to a maximum of 20 units (4 wide X 5 high). All modules have 4-figure counters and a
common rotary reset for the entire row. Each unit can be easily labeled using removable paper tabs. Applications include Lab Counters, Traffic
Surveys, Inventory Control, Inspection Tallies, QC Counters, Bus Counters and Point-of-Sale Records.
Figures: 4 figures, white on black, 0.12’’ [3mm] high
Reset: Knob
11-1904 Modular Tally, single unit
21-1904 Modular Tally, 2 units wide x 1 unit high
31-1904 Modular Tally, 3 units wide x 1 unit high
41-1904 Modular Tally, 4 units wide x 1 unit high
12-1904 Modular Tally, 1 unit wide x 2 units high
22-1904 Modular Tally, 2 units wide x 2 units high
32-1904 Modular Tally, 3 units wide x 2 units high
42-1904 Modular Tally, 4 units wide x 2 units high
13-1904 Modular Tally, 1 unit wide x 3 units high
23-1904 Modular Tally, 2 units wide x 3 units high
33-1904 Modular Tally, 3 units wide x 3 units high
43-1904 Modular Tally, 4 units wide x 3 units high
Weight: ~3.0oz. [85g] per unit
Paper tabs for labeling
Common reset for each row
Positive action pushbutton
Lubrication not required
Quick, simple to operate and accurate
Multiple units - up to 20 counters
Dimensions for a single unit are
shown to the right. To calculate the
approximate size of an assembled
unit, add 1.5” [37] to the width for
each additional unit in a row, and add
2.6” [66] to the depth and 1.5” [37] to
the height, for each additional row.
14-1904 Modular Tally, 1 unit wide x 4 units high
24-1904 Modular Tally, 2 units wide x 4 units high
34-1904 Modular Tally, 3 units wide x 4 units high
44-1904 Modular Tally, 4 units wide x 4 units high
15-1904 Modular Tally, 1 unit wide x 5 units high
25-1904 Modular Tally, 2 units wide x 5 units high
35-1904 Modular Tally, 3 units wide x 5 units high
45-1904 Modular Tally, 4 units wide x 5 units high
Models Description
Side View Top View
Front View
1.7 [43]
2.9 [74] REF
1.6 [40]
2.6 [66]
Food portionsInventory Attendance Traffic Blood cells
35
www.redingtoncounters.com
Model 20 Mechanical Stroke Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A highly versatile, 5 figure stroke counter. Numbers are large and distinctive for easy viewing even when above or below eye level. Ruggedly built
for years of trouble-free use. An excellent choice for counting parts produced.
Figures: 5 figures, white on black, 0.19’’ [5mm] high
Reset: Knob
Speed: 1,000 counts/minute
Rotation: Top-coming or top-going
Count Stroke: 49° Min. - 60° Max.
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.125’’ [3.2mm]
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 5 oz. [142g]
Non-reset
Large reset knob
Right or left-hand shaft extension
10007-010S - additional lever and spring
1-2015 Left-hand, top-coming, standard reset knob
1-2025 Left-hand, top-going, standard reset knob
1-2035 Right-hand, top-coming, standard reset knob
1-2045 Right-hand, top-going, standard reset knob
1.44 [36.5]
1.36 [34.5]
0.99 [25.2]
0.45 [11.6]
2.16 [54.9]
3
21 45
3.21 [81.4]
0.83 [21.1]
1.21 [30.6]
Ø.12 [3.2]
Right-Hand Shaft
Mounting holes: 0.13’’ x 0.38’’ [3.3 x 9.7mm] slots
Durable
Large figures
Reliable
Machine cycles Secondary machinesPunch press
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 22
36
Mechanical Rotary Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
2.16 [54.9]
3.13 [79.5]
1.44 [36.5]
3
21 45
1.38 [35.1]
0.99 [25.2]
0.83 [21.1]
1.20 [30.5]
0.47 [12.1]
Ø
.12 [
Ø
3.2]
A compact, 5 figure, rotary counter, indicating 10 counts/revolution. Design and compact size make it ideally suited for office and test equipment,
coin counting and other direct reading instruments.
Figures: 5 figures, white on black, 0.19’’ [5mm] high
Reset: Knob
Speed: 1,000 revolutions/minute
Rotation: Top-coming or top-going
Shaft Extension: Right-hand or left-hand
Large reset knob
Special shaft
Shaft Diameter: 0.125’’ [3.2mm]
Ratio: 10 counts/revolution
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 4 oz. [113g]
1-2215 Left-hand, top-coming, add only
1-2225 Left-hand, top-going, add only
1-2235 Right-hand, top-coming, add only
1-2245 Right-hand, top-going, add only
7-2215 Left-hand, top-coming, add and subtract
7-2225 Left-hand, top-going, add and subtract
7-2235 Right-hand, top-coming, add and subtract
7-2245 Right-hand, top-going, add and subtract
1-2315 Left-hand, top-coming, add and subtract, non-reset
1-2325 Left-hand, top-going, add and subtract, non-reset
Mounting holes: 0.13’’ x 0.38’’ [3.3 x 9.7] slots
Right-Hand Shaft
Compact size
5 figures
Long life
Production equipment PositioningSpooling
* Items in bold are normally in factory stock.
37
www.redingtoncounters.com
Model 27 Mechanical Stroke Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A heavy-duty, 5 figure, internal reset, stroke counter. Available in either right-hand or left-hand shaft extension.
Figures: 5 figures, white on black, 0.31’’ [8mm] high
Reset: Internal - lift cover, reset wheels
Speed: 750 counts/minute
Rotation: Top-coming
Count Stroke: 36° Min. - 45° Max.
Shaft Extension: Right-hand or left-hand
Operating Life: Beyond 200 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 24 oz. [680g]
1-2715 Left-hand, top-coming 1-2735 Right-hand, top-coming
3
21 45
3.42
[86.9]
2.28
[57.9]
1.14
[29.0]
1.05
[36.7]
1.75 [44.5]
2.02 [51.3]
2.83
[71.9]
4.08 [103.6]
4.94 [125.5]
Right-Hand Shaft
Mounting holes: 0.19’’ [4.8mm] Dia.
Right or left-hand shaft extension
1022-006S - additional spring
Heavy-duty
Internal reset
Punch press Machine cyclesSecondary Machines
* Items in bold are normally in factory stock.
Model 28
38
Mechanical
www.redingtoncounters.com
Stroke Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A 5 figure, rugged stroke counter, with right-hand shaft extension, operating lever and attached spring. Rated at 600 counts per minute, this heavy-
duty model is well suited for most industrial applications.
Lever modifications
1022-006S - additional spring
Figures: 5 figures, white on black, 0.27’’ [7mm] high
Reset: Knob, internal, or lock and key
Speed: 600 counts/minute
Rotation: Top-coming
Count Stroke: 36° Min. - 45° Max.
Shaft Extension: Right-hand
Operating Life: Beyond 200 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 20 oz. [567g]
3-2835 Right-hand, top-coming, internal reset
4-2835 Right-hand, top-coming, knob reset
5-2835 Right-hand, top-coming, lock and key reset
1 2 345
2.13 [54.1]
3.19 [80.9]
2.83 [71.8]
4.45 [113.0]
1.55 [39.4]
0.65 [16.4]
Right - Hand Shaft
Mounting holes: 0.18’’ [4.6mm] Dia.
Heavy-duty
600 CPM
5 Figures
Punch press ShearsMachine cycles
* Items in bold are normally in factory stock.
39
www.redingtoncounters.com
Model 29 Mechanical Stroke Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A 6 figure, general purpose heavy duty industrial stroke counter designed for high count rates and continuous operation even under the most adverse
operating conditions. Corrosion resistant material and finishes. Large, easy-to-read numbers.
Non-reset
Double shaft extensions
Special mounting bases
Weatherized versions
1022-006S - additional spring
1255-004S - additional lever
Figures: 6 figures, white on black, 0.30’’ [7.6mm] high
Reset: Knob or lock and key
Speed: 1,000 counts/minute
Rotation: Top-coming or top-going
Count Stroke: 40° Min. - 70° Max.
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.25’’ [6.4mm]
Operating Life: Beyond 100 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 18 oz. [510g]
1-2916 Left-hand, top-coming, standard reset knob
1-2926 Left-hand, top-going, standard reset knob
1-2936 Right-hand, top-coming, standard reset knob
1-2946 Right-hand, top-going, standard reset knob
2-2936 Right-hand, top-coming, lock and key reset
V1-2936 Right-hand, top-coming, standard reset knob, V-base
3
21 456
4.38 [111.3]
5.57 [141.5]
3.91 [99.3]
1.13 [28.6] 1.81 [46.0]
0.69 [17.5]
2.15 [54.6]
2.62 [66.5]
1.97
[50.0]
2.86 [72.6]
1.23 [31.1]
3.91 [99.3]
3.25 [82.6]
Right - Hand Shaft
Mounting holes: 0.22’’ [5.6mm] Dia.
V - Mount
Heavy duty
High count rates
Corrosion resistant
Punch presses Cement trucksShears
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 29
40
Mechanical Rotary Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A 6 figure, general purpose, industrial rotary counter designed for use on equipment where environmental conditions are far from ideal. Various count
ratios make it suitable for winding equipment, measuring devices and direct reading instruments.
Non-reset
Subtractive
Double shaft extensions
Special mounting bases
Weatherized versions
98WF - Measuring Wheel - 12” circumference
1.81 [46.0]
0.69 [17.5]
2.15 [54.6]
Ø.25 [6.4]
3
21 456
4.38 [111.1]
5.57 [141.5]
3.91 [99.3]
1.13 [28.6]
Right - Hand Shaft
Mounting holes: 0.22’’ [5.6mm] Dia.
Figures: 6 figures, white on black, 0.30’’ [7.6mm] high
Reset: Knob or lock and key
Speed: 2,500 counts/minute or revolutions/minute,
whichever is lower
Rotation: Top-coming or top-going, to add.
Will not subtract if rotation is reversed
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.25’’ [6.4mm]
Ratio: 1 count/revolution or 10 counts/revolution
Operating Life: Beyond 100 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 18 oz. [510g]
11-2916 Left-hand, top-coming, 10 counts/revolution
11-2936 Right-hand, top-coming, 10 counts/revolution
21-2916 Left-hand, top-coming, 1 count/revolution
21-2926 Left-hand, top-going, 1 count/revolution
21-2936 Right-hand, top-coming, 1 count/revolution
21-2946 Right-hand, top-going, 1 count/revolution
22-2936 Right-hand, top-coming, 1 count/revolution,
lock & key reset,
Winding equipment
Heavy duty
High count rates
Corrosion resistant
Spooling Positioning
41
www.redingtoncounters.com
Model 41 Mechanical Register
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
Pumps and Flow Meters
The Model 41 is a 3-figure or 4-figure mechanical register and is used to display gallons or liters output from a dispenser or pump. The
large figure display can be reset with the rotary reset shaft. A smaller, non-reset, mechanical totalizer is also included to record total
product dispensed.
Large easy to read figures
Time tested, reliable and durable
Wide operating temperature range
All non-corrosive parts
Spring loaded totalizer is pre-settable
No lubrication required
Gallons or liters
Reset shaft configuration
Reset shaft: right hand, left hand, or both
Figures:
Main Display: 3 or 4 figures, white on black, 0.65" [16.5mm] high
Totalizer: 0.19” [5mm] white on black
Reset: Rotary reset. Reset knob supplied by customer
Reset Shaft: 0.25” [6.4mm] diameter
Speed: 40 gallons per/minute, 400 liters per/minute
Operation Life: 1 million gallons, 10 million liters
Temp. Range: -40°F to +150°F [-40°C to +65°C]
Weight: 3-figure - 9oz [255g], 4-figure - 11oz [312g]
1-4103 3-figures, gallon display
2-4104 4-figures, gallon display
2-4103 3-figures, liter display
3-4104 4-figures, liter display
3-Figure 4-FigureSide View
www.redingtoncounters.com
Model 46
42
Mechanical Stroke Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
These 5 figure stroke counters are especially designed for limited space and high count life applications. The advanced drive system translates into
exceptionally high operating speeds, extended operating life, for fast and accurate readings. Ideal for copiers, printing presses, cut-off machines, and
piece-part counting applications. Also available with a thumb lever for use as a tally counter.
Special levers
10011-001S - additional spring
10007-009S - lever and spring
Figures: 5 figures, white on black, 0.19’’ [5mm] high
Reset: Standard or large knob, non-reset
Speed: 500 counts/minute
Rotation: Top-coming or top-going
Count Stroke: 40° Min. - 45° Max.
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.156’’ [4.0mm]
Operating Life: Beyond 5 million counts
Temp. Range: -15°F to +140°F [-25°C to +60°C]
Weight: 2 oz. [57g]
1-4615 Left-hand, top-coming, standard reset knob
1-4625 Left-hand, top-going, standard reset knob
1-4635 Right-hand, top-coming, standard reset knob
1-4645 Right-hand, top-going, standard reset knob
1-4635T Right-hand, top-coming, std. reset knob, with thumb lever
2-4615 Left-hand, top-coming, large reset knob
2-4625 Left-hand, top-going, large reset knob
2-4635 Right-hand, top-coming, large reset knob
2-4645 Right-hand, top-going, large reset knob
5-4645 Right-hand, top-going, non-reset
3
21 45
0.81 [20.6]
1.52 [38.6]
2.53 [64.3]
1.20 [30.5] 1.44 [36.6]
1.28 [32.5]
0.96 [24.4]
Right - Hand Shaft
Mounting holes: 0.13’’ x 0.24’’ [3.3 x 6.1mm] slots
Copiers
Compact size
Reliability
Low cost
Farm equipment Piece-part counting Cut-off machinesPrinting presses
With Thumb LeverWith Lever & Spring
* Items in bold are normally in factory stock.
43
www.redingtoncounters.com
Model 750 Mechanical Revolution Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
These rugged revolution counters are completely sealed, tamper resistant, and maintenance-free. They can be mounted on a rotating shaft or wheel.
Adds in either direction, and records revolutions, miles, kilometers, or acres. They are used on material handling equipment, farm machinery, rapid
transit vehicles, street sweepers, golf carts, and construction equipment.
Figures: 7 figures, 0.19’’ [5mm] high
Temp. Range: -50°F to +180°F [-45°C to +82°C]
Weight: 1.5 Lbs. [0.7kg]
Face plate
Custom calibrations
750-0002 Reading x 10 = Total Revolutions (Revolutions)
750-0007 (9.5L - 15) x 15’ (Acres)
750-0016 364 Revolutions per Acre (Acres)
750-0114 Reading x 100 = Revolutions (Revolutions)
750-0156 798 Revolutions per Acre (Acres)
1234567
4.33 [110.0]
4.71 [119.6]
0.26 [6.6]
1.24 [31.5]
2.11 [53.6]
1/2-20 UNF X 0.53 LONG
Hubodometer
Consult factory for a counter to meet your specific needs.
Sealed
Tamper resistant
Bi-directional
Farm machineryRapid transit vehicles Construction equipmentGolf carts
www.redingtoncounters.com
Model PCU
44
Mechanical Stroke Counter
Description
Specifications
Models DescriptionModels Description
Dimensions
Applications
This 3 or 4 figure stroke counter with operating lever, spring assembly and reset knob, requires minimal space for mounting plus offers a high count
rate and long life. The Model PCU can be reset during operation without damage. All PCU’s are designed to minimize internal contamination, making
them an excellent choice for outdoor use.
Non-reset
Large reset knob
Figures: 3 or 4 figures, white on black, 0.19’’ [5mm] high
Reset: Knob
Speed: 600 counts/minute
Rotation: Top-coming or top-going
Count Stroke: 40° Min. - 45° Max.
Shaft Extension: Right-hand or left-hand
Shaft Diameter: 0.156’’ [4mm]
Operating Life: Beyond 50 million counts
Temp. Range: -15°F to +140°F [-26°C to +60°C]
Weight: 2 oz. [57g]
1-PCU-13 Left-hand, top-coming, 3 figure
1-PCU-33 Right-hand, top-coming, 3 figure
1-PCU-33T Right-hand, top-coming, 3 figure, with thumb lever
1-PCU-43 Right-hand, top-going, 3 figure
1-PCU-14 Left-hand, top-coming, 4 figure
1-PCU-24 Left-hand, top-going, 4 figure
1-PCU-34 Right-hand, top-coming, 4 figure
1-PCU-44 Right-hand, top-going, 4 figure
Shears
Features Options
3 or 4 figure
Compact size
Suitable for outdoor use
1-PCU-141-PCU-13
Secondary Machines Farm Machinery
1.44 [36.6]
0.67 [16.9]
1.38 [35.2]
2.39 [60.7]
1.28 [32.5]
0.96 [24.4] 1.20 [30.4]
12 3
0.85 [21.6]
4X Ø0.13 [Ø3.3]
1.44 [36.6]
1.28 [32.5]
0.96 [24.4]
0.85 [21.6]
0.74 [18.7]
1.45 [36.9]
2.46 [62.5]
1.20 [30.4]
1234
4X Ø0.13 [Ø3.3]
45
www.redingtoncounters.com
Model 58 Electromechanical Predetermining Counter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
Designed for use in a wide variety of production, batching and packaging applications. These 4 or 6 figure electromechanical predetermining counters
count down from a preset number and activate a SPDT switch. Convenient preset controls and built-in manual reset with guard are standard. A surge
absorbing circuit protects against damage due to voltage spikes. Heavy duty bail mount secures counter in place.
Figures: 4 or 6 figures, white on black, 0.16’’ [4mm] high
Reset: Manual, or electric reset (min. 100ms - on, 1min - off)
Speed: 600 counts/minute (min. 50ms - on, 50ms - off)
Voltages: 115VAC, 24VDC
(+/-10%, but not to exceed 10 volts)
Power: 5.5 watts count, 20 watts reset (nominal)
Mounting: Bail
Voltages
Termination: Screw type
Operating Life: Beyond 100 million counts
Temp. Range: -15°F to +140°F [-26°C to + 60°C]
Output Switch: SPDT 5 Amp. @ 250 VAC resistive
Output Duration: Until reset
Approvals: UL Recognized, CE Compliant
Weight: 10 oz. [284g]
B2-5804 115VAC, 4 figure, manual reset
B2-5804/E2 115VAC, 4 figure, 115VAC electric reset
B8-5804 24VDC, 4 figure, manual reset
B8-5804/E8 24VDC, 4 figure, 24VDC electric reset
B2-5806 115VAC, 6 figure, manual reset
B2-5806/E2 115VAC, 6 figure, 115VAC electric reset
B8-5806 24VDC, 6 figure, manual reset
B8-5806/E2 24VDC, 6 figure, 115VAC electric reset
1 2 3 4
2.36 [60.0] 2.83 [71.8]0.28 [7.0] 0.67 [17.0]
2.36 [60.0]
Bail Mount
Panel cutout: 2.17’’ x 2.17’’ [55.1 x 55.1]
4 or 6 figures
Heavy duty mount
SPDT switch
ProductionBatchingPackaging
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 33
46
Electronic LCD Hour Meter
Description
Features Options
Specifications
The Redington Model 33 line of LCD hour meters provides a large display, 7mm high figures, in the industry size housings. The hour meters
are available in a variety of mountings: 2-hole rectangular, 3-hole round, flush-round and flush-rectangular. Voltage operating ranges are 10-
277 VDC AND 20-277VAC 50/60Hz. All models are totally sealed from moisture and dirt and conform to NEMA 4 & 4X specifications when
mounted with the optional gasket. Their rugged construction makes them ideal replacements for current hour meters. Units have polarized
LCD for high visibility in sunlight.
AC or DC voltage input in the same unit
Totally sealed from moisture and dirt
Run indicator-blinking decimal point
Always on display
Compact depth
AC Voltage input is not frequency sensitive
Clip retainer mount or screws (supplied)
Custom logos and bezels
Terminations
Remote reset - dry contact with 6” wire leads
Gaskets
5003-002S gasket for 2-hole mount
5003-003S gasket for flush-rectangular mount
5003-004S gasket for flush-round mount
5003-005S gasket for 3-hole round mount
Display: LCD with large 0.28” [7mm] high figures,
black on light background
Run Indicator: Blinking decimal point
Quartz Accuracy: 0.02% over entire voltage & temperature
range
Records & Displays: 6 digit (99999.9)
Inputs: 10 to 277VDC AND 20-277VAC-50/60Hz
Vih* 20VAC or 10VDC minimum
Vil* 3VAC or 3VDC maximum
Battery Life: 7+ years
Shock: 44 to 55g’s, SAE J1378
Vibration: 20 g @ 10 to 80 Hz, SAE J1378
Humidity: 95% SAE J1378
Operating Temperature: -40°F to +185°F [-40°C to +85°C]
Sealing: Totally sealed, panel gaskets-NEMA 4 & 4X
Agency Approvals: CE compliant
UL/cUL recognized (file# ELIY2.E36690)
Termination: 0.250” [6.4mm] spades
Reset: Optional - dry contact with 6” wire leads
Case Material: Polymer (black)
Weight: 1oz [28g]
Protection Against: Alternator load dump: 150V
EMI(Electromagnetic Interference): +400V
@ 500Hz inductive switching and reverse
polarity
3311-0000 2-Hole Rect., 10-277 VDC AND 20-277VAC
3311-1000 3-Hole Round, 10-277 VDC AND 20-277VAC
3311-2000 Flush Rect., 10-277 VDC AND 20-277VAC
3311-3000 Flush-Round, 10-277 VDC AND 20-277VAC
* Vih is the input high voltage. This is specified as the minimum input voltage that the Model 33 will recognize as a high level.
Vil is the input low voltage. This is specified as the maximum input voltage that the Model 33 will recognize as a low level.
All parts are normally in factory stock.
3311-0010 2-Hole Rect., 10-277 VDC AND 20-277VAC, remote reset
3311-1010 3-Hole Round, 10-277 VDC AND 20-277VAC, remote reset
3311-2010 Flush Rect., 10-277 VDC AND 20-277VAC, remote reset
3311-3010 Flush-Round, 10-277 VDC AND 20-277VAC, remote reset
Models Description Models Description
Note: When interfacing the Model 33 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
47
www.redingtoncounters.com
Model 33 Electronic LCD Hour Meter
Dimensions
Applications
0.28 [7.0]
2.04 [51.9]
1.75 [44.4]
Ø.15 [Ø3.8]
1.10 [27.9]
0.44 [11.2]
0.34 [8.7]
0.93 [23.5]
0.25 [6.3]
1.43 [36.2]
0.99 [25.1]
0.06 [1.5]
0.06 [1.5] 1.41 [35.8]
0.89 [22.6]
0.28 [7.0]
0.12 [3.0]
0.25 [6.3]
0.99 [25.1]
1.43 [36.2]
Ø2.86 [72.6] 0.93 [23.5]
0.34 [8.7]
0.44 [11.2]
3X Ø.13 [Ø3.2] EQUALLY SPACED
ON A 2.53[89.7] B.C.
0.28 [7.0]
1.60 [40.6]
1.10 [27.9]
0.44 [11.2]
0.34 [8.7]
0.93 [23.5]
0.06 [1.5]
0.06 [1.5]
1.43 [36.2]
0.99 [25.1]
0.25 [6.3]
1.41 [35.8]
0.89 [22.6]
0.25 [6.3]
1.43 [36.2]
0.99 [25.1]
0.12 [3.0]
0.34 [8.7]
0.93 [23.5]
0.44 [11.2]
Ø2.27 [57.7]
0.28 [7.0]
2-Hole 3-Hole Round
Flush-Round Flush-Rectangular
Agricultural Equipment
Compressors
Medical Devices
Marine ApplicationsConstruction Equipment Generators
Utility Vehicles
Pressure Washers Sweepers
Boom LiftsTest Equipment
Office Equipment
In-front panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Behind panel cutout: 1.42 X 0.90 [22.9 x 36.1] Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Maximum panel thickness: 0.15 [3.8]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0]
Maximum panel thickness: 0.15 [3.8]
www.redingtoncounters.com
Model 51
48
Electronic LCD Hour Meter/Maintenance Meter
Options
The Redington Model 51 line of 5 figure LCD meters provides a large display in the industry size package. A choice of mountings, Round, 2 Hole
Dual, Mini Rectangular or Surface Mount. A custom microprocessor, capable of being programmed to create an almost infinite matrix of models is
ideally suited for OEM applications. Available in 3 inputs, DC, AC or Inductive. Maintenance Meters are offered with a “Redi-Alert” to alert users
when service is due. Not only does the display flash to get attention, but it displays specific maintenance service needs to be done. Units have
Polarized LCD for high visibility in sunlight. Servicing equipment on time is critical to efficient operation and long equipment life. That is why you
should consider Redington’s “Redi-Alert” meters. Redi- Alert offers two independent alarms (both fully programmable) to alert users when
service is due. Alarms are fully automatic; coming on and shutting off at times determined by the OEM.
Totally sealed from moisture and dirt
Fits in existing panel openings
“Redi-Alert” for preventive maintenance
Icons for specific maintenance needs
Tachometer/Hour Meter versions
Automatic rollover
Hour glass symbol appears & flashes on/off to indicate
running time
Various voltage inputs
Short depth
Always on display
Various voltage inputs
Alarm outputs: audible or visual (external voltagerequired)
Custom logos & bezels
Terminations: stud, wire, screw, or blade
Alternator and filtered versions
Key Kancel (alarm reset via external key or wand)
Display: Large 0.20” [5mm] LCD, black on light
background
Records & Displays: 5 digits (9999.9)
Resolution: 0.1 hours
Quartz Accuracy: 0.02% over entire voltage & temp. range
Inputs: 8-32 VDC, 32-277 VAC-50/60HZ
Operating Temperature: -40°F to +160°F [-40°C to +71°C]
Battery Life: 15 years
Current Consumption: 1 mA (for multi-range voltages 1 mA
applies to lower voltage)
Approvals: AC-UL/cUL Recognized, CE Compliant
Protection Against: Transient voltage, inductive switching,
reverse polarity, frequency variations
Alternator Load Dump: 150 V
Shock: SAE J1378 55g
Vibration: SAE J1378 20g
Humidity: SAE J1378 95% RH
Termination: Panel mount standard terminals, 0.250
male blade (s), surface mount- wire lead
Case Material: ABS, black, 100% epoxy filled
Weight: 1 oz. [28g]
DC Models
5120-1000 Panel Mount, Round, 8-32 VDC, Hours & 1/10’s
5120-1100 Panel Mount, Mini, 8-32 VDC, Hours & 1/10’s
5120-1200 Panel Mount, 2 Hole, 8-32 VDC, Hours & 1/10’s
AC Models
5120-2000 Panel Mount, Round, 32-277VAC, 50/60 Hz, Hours & 1/10’s
5120-2100 Panel Mount, Mini, 32-277 VAC, 50/60 Hz, Hours & 1/10’s
5120-2200 Panel Mount, 2 Hole, 32-277 VAC, 50/60 Hz, Hours & 1/10’s
Models DescriptionModels Description
Specifications
Features
Description
Inductive Models
5120-0000 Panel Mount, Round, Inductive, Hours
5120-0100 Panel Mount, Mini, Inductive, Hours
5120-0200 Panel Mount, 2 Hole, Inductive, Hours
5140-0000 Panel Mount, Round, Inductive, Hours & 1:1Tach
5140-0100 Panel Mount, Mini, Inductive, Hours & 1:1Tach.
5140-0200 Panel Mount, 2 Hole, Inductive, Hours & 1:1Tach.
5120-0310 Surface Mount, Inductive, Hours
5140-0311 Surface Mount, Inductive, Hours w/1:1Tach.
Change oil Alert @ 25hr./2 hr. flash Lube Alert @
25hr./2 hr. flash
5140-0312 Surface Mount, Inductive, Hours w/1:1Tach.
Change oil Alert @ 100hr./4 hr. flash Lube Alert @
25 1hr./2 hr. flash
* Items in bold are normally in factory stock.
49
www.redingtoncounters.com
Model 51 Electronic LCD Hour Meter/Maintenance Meter
2.12 [53.8]
1.39 [35.3]
R0.20 [R5.1]
0.50 [12.7]
22 Gauge
1.75 [44.5]
1.08 [27.4]
0.75 [19.1]
0.94 [23.9]
0.10 [2.5]
R0.20 [R5.1]
1.40 [35.6]
1.75 [44.5]
0.94 [23.9]
0.75 [19.1]
0.10 [2.6]
0.15 [3.9]
0.92 [23.4]1.08 [27.4]
R0.10 [R2.5]
Ø0.15 [Ø3.8]
2 Hole Dual Mount Round
Surface Mount Mini Rectangular
Above panel cutout 1.46 x 0.95 [37.1 x 24.1] opening
Behind panel cutout 1.41 x 0.93 [35.8 x 23.6] opening
Spring clip retainer, Fast installation
Panel cutout 2.0 [50.8] diameter
Mounting holes are 1 1/2” [38.1] spacing
Hole Diameter is 1/8” [3.2]
Compact Bezel Design, Spring clip retainer, Fast
installation, Panel cutout 1.46 x 0.95 [37.1 x 24.1] opening.
Alarm Specifications
Alarms programmable for your applications
ALARM # 1
Programmable for a “first time” (break in service) or a normal recurring
service interval.
ALARM # 2
Same as alarm # 1, but without the “first time” interval.
ALARM/ FLASH DURATION
OEM’s specify the service interval and flash duration for each alarm.
Flash duration is the amount of time in hours that the specified icon
flashes before and after the service interval.
ALARM RESET
The standard alarm alert is fully automatic with no operator interface
necessary. The alarm simply flashes the specified icon for the duration
called out by the OEM. Controlled reset options are available for a higher
level of security. Contact factory for additional information.
MAINTENANCE METER ALARM SPECIFICATIONS
ALARM #1
1st time service interval range Normal service interval range:
(2 to 99 hrs. occurs only once) 2 to 999 hrs. (Recurring)
Flash duration: 1 to 99 hrs. Available icons: CHG OIL, LUBE,
(Time flashing before & after CHG MUFF, SVC-AIR FILTER,
service interval) SVC-Lower left/right side of display
ALARM # 2
Normal service interval range: Flash duration: 1 to 99 hrs.
2 to 999 hrs. (Recurring) (Time flashing before & after
service interval)
Available icons: CHG OIL, LUBE,
CHG MUFF, SVC-AIR FILTER,
SVC-Lower left/right side of display
Alarms flash specified icon 4 seconds then flash hour 4 seconds through-
out alarm duration.
Dimensions
Applications
Generators
Construction Equipment Garden Tractors
Marine Applications
Medical Devices
2.30 [58.4]
0.75 [19.1]
0.05 [1.3]
0.13 [3.3]
0.21 [5.2]
1.98 [50.3]
www.redingtoncounters.com
Model 53
50
Electronic LCD Hour Meter
Part# Function Reset Input Terminations Color
hours min. sec. remote none manual switch 3-30VDC 20-250VAC/VDC term. block 8” wire leads tan black
The Model 53 Hour Meter with 7 LCD digits, 999999.9, and internal lithium battery, is ideal for applications requiring time accumulation for mainte-
nance scheduling, warranty monitoring, lease time or fee computation. Applications include test equipment, panel builders, mobile equipment and
medical devices. A choice of time ranges, in hours, minutes or seconds provides the user with a wide choice of recording increments.
Figures: 7 LCD figures, 0.32’’ [8mm] high
Reset: Remote, manual, and non-reset
Inputs: Switch (no-voltage), 3-30VDC, 20-250VAC/VDC (50/60Hz)
Vih* 20VAC/3VDC minimum
Vil* 3VAC/1VDC maximum
Power: Self-powered (internal lithium battery)
Mounting: Panel with clip
Terminations: Terminal block, or connector - 8’’ [200mm] wire leads
Weight: 2 oz. [57g]
Battery Life: ~20years
Accuracy: Quartz accuracy (better than 0.01%)
Approvals: UL Recognized, CSA Certified, CE Compliant
Lithium battery
Choice of manual reset, remote reset or non-reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Termination
Case color
Private labeling
Mounting adapter plates
5003-001S - gasket
Low AC voltage (4-30 VAC)
Specifications
Features Options
Description
Temperature
Operating: -4°F to +140°F [-20°C to +60°C]
Storage: -40°F to +165°F [-40°C to +75°C]
Humidity: 0 to 95% RH, non-condensing
Vibration
Operating: 10 to 55Hz, 0.01” [0.25mm] double amplitude
Non-Operating: 10 to 55Hz, 0.03” [0.75mm] double amplitude
Shock
Operating: 10G
Non-Operating: 30G
Dielectric: 1000VAC 50/60Hz for 1 minute
5320-0000 XX X X X
5320-0001 X X X X X
5321-0000 X X X X X
5321-0001 X X X X X
5322-0000 X X X X X
5322-0001 X X X X X
5320-0100 XXXX X X
5320-0101 X X X X X X
5320-1000 XX X X X
5320-1001 X X X X X
5320-1010 X X X X X
5320-1011 X X X X X
5320-1100 XXXX X X
5320-2000 XX XX X
5320-2001 X X X X X
5320-2200 X X X X X
5320-2201 X X X X X
5320-2100 XXX XX X
Models
* Items in bold are normally in factory stock.
Note: When interfacing the Model 53 with a Solid State Relay or AC Sensor, the leakage current need to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
www.redingtoncounters.com 51
Model 53 Electronic LCD Hour Meter
MOUNTING:
Unit Optional
Gasket Panel Clip
WIRING:
The mounting clip accommodates panel thicknesses up to 1/4”
[6.4mm].
Panel adapter plates are available in flush and 2 hole mount to fit
various panel cutouts. Consult the factory for availability.
Color code for the 8” [203mm] lead wires (24AWG) are:
1 - Yellow
2 - Blue
3 - Black
4 - Violet
5 - Gray
NOTES:
All resettable hour meters can be reset by a pulse with a minimum duration of 6 milliseconds.
SPECIAL WIRING OPTION
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option does not apply
for units with input of 20 - 250VAC/VDC or manual reset enable.
OPTIONAL INPUTS:
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
1.79 +/- 0.01
[45.5 +1/-0]
0.89 +/- 0.01
[22.6 +1/-0] Panel Cutout
Terminal block will accept wire sizes from 14 to 24AWG.
3 - 30VDC units are protected for transient voltages up to 50 volts
with pulse widths of up to 1 second at a 1% duty cycle (including
reverse polarity).
The operating AC frequency range is 40 to 400Hz.
Operating Instructions
TERMINAL BLOCK WIRE LEADS
0.86 [21.8]
0.10 [2.5]
1.58 [40.0]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
Applications
Dimensions
Medical Equipment Test Equipment Office Equipment
(Pin 1 is not used)
RESET
INPUT
20 - 250VAC/VDC
1 2 3 4 5
AC/DC AC/DC
RESET
INPUT
(Pin 1 is not used)
3 - 30 VDC
1 2 3 4 5
+DC
+DC
SWITCH (non-voltage)
RESET
INPUT
(Pin 1 is not used)
1 2 3 4 5
0.86 [21.8]
0.10 [2.5]
1.72 [43.7]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
www.redingtoncounters.com
Model 55
52
Electronic LCD Hour Meter/Counter
1/10th or 1/100th hour indication, or counts
Reset type
Case configuration
Termination
Count speed
Manual, remote or non-reset
EEPROM for memory (no battery)
AC or DC input voltages
3 housing configurations
1/10th or 1/100th hours indication
IP 65 front panel, without reset button
Display hours or counts
Choice of count frequency
The Model 55 LCD hour meters and counters offer a flexible choice for basic hour meter or counter function. Three variations of cases make the
Model 55 flexible for your installation requirements. Because all information is saved in an internal EEPROM memory, no battery is required. A
broad range of AC or DC input voltages make the Model 55 a versatile product for most applications. Two operating versions of the hour meter
and three operating versions of the counter are offered. These include hour meters that display hours to resolutions of 1/100th or 1/10th of an
hours and counters that operate with maximum input rates of 30 Hz or 200 Hz for DC inputs and 10 Hz for AC inputs. The Model 55 includes
models with reset options that include remote reset, manual and remote reset, and non-reset. A model designed to mount to a printed circuit
board is available upon request.
Figures: 7 LCD figures, 0.28’’ [7mm] high
Quartz Accuracy: 0.01%
Reset: Manual and remote, non-reset and remote only
No manual reset for round model
Input Voltage: 12/24 VDC ±25%
115-240 VAC ±10% 50/60 Hz
Special Voltage: 24 VAC/DC ±10%, 24-48 VDC ±25%
Current: 12-24 VDC & 24-48 VDC/2-4 mA
24 VAC/DC/2 mA
115-240 VAC/7- 15 mA
Mounting: Retaining clip
Terminations: 1/4” spade or screw terminals
Approvals: UL Recognized, CE Compliant
Operating Temp: -22 °F to +158 °F [-30°C to +70°C]
Humidity: 0 to 95% RH, non-condensing
Protection: Without reset button-IP 65, gasket supplied,
With reset button-IP54
EMC: EN 55011, EN 50082-2
Vibration: 1 g (10-500 Hz) IEC 68-2-34
Shock: 30 g (18 msec.) IEC 68-2-27
25 g (6 msec.) IEC 68-2-29
Max Count Speed: 30, 200 Hz DC or (10 Hz AC or AC/DC)
Memory: EEPROM (no battery)
Case Material: Black, ABS plastic with glass lens on round
model only
Weight: 2 oz. [57g]
For Details on Models and Descriptions, see the Ordering Information section.
Description
Specifications
Models Description
Applications
Panel builders Medical devicesPackaging machinery
Test equipment Compressors Piece count
OptionsFeatures
53
www.redingtoncounters.com
Model 55 Electronic LCD Hour Meter/Counter
Dimensions
1.77 [45.0]
1.47 [37.3]
0.12 [3.0]
1.89 [48.0]
1.89 [48.0] 1.77 [45.0]
PANEL CUT OUT: 1.78 [45.2] SQUARE
1.77 [45.0]
1.47 [37.3]
0.12 [3.0]
0.94 [24.0]
1.89 [48.0]
0.87 [22.0]
PANEL CUT OUT: .876 [22.2] X 1.772 [45]
0.31 [8.0]
1.50 [38.0]
Ø2.20 [56.0]
Ø2.04 [51.7]
PANEL CUT OUT: Ø2.055 [52.2]
0.10 [2.5]
0.38 [9.5]
0.18 [4.5]
0.17 [4.3]
0.89 [22.6] 1.03 [26.2]
1.97 [49.9]
1.83 [46.4]
2.11 [53.5]
0.10 [2.5]
Rectangular
SquareRound
Mounting Clip
Maximum Panel Thickness for all units: 0.15’’ [6.4mm]
Wiring Diagram
www.redingtoncounters.com
Model 55
54
Electronic LCD Hour Meter/Counter
55 PRODUCT NUMBER
TYPE 0 COUNTER
1 HOUR METER
HOUSING 0 0.94’’ X 1.90’’ [24 X 48 mm] RECTANGULAR
STYLE 1 1.90’’ X 1.90’’ [48 X 48 mm] SQUARE
2 2.2” [56 mm] ROUND
VOLTAGE 0 12 - 24 VDC
1 *24 - 48 VDC
2 *24 VAC/VDC
3 115 - 240 VAC 50/60 Hz
RESET 0 NON-RESET
1 REMOTE ONLY RESET
2 **MANUAL & REMOTE RESET
0 1/10 HOUR (HOUR METER)
READOUT 1 1/100 HOUR (HOUR METER)
MAX. SPEED 2 DC (30 Hz) (COUNTER)
3 DC (200 Hz) (COUNTER)
4 AC or AC/DC (10 Hz) (COUNTER)
TERMINALS 0 1/4” SPADE
1 SCREW TERMINALS
* Special voltage - consult factory
** Manual reset not available on round case style.
Note: The counter display is updated on the trailing edge of the input signal.
5 5 x x - x x x x
55
www.redingtoncounters.com
Model 56 Electronic LCD Hour/Counter/Maintenance Meter
The Redington Model 56 family of LCD indicators offers a variety of options to fulfill your count/hour meter requirements. This indicator can
display hours, counts or both with a single-line shared display. You decide which value should be displayed permanently and which one will be in
the background. The background indication will appear for approximately 10 seconds every time you apply power to the meter.
The Model 56 family offers you many features that are set at the factory at your request. These features include, input voltages, maximum count
speeds or minimum hour meter indication times, connector terminations, reset configurations, a Redi-Alert Service Interval feature, prewarn, and
input scaling.
The Model 56 family can be ordered to accommodate any of a number of AC or DC input voltages and reset configurations. The counter can be
ordered for maximum input count speeds of 10 Hz for AC or AC/DC voltages and 30 Hz or 200 Hz for DC voltages. The hour meter can be
ordered to display time intervals of 1/100th or 1/10th of hours. When using a counter and an hour meter in combination, the counter will count the
number of input pulses while the hour meter will record the total duration of the input pulses.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or
time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The Redi-
Alert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what
remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service
Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has
gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached.
When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the
indicator resets the Service Interval to its specified setting and returns the Service Interval to the background.
You can configure your Model 56 meter using the Ordering Information sheet.
Display: 7 digit, 0.28 [7mm], LCD, 1 display
Quartz Accuracy: 0.01%
Input Voltage: 12/24 VDC/ ±25%
115-240 VAC 50/60 Hz/±10%
Special Voltages: 24-48 VDC/±25%
24 VAC 50/60 Hz/VDC/±10%
Current Consumption: 12-24 VDC & 24-48 VDC/2-4 mA
24 VAC/VDC/2 mA
115-240 VAC/7-15 mA
Protection: Without reset button-IP 65, gasket supplied,
with reset button-IP54
EMC: EN 55011, EN 50082-2
Vibration: 1 g (10-500) IEC 68-2-34
Shock: 30 g (18 msec.) IEC 68-2-27
25 g (6 msec.) IEC 68-2-29
Max. Count Speed: 30, 200Hz DC or (10 Hz AC or AC/DC)
(specify)
Specifications
Features Options
Description
Display hours or hours and counts
“Redi-Alert” for service hours or counts
Manual, remote or non-reset
EEPROM for memory (no battery)
Divider/multiplier on inputs
AC or DC input voltage
3 housing configurations
Choice of 1/100th or 1/10th hours (specify)
Input scaling
Input frequency
Reset type
Indication of time/count
Wide selection of input voltage
Service “Redi-Alert”
Memory: EEPROM (no battery)
Approvals: UL Recognized, CE Compliant
Mounting: Retaining clip
Electrical Connection: 1/4” [6.4mm] spade or screw terminals
Case Material: Black, ABS plastic with glass lens on
round model only
Reset: Manual and remote, non-reset and
remote only
No manual reset for round model
Operating Temperature: -22°F to +158°F [-30°C to +70°C]
Weight: 2 oz [57g]
Service Alert: Factory set - one “Redi-Alert”, 4 digits
Input Scaling: Factory set, 4 digits
Prewarn Signal: Factory set, 4 digits
www.redingtoncounters.com
Model 56
56
Electronic LCD Hour/Counter/Maintenance Meter
Dimensions
1.77 [45.0]
1.47 [37.3]
0.12 [3.0]
1.89 [48.0]
1.89 [48.0] 1.77 [45.0]
PANEL CUT OUT: 1.78 [45.2] SQUARE
1.77 [45.0]
1.47 [37.3]
0.12 [3.0]
0.94 [24.0]
1.89 [48.0]
0.87 [22.0]
PANEL CUT OUT: .876 [22.2] X 1.772 [45]
0.31 [8.0]
1.50 [38.0]
Ø2.20 [56.0]
Ø2.04 [51.7]
PANEL CUT OUT: Ø2.055 [52.2]
0.10 [2.5]
0.38 [9.5]
0.18 [4.5]
0.17 [4.3]
0.89 [22.6] 1.03 [26.2]
1.97 [49.9]
1.83 [46.4]
2.11 [53.5]
0.10 [2.5]
Rectangular
SquareRound
Mounting Clip
For Details on Models and Descriptions, see the Ordering Information section.
Models Description
Medical DevicesPackaging MachineryTest Equipment
Applications
Maximum Panel Thickness for all units: 0.15’’ [6.4mm]
Wiring Diagram
57
www.redingtoncounters.com
Model 56 Electronic LCD Hour/Counter/Maintenance Meter
Ordering Information
Model 56
Specification Sheet
Company: __________________________ Phone: ____________________
Address: __________________________ Fax: ____________________
__________________________ Email: ____________________
Contact: __________________________ Date: ____________________
Model No. ___________ (4 digits) SELECTED FROM ABOVE TABLE .
Input Voltage: (check only 1)
12-24 VDC 115-240 VAC 50/60 Hz Special voltages available, consult factory.
Indication of time for Hour Meter: (check only 1)
1/100th 1/10th
Max. counting frequency for Counter: (check only 1)
30 Hz (DC) 200 Hz (DC) 10 Hz @ (AC) or (AC/DC)
Termination : (check only 1)
1/4” spade screw terminals
Reset Types: (check only 1)
non-reset remote reset remote and manual reset (No manual reset for 2.2 “ Round Model)
Service Interval: (optional)
“Redi-Alert” : (4 digits max) Prewarn : (4 digits max)
Input scaling: (optional - check only 1)
Divider: (4 digits max) Multiplier: (4 digits max)
Note: The counter display is updated on the trailing edge of the input signal
FUNCTION HOUSING DIMENSIONS NOTES
1 X 2 INCH 2 X 2 INCH ROUND 2.2 INCH
HM WITH HM (bg)* 5600 5601 5602 Only HM is resettable
C WITH C (bg)* 5610 5611 5612 Only C is resettable
HM WITH C (bg)* 5620 5621 5622 Both are resettable
C WITH HM (bg)* 5630 5631 5632 Both are resettable
HM WITH SHM (bg)* 5640 5641 5642 Only SHM (bg) is resettable
C WITH SC (bg)* 5650 5651 5652 Only SC (bg) is resettable
SHM WITH HM (bg)* 5660 5661 5662 Only SHM is resettable
SC WITH C (bg*) 5670 5671 5672 Only SC is resettable
*HM= Hour Meter *C= Counter *bg= Background *SHM= Service Hour Meter *SC= Service Counter
www.redingtoncounters.com
Model 57
58
Electronic LCD Hour/Counter/Maintenance Meter
The Redington Model 57 family of LCD indicators offers a variety of options to fulfill your count/hour meter requirements. This indicator can
display hours, counts or both with a single-line shared display. This model is available with an LED indication for service and relay or transistor
output. You decide which value should be displayed permanently and which one will be in the background. The background indication will appear
for approximately 10 seconds every time you apply power to the meter.
When using a counter and an hour meter in combination, the counter will count the number of input pulses while the hour meter will record the total
duration of the input pulses.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or
time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The Redi-
Alert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what
remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service
Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has
gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached.
When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the
indicator resets the Service Interval to its specified setting and returns the Service Interval to the background.
The LED indicator and output will come on once the Redi-Alert is reached and stay on until reset.
The Model 57 family also offers the option of an additional display for those applications that require dual indications.
Choice of single or dual displays
Display counts/hours or both
Factory programmed service alert
Divide/multiply on inputs (factory set)
With or without reset
Output signal: none, relay or transistor
Service indicator available
DC input voltages
IP 65 sealed front panel
EEPROM for memory (no battery)
Input scaling
Count speed
Reset type
Indication of time/count
Type of output
One or two displays
LED indication for service
Maintenance Redi-Alert output
Features Options
Description
Display: Large 7 digit, 0.28 [7mm], LCD
1 or 2 displays
Quartz Accuracy: 0.01% over entire voltage & temp. range
Input Voltage: 12-24 VDC/ ±25%
24 VDC/ ±25% - with relay output
Special Voltages: 24-48 VDC/ ±25%
12,36,48 VDC/ ±25%-with relay output
Current Consumption: 12-24 VDC/<10 mA, 24-48 VDC/<10 mA
(12 V/< 35 mA, 24 V/< 25 mA, 36 V/<25
mA, 48 V/< 20 mA) with relay
Relay Contact: 1 dry contact / breaking capacity
12 V/2 A, 24 V/2 A, 36 V/1.5 A, 48 V/1 A
Transistor Output: VOH 4.5 VDC, minimum through 30 KW
VOL 0.4 VDC, maximum through 20 KW
ISINK 1.0 mA, maximum
Operating Temperature : -22 °F to +158 °F [-30 °C to +70 °C]
Approvals: CE Compliant
Protection: IP 65 front panel/gasket supplied
EMC: EN 55011,EN 50082-2
Vibration: 1g (10…500 Hz) IEC 68-2-34
Shock: 30 g(18 msec.) IEC 68-2-27
25 g(6 msec) IEC 68-2-29
Max Count Speed: 30 or 200 Hz (specify)
Memory: EEPROM (no battery)
Mounting: Metal clamp
Electrical Connection: 8 pole compact plug with lock
Case Material: Black, ABS plastic w/glass lens
Reset: Manual & remote (manual button on the
rear of housing), non-reset, remote
Service Alert: Factory set - one Redi-Alert, 4 digits
Prewarn Signal: Factory set, 4 digits
Input Scaling: Factory set, 4 digits
Weight: 3.5 oz [99g]
Specifications
59
www.redingtoncounters.com
Model 57 Electronic LCD Hour/Counter/Maintenance Meter
Ø2.20 [56.0] Ø2.20 [56.0]
0.31 [8.0] 1.68 [42.7]
2.30 [58.5]
Ø2.05 [52.0]
MOUNTING CLIP
RM
1234
876
5
Maximum Panel Thickness: 0.20” [5.1mm]
Panel Cutout: 2.06” [52.2mm]
Applications
Dimensions
For Details on Models and Descriptions, see the Ordering Information section.
Models Description
Packaging MachineryPanel Builders Medical Devices Test Equipment
8
1
2
3
4
6
7
5
+
-
relay output
8
1
2
3
4
6
7
5
5V
Out
+
-
NPN Transistor output
10k
20k
8 = operating voltage "+"
1 = Input display 1
2 = reset display 1
3 = relay output "+"
4 = relay output "-"
6 = Input display 2
7 = reset display 2
5 = operating voltage "-"
8 = operating voltage "+"
1 = Input display 1
2 = reset display 1
3 = transistor output
4 = not used
6 = Input display 2
7 = reset display 2
5 = operating voltage "-"
Wiring Diagram
www.redingtoncounters.com
Model 57
60
Electronic LCD Hour/Counter/Maintenance Meter
Ordering Information
Display 1
Indication of time for Hour Meter: (check only 1)
1/100th 1/10th
Max. counting frequency for Counter: (check only 1)
30 Hz 200 Hz
Reset types: (check only 1)
non-reset remote reset
remote & manual (manual reset on rear of housing)
Service interval (optional)
“Redi-Alert”: _____________ ( 4 digits max)
Prewarn: _____________ (4 digits max.)
Input scaling (optional - check only 1)
Divider _______________ ( 4 digits max)
Multiplier _______________ ( 4 digits max)
Model No. ___________ (4 digits) SELECTED FROM ABOVE TABLE
Display 2 (Optional) Yes No
Indication of time for Hour Meter: (check only 1)
1/100th 1/10th
Max. counting frequency for Counter: (check only 1)
30 Hz 200 Hz
Reset types: (check only 1)
non-reset remote reset
remote & manual (manual reset on rear of housing)
Input scaling: (optional - check only 1)
Divider _______________ ( 4 digits max)
Multiplier _______________ ( 4 digits max)
Model 57
Specification Sheet
Company: __________________________ Phone: ____________________
Address: __________________________ Fax: ____________________
__________________________ Email: ____________________
Contact: __________________________ Date: ____________________
*HM= Hour Meter *C= Counter *bg= Background *SHM= Service Hour Meter *SC= Service Counter
Model No. Voltage Function Reset Notes
5700 12 - 24 VDC HM* HM without output or LED
5701 12 - 24 VDC C* C without output or LED
5702 12 - 24 VDC HM with HM (bg)* HM without output or LED
5703 12 - 24 VDC C with C (bg)* C without output or LED
5704 12 - 24 VDC HM with C (bg)* BOTH without output or LED
5705 12 - 24 VDC C with HM (bg)* BOTH without output or LED
5706 24 VDC HM with SHM (bg)* SHM with relay output and LED
5707 12 - 24 VDC HM with SHM (bg)* SHM with transistor output and LED
5708 24 VDC C with SC (bg)* SC with relay output and LED
5709 12 - 24 VDC C with SC (bg)* SC with transistor output and LED
5710 24 VDC SHM with HM (bg)* SHM with relay output and LED
5711 12 - 24 VDC SHM with HM (bg)* SHM with transistor output and LED
5712 24 VDC SC with C (bg)* SC with relay output and LED
5713 12 - 24 VDC SC with C (bg)* SC with transistor output and LED
61
www.redingtoncounters.com
Model 59 Electronic LCD Hour/Counter/Maintenance Meter
The Redington Model 59 line of LCD modules can easily be integrated into your equipment or machinery. These functions are also available in
cased versions, ask for more information, or see Model 55, 56 & 57.
Single Indicator:
Can be used to display hours or count.
Twin Indicator:
These models can supply two indications in one display. You can decide which function should be indicated permanently and which one in the
background. The background function displays for approximately 10 seconds every time you power-up the display. When using a counter and an
hour meter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input pulses.
Presettable “prewarn” signals can also be programmed into the modules. If you specify a prewarn the display will flash when it reaches its
specified value. A wide range of reset functions are also available to provide you with the exact configuration for your application. Model 57 is
available with an output function to “alert” when service or preventive maintenance should occur.
Redi-Alert:
The Redington Model 59 LCD Maintenance Meter modules can easily be integrated into your equipment or machinery. This module can display
hours, counts or both with a single-line, shared display. You can decide which function should be indicated permanently and which one is in the
background. The background function, value, appears for approximately 10 seconds every time you power-up the display. When using a hour
meter and counter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input
pulses. A wide range of reset functions are available to provide you with the exact configuration for your application.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or
time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The Redi-
Alert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what
remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service
Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has
gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached.
When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the
indicator resets the Service Interval to its specified setting and returns the Service Interval to the background. The LED indicator and output will
come on once the Redi-Alert is reached and stay on until reset.
Display time/count or both
“Redi-Alert” function for service
Choice of non-reset or remote reset
EEPROM for memory (no battery)
Divider/multiplier
30 or 200 Hz, max input frequency
1/10th or 1/100th hour indication
12 to 24 VDC power range
Input scaling
Input frequency
Remote reset
Service “Redi-Alert”
Display functions
Features Options
Description
Display: 7 digit, 0.28 [7mm], LCD
Quartz Accuracy: 0.01%
Input Voltage: 12-24 VDC/ ±25%
Current Consumption: 2-4 mA
Transistor Output: VOH 4.5 VDC, minimum through 30 KW
VOL 0.4 VDC, maximum through 20 KW
ISINK 1.0 mA, maximum
Operating Temperature: -22°F/+158°F [-30°C to +70°C]
Max Count Speed: 30 or 200 Hz
Memory: EEPROM (no battery)
Approvals: UL/cUL Recognized
Mounting: Electrical connection pins for soldering
Electrical Connection: Pins for soldering
Reset: Non-reset, remote
Protection:
EMC: EN 55011, EN 50082-2
Vibration: 1 g (10 to 500 Hz ) IEC 68-2-34
Shock: 30 g (18 msec.) IEC 68-2-27
25 g (6 msec.) IEC 68-2-29
Weight: 0.5 oz [14g]
Service Alert: 1 “Redi-Alert”, 4 digits, factory set
Input Scaling: Factory set, 4 digits
Prewarn Signal: Factory set, 4 digits
Specifications
For Details on Models and Descriptions, see the Ordering Information section.
Models Description
www.redingtoncounters.com
Model 59
62
Electronic LCD Hour/Counter/Maintenance Meter
0.28 [7.1]
1.10 [27.9]
1.65 [42.0]
0.07 [1.8]
1.00 [25.4]
0.86 [21.8]
0.24 [6.2]
0.12 [3.05]
0.55 [13.9]
1.48 [37.5]
0.37 [9]
0.58 [14.7]
-+
0.12 [3.05]
COUT
0.28 [7.0]
0.07 [1.7] 0.57 [14.6] 0.15 [3.8] MAX
HEIGHT OF
COMPONENTS
Ø0.06 [1.5]
OPTION
PIN:
+ = OPERATING VOLTAGE
- = GND
C = COUNT
OUT = SERVICE COUNTER OUTPUT (OPTION)
ALTERNATINE POSITIONS OF THE CONNECTION PINS
ARE OPTIONALLY POSSIBLE.
R
*HM=HOUR METER *C= COUNTER *bg=BACKGROUND *SC= SERVICE COUNTER *SHM= SERVICE HOUR METER
Model No. ___________ (4 digits) SELECTED FROM ABOVE TABLE .
Input voltage: (check only 1)
12-24 VDC Special voltages available, consult factory.
Indication of time for Hour Meter: (check only 1)
1/100th 1/10th
Max. counting frequency for Counter: (check only 1)
30 Hz (DC) 200 Hz DC
Reset type: (check only 1)
non-reset remote reset
Service interval: (optional)
“Redi-Alert” : (4 digits max) Prewarn : (4 digits max)
Input scaling: (optional - check only 1)
Divider: _______________ (4 digits max) Multiplier: ______________ (4 digits max)
Dimensions
Applications
Ordering Information
Model 59
Specification Sheet
Company: __________________________ Phone: ____________________
Address: __________________________ Fax: ____________________
__________________________ Email: ____________________
Contact: __________________________ Date: ____________________
Medical DevicesTest Equipment Panel Builders Office Equipment Flow Meters
Output Signal
-
-
-
-
-
-
included
included
included
included
Model#
5902
5912
5922
5932
5942
5952
5962
5972
5982
5992
Function
SINGLE FUNCTION
HM*
C*
TWO FUNCTION
HM with HM (bg)*
C with C (bg)*
HM with C (bg)*
C with HM (bg)*
HM with SHM (bg)*
C with SC (bg)*
SHM with HM (bg)*
SC with C (bg)*
Notes
HM is resettable
C is resettable
Only HM is resettable
Only C is resettable
Both are resettable
Both are resettable
Only SHM (bg) is resettable
Only SC (bg) is resettable
Only SHM is resettable
Only SC is resettable
5V
Out
20k
10k
+
-
C / Input
R
Wiring Diagram
NPN Transistor Output
63
www.redingtoncounters.com
Model 94 Electronic LCD Hour Meter
A 6 figure, battery powered, push-button or key reset, electronic hour meter, available in base mount or panel mount configuration. No external
power supply is required. Large 0.50’’ [12mm] LCD figures for fast, easy reading. Operates at 6-240 VAC or VDC. Long lasting internal lithium
battery. Attractive styling and silent operation make these models equally well-suited for lab or office equipment applications.
Figures: 6 LCD figures, 0.50’’ [12mm] high
Reset: Push-button, or lock and key
Input: 6-240VAC (50/60Hz) or 6-240VDC
Vih 6VAC/VDC minimum
Vil 2VAC/VDC maximum
Mounting: Base or panel
9425-001 6 figure, base mount, push-button reset
9425-003 6 figure, panel mount, push-button reset
9425-005 6 figure, panel mount, lock and key reset
* Items are normally in factory stock.
Applications
Dimensions
Models Description
Description
Features Options
Specifications
Non-reset
Remote reset
Minutes meter
Seconds meter
No external power supply needed
Long life lithium battery
Large easy reading display
Operates at 6 to 240 VAC or VDC
Office equipment Production Test labs Control panels
Terminations: (2) #22 AWG 221°F [105° C] wire leads,
8’’ [203mm] long
Temp. Range: -14°F to +122°F [-26°C to +50°C]
Power Source: Internal lithium battery
Weight: 18 oz. [510g]
Base Mount Panel Mount
Mounting holes: 0.14’’ x 0.24’’ [3.6mm x 6.1mm] slots Panel cutout: 3.0’’ x 1.75” [76.2mm x 44.5mm]
Mounting holes: 0.17’’ [4.3mm] Dia.
1.75 [44.4]
2.97 [75.3]
1.65 [41.9]
3.15 [80.0]
3.81 [96.8]
3.23 [82.0]
3.31 [84.1]
0.88 [22.2]
1.36 [34.4]
1.87 [47.6]
1.50 [38.1]
4.06 [103.2]
3.15 [80.0]
4.44 [112.7]
1.65 [41.9]
2.90 [73.5]
1.41 [35.8]
Panel Mount/Lock & Key Reset
1.41 [35.8]
2.90 [73.5]
3.15 [80.0]
5.50 [139.7]
2.12 [54.0]
1.65 [41.9]
1.75 [44.5]
5.13 [130.2]
Panel cutout: 4.75 ’’ x 1.50” [76.2mm x 44.5mm]
Mounting holes: 0.17’’ [4.3mm] Dia.
Note: When interfacing the Model 94 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact
the factory or see the application note at www.redingtoncounters.com for further information.
www.redingtoncounters.com
Model 720 Electronic
64
LCD Hour Meter
Description
Features Options
Specifications
Dimensions
Applications
The Redington Model 720 Electronic Hour Meter offers a large 7 digit LCD display, (999999.9) 0.32" (8mm) high, with an input operating voltage
of 85-500VAC. The front of the unit is totally sealed, and the Hour Meter is housed in a rugged steel enclosure that is interchangeable with the
Redington Model 720 Electro Mechanical Hour Meters. The wide operating voltage makes this product ideal for almost any application.
Gasket (721-0004)
Special termination available
•DC
Display: Large 7 digit LCD (999999.9), 0.32" [8mm] high
Reset: Non-reset
Voltage: 85-500VAC 50/60Hz
Hour Meter Memory: Self-powered (internal lithium battery)
Termination: Wire leads 6" [152mm]
Mounting: Panel (3-Hole)
Temp. Range:
Operating: -4°F to + 140°F(-20°C to +60°C)
Storage: -40°F to +165°F (-40°C to +75°C)
Humidity: 0 to 95% RH, non-condensing,
front totally sealed
Vibration: 10 to 80 Hz, 0.06 double amplitude
Shock: 50G
Dielectric: 1000VAC 50/60Hz for 1 minute
Accuracy: Quartz accuracy (better than 0.01%)
Weight: 5.0 oz (142g)
720-5300 85-500VAC, non-reset, 3-hole round, 6" (152mm) wire leads
* Item is normally in factory stock.
720-5300
Panel cutout: 2.16’’ [54.9] Dia.
Mounting holes: 0.125’’ [3.2] Dia. on 2.44’’ [62.0] B.C.
Operating voltage 85-500VAC
Rugged steel housing
Lithium battery
Quartz accuracy (better than 0.01%)
Popular 3-hole mounting
Control panels Outdoor Lighting Test equipment
Models Description
2.37 [60.2]
Ø2.14 [54.2]
Ø2.66 [67.5]
3X Ø.125 [Ø3.2] EQUALLY SPACED
ON A 2.44[62.0] B.C.
6 IN. LEADS
Industrial Equipment Compressors
65
www.redingtoncounters.com
Model 77 Electromechanical Hour Meter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
P-7717
The Model 77 is a compact, non-reset, 6 figure, 99999.9, electromechanical hour meter. Available with several mounting styles, panel, behind the
panel and “snap-in” mount. Products are UL Recognized, CSA Certified and CE Compliant.
Figures: 6 figures, 0.11’’ [3mm] high
99,999.9 hours
Reset: Non-reset
Voltages: 115VAC, (+/- 10%) 60Hz.
Power: 3 watts (nominal)
Voltage
Frequency
Mounting
Mounting: Panel (front, behind, or snap-in)
Termination: Screw type, round terminals
Temp. Range: -60°F to +154°F [-51°C to +68°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 2.5 oz. [71g]
P2-7717/60 115VAC/60Hz, non-reset, panel mount
R2-7717/60 115VAC/60Hz, non-reset, behind the panel mount
SR2-7717/60 115VAC/60Hz, non-reset, snap-in mount
1.80 [45.8]
1.80 [45.6]
123456
1.40 [35.5]
0.14 [3.6]
2.11 [53.6]
1234561.44 [36.5]
1.80 [45.8] 2.07 [52.6]
SR-7717
Panel cutout: 1.72’’ x 1.05’’ [43.7 x 26.7]
Mounting holes: For #5 flat head screw Panel cutout: 1.68’’ x 1.31’’ [42.7 x 33.3]
Panel or snap-in mount
Compact size
Non-reset
Test equipment Control panels Office machines Industrial equipment
www.redingtoncounters.com
Model 710
66
Electromechanical Hour Meter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
8” [203mm] Wire Leads
The model 710 AC hour meters and minute meters are widely used in panel applications where number size and visibility are critical. Its tough, Lexan
bezel and distinctive styling enhance appearance and durability. Available in 5 figure reset or 6 figure non-reset versions.
Figures: 5 figures, 9999.9 (reset) or 6 figure, 99999.9
(non-reset), 0.19’’ [5mm] high
Reset: Reset (on front or side) or non-reset
Voltages: 24, 115 or 230VAC, (+/-10%), 50 or 60 Hz.
Power: 3 watts (nominal)
Mounting: Panel (3-hole)
Terminations: 8’’ [203.2mm] wire leads or terminal block
Temp. Range: -20°F to +160°F [-29°C to +71°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 6 oz. [170g]
Private label faceplates
Bracket mount
Mounting bracet (721-0003)
Splash proof kit (721-0017)
Heavy duty splash proof kit (721-0018)
Gasket (721-0004)
710-0001 115VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads
710-0002 115VAC/60Hz, non-reset, 99,999.9 hrs, terminal block
710-0003 230VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads
710-0006 24VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads
710-0008 115VAC/60Hz, non-reset, 99,999 hrs, 8’’ [203mm] wire leads
710-0009 115VAC/50Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads
710-0013 115VAC/60Hz, front reset, 9,999.9 hrs, 8’’ [203mm] wire leads
1 2 3456
2.84 [72.1]
1.98 [50.3]
2.40 [61.0]
2.18 [55.2]
DIA
0.19 [4.8]
Mounting holes: For #4 screws on 2.44” [62.0] B.C.
and #6 screws on 2.53” [64.3] B.C.
Panel cutout: 2.21’’ [56.1] Dia.
Large figures
Tough, Lexan case
Reset or non-reset
Control panels Industrial equipment Test equipment CompressorsOffice equipment
710-0014 230VAC/60Hz, non-reset, 99,999.9 hrs, terminal block
710-0018 115VAC/60Hz, non-reset, 99,999.9 min, 8’’ [203mm] wire leads
710-0024 24VAC/60Hz, non-reset, 99,999.9 hrs, terminal block
710-0026 115VAC/50Hz, non-reset, 99,999.9 hrs, terminal block
710-0032 115VAC/60Hz, front reset, 9,999.9 hrs, terminal block
710-0051 115VAC/60Hz, non-reset, 99,999 hrs, terminal block
* Items in bold are normally in factory stock.
www.redingtoncounters.com 67
Model 711/731 Electromechanical Hour Meter
7 figure, 99999.99
Various voltage inputs
Quartz accuracy (DC)
Large figures, 0.14" [3.6mm]
CE Compliant
UL Recognized/CSA Certified for AC
UL/cUL Recognized for DC
Environmental:
Front Panel: IP65
Operating Temperature: -40°F to +180°F [-40°C to +82°C]
Storage Temperature: -40°F to +185°F [-40°C to +85°C]
Humidity: 95% RH- SAE J 1378
Vibration: 20g’s @ 10-80 Hz- SAE J 1378
Shock: 55g’s @ 9-13 msec.- SAE J 1378
Transient Immunity: EMI: ± 400V@ 500Hz
Alternator Load Dump: 150V inductive switching, reverse
polarity and over voltage protection
Special voltages
Terminations
Panel cutout
The Redington Model 711/731 provides a family of compact 7 figure, AC or DC Hour Meters. Models are available in the standard industry
housings, 2-Hole rectangular, flush-round and flush-rectangular. DC Models are quartz controlled for high reliability and accuracy. A choice of two
rectangular panel cutouts are offered 1.45" X 0.95’’ [36.8mm X 24.1mm] or 1.45" X 0.87" [36.8mm X 2.1mm]. The Round meter has a panel cutout
of 1.99" [50.5mm].
Figures: 7 figures, 0.14" [3.6mm] 99999.99
Reset: Non-reset
Voltages: 24, 115 or 230VAC (± 10%), 50 or 60 Hz 10-28VDC
Power: 2 watts AC, 0.4 watts DC
Mounting: Clip or mounting holes
Termination: 1/4” [6.3mm] spade terminals with screws (AC)
1/4” [6.3mm] spade terminals (DC)
Accuracy: 0.01% (DC) quartz
Case Material: Black polymer
Agency Approvals: CE Compliant
UL Recognized/CSA Certified for AC
UL/cUL Recognized for DC
Weight: 1.2oz. [35g]
Models Voltage Mount Panel Cut-out
AC 1.45 X .87 1.45 X .95 1.99
711-0013 115VAC/60Hz Round X
711-0014 230VAC/60Hz Round X
711-0015 24VAC/60Hz Round X
711-0113 115VAC/60Hz Flush Rect X
711-0114 24VAC/60Hz Flush Rect. X
711-0120 115VAC/60Hz Flush Rect X
711-0123 230VAC/60Hz Flush Rect. X
711-0124 24VAC/60Hz Flush Rect. X
711-0130 115VAC/60Hz 2-Hole X
711-0131 230VAC/60Hz 2-Hole X
711-0132 24VAC/60Hz 2-Hole X
711-0133 115VAC/50Hz 2-Hole X
711-0134 230VAC/50Hz 2-Hole X
711-0138 230VAC/60Hz Flush Rect. X
711-0215 115VAC/60Hz 2-Hole X
711-0216 230VAC/60Hz 2-Hole X
711-0217 24VAC/60Hz 2-Hole X
Models Voltage Mount Panel Cut-out
DC 1.45 X .87 1.45 X .95 1.99
731-0006 10-28VDC Round X
731-0040 10-28VDC 2-Hole X
731-0041 10-28VDC Flush Rect X
731-0042 10-28VDC Flush Rect X
731-0051 10-28VDC 2-Hole X
Specifications
Features Options
Description
Models
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 711/731
68
Electromechanical Hour Meter
Dimensions
1 2 3 4 5 6 7
H O U R S
O2.28 [O58]
2.33 [59.3]
0.13 [3.3]
PANEL OPENING 1.99 [50.5] DIA
0.12 [2.9]
1.43 [36.2]
1.60 [40.6]
1.08 [27.4]
2.33 [59.2]
0.87 [22.0]
PANEL OPENING 1.45 [36.8] X 0.87 [22.1]
PANELTHICKNESS 0.50'' [12.7]
1 2 3 4 5 6 7
0.12 [3.0]
1.43 [36.2]
1.60 [40.6]
1.08 [27.4]
2.33 [59.2]
0.93 [23.5]
PANEL OPENING 1.45 [36.8] X 0.95 [24.1]
PANELTHICKNESS 0.50'' [12.7]
1 2 3 4 5 6 7
Medical equipment Office equipmentTest equipment
2X Ø.16 [Ø4.1]
1.75 [44.5]
2.1 [53]
0.9
[23] 1.21 [30.8]
1.43 [36.2]
0.08 [2.2]
2.33 [59.3]
0.93 [23.5]
PANEL OPENING 1.45 [36.8] X 0.95 [24.1]
0.06 [1.4]
1.4 [36]
1 2 3 4 5 6 7
2X Ø.16 [Ø4.1]
1.75 [44.5]
2.1 [53]
1.21 [30.8]
1.43 [36.2]
2.33 [59.3]
0.08 [2.2]
0.87 [22.0]
PANEL OPENING 1.45 [36.8] X 0.87 [22.1]
0.06 [1.4]
0.9
[23]
1.4 [36]
1 2 3 4 5 6 7
Applications
www.redingtoncounters.com 69
Model 711/731 Electromechanical Hour Meter
These 7 figure, AC or DC hour meters with running indicators, offer crisp, distinctive styling for many panel applications. Available in square and round
bezel, flush mount, or three-hole round panel mount. Each is light-weight, low power, and carry UL, CSA and CE approvals.
Specifications
Features Options
Description
Figures: 7 figures, 0.14’’ high [3.6mm], 99,999.99 hours
Reset: Non-reset
Voltages: 24, 115, or 230VAC (+/-10%), 50 or 60Hz., 10-80 VDC
Power: 3 watts (AC), 1.2 watt maximum (DC)
Terminations: 1/4’’ [6.3mm] spade terminals, with removable screws,
or 8’’ [203mm] wire leads
Terminations
Din rail
Voltages
Mounting: Panel (mounting hardware included)
Temp. Range: -22°F to +158°F [-30°C to +70°C]
Approvals: UL Recognized and CSA Certified (AC only),
CE Approved
Weight: 2 oz. [57g]
711-0150 115VAC/60Hz, 2.28’’ Dia.,Flush mount, screw termination
711-0152 230VAC/60Hz, 2.28’’ Dia., Flush mount, screw termination
711-0160 115VAC/60Hz, 2.93’’ Dia.,3-hole round, screw termination
711-0161 115VAC/50Hz, 2.93’’ Dia., 3-hole round, screw termination
711-0162 230VAC/60Hz, 2.93’’ Dia., 3-hole round, screw termination
711-0163 230VAC/50Hz, 2.93’’ Dia., 3-hole round, screw termination
711-0164 24VAC/60Hz, 2.93’’ Dia., 3-hole round, screw termination
711-0170 230VAC/60Hz, 2.93’’ Dia., 3-hole round, 8’’ wire leads
711-0171 115VAC/60Hz, 2.93’’ Dia., 3-hole round, 8’’ wire leads
711-0180 115VAC/60Hz, 1.89’’ Sq., Flush mount, screw termination
Models DescriptionModels Description
711-0182 24VAC/60Hz, 1.89’’ Sq., Flush mount, screw termination
711-0190 115VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination
711-0191 230VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination
711-0192 24VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination
711-0193 115VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination
711-0194 230VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination
711-0195 24VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination
731-0046 10-80VDC, 2.93’’ Dia.,3-hole round, screw termination
Dimensions
Applications
1.35 [34.3]
1.77 [44.9]
2.28 [57.9]
1.55 [39.3]
2.20 [55.9]
0.20 [5.1]
2.20 [55.9] 1.77 [44.9]
1.35 [34.3]
1.35 [34.3]
1.60 [40.6]
1.77 [44.9]
2.93 [74.5]
2.28’’ Dia. Flush 3 - Hole Round 1.89’’ or 2.05’’ Square
Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq.
(for 1.89’’ Sq. use 1.81’’ [46] Sq. cutout only)
Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq. Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq.
Screws provided: 4-40 x 5/8’’ [16]
Bolt hole circle: 2.44’’ [62]
Medical equipment Office equipmentTest equipment
7 figure, 99999.99
Various voltage inputs
Distinctive styling
* Items in bold are normally in factory stock.
www.redingtoncounters.com
70
Model 711 Electromechanical Hour Meter
A rectangular style AC hour meter designed to complement existing meters in control panels. Available in 6 figure reset or 7 figure non-reset. The non-
reset model incorporates a retaining clip to lock into panel, while the reset version has a metal bracket and screw.
Specifications
Features Options
Description
Reset or non-reset
Models Description
Dimensions
Applications
Medical equipment Office equipmentTest equipment
Figures: 6 figure (reset) or 7 figure (non-reset), 0.19’’ [5mm] high
9,999.99 hours. (reset version)
99,999.99 hours. (non-reset models)
Reset: Push-button, or non-reset
Voltages: 115VAC (+/- 10%), 50 or 60 Hz.
Power: 2 watts (nominal)
Mounting: Panel (mounting hardware included)
Termination: 19’’ [483mm] wire leads
Temp. Range: -4°F to +158°F [-20°C to +70°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 2 oz. [57g]
Options: Voltages
711-0019 115VAC/60Hz, reset, 6 figure, 9,999.99 hrs., 19’’ [483mm] wire leads
711-0020 115VAC/60Hz, non-reset, 7 figure, 99,999.99 hrs., 19’’ [483mm] wire leads
711-0041 115VAC/50Hz, non-reset, 7 figure, 99,999.99 hrs., 19’’ [483mm] wire leads
1
234567
2.13 [54.0]
1.14 [29.0]
1.77 [45.0]
0.98 [24.9]
0.12 [3.0]
Non-Reset
Large figures
6 or 7 digits
UL Recognized, CSA Certified, CE Compliant
Panel cutout: 1.98’’ x 0.99’’ [50.3 x 25.1] Panel cutout: 1.98’’ x 0.99’’ [50.3 x 25.1]
123456
2.13 [54.1]
1.14 [29.0]
2.95 [74.9]
0.98 [24.9]
0.18 [4.4]
0.19 [4.8]
Reset
71
www.redingtoncounters.com
Model 720 Electromechanical Hour Meter
Description
Features Options
Specifications
Models DescriptionModels Description
Dimensions
Applications
A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The
non-reset models are completely sealed, and meet NEMA 4 standards. Reset models are available, as are both wire lead and terminal block versions.
Chrome bezel
Readouts to 9999.99 hrs.
Minute meter
Voltages
Gasket (721-0004)
Figures: 5 figure (reset) or 6 figure (non-reset), 0.19’’ [5mm]
high, 9,999.9 (reset) or 99,999.9 (non-reset)
Reset: Reset or non-reset
Voltages: 24, 115, and 230VAC (+/- 10%), 50 or 60Hz.
Power: 2.5 watts (nominal)
Mounting: Panel (3-hole or metal clamp)
Termination: Terminal block or 6’’ [152mm] wire leads
Temp. Range: -65°F to +155°F [-54°C to +68°C]
Approvals: UL Recognized, CSA Certified, CE Compliant
Weight: 10 oz. [284g]
720-0001 24VAC/60Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads
720-0003 115VAC/60Hz, M3971/2-1 and M3971/2-5
720-0004 115VAC/60Hz, non-reset, 3-hole round, terminal block
720-0007 115VAC/60Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads
720-0008 115VAC/60Hz, non-reset, metal clamp, terminal block
720-0011 115VAC/60Hz, non-reset, metal clamp, 6’’ [152.4mm] wire leads
720-0012 115VAC/60Hz, front reset, 3-hole round, 6’’ [152.4mm] wire leads
720-0030 115VAC/50Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads
720-0031 230VAC/60Hz, non-reset, 3-hole round, terminal block
720-0036 230VAC/60Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads
Non-Reset / Terminal Block
2.44 [62.0]
3.23 [82.0]
2.66 [67.6] DIA
123456
2.14 [54.4]
DIA
Panel cutout: 2.16’’ [54.9] Dia.
Mounting holes: 0.125’’ [3.2] Dia. on 2.44’’ [62.0] B.C.
Rugged steel housing
Mil-spec
Control panels Industrial equipment Test equipment
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 722
72
Electromechanical Totally Sealed Hour Meter
722-0001 2-Hole Rectangular, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s
722-0002 Flush-Rectangular, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s
722-0003 Flush-Round, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s
722-0004 3-Hole Round, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s
5003-007S NEMA 4X, 12 Gasket kit and hardware for 3-Hole Round model (722-0004)
* All items are normally in factory stock
Models Description
Specifications
Features Options
Description
The Redington Model 722 provides an AC Hour Meter with an operating range of 90-240VAC (± 10%) 50/60 Hz. You no longer require two
separate meters, one for 115VAC and one for 230VAC. Models are available in the standard industry housings, 2-Hole Rectangular, Flush-
Rectangular, Flush-Round and 3-Hole Round. Models 722-0001 and 722-0002 fit a panel opening of 1.45" X 0.95" [36.8mm X 24.1mm]. The
Flush-Round Model 722-0003 and 3-Hole Model 722-0004 have a panel opening of 2.0" [50.6mm]. The Model 722 quartz time base insures
accurate long-term time keeping. The Totally Sealed case protects against the environment and provides years of reliable service. Model 722-
0004, 3-Hole mount, is NEMA 4X,12 rated when mounted with optional gasket.
Operating voltage 90-240VAC 50/60Hz
Totally sealed
UL/CSA Recognized, CE Compliant
6 Figure, 99999.9
Quartz accuracy
Wire leads
3-hole mount gasket kit (part# 5003-007S)
(for NEMA 4X, 12 rating)
Figures: 6 - digits, 0.125" [3.2mm] 99999.9
Hours - white on black
Tenths - red on white
Reset: Non-reset
Voltage: 90-240VAC (± 10%)
Frequency: 50/60Hz
Power: Less than 0.6 watts
Mounting: Clip or mounting holes
Termination: ¼” [6.3mm] spade terminals
Weight: 2 oz [57 g]
Accuracy: ± 0.02 over entire range
Case Material: Black polymer
Agency Approvals: UL/CSA Recognized, CE Compliant
Environmental: Totally sealed (all models)
Front Panel: Model: 722-0004, NEMA 4X, 12 rated
with optional gasket (part# 5003-007S)
Temperature: -40°F to +185°F [-40°C to + 85°C]
Vibration: 10-75 Hz @ 1 to 8g’s
www.redingtoncounters.com 73
Model 722 Electromechanical Totally Sealed Hour Meter
Applications
0.03 TO 0.63
[0.76 TO 16.00]
PANEL THICKNESS
0.92
[23.4]
1/4" [6.3] TERMINALS
2.15
[54.6]
2.82
[71.6]
1.77
[45.0]
1.41
[35.8]
0.19
[4.8]
1.25
[31.7]
0.06
[1.5]
0.91
[23.1]
0.69
[17.5]
1.43
[36.3]
MOUNTING
CLIP
0 0 0 0 00 0 0 0 0 0
Dimensions
0.92
[23.4]
1/4" [6.3] TERMINAL
2.15
[54.6]
2.82
[71.6]
1.75
[44.4]
2.12 [53.8]
1.41
[35.8]
0.19
[4.8]
1.25
[31.7]
0.06
[1.5] 2X Ø.15 [Ø3.8]
0.92
[23.4]
1.43
[36.3]
0.69
[17.5]
0 0 0 0 0
0 0 0 0 00 0 0 0 0 0
Medical Equipment Test Equipment Office Equipment
0.49 [12.5]
1/4" [6.3] TERMINAL
0.40 [10.2] MAX
PANEL THICKNESS
Ø2.33
[59.2] Ø1.99 [50.5]
0.22 [5.6]
1.50 [38.1]
1.53 [38.9]
1.69 [43.0]
0.69 [17.5]
MOUNTING
CLIP
0 0 0 0 00 0 0 0 0 0
Panel Opening: 2.0" [50.6]
Panel Thickness: 0.40 [10.2] Max. Panel Opening: 2.0" [50.6]
Panel Opening: 1.45" X 0.95" [36.8 X 24.1] Panel Opening: 1.45" X 0.95" [36.8 X 24.1]
Panel Thickness: 0.03 to 0.63 [0.76 to 16.00]
0.49 [12.5]
1/4" [6.3] TERMINAL
3X Ø.13 [Ø3.3]
3X Ø.15 [Ø3.8]
Ø2.44 [Ø62.0]
Ø2.54 [Ø64.5]
Ø2.80
[71.1]
3X 120˚0.22 [5.6]
Ø1.99
[50.5]
1.50 [38.1]
1.69 [43.0]
1.53 [38.9]
0.69 [17.5]
0 0 0 0 00 0 0 0 0 0
2-Hole
3-Hole RoundFlush-Round
Flush-Rectangular
www.redingtoncounters.com
Model 732
74
Electromechanical Totally Sealed Hour Meter
Models Description
Specifications
Features Options
Description
The Redington Model 732 provides a DC Hour Meter with an operating range of 10-80VDC. Models are available in the standard industry
housings, 3-Hole Round, Flush-Rectangular, Flush-Round and 2-Hole Rectangular. Models 732-0002 and 732-0004 fit a panel opening of 1.45"
X 0.95" [36.8mm X 24.1mm]. The Flush-Round Model 732-0003 and 3-Hole Model 732-0001 fit a panel opening of 2.0" [50.6mm]. Its quartz time
base insures accurate long-term time keeping. The Totally Sealed case protects against the environment and provides years of reliable service.
The 3-Hole Round housing is NEMA 4X,12 rated when mounted with optional gasket.
Operating voltage 10-80VDC
Totally sealed
UL/CSA Recognized, CE Compliant
6 Figure, 99999.9
Quartz accuracy
Wire leads
3-hole mount gasket kit (part# 5003-007S)
(for NEMA 4X, 12 rating)
Figures: 6 - digits, 0.125" [3.2mm] 99999.9
Hours - white on black
Tenths - red on white
Reset: Non-reset
Voltage: 10-80VDC
Power: 0.3 watts @ 12VDC
Mounting: Clip or mounting holes
Termination: ¼” [6.3mm] spade terminals
Weight: 2.0 oz [57 g]
732-0001 3-Hole Round, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s
732-0002 Flush-Rectangular, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s
732-0003 Flush-Round, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s
732-0004 2-Hole Rectangular, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s
5003-007S NEMA 4X, 12 Gasket kit and hardware for 3-Hole Round model (732-0001)
* All items are normally in factory stock.
Accuracy: ± 0.02 over entire range
Case Material: Black polymer
Agency Approvals: UL/CSA Recognized, CE Compliant
Environmental: Totally sealed (all models)
Front Panel: Model: 732-0001, NEMA 4X, 12 rated
with optional gasket (part# 5003-007S)
Temperature: -40°F to +185°F [-40°C to + 85°C]
Vibration: 10-75 Hz @ 1 to 8g’s
www.redingtoncounters.com 75
Model 732 Electromechanical Totally Sealed Hour Meter
Applications
Medical Equipment Outdoor power equipment Utility Vehicles
Dimensions
0.92
[23.4]
1/4" [6.3] TERMINAL
2.15
[54.6]
2.82
[71.6]
1.75
[44.4]
2.12 [53.8]
1.41
[35.8]
0.19
[4.8]
1.25
[31.7]
0.06
[1.5] 2X Ø.15 [Ø3.8]
0.92
[23.4]
1.43
[36.3]
0.69
[17.5]
0 0 0 0 0
0 0 0 0 00 0 0 0 0 0
0.49 [12.5]
1/4" [6.3] TERMINAL
3X Ø.13 [Ø3.3]
3X Ø.15 [Ø3.8]
Ø2.44 [Ø62.0]
Ø2.54 [Ø64.5]
Ø2.80
[71.1]
3X 120˚0.22 [5.6]
Ø1.99
[50.5]
1.50 [38.1]
1.69 [43.0]
1.53 [38.9]
0.69 [17.5]
0 0 0 0 00 0 0 0 0 0
0.49 [12.5]
1/4" [6.3] TERMINAL
0.40 [10.2] MAX
PANEL THICKNESS
Ø2.33
[59.2] Ø1.99 [50.5]
0.22 [5.6]
1.50 [38.1]
1.53 [38.9]
1.69 [43.0]
0.69 [17.5]
MOUNTING
CLIP
0 0 0 0 00 0 0 0 0 0
0.03 TO 0.63
[0.76 TO 16.00]
PANEL THICKNESS
0.92
[23.4]
1/4" [6.3] TERMINALS
2.15
[54.6]
2.82
[71.6]
1.77
[45.0]
1.41
[35.8]
0.19
[4.8]
1.25
[31.7]
0.06
[1.5]
0.91
[23.1]
0.69
[17.5]
1.43
[36.3]
MOUNTING
CLIP
0 0 0 0 00 0 0 0 0 0
Panel Opening: 2.0" [50.6]
Maximum Panel Thickness: 0.40 [10.2]
Panel Opening: 2.0" [50.6]
Panel Opening: 1.45" X 0.95" [36.8 X 24.1] Panel Opening: 1.45" X 0.95" [36.8 X 24.1]
Maximum Panel Thickness: 0.03 to 0.63 [0.76 to 16.00]
2-Hole
3-Hole RoundFlush-Round
Flush-Rectangular
www.redingtoncounters.com
Model 53
76
Electronic LCD Tachometer
The Model 53 Tachometers are self-powered by an internal lithium battery. They provide a low cost solution to accurately measure speed or
production rates for a number of manufacturing and process applications. A wide selection of inputs, dry contact closure, 3-30VDC or
20-250VAC/VDC, make the Model 53 adaptable to most applications. When used with the appropriate sensor, the unit can display units per
minute, length per minute or revolutions per minute. The maximum input rate is 10,000 counts per minute.
TERMINAL BLOCK WIRE LEADS
Figures: 4 LCD figures, 0.32” [8mm] high
Reset: Remote, manual, or non-reset
Speed: 10,000 counts/minute
Inputs: Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Power: Self-powered (internal lithium battery)
Mounting: Panel
Terminations: Terminal block, or connector -w/ 8’’ [200mm] wire leads
Battery Life: ~20years
Temperature:
Operating: -4°F to +140°F [-20°C to +60°C]
Storage: -40°F to +165°F [-40°C to +75°C]
Humidity: 0 to 95% RH, non-condensing
Vibration:
Operating: 10 to 55Hz, 0.01” [0.25mm] double amplitude
Non-Operating: 10 to 55Hz, 0.03” [0.75mm] double amplitude
Shock:
Operating: 10G
Non-Operating: 30G
Dielectric: 1000VAC 50/60Hz for 1 minute
Accuracy: Typically within 1% above 700Hz
Weight: 2 oz. [57g]
Approvals: UL Recognized, CSA Certified, CE Compliant
Lithium battery
Choice of non-reset or remote reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Termination
Case color
Private labeling
Mounting adapter plates
5003-001S - gasket
Description
Features Options
Specifications
Models
Dimensions
0.86 [21.8]
0.10 [2.5]
1.72 [43.7]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
0.86 [21.8]
0.10 [2.5]
1.58 [40.0]
1.02 [25.9]
1.47 [37.3]
1.92 [48.8]
* All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
5330-0000 X X X X X
5330-0001 X X X X X
5330-1000 X X X X X
5330-1001 X X X X X
5330-2000 X X X X X
5330-2001 X X X X X
5330-2200 X X X X X
5330-2201 X X X X X
Models Reset Input Speed/RPM Terminations Color
remote none manual switch 3-30VDC 20-250VAC/VDC 10,000 2500 term. block 8” wire leads Tan Black
www.redingtoncounters.com 77
Model 53 Electronic LCD Tachometer
Motor/pulley Speed
Applications
MOUNTING:
Unit Optional
Gasket Panel Clip
WIRING:
The mounting clip accommodates panel thicknesses up to 1/4”
[6.4mm].
Panel adapter plates are available in flush and 2 hole mount to fit
various panel cutouts. Consult the factory for availability.
Color code for the 8” [203mm] lead wires (24AWG) are:
1 - Yellow
2 - Blue
3 - Black
4 - Violet
5 - Gray
NOTES:
All resettable hour meters can be reset by a pulse with a minimum duration of 6 milliseconds.
SPECIAL WIRING OPTION
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option does not apply
for units with input of 20 - 250VAC/VDC or manual reset enable.
OPTIONAL INPUTS:
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
1.79 +/- 0.01
[45.5 +1/-0]
0.89 +/- 0.01
[22.6 +1/-0] Panel Cutout
Pin 1 not used
RESET
INPUT
20 - 250VAC/VDC
1 2 3 4 5
AC/DC AC/DC
RESET
INPUT
Pin 1 used for 0 - 10,000 RPM)
Pin 2 used for 0 - 2, 500 RPM)
3 - 30 VDC
1 2 3 4 5
+DC
+DC
Terminal block will accept wire sizes from 14 to 24AWG.
3 - 30VDC units are protected for transient voltages up to 50 volts
with pulse widths of up to 1 second at a 1% duty cycle (including
reverse polarity).
The operating AC frequency range is 40 to 400Hertz.
SWITCH (non-voltage)
RESET
INPUT
Pin 1 used for 0 - 10,000 RPM)
Pin 2 used for 0 - 2, 500 RPM)
1 2 3 4 5
Operating Instructions
www.redingtoncounters.com
Model 85
78
Electronic Modular Panel Meter
Description
Features Options
Specifications
The Model 85 is a 3 1/2 digit, Modular Digital Panel Meter, where input and output modules can be selected to suit multiple applications. Input
Modules are available to indicate Voltage, Amperage, Pressure, Temperature, Rate, Ohms and Frequency. User -friendly programming allows the
user to program scaling and set points. The Model 85 includes peak/valley (min/max) and password protection as standard features. The
housing is easy to mount and ensures a protection degree of IP 65. The Model 85 can be ordered with or without Program Lock.
Modular Panel Meter 3 1/2 digit
Optional bright red or green display
Multirange input modules reduce inventory
Popular 1/8 DIN mounting
Indicating or controlling current, voltage, resistance,
temperature, tachometer or frequency
Easily programmed
Optional password protection of programming
parameters
Data hold
Peak/valley (min/max) function
Programmable hysteresis and time delay
(up to 2 set points)
IP 65 front cover
General Specifications
Display: 7-segment LED, 0.55”
[14mm] high, (2 LED’s for
indication of relay ON). Min./
max. indication, -1999/1999
Over range indication: EE (under range: -EE)
Accuracy: See module specifications
Temperature drift: See module specifications
Scaling:
Electrical input range: Program within whole range
Display range: Program within whole range
Decimal point position: Programmable
Module Connection: Screw terminals
Environment:
Degree of protection: IP 65 (front)
Operating temperature: +32°F to +122°F [0°C to +50°C]
Humidity: R.H. <90% non-condensing
Storage temperature: +14°F to +140°F [-10°C to 60°C]
Humidity: R.H. <90% non-condensing
Weight: Approx. 12.4 oz [352g]
Housing:
Dimensions: 1.9” x 3.9” x 3.5” [48.3 x 99.1
x 88.9mm]
Material:
Housing: ABS/Polycarbonate blend
Front: Polycarbonate
Color: Black housing
Red front with red display
Gray front with green display
Approvals: UL, cUL, CE Compliant
Power Supply Specification
Power Supply AC: Over voltage cat.III
(IEC 60664)
Rated operational voltage: 230 VAC
+ 10%
115 VAC + 10%
48 VAC + 10%
24 VAC + 10%
Frequency: 50/60 Hz + 5 Hz
Voltage interruption: < 20ms
Rated insulation voltage: 250 VAC basic rms
Rated impulse withstand voltage: 6kV (1.2/50 msec)
IEC 60664-1
Power Supply DC:
Rated operational voltage: 12 to 48 VDC + 15%
Voltage interruption: < 10 ms (voltage =
10 VDC)
Rated insulation voltage: 150 VDC basic
Rated impulse withstand voltage: 4.0 kV (1.2/50 msec)
IEC 60664-1
Rated Operational Power: < 7 VA
ECM: Electromagnetic
compatibility
Immunity: Acc. to IEC 60801-4
Acc. to IEC 60801-5
Display color
Output type
Input voltage
Value to display or control
Program lock
79
www.redingtoncounters.com
Model 85 Electronic Modular Panel Meter
*Nominal voltage according to IEC 664-1. The measuring range
includes 15% tolerance to 690 V.
Accuracy
AC voltmeter 0.3% of reading + 3 dgt
DC voltmeter 0.2% of reading + 2 dgt
Temperature Drift
AC voltmeter + 150 ppm/°F + 0.2 dgt/°F
DC voltmeter + 100 ppm/°F + 0.05 dgt/°F
Ammeters DC (85KSCD/85KLCD)
AC (85KSCA/85LCA)
AC/DC (85KSAD/85KLAD)
Accuracy
AC ammeter 0.3% of reading + 3 dgt
AC ammeter (10 A) 0.5% of reading + 3 dgt
DC ammeter 0.2% of reading + 2 dgt
DC ammeter (10 A) 0.5% of reading + 2 dgt
Temperature Drift
AC ammeter + 150 ppm/°F + 0.5 dgt/°F
AC ammeter (2A,5A) + 200 ppm/°F + 0.1 dgt/°F
AC ammeter (10A) + 200 ppm/°F + 0.5 dgt/°F
DC ammeter + 100 ppm/°F + 0.05 dgt/°F
DC ammeter (2A,5A) + 200 ppm/°F + 0.5 dgt/°F
DC ammeter (10A) + 200 ppm/°F + 0.5 dgt/°F
Voltage Drop <200 mV (all ranges)
Input Specifications - Modules
Voltmeters DC (85KSVD/85KLVD)
AC (85KSVA/85KLVA)
Measuring
Range
Jumper
position
Range
Code
AC DC
Resolution Max.
Overload
199.9 mA
1999 mA
19.99 mA
199.9 mA
1999 mA
5.00 A
10 A DC
10 A AC
1-2
2-3
4-5
5-6
2-5
2-5
1-2(DC)
2-3(AC)
7
8
9
10
11
12
12
1
2
3
4
5
6
6
0.1 mA
1 mA
10 mA
0.1 mA
1 mA
10 mA
10 mA
10 mA
20 mA
100 mA
200 mA
500 mA
4 A
8 A
10 A
10 A
Measuring
Range
Jumper
position
Range
Code
AC DC
Resol-
ution
Input
Impedance
Max.
Overload
199.9 mV
1.999 V
19.99
199.9 V
600 V*
1-4
2-5
2-5
3-6
5-6
7
8
9
10
12
1
2
3
4
6
0.1 mV
1 mV
10 mV
0.1 V
1 V
100 KW
100 KW
1 MW
1 MW
1 MW
50 V
230 V
690 V
690 V
690 V
Ohmmeter (85KSIR/85KLIR)
Accuracy 0.2% of reading + 2 dgt
Temperature Drift + 150 ppm/°F + 0.1 dgt/°F
Tachometers (85KSTK/85KLTK)
* Pulses per revolution
Input Selection
Namur J1
NPN, PNP, Contact J2
Accuracy 1% of reading +5 dgt
Temperature Drift +200 ppm/°F
Input Impedance
Namur 1 kW
NPN, PNP, Contact 5 kW
Time Constant (tc) 1 sec.
Frequency Meters (85KSFQ/85KLFQ)
Input Selection
Namur J1,J4 and J6
NPN, PNP, Contact J2 and J5
600 VAC J3
Accuracy 1% of reading +5 dgt
Temperature Drift +200 ppm/°F
Input Impedance
Namur 1 kW
NPN, PNP, Contact 5kW
600 VAC 600 kW
Time Constant (tc) 1 sec.
Measuring
Ranges
Jumper
position
Range Code
AC
Resolution
199.9 W
1999 W
19.99 kW
199.9 kW
1-4
2-5
3-6
1-2
7
8
9
10
0.1
1
0.01 k
0.1 k
Measuring Jumper Range Resolution
199.9 RPM @ 30PPR*
199.9 RPM @ 60PPR*
199.9 RPM @ 100PPR*
1999 RPM @ 30PPR*
1999 RPM @ 60PPR*
1999 RPM @ 100PPR*
J4, 1-2
J5, 1-2
J6, 1-2
J4, 2-3
J5, 2-3
J6, 2-3
7
8
9
10
11
12
0.1 RPM
0.1 RPM
0.1 RPM
1 RPM
1 RPM
1 RPM
199.9 Hz
1999 Hz
J7
J8
7
8
0.1 Hz
1 Hz
Measuring
Ranges
Jumper
Position
Range
Code Resolution
Pressure Indicator
The Model 85 can be used to indicate pressure by using the
DC Amperage or DC Voltage input module. You can then program the
unit to limit the range to 20mA or 20VDC and progarm the engineering
units to display the corresponding pressure reading.
www.redingtoncounters.com
Model 85
80
Electronic Modular Panel Meter
Thermometers
Pt 100: RTD (85KSRT/85KLRT)
Pt 100, 1562°F/850°C (85KSPT/85KLPT)
Thermocouple type J (85KSJT/85KLJT)
Thermocouple type K (85KSKT/85KLKT)
Range Resolution Accuracy Temperature
Drift
-100.0 to 850 °C
-148 to 1562 °F
1 °C
2 °F
+ 0.2% of reading
+ 3 dgt
+0.4% of reading
+ 6 dgt
+ 150 ppm/°C
+ 0.05 dgt/°C
+ 180 ppm/°F
+ 0.10 dgt/°F
Range Resolution Accuracy Temperature
Drift
-100.0 to 760 °C
-148 to 1400 °F
1 °C
1 °F
+ 0.1% of reading
+ 4 dgt
+0.1% of reading
+ 8 dgt
+ 100 ppm/°C
+ 0.05 dgt/°C
+ 180 ppm/°F
+ 0.10 dgt/°F
Range Resolution Accuracy Temperature
Drift
-100.0 to 199.9 °C
-148 to 199.9 °F
-148 to 392 °F
0.1 °C
0.2 °F
1 °F
+ 0.2% of reading
+ 2dgt
+0.2% of reading
+ 4 dgt
+0.2% of reading
+ 4 dgt
+ 150 ppm/°C
+ 0.05 dgt/°C
+ 180 ppm/°F
+ 0.10 dgt/°F
+ 180 ppm/°F
+ 0.10 dgt/°F
Range Resolution Accuracy Temperature
Drift
-100.0 to 1250 °C
-100 to -50 °C
1 °C
1 °C
+ 3% of reading
+ 3 dgt
+1% of reading
+5/-1 dgt
+ 100 ppm/°C
+ 0.05 dgt/°C
+ 100 ppm/°C
+ 0.05 dgt/°C
-50.0 to 780 °C
780 to 1250 °C
1 °C
1 °C
+ 0.1% of reading
+ 3 dgt
+0.25% of reading
+1/-3 dgt
+ 100 ppm/°C
+ 0.05 dgt/°C
+ 100 ppm/°C
+ 0.05 dgt/°C
-148.0 to 1999 °F
-148 to -58 °F
2 °F
2 °F
+ 3% of reading
+ 6 dgt
+1% of reading
+10/-2 dgt
+ 180 ppm/°F
+ 0.10 dgt/°F
+ 180 ppm/°F
+ 0.10 dgt/°F
-58.0 to 1436 °F
1436 to 1999 °F
2 °F
2 °F
+ 0.1% of reading
+ 6 dgt
+0.25% of reading
+2/-6 dgt
+ 180 ppm/°F
+ 0.10 dgt/°F
+ 180 ppm/°F
+ 0.10 dgt/°F
Output Specifications - Modules
Relay Outout 1 or 2 Relays (85KSR1/85KSR2)
Power Supply Supplied by main unit
Output 1 or 2 SPDT relays
Rated Insulation Voltage 250 V basic RMS
Contact Ratings (AgCdO)
Resistive AC 1 5A, 250 VAC
DC 1 5A, 24 VDC
Small inductive AC 11 2A, 250 VAC
loads DC 11 3A, 24 VDC
Mechanical Life > 40 x 106 operations
Electrical Life > 105 operations (at max load)
Operating Frequency max. 10Hz (50% duty cycle)
Dielectric Strength
Dielectric voltage 2 kVAC (rms)
Rated impulse withstand 4 kV (1.2/50ms)
voltage
Excitation Output (85KSDC)
Power Supply Supplied by main unit
Output Voltage
12 VDC: jumper position 3-6 tolerance +20%
24 VDC: jumper position 1-4 tolerance +20%
Output Current
12 VDC < 35 mA DC
24 VDC < 20 mA DC
EMC Electromagnetic compatibility
Immunity Acc. to IEC 60801-4
Acc. to IEC 60801-5
Analog output (85KSAN)
Temperature Drift +200 ppm/°C
Short-Circuit Protection yes
Analog Output Porportional to Input Signal.
low input signal = low analog output
high input signal = high analog output
Time Constant 1 sec.
NPN Output 2 Transistor Outputs (85KSNP)
NPN Open Collector: ISNK = 100mA max. @ VOL = 1.0 VDC max.
VOH = 30 VDC max.
12VDC/+15%, 40 mA,
voltage output is provided
Measuring
Range
Load
Resistance Accuracy
0 to 20 mA
4 to 20 mA
0 to 10 V
< 500
< 500
< 1,000
+1% of reading +0.1 mA
+1% of reading +0.1 mA
+1% of reading +0.05 V
81
www.redingtoncounters.com
Model 85 Electronic Modular Panel Meter
PV
SP -Hyst
SP
SP +Hyst
UP/ND
UP/NE
DO/ND
DO/NE
Delay
Delay
Delay
Delay
Delay
Delay
Output activates as input signal rises above setpoint (High Alarm)
Output activates as input signal drops below setpoint (Low Alarm)
Setpoint Operation
1999
-1999
HiE
LOE
0
1999
-1999
0
HI
LO
EE
-EE
See
Formula
Below
Electrical Input Range Display Range Display Indication
Formula
(HI - LO) * (Xin - LOE)
(
HiE - LOE
)
+LO
Scaling Operation
Operation Diagrams Mode of Operation
Depending upon the input modules used, it is possible to measure
current, voltage, or resistance ...etc. The range is selected with a
jumper on the input module and programming. Without an output
module the Model 85 is an indicator - by inserting an output
module the Model 85 is a controller.
The input range and the display range are fully programmable, and
so are the setpoint(s) if a relay output module is inserted.
A hold function is available for freezing a measured value. Pass-
words 0 to 99 are for overall programming with passwords 100 to
199 allow direct setpoint programming outside the password
protection. See user manual for futher details.
Overall Dimensions
Front View
SV
12
3.78" [96mm]
1.89"
[48mm]
REDINGTON
2
3
14
SideView
3.24" [82.2mm]
Max. 0.47" [12.0mm]
Max. 0.32" [8.2mm]
Panel Cutout 1.77” [45mm] X 3.62” [92mm]
Cutouts can be up to .02” [0.5mm] larger
Operation Details
www.redingtoncounters.com
Model 85
82
Electronic Modular Panel Meter
Slot
#3
Slot
#4
Rear view of main unit
!
*)
IN LO
IN HI
0.2/2V
IN HI
20/200/
600V ~
~
!
*)
+ EXC
- EXC
12/24 VDC
!
*)
A 2 -
12 - 48 VDC
A 1 +
HOLD
!
*)
AC1.5A,250V~
15
18
16
m
Input Module:
VAC
VDC
AAC
ADC
10A AC/DC
W
PT 100
J-type Thermocouple
K-type Thermocouple
Tachometer
Frequency
Output
Modules:
12 VDC Excitation
24 VDC Excitation
or
Analog output
0-20 mA
4 - 20 mA
0 - 10 VDC
Power Supply
Modules:
(Requires 2 slots)
24 VAC
48 VAC
115 VAC
230 VAC
12 - 48 VDC
Relay Output
Modules:
1 SPDT(Form C),
5A
2 SPDT(Form C),
5A
2 NPN
Slot
#1
Slot
#2
Slot
#5
Red or Green Display Unit
Interchangeable Engineering Unit Labels
Blank Rear Inserts
Gasket
Mounting Adapter
Input Module
Output Module
Power Supply
Module
Relay/NPN
Output Module
Rear View Assembled Unit
Module Slot Identification:
Each module is clearly marked with a diagram showing which slot it should
be inserted in.
Slot 1
Slot 2
Slot 3 & 4
Slot 5
83
www.redingtoncounters.com
Model 85 Electronic Modular Panel Meter
Ordering Information
Component Selection - Part Number
To order assembled (built-up) panel meters, see following “Part Number Selection” section.
To order components, select modules from each of the categories below to construct an Indicator or Controller. For additional guidance, consult the
flowchart on the right.
Ordering w/Program
Number Lock
Main Unit
Red Display (standard red) 85KSRD
Red Display (high efficiency red) 85KSHR
Green Display 85KSHG
Power Supply Modules
12 to 48 VDC 85KSP1
24 VAC 85KSP2
48 VAC 85KSP3
115 VAC 85KSP4
230 VAC 85KSP5
Input Modules
DC Voltage 85KSVD 85KLVD
AC Voltage 85KSVA 85KLVA
DC Amperage 85KSCD 85KLCD
AC Amperage 85KSCA 85KLCA
AC/DC Amperage (10A) 85KSAD 85KLAD
Resistance (Ohms) 85KSIR 85KLIR
PT 100 RTD (can be scaled to °F) 85KSRT 85KLRT
PT 100 RTD (up to 1562°F/850°C) 85KSPT 85KLPT
J-Type Thermocouple (can be scaled to °F) 85KSJT 85KLJT
K-Type Thermocouple (can be scaled to °F) 85KSKT 85KLKT
Tachometer 85KSTK 85KLTK
Frequency 85KSFQ 85KLFQ
Output Modules (optional)
1 Relay 85KSR1
2 Relays 85KSR2
2 NPN Transistors 85KSNP
*12/24 VDC Excitation Output/for sensor supply 85KSDC
*Analog Output 85KSAN
*Analog and excitation output modules occupy the same plug-in location, therefore only
one selection is possible.
*Items in bold are normally in factory stock.
INDICATOR
DISPLAY
COLOR?
POWER
SUPPLY?
INPUT
TYPE?
END
DISPLAY
COLOR?
POWER
SUPPLY?
INPUT
TYPE?
CONTROLLER
**
ANALOG
OR
EXCITATION
OUTPUT?
ANALOG
OUTPUT
SIGNAL?
EXCITATION
OUTPUT
VOLTAGE?
OUTPUT?
END
** It is possible to construct
an indicator with an
excitation or analog output
Component Selection Flowchart
To build an indicator, choose display color, power supply, and
input module. For a controller, also choose an analog/excitation
output and/or output module.
Applications
Temperature Volts/Amps/Ohms Speed Control
www.redingtoncounters.com
Model 85
84
Electronic Modular Panel Meter
Ordering Key
Model Number
Input Type and Range Code
DC Ammeters
CD1 -199.9 to + 199.9 mA
CD2 -1.999 to +1.999 mA
CD3 -19.99 to +19.99 mA
CD4 -199.9 to +199.9 mA
CD5 -1999 to +1999 mA
CD6 -5.00 to +5.00 A
CD7 -10.00 to +10.00 A
AC Ammeters
CA1 0 to 199.9 mA
CA2 0 to 1.999 mA
CA3 0 to 19.99 mA
CA4 0 to 199.9 mA
CA5 0 to 1999 mA
CA6 0 to 5.00 A
CA7 0 to 10.00 A
DC Voltmeters
VD1 -199.9 to +199.9 mV
VD2 -1.999 to +1.999 V
VD3 -19.99 to +19.99 V
VD4 -199.9 to +199.9 V
VD5 -600 to +600 V
AC Voltmeters
VA1 0 to 199.9 mV
VA2 0 to 1.999 V
VA3 0 to 19.99 V
VA4 0 to 199.9 V
VA5 0 to 600 V*
Thermometers
J-Type TC:
JC1 -100 to 760°C
JF1 -148 to 1400°F
K-Type TC
KC1 -100 to 1250°C
KF1 -148 to 1999°F
PT100 RTD
PC1 -100.0 to 199.9 °C
PF1 -100 to 850°C
PC2 -148.0 to 199.9°F
PF2 -148 to 392°F
PF3 -148 to 1562°F
Ohmmeters
RO1 0 to 199.9 W
RO2 0 to 1.999 kW
RO3 0 to 19.99 kW
RO4 0 to 199.9 kW
Frequency Meters
Namur Inputs
FO1 5.0 to 199.9 Hz
FO2 10.0 to 1999 Hz
NPN, PNP or
Contact Input
FS1 5.0 to 199.9 Hz
FS2 10.0 to 1999 Hz
NPN, PNP or
600 VAC Input
F61 5.0 to 199.9 Hz
F62 10.0 to 1999 Hz
Tachometer
NAMUR Input
TA1 8.0 to 199.9 RPM @ 30PPR
TA2 5.0 to 199.9 RPM @ 60PPR
TA3 2.0 to199.9 RPM @ 100PPR
TA4 20 to 1999 RPM @ 30PPR
TA5 10 to 1999 RPM @ 60PPR
TA6 120 to 1999 RPM @ 100PPR
NPN, PNP or Contact Input
TB1 8.0 to 199.9 RPM @ 30PPR
TB2 5.0 to 199.9 RPM @ 60PPR
TB3 2.0 to 199.9 RPM @ 100PPR
TB4 20 to 1999 RPM @ 30PPR
TB5 10 to 1999 RPM @ 60PPR
TB6 10 to 1999 RPM @ 100PPR
* Nominal voltage according to
IEC60-664-1. The measuring
range includes 15% tolerance
equal to 690 V.
Part Number Selection - Assembled Unit(s)
Note: There is a 10 piece minimum of various assembled meters, not one specific part number. 8 5 xxxxxxx x x x
Model 85
Power Supply
1) 12-48 VDC 2) 24 VAC 3) 48VAC 4) 115 VAC5) 230 VAC
Relay Output
N) None 1) One Relay 2) Two Relays 3) NPN
Output Modules
N) None 1) 0-20mA 2) 4-20mA 3) 0-10 VDC 4) 12 VDC Excitation
5) 24 VDC Excitation
Display Color
R) Red G) Green H) High Efficiency Red
Hardware Lock of Programming
S) None L) Program Lock
Engineering Label
01 to 47 (see front panel description #4)
85
www.redingtoncounters.com
Model 88 Electronic LCD Programmable Indicator/Controller
Description
Features Options
The Model 88 is a family of LCD Indicators/Controllers, with eight 7-segment digits that are 0.35" [9mm] in height. The standard display is a
backlit LCD, providing red characters on a dark background. An optional reflective LCD with dark characters on a light background is available.
Unit programming is accomplished using four front-panel switches, or programming can be done using the optional serial data interface and
dedicated PC-based software (Redi-Ware), which is available from Redington free of charge. Upon power up, the Indicator/Controller performs
internal diagnostics and flashes all segments of the display “ON” and “OFF” several times. The Indicator/Controller then configures itself per
previous programming, loads the internal Counters and Timers with their values prior to power down, and begins normal operation.
The Model 88 Indicator/Controller is capable of receiving counts and/or analog inputs, processing those inputs in a number of different selectable
ways, and then providing outputs in several formats. Base units, i.e.; #8800-0000, or similar units can be programmed for Elapsed Time, Rate,
Preset Count/Time, count Add/Add, count Add/Sub., or count Quadrature. The two independent control outputs are open-collector (NPN) outputs
that can be controlled by either count inputs, time, the analog input, or combinations of the analog input/time and count inputs. Based on two
inputs, the indicator is capable of displaying two counts, a rate indicator and an elapsed time at the same time. The base unit provides the display,
programming, and processing functions for the final configuration as well as the counter I/O function. I/O functions and factory installed modules
are available that allow the user to configure complex functions into a small enclosure. Other models add analog input/output functions to the base
unit, and serial communication functions, which supports RS232/RS422/RS485, providing the user with a broad selection of configurations.
Each Model 88 base unit is normally powered from a DC voltage of +10V to + 32 V. However, an AC power supply module # 200557-002S can be
attached to the rear of the unit that converts +90VAC to +250VAC, to +12VDC, which can be used to power the Model 88 and an external sensor.
Another module, 200557-001S, can be added that converts the discrete outputs of the Model 88 base unit to relay contacts.
Dual up counting
Preset of time, rate or count
Directional counting
1,2,4x quadrature
Add/add counting
Add/subtract counting
Rate indication on count inputs
Analog ranges: 0 to 10 VDC or 4 to 20 mA
Prescaling of analog inputs and counts
Elapsed timer function available for all modes of operation
NEMA 4X/IP56 sealed panel
UL, cUL Recognized, CE Compliant UL file # E19514
Relay Module 200557-001S
2 form C, 5 amp relays
Serial Comm. (RS232, RS422, RS485)
Analog input/outputs
Display color
AC Power Module 200557-002S
+90 VAC to +285 VAC, 50/60 Hz (unit is
normally powered from +10 VDC to +32 VDC)
Specifications
Display: LCD, 8 digits, 0.35" [9mm] negative image transmis-
sive red or positive image reflective display. In the
negative count mode the display will be 7 digits with a
“-” sign. (Reflective display recommended in sunlight)
Annunciators: A, B, R, 1, 2 ANLG, LOCK, HZ, RPM, HRS, SEC.
0.039’’ [1mm]
Programming: Programming is accomplished through the front panel
switches or by serial data interface and dedicated PC
software, supplied by Redington Counters, Inc.
Available
Functions: Totalizer
Directional Counting
Rate/Count
Three different quadrature resolutions
Add-Add
Add-Subtract
Dual Count
Elapsed Time
Analog Input
Predetermining
Predetermining
Functions: Preset units provide two discrete outputs which can
be controlled as a function of count, rate, elapsed
time, or analog input. Each control output can be set
by any of the four functions and reset by the same or
a different function. For example, control output 1
could be set when a specific count is reached and
reset when an analog input level is reached.
www.redingtoncounters.com
Model 88
86
Electronic LCD Programmable Indicator/Controller
Predetermining Timer:
Programmable Ranges:
Hours
Seconds
Hours, Minutes & Seconds
Programmable Decimal Point:
Counter A: 4 decimal point locations may be selected.
Counter B: 4 decimal point locations may be selected.
Rate Display: 4 decimal point locations may be selected.
Analog Input: 4 decimal point locations may be selected.
Time: 4 decimal point locations may be selected.
Power Requirements:
Base unit: +10VDC TO +32VDC @ 50mA max.
Relay Module: Model 200557-001S; +10VDC to +32VDC @ 50mA,
max.
AC Power Supply: Model 200557-002S; +90VAC to +250 VAC 50/60 Hz
@ 6 VA max.
Memory: Nonvolatile EEPROM retains all program parameters
and values when power is removed. EEPROM
provides 20 year data retention.
Sensor Power: +12VDC @ 100mA, minimum (200557-002S Module)
Front Panel Lockout:
Two front panel lockouts are available. In the
programming mode, the operator is prohibited from
entering new parameters. In the operating mode, the
lockout disallows manual reset of any displayed
inputs.
Count/Timer Inputs (Input A & Input B):
Software selectable: switch contact or voltage input
Software Selectable: filter: no filter or 160 Hz 1st order
L.P.
Voltage Mode VIH: 2.4VDC, min.
Voltage Mode VIL: 0.8VDC, max. or open circuit
Switch Mode VIH: 2.4 VDC, min. or open circuit
Switch Mode VIL: 0.8VDC, max.
Maximum Input voltage: 32.0VDC
Minimum Input voltage: -0.8VDC
Counter/Timer Operational Format:
Input A is used for all count functions
Input B is used for timer enable and all dual Input
counter functions (i.e. ADD/ADD, ADD-SUB,
DIRECTIONAL COUNT, QUADRATURE, and DUAL
COUNT).
Input Scaling: A & B Counters and analog input, (- 9.9999 to
99.9999)
Quadrature Counting:
Software selectable X1, 2, 4
Analog Input: 0 to 10VDC or 4 to 20 mA
Resolution: 4 digit
Input Impedence:
150K ohms, for 0 to 10VDC
100 ohms, for 4 to 20 mA
Max. Count Rate: 40 KHz for single counter mode.
20 KHz for dual count modes
Rate Input Units: The rate input can be expressed in terms of scaled
counts per minute (rP) or scaled counts per second
(HZ) of counter A.
Rate Indicator Accuracy:
±0.01%, References Time Base @T=25°C
Minimum Input Frequency:
1 pulse in 10 seconds
Maxium Input
Frequency: 40 K HZ
Reset Functions: (Automatic & manual)
Reset-to-Zero: Can be programmed so that the output activates
when counter equals the preset value, counter
returns to zero when reset.
Reset-to-Preset: Can be programmed so that the output activates
when counter equals zero, Counter returns to
Preset value when reset.
Resets: Automatic or manual.
Outputs: Base unit; Solid-state NPN: (2) Open
collector:ISNK=100mA @VOL=1.1VDC VOH=40VDC
Relay Module: Model 200557-001S; 2 form “C” relays rated @ 5
amps 250 VAC, 30VDC(resistive load) 1/10th HP
@120VAC (inductive load)
Relay Life Expectancy:
100,000 cycles min. @ max. rated load.
Programmable Timed Outputs:
Both control outputs can be timed.
Elapsed Timer Accuracy: ± 0.01% @T=25°C
Analog Output: 0 TO 10VDC OR 4 TO 20mA
Accuracy: 0.25% of full scale @ T = 25°C
Resolution: 14 bits
RS232/RS485/RS422 Serial Communications: (Optional)
Baud Rate: Selectable 2400, 4800, 9600, or 19.2K
Data Length/Parity/Stop Bits: 8n1
RS485 Address: Programmable from 0 to 99.
Transceiver Loading: RS232/RS485/RS422- up to 16 loads
Certifications & Compliances:
UL, cUL- Recognized Component, file # E 195514
CE-Compliant to EN 61326: 1998 for industrial
equipment
Environmental Conditions:
Operating Temperature: -4°F to +140°F [-20°C to +60°C]
Storage Temperature: -40°F to +185°F [-40°C to +85°C]
Operating & Storage Humidity: to 95% (non-condensing) from -4°F
to +140°F [-20°C to +60°C]
Altitude: Up to 6561Ft. (2000 Meters)
Electrical Connection: Wire clamping screw terminals
Construction:
High impact black plastic case with “Clip” type mount.
Front panel meets NEMA 4X/IP65 requirements for
indoors use, when properly installed. Oversized front
panel flange insures proper sealing of panel cutouts.
Gaskets for front panel are provided.
Panel Thickness: 0.05" to 0.20" [1.3 to 5.1mm]
Weight: Less than 3 oz. (85g)
87
www.redingtoncounters.com
Model 88 Electronic LCD Programmable Indicator/Controller
Models Description
Dimensions
Applications
For Models and Descriptions see the Ordering Information section
1.62 [41.1] 1.25 [31.8]
2.96 [75.2]
2.59 [65.8] 0.13 [3.2]
3.21 [81.7]
4.33 [109.9]
Model 88
Panel Cutout 2.63’’ to 2.605’’ x 1.28’’ to 1.26’’ [66.8 to 66.2 x 32.5 to 32.0]
Max. thickness of panel 0.5’’ [12.7]
Batching Cut-to-length Elapsed time indicator
Flow and level control Rate/Indication or control
www.redingtoncounters.com
Model 88
88
Electronic LCD Programmable Indicator/Controller
DISPLAY DISPLAY ANALOG ANALOG RS-485
MODEL RED REFLECTIVE INPUT OUTPUT RS-232
NUMBER DESCRIPTION TRANSMISSIVE RS 422
8800-0000 Base unit, Red Trans., 10-30VDC, Prescale X
8810-0000 Base unit, Reflective, 10-30VDC, Prescale X
8800-0100 Red Trans., 10-30VDC, Prescale, Serial Communications X X
8810-0100 Reflective, 10-30VDC, Prescale, Serial Communications X X
8800-0010 Red Trans., 10-30VDC, Analog input, Prescale X X
8810-0010 Reflective, 10-30VDC, Analog input, Prescale X X
8800-0001 Red Trans., 10-30VDC, Analog output, Prescale X X
8810-0001 Reflective, 10-30VDC, Analog output, Prescale X X
8800-0110 Red Trans., 10-30VDC, Analog input, Prescale, Serial Communications X X X
8810-0110 Reflective, 10-30VDC, Analog input, Prescale, Serial Communications X X X
8800-0101 Red Trans., 10-30VDC, Analog output, Prescale, Serial Communications X X X
8810-0101 Reflective, 10-30VDC, Analog output, Prescale, Serial Communications X X X
8800-0011 Red Trans.,, 10-30VDC, Analog I/O, Prescale X X X
8810-0011 Reflective, 10-30VDC, Analog I/O, Prescale X X X
8800-0111 Red Trans, 10-30VDC, Analog I/O, Prescale, Serial Communications X X X X
8810-0111 Reflective, 10-30VDC, Analog I/O, Prescale, Serial Communications X X X X
ACCESSORIES
200557-001S Relay module 2 form C relays
200557-002S AC Voltage module, +90VAC to +250VAC also outputs +12VDC for base unit & sensor
Ordering Information
Note: Reflective display is recommended for applications that will be
exposed to direct sunlight
* All parts are normally in factory stock.
89
www.redingtoncounters.com
Model 83 Electronic LCD Predetermining Counter
The 83 Counter features a 7 segment, 2 lines by 6-digit backlit LCD display. The main display line is red and shows the count value or the batch/
total value when preset 3 or output 3 is viewed in the secondary display. The smaller secondary display line is green and can be used to view the
prescaler value, preset values, output count values or batch/total count values (batch model only).
The 83 Counter offers a choice of nine programmable counting modes for use in applications requiring bidirectional, anti-coincidence, and
quadrature counting. The unit may be programmed to detect counts on both edges of the input signal resulting in a doubling of frequency. DIP
switches are used for input configuration setup and to provide a program disable function.
Four front panel push buttons are used for ease of programming the operating modes and data values, to change the viewed display, and
performing user programmable functions, e.g. reset, etc. The 83 Counter can be configured for one of two numeric date entry methods.
Digital - The digital entry allows for the selection and incrementing of digits individually.
Automatic Scrolling - This method allows for the progressive change of one through all digits positions by pressing and holding the up or down
button.
Protection of data value and unit configuration - The program disable DIP switch, a user-programmable code value, and an external user input
selected for program disable can be utilized to provide multilevel protection.
The standard with dual presets is available with solid-state and relay outputs. The batch counter has relay outputs for output 2 and the batch/total
output 3, with output 1 available as solid-state. For all 83 Counters, the solid-state outputs are available in a choice of NPN current sinking or PNP
current sourcing, open- collector transistor outputs. All relay output boards are field replaceable.
Prescaler output is available as a dual preset, with solid-state outputs. The prescaler output is useful for providing a lower frequency scaled pulse
train to a PLC or another external totalizer. The prescaler output provides a programmable width for every count or every 10 counts registered on
the display
RS485 communications - optional serial communication capability allows for interrogation and modification of the preset, count and prescaler
values.
Construction - The unit is made of lightweight, high impact plastic with a textured front panel and a clear display window. The front panel meets
NEMA4X/IP65 specifications when properly installed. Multiple units can be stacked horizontally or vertically. SMT, extensive testing, plus high
immunity to noise interference make the 83 Counter extremely reliable in industrial environments.
Quadrature sensing
Bidirectional counting, up/down control
Count values to (999999)
Prescaler output model (dual preset only)
Field replaceable relay output boards
Solid State and relay output models
NEMA4X/IP65 sealed bezel
Status indicators for outputs
Security via programmable operator access
privileges and protected values menu
Programmable user inputs and front panel
function key
Horizontal or vertical stacking of multiple units
85 to 250VAC or 18 to 36VDC/24 VAC power units
RS485 communications option
Choice of numeric data entry modes
Description
Features Options
Output type
Serial communications
Voltage input
Display color
Number of presets
www.redingtoncounters.com
Model 83
90
Electronic LCD Predetermining Counter
Display: 2 line by 6 digits LCD display, negative image
transmissive with RED (top line) and GREEN
(bottom line) backlighting. Positive image reflective
display units are non-stock available.
Main: 0.3" (7.6mm) high digits
Secondary: 0.2" (5mm) high digits
Annunciators:
Value: PRS, 1,2 and 3
Output: 01, 02 and 03
POWER REQUIREMENTS:
AC Versions
AC Power: 85 to 250 VAC, 50/60Hz, 9VA max.
DC Power: 11 to 14 VDC @ 159 mA max.
(Non PNP output models)
Note: Models with PNP current sourcing outputs must be powered from
AC
DC Versions
DC Power: 18 to 36 VDC: 5.5 W max.
AC Power: 24 VAC +/- 10%: 50/60 Hz: 7VA max.
Note: The 10% tolerance range on AC input voltage must be strictly
adhered to DO NOT EXCEED 26.4 VAC
PEAK (START-UP CURRENT)
AC or DC Power: 500mA peak start-up current for 10 msec.
max.
DC OUT/ VSCR IN-terminal 10
For units that do not have PNP current sourcing outputs, this terminal
provides a DC output for sensor power + 12 VDC (+/- 15%). The
maximum sensor current is 100mA.
For units with PNP current sourcing outputs this terminal serves a dual
purpose depending on the application PNP output voltage level and
current requirements.
1. The terminal may be used as a +12 VDC output for sensor
power. In this case, the PNP output voltage level will be
+12 VDC (+/-15%). A maximum of 100 mA is available for
the combination of sensor and PNP output sourcing
current.
2. If a higher PNP output voltage level or additional output
sourcing current is needed, an external DC supply may be
connected between the “DC OUT ( V SRC IN)” and
“COMM.” terminals. This supply will determine the PNP
output voltage level, and must be in the same range of +13
to +30 VDC.
An external DC supply can also provide the additional
output sourcing current required in applications where
two or more PNP outputs are “ON” simultaneously.
However, the maximum current range of 100mA per
individual output must not be exceeded, regardless of
external supply capacity.
3. Memory: Nonvolatile FRAM retains all program parameters and
count values.
4. SENSOR POWER: + 12 VDC (+/- 15%) @ 100mA max.
5. COUNT INPUTS A & B: Accepts count pulses from a variety of
sources, DIP switch selectable.
Current Sourcing: (active high): Vinmax. = 3.9K ohm pull-down
to 30 VDC.
Current Sinking: (active low): 7.8 K ohm pull-up to 12 VDC :
Isnk = 1.8mA max.
Debounce : 50 Hz
Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min.
Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min.
6. MAX. COUNT RATE: Model dependent. All listed values are in Khz.
Note: Max. count rates for X2 & X4 modes are given for 50% duty
cycle signals and quad signals with 90° phase shift.
Prescaler C1-Usr C2-usr *Ad-sub QUAD
Value C1-Ud C2-Ud Ad-Ad X1 X2 X4
0.00001-0.99999 8.3 4.1 8.6 4.5 4.1 2.1
1.00000 11.5 5.7 11.5 6.0 5.8 3.0
1.00001-2 6.5 3.2 6.6 4.0 3.2 1.6
2.00001-3 5.0 2.4 5.2 3.4 2.5 1.3
3.00001-4 4.1 2.0 4.4 2.8 2.0 1.0
4.00001-5 3.4 1.7 3.8 2.5 1.7 0.8
5.00001-6 2.9 1.4 3.2 2.2 1.4 0.7
6.00001-7 2.7 1.3 2.8 2.0 1.3 0.6
7.00001-8 2.2 1.1 2.4 1.8 1.2 0.6
8.00001-9 2.2 0.9 2.3 1.6 1.1 0.5
9.00001-9.99999 1.9 0.9 2.0 1.5 0.9 0.4
Dual Preset Model 8302
Prescaler C1-Usr C2-usr *Ad-sub QUAD
Value C1-Ud C2-Ud Ad-Ad X1 X2 X4
0.00001-0.99999 8.3 4.1 8.4 3.7 3.6 2.2
1.00000 11.4 5.5 11.8 4.3 4.2 3.0
1.00001-2 6.5 3.2 6.6 3.2 3.0 1.6
2.00001-3 5.0 2.5 5.4 2.8 2.5 1.3
3.00001-4 4.1 2.0 4.2 2.4 2.0 1.0
4.00001-5 3.4 1.7 3.8 2.1 1.7 0.8
5.00001-6 2.9 1.4 3.2 1.9 1.5 0.7
6.00001-7 2.7 1.3 2.8 1.7 1.3 0.6
7.00001-8 2.4 1.1 2.6 1.6 1.2 0.6
8.00001-9 2.2 1.1 2.4 1.5 1.1 0.5
9.00001-9.99999 1.9 0.9 2.2 1.4 1.0 0.4
Batch Model 8303
With Counter 2 configured as a Batch Counter (C2 A5n = bAtch)
Prescaler C1-Usr C2-usr *Ad-sub QUAD
Value C1-Ud C2-Ud Ad-Ad X1 X2 X4
0.00001-0.99999 6.2 N/A N/A N/A N/A N/A
1.00000 8.0 N/A N/A N/A N/A N/A
Prescaler Output Model 8304
* Inputs A & B rates summed.
Prescaler C1-Usr C2-usr *Ad-sub QUAD
Value C1-Ud C2-Ud Ad-Ad X1 X2 X4
0.00001-0.99999 6.5 3.3 6.6 3.5 3.3 1.6
1.00000 8.5 3.6 8.6 4.0 4.0 2.1
Batch Model 8303
With Counter 2 configured as a Total Counter (C2 A5n = totAL)
Single Preset Model 8301
Prescaler C1-Usr C2-usr *Ad-sub QUAD
Value C1-Ud C2-Ud Ad-Ad X1 X2 X4
0.00001-0.99999 8.4 4.1 9.4 5.4 4.5 2.1
1.00000 12.0 5.9 12.4 6.5 6.0 3.0
1.00001-2 6.6 3.2 6.8 4.3 3.3 1.6
2.00001-3 5.3 2.6 5.6 3.7 2.6 1.3
3.00001-4 4.3 2.1 4.6 3 2.2 1.1
4.00001-5 3.6 1.8 3.8 2.7 1.8 0.9
5.00001-6 3.1 1.5 3.4 2.4 1.6 0.8
6.00001-7 2.8 1.4 3.2 2.1 1.4 0.7
7.00001-8 2.6 1.3 2.8 1.9 1.3 0.6
8.00001-9 2.3 1.1 2.4 1.8 1.1 0.5
9.00001-9.99999 2.1 1.0 2.3 1.7 1.1 0.5
91
www.redingtoncounters.com
Model 83 Electronic LCD Predetermining Counter
7. USER INPUTS: Configurable as current sinking (active low), or
current sourcing (active high) inputs via a single plug
jumper.
Current Sinking: (active low) : VIL= 1.5 VDC max. 22 K
ohm pull-ups to 5 VDC
Current Sourcing: (active high): VIH =3.5 min. VIN max. =
30 VDC; 22K ohm pull-down.
Response Time: 10 msec. max.
Inhibit Response Time: 250 microsec max.
8. OUTPUTS: (Output type and quantity model dependent)
Solid-State:
NPN Open Collector: ISNK= 100mA max. @ VOL = 1.1 VDC
max. ;VOH= 30 VDC max.
PNP Open Collector: ISRC = 100mA max. ( See note) ; VOH =
12 VDC +/-15% ( using internal supply);
VOH = 13 to 30 VDC ( using external
supply).
Note: The internal supply of the 83 counter can provide a total
of 100 mA for the combination of sensor current and PNP
output sourcing current. The supply voltage is +12 VDC (+/-15
%), which will be the PNP output voltage level when using only
the internal supply.
If additional PNP output sourcing current or a higher output
voltage level is desired, an external DC supply may be
connected between the “DC Out/In” and “Comm” terminals.
This supply will determine the PNP output voltage level, and
must be in range of +13 to 30 VDC.
An external supply can provide the additional output sourcing
current required in applications where two or more outputs are
ON simultaneously. However, the maximum rating of 100mA
per individual output must not be exceeded, regardless of
external supply capacity.
Relay: Form A contact, rating = 5 A @ 250 VAC, 30 VDC (resistive
load) , 1/10 HP @ 120 VAC (inductive load).
Relay Life Expectancy: 100,000 cycles min. at max. load rating.
Programmable Timed Output: User selectable output time
resolutions.
0.01 Second Resolution: 0.01 to 99.99 sec., +/-0.01%
+20 msec max. (Prescalers less
than 2)
0.1 Second Resolution: 0.1 to 999.9 sec. +/- 0.01 + 100
msec max. (Prescalers less
than 2)
9. RS485 SERIAL COMMUNICATIONS (Optional): Up to 32 units can
be connected.
Baud Rate: Programmable from 1200 to 9600 baud.
Address: Programmable from 0 to 99.
Data Format:10 Bit Frame, 1 start bit , 7 or 8 data bits, 1 or no
Parity bit, and 1 stop bit.
Parity: Programmable for Odd (7 data bits), Even ( 7 data
bits) or None ( 8 data bits).
10. CERTIFICATIONS AND COMPLIANCES:
UL Recognized Component, File # E195514
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
CE Compliant:
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
electrostatic discharge EN 61000-4-2
electromagnetic RF fields EN 61000-4-3
fast transients EN 61000-4-4
RF conducted interference EN 61000-4-6
simulation of cordless phone EN V502204
Emissions to EN 50081-2
RF interference EN 55011 enclosure class A
11. ENVIRONMENTAL CONDITIONS:
Operating Temperature: +32°F to +122°F [0°C TO +50°C]
Storage Temperature: -40°F to +158°F [-40°C to +70°C]
Operating and Storage Humidity: 85% max. relative humidity (
non-condensing) from +32°F to
+122°F [0°C to +50°C]
Altitude : Up to 6500 Feet [1981 Meters]
12. ELECTRICAL CONNECTIONS: Wire clamping screw terminals.
13. CONSTRUCTION: Black plastic case with collar style panel latch.
The panel latch can be installed for horizontal or vertical stacking.
Black plastic textured bezel can be removed from the case without
removing the case from the panel or disconnecting the wiring. Front
panel meets NEMA4X/IP65 requirements for indoor use, when
properly installed. Installation Category II, Pollution Degree 2.
14. WEIGHT: 6.0 oz [170g]
SINGLE PRESET MODELS
The 8301 has a solid-state output that operates in parallel with a relay
output. The solid-state output is available as an NPN or PNP open
collector transistor.
DUAL PRESET MODELS
The 8302 has two outputs that are activated from presets 1 and 2.
These outputs can be relay or solid-state outputs. The solid-state
outputs are available as NPN or PNP open-collector transistors. Units
with solid-state outputs can be ordered with an optional prescaler
output.
3 PRESET BATCH MODELS
The 8303 has a secondary counter that can be used for batch
counting, or to keep a total count. This second counter can be
programmed to operate in one of eight operating modes. Output 1 and
2 are assigned to the primary process counter (C1). Output 3 is
assigned to the secondary Batch/Total counter (C2). The three preset
batch unit can be ordered with solid-state or relay outputs. Units with
solid-state outputs have a User Input 2 terminal available. The relay
model has a relay output for Output 2 and Output 3 (Batch/Total).
Output 1 is available only as solid-state.
PRESCALER OUTPUT MODELS
The 8304 is a dual preset counter with solid-state outputs. These
models have an additional output configured as a prescaler output.
Each time the least significant digit of the display increments, the
Prescaler output provides a pulse. The width of this pulse is variable in
that the output will turn off after a programmed number of count input
pulses has occurred (1-9). The Prescaler output can also be
programmed to activate when the 10’s digit of the display increments,
rather than the least significant digit.
Note: Prescaler Output Models are limited to two programmable count
modes and prescaler values of 1.00000 or less. See Count
Input Modes for available modes.
FRONT PANEL KEYPAD
- Performs user Programmed Function.
- Cycles through secondary displays.
- Enters Programming Mode or Protected Value Menu when
pushed and held for 2 seconds.
- Scrolls through programming displays.
- Enters Data Values.
- Selects next available mode in programming mode.
- Increments digit in digit Entry mode.
- Increments value in Auto Scrolling entry mode.
- Selects Digit to right when in Digit Entry mode.
- Decrements value in Auto Scrolling entry mode.
www.redingtoncounters.com
Model 83
92
Electronic LCD Predetermining Counter
Dimensions
For Details on Models and Descriptions, see the Ordering Information section
MULTIPLE UNIT STACKING
The Model 83 is designed for close spacing of multiple units. Units can be stacked either horizontally or vertically. For vertical stacking, install
the panel latch with screws to the sides of the unit. For horizontal stacking, the panel latch screws should be at the top and bottom of the unit.
The minimum spacing from center line to center line of the units is 1.96” (49.8 mm). This spacing is the same for vertical or horizontal stacking.
Note: When stacking units, provide adequate panel ventilation to ensure that the maximum operating temperature range is not exceeded.
PANEL CUTOUT SPACING FOR MULTIPLE UNIT STACKING.
HORIZONTAL ARRANGEMENT SHOWN.
1.96 [49.8]
MAX.
2.39 [60.7]
MAX.
2.39 [60.7]
MAX.
1.96 [49.8]
MAX.
PANEL LATCH INSTALLED FOR
VERTICAL UNIT STACKING
PANEL LATCH INSTALLED FOR
HORIZONTAL UNIT STACKING
Applications
Cut-to-lengthBatchingConvert-
ing
Packag-
ing
Models Description
IF NEMA 4 IS NOT REQUIRED,
THIS PANEL MATERIAL MAY BE REMOVED.
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1.96
(49.8)
MIN
93
www.redingtoncounters.com
Model 83 Electronic LCD Predetermining Counter
Ordering Information
RELAY OUTPUT BOARDS
DESCRIPTION NPN O.C. * PNP O.C. RELAY PART NUMBER
Single Preset Yes No Yes 1726-044S
Dual Preset No No Yes 1726-045S
Batch Yes No Yes 1726-046S
* PNP outputs are non-stock items
* Items in bold are normally in factory stock.
Note: On batch Relay Models, Outputs 2 and 3 are relays, and Output 1 (01) is a solid-state output.
MODEL NO. DESCRIPTION NPN O.C. *PNP O.C. RELAY RS485 PART NUMBERS FOR AVAILABLE
OUTPUT(S) OUTPUT(S) OUTPUT(S) SUPPLY VOLTAGES
18-36 VDC/24 VAC 85 TO 250 VAC
8301 1 Preset Counter Yes No Yes No 8301-0110 8301-1110
Backlit LCD
2 Preset Counter Yes No No No 8302-0100 8302-1100
Backlit LCD
2 Preset Counter Yes No No Yes 8302-0101 8302-1101
8302 Backlit LCD
2 Preset Counter
Backlit LCD No No Yes No 8302-0010 8302-1010
2 Preset Counter
Backlit LCD No No Yes Yes 8302-0011 8302-1011
2 Preset Counter
w/Prescaler Output Yes No No No 8304-0100 8304-1100
8304 Backlit LCD
2 Preset Counter
w/Prescaler Output Yes No No Yes 8304-0101 8304-1101
Backlit LCD
3 Preset Batch
Counter Yes(01) No Yes No 8303-0110 8303-1110
Backlit LCD
3 Preset Batch
Counter Yes(01) No Yes Yes 8303-0111 8303-1111
8303 Backlit LCD
3 Preset Batch
Counter Yes No No No 8303-0100 8303-1100
Backlit LCD
3 Preset Batch
Counter Yes No No Yes 8303-0101 8303-1101
Backlit LCD
www.redingtoncounters.com
Model 83
94
Electronic LCD Predetermining Timer
The Model 83 Timer is available in single or dual preset models. The 83 Timer features a 7 segment, 2 lines by 6-digit backlit LCD display. The
main display line is red and shows the timer value. The smaller secondary display line is green and can be used to view the preset values or
output time values.
The 83 Timer can be configured for a variety of different operating modes to meet most timing application requirements. Twelve timing ranges are
available from thousands of a second to hours and minutes. Decimal points are used to separate the time units (hours, minutes, seconds). Timing
can be cumulative or can reset and start upon each power cycle. “on delay” or “off delay”, “single shot”, “repetitive auto cycling” modes are all
supported.
The 83 Timer can also be configured to continue or stop timing upon reaching preset. The display can be programmed to stop at the preset value
(reset to zero mode) or zero (reset to preset mode), or automatically reset to zero or preset and hold. Once stopped, the timer can be restarted
by manually resetting it, or it can be programmed to restart when power is reapplied. The 83 Timer has a run/stop input, 3 programmable user
inputs, and a programmable front panel function key. The run/stop and user inputs can be configured as sinking (active low) or sourcing (active
high) inputs via a single plug jumper. The user inputs and the front panel function key can be configured to provide a variety of functions.
Four front panel push-buttons are used for ease of programming the operating modes and data values, changing the viewed display, and
performing user programmable functions, e.g. reset, etc. The 83 Timer can be configured for one of two numeric data entry methods digit or
automatic scrolling.
Digital - The digital entry allows for the selection and incrementing of digits individually.
Automatic scrolling - This method allows for the progressive change of one through all digits positions by pressing and holding the up or
down button.
The dual preset models are available with solid-state or relay outputs. The single preset model has a solid-state and relay output in parallel. All
solid-state outputs are available in a choice of NPN current sinking or PNP current sourcing, open- collector transistor outputs. All relay output
boards are field replaceable.
RS485 communications - optional serial communication capability allows for interrogation and modification of the preset, and timer values.
Construction- The unit is made of lightweight, high impact plastic with a textured front panel and a clear display window. The front panel meets
NEMA4X/IP65 specifications when properly installed. Multiple units can be stacked horizontally or vertically. SMT, extensive testing, plus high
immunity to noise interference make the 83 Timer extremely reliable in industrial environments.
Displays values to (999999)
12 timing ranges
Field replaceable relay output boards
Solid state and relay output models
NEMA4X/IP65 sealed bezel
Status indicators for outputs
Security via programmable operator access
privileges and protected values menu
Programmable user inputs and front panel
function key
Horizontal or vertical stacking of multiple units
85 to 250VAC or 18 to 36VDC/24 VAC power units
RS485 communications option
Choice of numeric data entry modes
Output type
Serial communications
Voltage input
Display color
Number of presets
Features Options
Description
95
www.redingtoncounters.com
Model 83 Electronic LCD Predetermining Timer
Specifications
Display: 2 line by 6 digits LCD display, negative image
transmissive with RED (top line) and GREEN
(bottom line) backlighting. Positive image reflective
display units are non-stock available.
Main: 0.3" (7.6mm) high digits
Secondary: 0.2" (5mm) high digits
Annunciators:
Value: PRS, 1, and 2
Output: 01 and 02
POWER REQUIREMENTS:
AC Versions
AC Power: 85 to 250 VAC, 50/60Hz, 9VA max.
DC power: 11 to 14 VDC @ 159 mA max. (Non PNP
output models)
Note: Models with PNP current sourcing outputs must be
powered from AC
DC Versions
DC Power: 18 to 36 VDC: 5.5 W max.
AC Power: 24 VAC +/- 10%: 50/60 Hz: 7VA max.
Note: The 10% tolerance range on AC input voltage must be
strictly adhered to> DO NOT EXCEED 26.4 VAC
PEAK (START-UP CURRENT)
AC or DC Power: 500mA peak start-up current for 10 msec.
max.
DC OUT/ VSCR IN-terminal 10
For units that do not have PNP current sourcing outputs, this terminal
provides a DC output for sensor power (+ 12 VDC +/-15%). The
maximum sensor current is 100mA. For units with PNP current sourcing
outputs this terminal serves a dual purpose depending on the application
PNP output voltage level and current requirements.
1. The terminal may be used as a +12 VDC output for sensor
power. In this case, the PNP output voltage level will be
+12 VDC (+/-15%). A maximum of 100 mA is available for
the combination of sensor and PNP output sourcing
current.
2. If a higher PNP output voltage level or additional output
sourcing current is needed, an external DC supply may be
connected between the “DC OUT” ( V SRC IN) and
“COMM.” terminals. This supply will determine the PNP
output voltage level, and must be in the same range of +13
to +30 VDC.
An external DC supply can also provide the additional
output sourcing current required in applications where
two or more PNP outputs are “ON” simultaneously.
However, the maximum current range of 100mA per
individual output must not be exceeded, regardless of
external supply capacity.
3. MEMORY: Nonvolatile FRAM retains all program parameters and
Timer values.
4. SENSOR POWER: +12 VDC (+/- 15%) @ 100mA max.
5. INPUTS: Run/Stop, Usr. In1, Usr. In2, and Usr. In3.
Configurable as current sinking (active low), or
current sourcing (active high) inputs via a single
plug jumper.
Current Sinking: (active low) :
VIL = 1.5 VDC max. 22 K ohm pull-ups to 5 VDC
Current Sourcing: (active high): VIH = 3.5 min.
VIN max. = 30 VDC; 22K ohm pull-down.
Run/Stop Response Time : 250 microseconds max.
User Input Response Time: 5 msec. max.
6. TIME ACCURACY: +/- 0.01%
7. OUTPUTS: ( Output type and quantity model dependent)
Solid-State:
NPN Open Collector:
ISNK = 100mA max. @ VOL = 1.1 VDC max.;
VOH = 30 VDC max.
PNP Open Collector:
ISRC = 100mA max. ( See note) ; VOH = 12 VDC +/-15%
( using internal supply); VOH = 13 to 30 VDC ( using
external supply).
Note: The internal supply of the 83 Timer can provide a total of
100 mA for the combination of sensor current and PNP output
sourcing current. The supply voltage is +12 VDC (+/-5 %),
which will be the PNP output voltage level when using only the
internal supply.
If additional PNP output sourcing current or a higher output
voltage level is desired, an external DC supply may be
connected between the “ DC Out/In” and “Comm” terminals.
This supply will determine the PNP output voltage level, and
must be in range of +13 to 30 VDC.
An external supply can provide the additional output sourcing
current required in applications where two or more outputs are
“ON” simultaneously. However, the maximum rating of 100mA
per individual output must not be exceeded, regardless of
external supply capacity.
Relay: Form A contact, rating = 5 A @ 250 VAC, 30 VDC (resistive
load) 1/10 HP @ 120 VAC (inductive load).
Relay Life Expectancy:
100,000 cycles min. at max. load rating.
Programmable Timed Output:
User selectable output time resolutions.
0.01 Second Resolution: 0.01 to 99.99 sec., +/-
0.01% +10 msec max.
0.1 Second Resolution: 0.1 to 999.9 sec. +/- 0.01
% +100 msec max.
8. RS485 SERIAL COMMUNICATIONS (Optional):
Up to 32 units can be connected.
Baud Rate: Programmable from 1200 to 9600 baud.
Address: Programmable from 0 to 99
Data Format: 10 Bit Frame, 1 start bit , 7 or 8 data bits, 1 or
no Parity bit, and 1 stop bit.
Parity: Programmable for Odd (7 data bits), Even ( 7 data bits)
or None ( 8 data bits).
9. CERTIFICATIONS AND COMPLIANCES:
UL Recognized Component, File # E195514
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
CE COMPLIANT :
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
electrostatic discharge EN 61000-4-2
electromagnetic RF fields EN 61000-4-3
fast transients EN 61000-4-4
RF conducted interference EN 61000-4-6
simulation of cordless phone ENV50204
Emissions to EN 50081-2
RF interference EN 55011 enclosure class A
10. ENVIRONMENTAL CONDITIONS:
Operating Temperature: +32°F to +122°F [0°C to +50°C]
Storage Temperature: -40°F to +158°F [-40°C to +70°C]
www.redingtoncounters.com
Model 83
96
Electronic LCD Predetermining Timer
Operating and Storage Humidity:
85% max. relative humidity ( non-condensing) from
+32°F to +122°F [0°C to +50°C]
Altitude: Up to 6500 Feet
11. ELECTRICAL CONNECTIONS:
Wire clamping screw terminals.
12. CONSTRUCTION: Black plastic case with collar style panel latch.
The panel latch can be installed for horizontal or vertical stacking. Black
plastic textured bezel can be removed from the case without removing
the case from the panel or disconnecting the wiring. Front panel meets
NEMA4X/IP65 requirements for indoor use, when properly installed.
Installation Category II, Pollution Degree 2.
13. WEIGHT: 6.0 oz [170g]
SINGLE PRESET MODELS
The 8321 Timer offers a choice of twelve timing ranges with eighteen
different operating modes. The unit has a solid-state output that operates
in parallel with a relay output. The solid-state output is available as an
NPN or PNP open collector transistor.
DUAL PRESET MODELS
The 8322 Timer offers a choice of twelve timing ranges with 44 operating
modes. The unit is available with solid-state or relay outputs. The solid-
state outputs are available as NPN or PNP open collector transistors.
For Details on Models and Descriptions, see the Ordering Information section
1.96 [49.8]
MAX.
2.39 [60.7]
MAX.
2.39 [60.7]
MAX.
1.96 [49.8]
MAX.
PANEL LATCH INSTALLED FOR
VERTICAL UNIT STACKING
PANEL LATCH INSTALLED FOR
HORIZONTAL UNIT STACKING
PANEL CUTOUT SPACING FOR MULTIPLE UNIT STACKING.
HORIZONTAL ARRANGEMENT SHOWN.
IF NEMA 4 IS NOT REQUIRED,
THIS PANEL MATERIAL MAY BE REMOVED.
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1.96
(49.8)
MIN
MULTIPLE UNIT STACKING
The Model 83 is designed for close spacing of multiple units. Units can be stacked either horizontally or vertically. For vertical stacking, install the
panel latch with screws to the sides of the unit. For horizontal stacking, the panel latch screws should be at the top and bottom of the unit. The
minimum spacing from center line to center line of the units is 1.96” (49.8 mm). This spacing is the same for vertical or horizontal stacking.
Note: When stacking units, provide adequate panel ventilation to ensure that the maximum operating temperature range is not exceeded.
Applications
Models Description
Dimensions
Mixing Batch ControlVolumetric measurement
97
www.redingtoncounters.com
Model 83 Electronic LCD Predetermining Timer
MODEL NO. DESCRIPTION NPN O.C. * PNP O.C. RELAY RS485 PART NUMBERS FOR AVAILABLE
OUTPUT(S) OUTPUT(S) OUTPUT(S) SUPPLY VOLTAGES
18-36 VDC/24 VAC 85 TO 250 VAC
8321 1 Preset Timer Yes No Yes No 8321-0110 8321-1110
Backlit LCD
2 Preset Timer No No Yes No 8322-0010 8322-1010
Backlit LCD
8322 2 Preset Timer No No Yes Yes 8322-0011 8322-1011
Backlit LCD
2 Preset Timer Yes No No No 8322-0100 8322-1100
Backlit LCD
2 Preset Timer Yes No No Yes 8322-0101 8322-1101
Backlit LCD
Ordering Information
* PNP Outputs are non-stock items
RELAY OUTPUT BOARDS
DESCRIPTION NPN O.C. * PNP O.C. RELAY PART NUMBER
Single Preset Yes No Yes 1726-044S
Dual Preset No No Yes 1726-045S
3 Preset Yes No Yes 1726-046S
* PNP Outputs are non-stock items
* Items in bold are normally in factory stock.
www.redingtoncounters.com
Model 92
98
Electronic Hand Held Tachometer
The Redington Model 9200-HTK hand tachometer kit combines low cost with convenience. Simple to use… push the measurement button to
record the speed. The tachometer can be used for contact or non-contact measurement on rotating machinery or surface speed. The
photoelectric probe is used with reflective tape to detect rotating objects. The accessory adaptor with pointed tip can be added for contact
measurement or wheels can be used for surface speed measurement. For measuring in tight or confined spaces, an optional remote sensor is
available.
Power Source: 4 alkaline batteries (AAA, 1.5 V)
continuous measurement 20 hours.
Accuracy: ± 0.01% ± 1 digit RPM f/min. (others ±
0.05% or ± 1 digit including tolerance for
conversion).
Measurement Distance: 2”-14” (50-300mm) with reflective tape.
Measurement Range: 6.0 - 99,999.9 RPM
Sampling Time: 1.0-10.2 sec.
Automatic Power Cutoff: After 3 minutes from last measurement.
Display: 6 digit LCD
Approvals: CE Compliant, passed EMC tests EMI:
EN50081-1 & EMS: EN50082-1
Weight: 7 oz [199g] (with in-line contact
adaptor).
Operating Temperature: +41°F to +104°F [+5°C to +40°C]
Combination unit - photo and contact
Wide speed range - 6.0 - 99,999.9 RPM, 0.1 resolution
Sampling time of 1-10 seconds
Automatic shutoff after 3 minutes
Digital display with low battery alarm and reflective
light input indicator
Carrying case included
Remote sensor for measurement in hard to reach places
9200-HTK Hand Tachometer Kit: includes, Hand Tach. (Photo), In-
Contact adaptor, Rubber tips (3), Reflective Tape (10
sheets), Surface Speed wheels, 1 ea. (1/10 m/min., and
1/10 yd./min.), Carrying Case, Batteries (4 AAA size, 1.5
V, Instructions Manual).
9200-HT Hand Held Tachometer
1887-021S Remote Probe
1895-004S Rubber Tips
1895-005S Surface Wheel (1/10 Meter)
1895-006S Surface Wheel (1/10 Yard)
200507-046S Reflective Tape (10 Sheets)
Models DescriptionModels Description
Specifications
Features Options
Description
* Items in bold are normally in factory stock.
99
www.redingtoncounters.com
Model 92 Electronic Hand Held Tachometer
6.93
[176.0]
2.41
[61.1]
Check motor speedsSpeed of many rotating objects Conveyor line speed
2.27
[57.7]
4.78
[121.4]
Dimensions
Applications
www.redingtoncounters.com
Model 65
100
Encoder Standard Industrial Rotary Pulse Generator
These versatile, dependable and rugged encoders are ideal for use with electronic counters, PLC’s, motion controllers and motor drives. A wide selection
of resolutions (Pulse Per Revolution, PPR) makes the Model 65 ideal for a wide variety of applications. The sealed aluminum housing offers greater
protection from wash down, sprays, dust, moisture, shock and other hazards found in industrial environments.
Description
Features Options
Specifications
Input: Voltage: +5 to +28VDC
Current: 80mA with no output load
Output: Current sinking NPN open collector
Transistor
Single channel, 250mA max
quadrature, 250mA max per output.
Connections: Eurofast connector
Cable /Connector: (8 pin) RKC 8T2/S618, (Turck P/N) 2 meters
long
Housing: Black non-corrosive finished, aluminum
Max. Shaft Speed: 6,000 RPM
Frequency Response: 0-125 kHz
Bearings: ABEC 3 double sealed shaft ball bearings
Models Description PPR*Models Description PPR*
Dimensions
Applications
Quadrature or unidirectional output
3/8" [9.5mm] shaft diameter, 303, stainless steel
Double shaft extension
NPN transistor output
Radial Load: 40 pounds maximum
Axial Shaft Loading: 30 pounds maximum
Starting Torque: 3.00 oz-inches
Moment of Inertia: 6.5 X 106 oz in sec2
Mounting: Tapped mounting holes on three
sides for base or face mounting
Weight: 1lb ([284g]
Operating Temp: 32°F to 185°F [0°C to 85°C]
Storage Temp: -13°F to +212°F [-25° to +100°C]
Shock: 50 g’s @ 100ms duration
Vibration: 10 g’s @ 58 to 500 cps
Humidity: 98% RH non-condensing
6510-0060 60
6510-0100 100
6510-0600 SINGLE CHANNEL 600
6510-1000 1,000
6510-1200 1,200
6520-0010 10
6520-0012 DUAL CHANNEL 12
6520-0100 (QUADRATURE) 100
6520-0120 120
6520-0500 500
6520-0600 600
RKC 8T2/S618 8 Pin Cable 6' (2 meters) long
*Only popular PPR’s are listed, other PPR’s are available on special order.
2.25 [57.2]
2.25 [57.2] 0.07 [1.8]
2.25
[57.2]
Ø.25 [6.4]
#6-32 THD X .25 DEEP
ON 2.00 [50.8] BOLT CIRCLE
BOTH ENDS AND BOTTOM
1.13 [28.6]
0.65 [16.5]
0.71 [18.0]
0.83
[21.0]
0.50
[12.7]
0.03
[0.8]
Rugged duty housing
+5 to +28VDC input power
Wide selection of resolutions
Heavy duty sealed bearings
IP 65 shaft seal
Measuring Wheel
Length sensors
Generating pulses from
idler roll with RPG
Generating Quadrature signal for
position from lead screw rotation using
RPG
101
www.redingtoncounters.com
Model 65 Sensor Proximity Switch
Description
Specifications
Applications
Parts Counting Object Detection Tachometer input/gear-tooth profile
The Redington Model 65 proximity switch has an all-metal housing, nickel plated brass, compact size and a long operating distance, 1.5 mm. The
Model 65 has a NEMA 6 & 6P, IP67 rating. Its all-metal housing and sealing makes it ideal for most extreme environmental conditions. The Model
65 has built - in protection for short-circuit protection, polarity reversal and power on reset.
Embeddable mounting
5,000 Hz switching frequency
IP 67 rating
10-32 VDC operating range
LED output state indicator
8mm diameter
Supply Voltage: 10-30VDC
Sensing Range: 0.1’’ [1.5mm]
Sensor Diameter: 8mm
Connection: PVC cable 6’ [2m]
Degree of Protection: IP67
Mounting: Embeddable
Max. Switching Frequency: 5,000 Hz
Out-put Status Indicator: LED
Out-put Type: NPN/N.O. output
Built-in Protection: Short-circuit
Polarity reversal
Power-on reset
Features
Permissible Ripple Content: < 20%
No-load Supply Current: < 10mA
Output Current: < 200mA
Leakage Current at Output: < 0.1mA
Voltage Drop, Switched State: < 2.0V
Ambient Temperature Range: -13ºF to 158ºF [-25ºC to 70ºC]
Temperature Drift: < 10%
Hysteresis% Sr: 1 to 15% (5% typ.)
Repeat Accuracy: (IEC 60947-5-2): < 5% Sr
Approvals: CE Compliant
Dimensions Wiring Diagram
Models
DW-AD-601-M8
39 V 39 V
39 V Blue
Black
Brown +U
A
0V
R
100 kOhm L
(1)
(4)
(3)
B
Load
UB10__30VDC
200mAmax.
IA
* Item is normally in factory stock.
1.38 [35.0]
M8X1
0.16 [4.0]
Ø.14 [3.5]
SW13
LED
www.redingtoncounters.com
Glossary
102
TERM DEFINITION
A-B Input The B input pulses are subtracted from the A
input pulses.
This type of input is used on counters &
indicators.
A+B Input The A and B input pulses are added together.
This type input is used on counters and
position indicators.
AC Alternating current; an electric current that
reverses its direction at recurring intervals.
Accuracy The closeness of an indication or reading of a
measurement device to the actual value of the
quantity being measured. Usually expressed
as a ± percent of full scale output or reading,
Add/Subtract The ability to count up and down.
Ammeter An instrument used to measure current.
Analog A signal that varies continuously in amplitude
without interruption.
Analog Output A circuit whose output is a reproduction of its
input..
Automatic Reset A reset that is based on a pre-programmed
event. Used in counters or timers.
Baud Rate The rate at which each bit is transferred to and
from a device.
Bidirectional The counter or encoder can count in both
directions.
Bit This is the name for a binary digit.
Byte A sequence of adjacent binary digits operated
on as a single unit. A byte is eight bits in
length.
Capacitor An assembly of one or more pairs of conduc-
tors separated by insulators used to store an
electrical charge. The capacitance of is
measured in FARADS or parts thereof.
CE (Conformite Europeeene mark) A symbol (CE)
applied to finished products and machinery
indicating it meets all applicable European
Directives. For electrical and electronic
“finished products”, such as electronic and
electromechanical counters, hour meters,
these include the Low Voltage Directive and,
where relevant, the Electromagnetic Compat-
ibility (EMC) Directive.
Color code The ANSI established color code for the
thermocouple wires in the negative lead is
always RED. Color code for base metal
thermocouples is YELLOW for Type K, BLACK
for type J, PURPLE for Type E and BLUE for
Type T.
Control point The set point at which a system is to be
maintained.
CSA (Canadian Standards Association) An inde-
pendent Canadian testing and standards-
making org. similar to Underwriters Laborato-
ries (UL) in the USA. “CSA -certified “ products
meet relevant CSA electrical and safety
standards.
Current sinking /Open collector
In the “off” state the transistor can be viewed as
an open switch. When energized it turns “ON”,
connecting the output to the ground return lead.
The transistor is usually NPN.
Current sourcing/Open collector
In the “off” state the transistor can be viewed as
an open switch. When energized it turns “ON”,
connecting the output to the voltage supply
lead. The transistor is usually PNP.
DC Direct current: An electric current flowing in one
direction only and substantially constant in
value.
Die A single piece of silicon onto which a semicon-
ductor circuit has been fabricated.
(Plural= Dice)
Digit A measurement of the display span of a panel
meter. By convention, a full digit can assume
any value from 0 through 9, a 1/2 digit will
display a 1 and overload at 2. For example, the
full scale value of a 3 1/2 digit display is 1999.
Digital Volt Meter A device used to measure voltages and give a
digital read out.
103
www.redingtoncounters.com
Glossary
DIN A Deutsche Industrial Norme standard. Some
RCI products utilize these dimensional
standards.
Direct drive Refers to the gear ratio in a mechanical
counter one revolution of the input shaft
equals 10 counts.
Drift A change of a reading or a set point value over
long periods due to several factors including
change in ambient temperature, time, and line
voltage.
EMF Electromotive force. A rise in (electrical)
potential energy. The principle unit is the volt.
EMI Electromagnetic interference.
Encoder An electromechanical device that translates
mechanical motion into electrical pulses.
FRAM Nonvolatile memory. Uses the ferroelectric
effect for a storage mechanism.
Hertz (Hz) Units in which the frequency is expressed.
Synonymous with cycles per second.
Hysteresis In an ON-OFF controller it defines the differ-
ence between the two switching points. It
refers to the difference between the value at
which the alarm switches on and the value at
which the alarm switches off again.
Incremental encoder
A device that provides a series of periodic
signals due to mechanical motion. The number
of successive cycles corresponds to the
resolvable mechanical increments of motion.
Impedance The total opposition to electrical flow (resistive
plus reactive).
Input impedance The resistance of a panel meter as seen from
the source. In the case of a voltmeter, this
resistance has to be taken into account when
the source impedance is high; in the case of
an ammeter, when the impedance is low.
Joule The basic unit of thermal energy.
LCD (Liquid Crystal Display) A liquid crystal display
is made of two glass plates, each with a
transparent conductive coating, which
sandwich the crystal material. When a voltage
is applied molecules in the liquid crystal align
themselves with the field generated preventing
light from passing, creating a display segment.
The pattern on the display forms the required
picture or numeral.
LED (Light Emitting Diode) A diode which emits light
of a particular wavelength when a current is
passed through it.
LSI ( Large Scale Integration) Used to refer to
integrated circuits which today have from
thousands to millions of components on one
silicon chip.
Load The electrical demand of a process expressed
as power (watts), current (amps), or resistance
(ohms).
Maximum operating temperature
The maximum temperature at which an
instrument can be operated and still be within
operating specifications.
Micro A prefix meaning one millionth.
Milli A prefix meaning one thousandth.
Multiplication Any technique used to obtain an output
resolution different from the line count.
Nano A prefix meaning one thousand-millionth.
Noise An unwanted electrical interference on the
signal wires.
OHM The unit of electrical resistance. A constant
voltage of one volt across a resistance of one
OHM will produce a current in it of one
ampere. OHMS LAW V=IR
Ohmmeter An instrument used to measure resistance.
Optical Isolator Sometimes referred to as an optocoupler. A
device that isolates two stages of a circuit;
e.g.., input and output from each other so that
interference in one will not effect the other.
Optical Isolation A method of reducing noise interference
between two circuits using optical isolators.
Predetermining The counter can provide an “output” signal at a
predetermined count or time.
www.redingtoncounters.com
Glossary
104
Prescaler Used to convert a pulse input signal to the
desired units of indication.
Quadrature Signals
A dual output encoder used for bidirectional
motion control. One channel leads the other by
90 degrees.
RAM ( Random Access Memory) A memory device
which may be accessed at random and which
may be written to (altered) or read at any time.
Range The values specified by upper and lower limits.
Rate Velocity or distance/unit time; can be rotational
distance.
Relays/Electromechanical
Relays offer one or more “hard” contacts
(metal-to metal) and are switched to the open
or closed position by applying voltage to an
electromagnetic coil.
Resistance The resistance to the flow of electric current
measured in ohms. For a conductor, a
resistance is a function of diameter, resistivity
(an intrinsic) property of the material and
length.
Resistor A device used primarily for its resistance, which
is measured in OHMS. Its primary use is to
limit the flow of electrons through a circuit.
Resolution The number of increments on an encoder disc.
Also, the smallest possible value that an
instrument can measure.
Revolution drive Refers to the gear ratio in a mechanical
counter. One revolution of the input shaft
equals 1 count.
ROM (Ready Only Memory) A device is programmed
with information which should not be lost and
which only needs to be read by a computer.
Once programmed it cannot be repro-
grammed.
RS 485/422/232 Standards established by the EIA for serial
data transmission between two devices.
RTD Resistance temperature detector. The resis-
tance changes as a function of temperature.
Scaling For direct readout in engineering units, scaling
is the capability of the product to associate any
desired value to the electrical input range.
Seebeck effect This is the basis of thermocouples. When a
circuit is formed by a junction of two dissimilar
metals and the junctions are held at different
temperatures, a current will flow in the circuit
caused by the difference in temperature
between the two junctions.
Silicon The basic element used in the manufacturer of
most semiconductor devices.
Solid-State Relays
Use switching elements such as transistors for
DC loads and SCR’s or FET’s for AC loads.
Stroke Counter Refers to the input shaft of a mechanical
counter. The counter will count when the lever
is moved through an arc.
Thermocouple The junction of two dissimilar metals which has
a voltage output proportional to the difference
in temperature between the hot junction and
the wires ( cold junction).
Thermocouple type Type Material (ANSI Symbol)
J Iron/Constantan
K Chromel/Alumel
T Copper/Constantan
E Chromel/Constantan
R Platinum/Platinum
13% Rhodium
S Platinum/Platinum
10% Rhodium
B Platinum
6% Rhodium/Platinum
/30% Rhodium
G* Tungsten Tungsten
26% Rhenium
C* Tungsten
5% Rhenium/Tungsten
26% Rhenium
D* Tungsten
3% Rhenium/Tungsten
/25% Rhenium
*Not ANSI symbols
105
www.redingtoncounters.com
Glossary
Top coming The input shaft rotates towards you, when
viewing the counter from the front.
Top going The input shaft rotates away from you, when
viewing the counter from the front.
Totalizer A type of counter with no outputs, which is used
for accumulating the number of input pulses.
Transistor From “transfer resistor”, it is a semiconductor
device with threeelectrodes that act as either
an amplifier or switch.
Transducer A device (or medium) that converts energy from
one form to another. The term is generally
applied to devices that take physical phenom-
ena (pressure, temperature, humidity, flow,
etc.) and convert them to electrical signal.
Sometimes referred to as “sensor”.
UL Underwriters Laboratories, Inc. An independent
laboratory that establishes safety standards for
commercial and industrial products.
Unidirectional The counter or encoder can only count in one
direction.
Volt The (electrical) potential difference between
two points in a circuit. The fundamental unit is
derived as work per unit charge- (V=W/Q). One
volt is the potential difference required to move
one coulomb of charge between two points in
a circuit using one joule of energy.
X2,X4 Logic A type of logic that multiplies the signal by a
factor of 2 or 4 respectively.
NEMA STANDARDS
NEMA Standards Publication No. 250 guidelines
NEMA 1 Indoor use- Protects against accidental contact
by personnel & falling dirt.
NEMA 2 Indoor use-Protects against falling dirt, liquid, &
light splash.
NEMA 3 Outdoor use-Protects against rain, sleet, snow,
dirt & dust.
NEMA 3S Outdoor use- Protects against rain, sleet, snow,
dirt, dust & ice buildup.
NEMA 4 In-or-Outdoor-Protects against dirt, dust, hose
down, (and heavy splash).
NEMA 4X In-or Outdoor- Protects against dirt, dust, hose
down & corrosion.
NEMA 6 In-or Outdoor- Protects against dirt, dust, hose
down & occasional submersion.
NEMA 6P In-or Outdoor- Protects against dirt, dust, hose
down & prolonged submersion.
NEMA 7 Indoor Use- For use in areas of explosive
gases or vapors or combustible dust.
NEMA 9 Indoor Use- For use in areas of atmospheres
containing combustible dust.
NEMA 12 Indoor Use- Protects against dirt, dust, light
splash & oil or coolant spray.
NEMA 13 Indoor Use- Protects against dirt, dust, light
splash, & oil or coolant spray.
The rating system established by IEC Publications 144 and
529 define the following “IP” ratings:
1ST CHARACTERISTIC:
Protection against and penetration of solid bodies.
Numeral Short Description
0 Non-protected
1 Protected against solid objects greater
than 50mm
2 Protected against solid objects greater
than 12mm
3 Protected against solid objects greater
than 2.5mm
4 Protected against solid objects greater
than 1.0mm
5 Dust protected
6 Dust-tight
2nd CHARACTERISTIC:
Protection against and penetration of liquids.
Numeral Short Description
0 Non-protected
1 Protected against dripping water
2 Protected against dripping water when tilted up
to 15 degrees
3 Protected against spraying water
4 Protected against splashing water
5 Protected against water jets
6 Protected against heavy seas
7 Protected against the effects of immersion
8 Protected against submersion
www.redingtoncounters.com
106
Part# Index
1
1-1006 19
1-2015 35
1-2025 35
1-2035 35
1-2045 35
1-2215 36
1-2225 36
1-2235 36
1-2245 36
1-2315 36
1-2325 36
1-2715 37
1-2735 37
1-2916 39
1-2926 39
1-2936 39
1-2946 39
1-4103 41
1-4615 42
1-4625 42
1-4635 42
1-4635T 42
1-4645 42
1-PCU-13 44
1-PCU-14 44
1-PCU-24 44
1-PCU-33 44
1-PCU-33T 44
1-PCU-34 44
1-PCU-43 44
1-PCU-44 44
10007-009S 42
10007-010S 35
10011-001S 42
1022-006S 37, 38, 39
1071-024S 19
11-0825 30
11-0845 30
11-1904 34
11-2916 40
11-2936 40
11B-1415 31
11B-1425 31
11B-1435 31
11B-1445 31
11B-1515 31
11B-1525 31
11B-1535 31
11B-1545 31
11B-1615 31
11B-1625 31
11B-1635 31
11B-1645 31
11B-1715 31
11B-1725 31
11B-1735 31
11B-1745 31
12-1804 33
12-1904 34
1255-004S 39
13-1804 33
13-1904 34
14-1904 34
15-1904 34
1726-044S 93, 97
1726-045S 93, 97
1726-046S 93, 97
1887-021S 98
1895-004S 98
1895-005S 98
1895-006S 98
2
2-1006 19
2-1007 20
2-1016 19
2-1017 20
2-1284 28
2-2936 39
2-4016 21
2-4017 21
2-4103 41
2-4104 41
2-4416 23
2-4615 42
2-4625 42
2-4635 42
2-4645 42
200507-046S 98
200557-001S 85, 88
200557-002S 85, 88
21-1904 34
21-2916 40
21-2926 40
21-2936 40
21-2946 40
22-1904 34
22-2936 40
23-1904 34
24-1904 34
25-1904 34
3
3-1006 19
3-1007 20
3-1804-10 33
3-1804-2 33
3-1804-3 33
3-1804-4 33
3-1804-5 33
3-1804-6 33
3-1804-7 33
3-1804-8 33
3-1804-9 33
3-2835 38
3-4104 41
31-1904 34
32-1904 34
33-1904 34
3301-0000 8
3301-0010 8
3301-1000 8
3301-1010 8
3301-2000 8
3301-2010 8
3301-3000 8
3301-3010 8
3302-4322 10
3311-0000 46
3311-0010 46
3311-1000 46
3311-1010 46
3311-2000 46
3311-2010 46
3311-3000 46
3311-3010 46
34-1904 34
35-1904 34
4
4-2835 38
41-1904 34
42-1904 34
43-1904 34
44-1904 34
45-1904 34
5
5-2835 38
5-4645 42
5003-001S 13, 50, 76
5003-002S 8, 46
5003-003S 8, 46
5003-004S 8, 46
5003-005S 8, 46
5003-007S 72, 74
5120-0000 48
5120-0100 48
5120-0200 48
5120-0310 48
5120-1000 48
5120-1100 48
5120-1200 48
5120-2000 48
5120-2100 48
5120-2200 48
5140-0000 48
5140-0100 48
5140-0200 48
5140-0311 48
5140-0312 48
5200-0000 11
5201-0000 11
5202-0000 11
5210-0000 11
5211-0000 11
5300-0000 13
5300-0001 13
5300-0100 13
5300-0101 13
5300-1000 13
5300-1001 13
5300-1010 13
5300-1011 13
5300-1100 13
5300-2000 13
5300-2001 13
5300-2100 13
5300-2200 13
5300-2201 13
5320-0000 50
5320-0001 50
5320-0100 50
5320-0101 50
5320-1000 50
5320-1001 50
5320-1010 50
5320-1011 50
5320-1100 50
5320-2000 50
5320-2001 50
5320-2100 50
5320-2200 50
5320-2201 50
5321-0000 50
5321-0001 50
5322-0000 50
5322-0001 50
5330-0000 76
5330-0001 76
5330-1000 76
5330-1001 76
5330-2000 76
5330-2001 76
5330-2200 76
5330-2201 76
5400-0010 15
5400-1010 15
55XX 54
5600 57
5601 57
5602 57
5610 57
5611 57
5612 57
5620 57
5621 57
5622 57
5630 57
5631 57
5632 57
5640 57
5641 57
5642 57
5650 57
5651 57
5652 57
5660 57
5661 57
5662 57
5670 57
5671 57
5672 57
5700 60
5701 60
5702 60
5703 60
5704 60
5705 60
5706 60
5707 60
5708 60
5709 60
5710 60
5711 60
5712 60
5713 60
5902 62
5912 62
5922 62
5932 62
5942 62
5952 62
5962 62
5972 62
5982 62
5992 62
6
6510-0060 100
6510-0100 100
6510-0600 100
6510-1000 100
6510-1200 100
6520-0010 100
6520-0012 100
6520-0100 100
6520-0120 100
6520-0500 100
6520-0600 100
7
7-2215 36
7-2225 36
7-2235 36
www.redingtoncounters.com 107
Part# Index
7-2245 36
710-0001 66
710-0002 66
710-0003 66
710-0006 66
710-0008 66
710-0009 66
710-0013 66
710-0014 66
710-0018 66
710-0024 66
710-0026 66
710-0032 66
710-0051 66
711-0013 67
711-0014 67
711-0015 67
711-0019 70
711-0020 70
711-0041 70
711-0113 67
711-0114 67
711-0120 67
711-0123 67
711-0124 67
711-0130 67
711-0131 67
711-0132 67
711-0133 67
711-0134 67
711-0138 67
711-0150 69
711-0152 69
711-0160 69
711-0161 69
711-0162 69
711-0163 69
711-0164 69
711-0170 69
711-0171 69
711-0180 69
711-0182 69
711-0190 69
711-0191 69
711-0192 69
711-0193 69
711-0194 69
711-0195 69
711-0215 67
711-0216 67
711-0217 67
720-0001 71
720-0003 71
720-0004 71
720-0007 71
720-0008 71
720-0011 71
720-0012 71
720-0030 71
720-0031 71
720-0036 71
720-5300 64
721-0003 66
721-0004 64, 66, 71
721-0017 66
721-0018 66
722-0001 72
722-0002 72
722-0003 72
722-0004 72
731-0006 67
731-0040 67
731-0041 67
731-0042 67
731-0046 69
731-0051 67
732-0001 74
732-0002 74
732-0003 74
732-0004 74
750-0002 43
750-0007 43
750-0016 43
750-0114 43
750-0156 43
8
8-1006 19
8-1007 20
8-4416 23
8301 93
8301-0110 93
8301-1110 93
8302 93
8302-0010 93
8302-0011 93
8302-0100 93
8302-0101 93
8302-1010 93
8302-1011 93
8302-1100 93
8302-1101 93
8303 93
8303-0100 93
8303-0101 93
8303-0110 93
8303-0111 93
8303-1100 93
8303-1101 93
8303-1110 93
8303-1111 93
8304 93
8304-0100 93
8304-0101 93
8304-1100 93
8304-1101 93
8321 97
8321-0110 97
8321-1110 97
8322 97
8322-0010 97
8322-0011 97
8322-0100 97
8322-0101 97
8322-1010 97
8322-1011 97
8322-1100 97
8322-1101 97
85KLAD 83
85KLCA 83
85KLCD 83
85KLFQ 83
85KLIR 83
85KLJT 83
85KLKT 83
85KLPT 83
85KLRT 83
85KLTK 83
85KLVA 83
85KLVD 83
85KSAD 83
85KSAN 83
85KSCA 83
85KSCD 83
85KSDC 83
85KSFQ 83
85KSHG 83
85KSHR 83
85KSIR 83
85KSJT 83
85KSKT 83
85KSNP 83
85KSP1 83
85KSP2 83
85KSP3 83
85KSP4 83
85KSP5 83
85KSPT 83
85KSR1 83
85KSR2 83
85KSRD 83
85KSRT 83
85KSTK 83
85KSVA 83
85KSVD 83
85XX 84
8800-0000 88
8800-0001 88
8800-0010 88
8800-0011 88
8800-0100 88
8800-0101 88
8800-0110 88
8800-0111 88
8810-0000 88
8810-0001 88
8810-0010 88
8810-0011 88
8810-0100 88
8810-0101 88
8810-0110 88
8810-0111 88
9
9200-HT 98
9200-HTK 98
9415-001 16
9415-003 16
9415-005 16
9425-001 63
9425-003 63
9425-005 63
98WF 30, 40
B
B2-4904 26
B2-4906 26
B2-5804 45
B2-5804/E2 45
B2-5806 45
B2-5806/E2 45
B8-4904 26
B8-4906 26
B8-5804 45
B8-5804/E8 45
B8-5806 45
B8-5806/E2 45
D
D2-1284 28
D2-4904 26
D2-4906 26
D8-4817 24
DW-AD-601M8 101
E
E1-1804 17
E2-1804 18
E3-1804 18
P
P1-1006 19
P2-1006 19
P2-1007 20
P2-1016 19
P2-1027 20
P2-1284 28
P2-3106 29
P2-4816 24
P2-4817 24
P2-4904 26
P2-4906 26
P2-7717/60 65
P3-1006 19
P31-1026 19
P32-1026 19
P33-1026 19
P38-1026 19
P8-1006 19
P8-1027 20
P8-3206 29
P8-4816 24
P8-4817 24
P8-4904 26
P8-4906 26
P9-3206 29
P9-4904 26
P9-4906 26
PR2-1284 28
R
R2-1007 20
R2-1017 20
R2-3106 29
R2-4016 21
R2-4017 21
R2-4416 23
R2-4816 24
R2-7717/60 65
R8-3206 29
R8-4416 23
R8-4817 24
R9-4016 21
R9-4017 21
RKC 8T2/S618 100
RV2-4416 23
RV8-4416 23
S
SR2-4016 21
SR2-4017 21
SR2-4816 24
SR2-7717/60 65
SR8-4816 24
SR8-4817 24
T
T2-4016 21
T2-4017 21
V
V1-2936 39
V1-4816 24
V2-4416 23
V2-4816 24
V2-4817 24
V3-4816 24
V8-4016 21
V8-4017 21
V8-4416 23
V8-4816 24
V8-4817 24
V9-4816 24
www.redingtoncounters.com
108
Custom Products and Services
Contract Electronics, Molding and Assembly
Whether you need electronic design and production, plastic injection molding or product
assembly, Redington offers a wide variety of custom capabilities to meet your requirements.
With over 43 years experience as a high quality manufacturer, we can help you get your
product to market quickly, while maintaining the highest levels of quality.
Contact us today to learn more about how we can help
you with your specific needs.
Custom Capabilities
Redington manufactures a variety of custom products for our customers. These products range
from unique items designed for specific applications, to slight variations on our existing models.
If you don’t see exactly what you are looking for, give us a call and one of our
sales representative can work with you to solve your requirements.