DESIGNED & DIMENSIONED
IN MILLIMETERS
DO NOT
SCALE FROM
THIS PRINT
*
*
*
MPTC-XX-XX-XX-01-XX-X-RA-XX
POWER POSITIONS (PER END)
-01, -02, ***-03, ***-04
RIGHT ANGLE
SIGNAL POSITIONS
-80 (4 X 20)
-24 (4 X 6)
***-20 (4 X 5)
-16 (4 X 4)
***-12 (4 X 3)
PLATING SPECIFICATION
-L: SEE TABLE 3
-T: SEE TABLE 3
OPTION
-SD: SCREW DOWN
(SEE FIG 1, SHT 1)
-LC: LOCKING CLIP
(USE LC-07-TM)
(SEE FIG 2, SHT 2)
***-00, -01, -02
POWER POSITIONS (PER END)
-01: FOR 1.57[.062]
THICK PCB
(USE SUB-T-1M40-01-X)
-02: FOR 3.18[.125]
THICK PCB
(USE SUB-T-1M40-02-X)
-03: FOR 2.36[.093]
THICK PCB
(USE SUB-T-1M40-03-X)
TAIL LENGTH
-01
LEADSTYLE
0.41 .016
(TYP) REF
12.45
REF
0.50
SQ
.020
REF
"H"
8.18 .322
(TYP)
4.44
(TYP)
.175
1.88 .074
2.00 .079
"G"
(X SPACES @ 2.00 [.079])
5.38 .212
"D"
2
MAX SWAY (TYP)
"A"
"A"
"B""B"
MPT-02-RA-80-SD
C
C
C
01 (POWER)
C
MPT-XX-RA-XX-XX
P1 P2
D
C
B
1
2
A
3
20
"C" REF
3.56 .140
(TYP) REF
41.40
REF
1.630
12.27
REF
.483
4.06 .160
REF
15.70 .618
"B" REF
"F"
"F"
MP-80-Q
5.08 .200
REF
0.79
REF
.031
"A"
-
0.25
+
0.50
2.54 .100
REF
5.08
REF
.200
3.25
-
0.25
+
0.13 .128
-
.010
+
.005
SECTION "A"-"A"
SUB-T-1M40-XX-XX
C
C
FIG 1
MPTC-01-80-01-XX-X-RA-SD SHOWN
* = SEE TABLE 2 FOR AVAILABLE COMBINATIONS
** = NOT TOOLED
**
** = NOT TOOLED
*** = NOT RELEASED FOR PRODUCTION
C
S
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN MILLIMETERS.
TOLERANCES ARE:
DECIMALS ANGLES
.X:
0.3 [.01] 2
.XX:
0.13 [.005]
.XXX:
0.051 [.0020]
MATERIAL:
RIGHT ANGLE POWER TERMINAL
BY:
MPTC-XX-XX-XX-01-XX-X-RA-XX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
CLAY W
2/2/2007
4
1
SHEET SCALE: 1.5:1
INSULATOR: LCP
, COLOR: BLACK
TERMINAL: COPPER ALLOY
F:\DWG\MISC\MKTG\MPTC-XX-XX-XX-01-XX-X-RA-XX-MKT.SLDDRW
NOTES:
1. REPRESENTS A CRITICAL DIMENSION.
2. BURR ALLOWANCE: 0.038[.0015] MAX.
3. MINIMUM PUSHOUT FORCE: 2.22N [.5 LB].
4. PARTS TO BE PACKAGED IN TRAYS.
5. BOW ALLOWED AT 0.075MM[.0030]/25.0MM[.98].
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
REVISION S
1.42
REF
.056
1.42
-
0.13
+
0.20 .056
-
.005
+
.008
"D"
LC-07-TM
"F"
5.79 .228
REF
2
MAX SWAY (TYP)
FIG 2
MPTC-01-80-01-01-XX-X-RA-LC SHOWN
(SAME AS FIG 1, UNLESS OTHERWISE STATED)
C
C
0.25
REF
.010
1.87
-
0.05
+
0.13 .074
-
.002
+
.005
SECTION "B"-"B"
SCALE 3 : 1
C
SHEET OF
RIGHT ANGLE POWER TERMINAL
BY:
MPTC-XX-XX-XX-01-XX-X-RA-XX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
CLAY W
2/2/2007
4
2
SHEET SCALE: 1.5:1
REVISION S
F:\DWG\MISC\MKTG\MPTC-XX-XX-XX-01-XX-X-RA-XX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
5.00 .197
"D"
"E"
C
C
C
FIG 3
MPTC-02-80-02-01-XX-X-RA SHOWN
(SAME AS FIG 1, UNLESS OTHERWISE STATED)
-01 POWER
POSITION
-02 POWER
POSITION
P1
P2
P3 P4
0.50
SQ REF
.020
(SEE TABLE 1, SHEET 1)
"A"
.254
3.81
(TYP)
.150
2.00
(TYP)
.079
2.00
(TYP)
.079
2.79 .110
SECTION "F"-"F"
TERMINAL 1
(SEE TABLE 1, SHEET 1)
TERMINAL 2
(SEE TABLE 1, SHEET 1)
TERMINAL 3
(SEE TABLE 1, SHEET 1)
TERMINAL 4
(SEE TABLE 1, SHEET 1)
C
C
C
"F"
REF
1.00 .039
REF (TYP)
1.27 .050
REF (TYP)
3.30 .130
REF (TYP)
3.81 .150
19.55
REF
.770
25.60
REF
1.008
IN-PROCESS
C
SEE SHEET 5 FOR IN-PROCESS VIEWS
C
SHEET OF
RIGHT ANGLE POWER TERMINAL
BY:
MPTC-XX-XX-XX-01-XX-X-RA-XX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
CLAY W
2/2/2007
4
3
SHEET SCALE: 1.5:1
REVISION S
F:\DWG\MISC\MKTG\MPTC-XX-XX-XX-01-XX-X-RA-XX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
"F" REF
"E"
"D"
C
C
-01 POWER POSITION
"C" REF
FIG 4
**MPTC-01-24-01-01-XX-X-RA-SD SHOWN
(SAME AS FIG 1, UNLESS OTHERWISE STATED)
FIG 5
**MPTC-04-24-00-01-XX-X-RA-LC SHOWN
(SAME AS FIG 2, UNLESS OTHERWISE STATED)
P1 P2 P3 P4
SHEET OF
RIGHT ANGLE POWER TERMINAL
BY:
MPTC-XX-XX-XX-01-XX-X-RA-XX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
CLAY W
2/2/2007
4
4
SHEET SCALE: 2:1
REVISION S
F:\DWG\MISC\MKTG\MPTC-XX-XX-XX-01-XX-X-RA-XX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322