Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product with a voltage or current that
exceeds the rated range.
Applying a voltage or current that is higher than the rated range may
result in explosion or fire.
Do not miswire such as the polarity of the power supply
voltage.
Otherwise the product may be damaged or it may burn.
This product does not resist water. Do not use the
product in places where water or oil may be sprayed onto
the product.
When installing, arrange so that the heater portion cannot
be accessed by the end user.
Do not use the product in atmospheres or environments
that exceed product ratings.
Treat this product as industrial waste when disposing.
Mounting posture: Use this product standing vertically
(within ±3°).
Install with the suction inlet facing downwards and the
exhaust outlet facing upwards. Ensure that a space that
is the same as that specified on the following page is
secured in order to prevent the suction inlet and exhaust
outlet from becoming clogged with dust.
So that the detection area will be completely dark, place
a cap over the lens cleaning window.
Stable measurements can be performed approximately 1
minute after the power supply is turned on.
Remove any debris adhered to the lens using a dry cotton
swab.
When installing, arrange so that the heater portion cannot
be accessed by the end user.
Do not use organic solvents as they may alter lens
properties.
Elements of this product may be damaged or its reliability
may decrease due to surges in voltage caused by static
electricity, etc. When handling, take measures to prevent
static electricity, such as using wristbands or static
electricity preventing gloves.
Never insert or remove connectors while the power
supply is on.
Do not touch the pre-set resistors for adjusting sensor
sensitivity.
Do not apply mechanical stress to this product. Doing so
could result in damage to the product or defective sensor
properties. Also, sufficiently confirm that no such defects
have occurred when using while mounted to your
products.
Be aware that injuries may occur if sharp portions such
as the lead of the soldered surface or the edge of the
circuit board are touched when handling this product.
When handling this product, take care to prevent the lens
surface from being scratched or becoming dirty. Failure
to do so may result in changes to sensor properties. Also,
ensure that there is no freezing or condensation.
When inserting or removing connectors, do so in a level
and perpendicular manner. Never insert or remove
connectors by twisting vertically, horizontally, or in a
slanted manner. When inserting connectors, ensure that
they are fully inserted.
Do not use products that have been dropped. Doing so could
result in damage to the product or defective sensor
properties.
Only use after determining that usage is possible by
sufficiently evaluating for the following changes in
properties.
(a)Temperature properties (if there are changes in ambient
temperature when using this product, changes in output from
that sensor)
(b) Response properties (sensor output changes due to sampling
timing when using this product)
(c)Freezing/condensation conditions (if freezing or condensation
occur when using this product, changes in output from that
sensor)
Defects and damage caused by these changes in properties shall
not be covered by warranty.
CAUTION
Precautions for Safe Use
Precautions for Correct Use