Air Quality Sensor B5W-LD0101-1/2 Highly Sensitive and Compact Air Quality Sensor * Detection of particles down to 0.5 m in diameter is possible while using an LED light source * Features a unique flow path structure that efficiently sucks in air * Small in size thanks to its compact optical system RoHS Compliant Be sure to read Safety Precautions on page 4. Model Number Structure B5W- L D 01 01 - @ (1) (2) (3) (4) (5) (1) Standard type (3) Structure (5) Packing state L: 01: Basic structure 1: 2: Optical sensor (2) Sensor type (4) Function D: 01: Basic function Air Quality sensor 1 300 Ordering Information Appearance Sensing method Connecting method Output type Connector Pulse output (Built-in pull-up resistor 3 k ) 17.6 Light scattering 52.3 39.3 Model Packing state B5W-LD0101-1 1 B5W-LD0101-2 300 1 B5W-LD0101-1/2 Ratings, Characteristics and Exterior Specifications Absolute Maximum Ratings (Ta=25C) Parameter Symbol Ratings Unit Supply voltage VCC 5.5 V Input threshold voltage Vth 5.5 V Operating temperature Topr 0 to 45 C Storage temperature Tstg -25 to 65 C Exterior Specifications Connecting method Weight (g) Connector 20 Material Case Lens PC PMMA Electrical Characteristics (Ta=25C, Vcc=5 V, 0 Lx) Parameter Characteristics value Unit MIN TYP MAX VCC 4.5 5 5.5 V Vth Remarks Ripple voltage range 30 mV or less (*) is recommended 0 --- 3.5 V V (OUT1)/ V (OUT2) Hi level output 4.5 --- --- V Pulse output when particles are detected V (OUT1)/ V (OUT2) Low level output --- --- 0.7 V Pulse output when particles are not detected Supply current --- --- 90 mA LED-ON * Ensure there is no noise below 300 Hz. Confirm the allowable ripple voltage value using an actual machine. Detection Characteristics (Ta=25C, Vcc=5 V, 0 Lx) Parameter Characteristics value MIN TYP MAX V (OUT1) Number of detections PN1 --- 300 --- V (OUT2) Number of detections PN2 0 --- --- Unit Remarks Model of dust monitor: TSI DUSTTRAK II MODEL8530 Impactor: 1.0 m Dust concentration = 100 g/m3 Measurement time: 20 sec Threshold voltage: Vth=0.5 V count Detection object: 0.5 m Polystyrene latex particles count Minimum detectable particle V (OUT1): Approx. 0.5 m or larger V (OUT2): Approx. 2.5 m or larger 2 B5W-LD0101-1/2 Engineering Data (Reference value) Dust concentration - Number of Detected Particles Correlation Graph Number of 700 detected particles 600 [count] 500 V (OUT1) 400 300 200 100 V (OUT2) 0 0 100 200 300 400 500 600 Dust concentration [g/m3] Mesurement evironment Dust monitor Model: TSI DUSTTRAK II MODEL8530 Impactor: 1.0 m, Calibration factor=1 Air Quality Sensor Threshold voltage: 0.5 V Measurement time: 20 sec Detection object: Smoke of incense Conditions: Ta=25C, Vcc=5 V, 0 Lx Note: The above figure shows reference information from 30 pcs measurement. Output Signals High V (OUT1), V (OUT2) Low * * * * A positive pulse of 0 V is output when particles are not detected and 5 V when particles are detected Count the number of pulses within the measurement time and take this number to be the sensor count. The minimum pulse width is 0.5 msec. Use a sampling frequency of 4 kHz or more. Internal Block Diagram (1) Vcc 3 k Sensing station 3 k (2) V (OUT1) Signal processing 1 (5) V (OUT2) Signal processing 2 (3) GND (4) Vth * * For operation, the input threshold voltage Vth must be set to between 0.5 and 3.0 V. The recommended threshold voltage Vth is 0.5 V, which is same detection characteristics for ratings, characteristics and exterior specifications. 3 B5W-LD0101-1/2 Safety Precautions To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor. CAUTION This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Safe Use Do not use the product with a voltage or current that exceeds the rated range. Applying a voltage or current that is higher than the rated range may result in explosion or fire. Do not miswire such as the polarity of the power supply voltage. Otherwise the product may be damaged or it may burn. This product does not resist water. Do not use the product in places where water or oil may be sprayed onto the product. When installing, arrange so that the heater portion cannot be accessed by the end user. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Treat this product as industrial waste when disposing. Mounting posture: Use this product standing vertically (within 3). Install with the suction inlet facing downwards and the exhaust outlet facing upwards. Ensure that a space that is the same as that specified on the following page is secured in order to prevent the suction inlet and exhaust outlet from becoming clogged with dust. So that the detection area will be completely dark, place a cap over the lens cleaning window. Stable measurements can be performed approximately 1 minute after the power supply is turned on. Remove any debris adhered to the lens using a dry cotton swab. When installing, arrange so that the heater portion cannot be accessed by the end user. Do not use organic solvents as they may alter lens properties. Elements of this product may be damaged or its reliability may decrease due to surges in voltage caused by static electricity, etc. When handling, take measures to prevent static electricity, such as using wristbands or static electricity preventing gloves. Never insert or remove connectors while the power supply is on. Do not touch the pre-set resistors for adjusting sensor sensitivity. Do not apply mechanical stress to this product. Doing so could result in damage to the product or defective sensor properties. Also, sufficiently confirm that no such defects have occurred when using while mounted to your products. Be aware that injuries may occur if sharp portions such as the lead of the soldered surface or the edge of the circuit board are touched when handling this product. When handling this product, take care to prevent the lens surface from being scratched or becoming dirty. Failure to do so may result in changes to sensor properties. Also, ensure that there is no freezing or condensation. When inserting or removing connectors, do so in a level and perpendicular manner. Never insert or remove connectors by twisting vertically, horizontally, or in a slanted manner. When inserting connectors, ensure that they are fully inserted. Do not use products that have been dropped. Doing so could result in damage to the product or defective sensor properties. Only use after determining that usage is possible by sufficiently evaluating for the following changes in properties. (a)Temperature properties (if there are changes in ambient temperature when using this product, changes in output from that sensor) (b) Response properties (sensor output changes due to sampling timing when using this product) (c)Freezing/condensation conditions (if freezing or condensation occur when using this product, changes in output from that sensor) Defects and damage caused by these changes in properties shall not be covered by warranty. 4 B5W-LD0101-1/2 Dimensions (Unit: mm) Air Quality Sensor B5W-LD0101-1/2 6 or less Mounting range Center of exhaust 1.3 outlet 1 3 0.3 50 46 0.2 0.3 2x13.8 8.5 37 39.3 2x3 Unless otherwise specified, the tolerances are as shown below. 24.5 Dimensions Tolerance 3 mm max. 0.20 3 < mm 6 0.24 17 1.6 16 Pin Terminal name Remarks (1) VCC Input voltage pin (2) V (OUT1) Output voltage pin 1 (3) GND Ground pin (4) Vth Input threshold voltage pin (5) V (OUT2) Output voltage pin 2 41.6 52.3 Center of suction inlet 6 < mm 10 0.29 10 < mm 18 0.35 18 < mm 30 0.42 Heater (1)(2)(3)(4)(5) 30 < mm 50 0.50 50 < mm 80 0.60 Note: Dimensions in parentheses are for reference only. Connector on circuit board side: AMP 292164-5 Number of terminals: 5 pin Recommended mating connectors: AMP173977-5 Mounting Conditions The recommended dimensions for the suction inlet and exhaust outlet of the Air Quality Sensor are as follows. Mount the Sensor with the suction inlet down and the exhaust outlet up as shown in the figure below. Secure the spaces shown in the figure. Align with the center of the sensor opening Mounting direction (upper) Unit: mm 10 or more 10 or more Align this surface with the exterior of the sensor 10 or more 25 or more Align this surface with the exterior of the sensor Align with the center of the sensor opening Note1: Ensure that the suction inlet and exhaust outlet are as close to the sensor case in the forward and rear directions as possible Note2: Install to the flat part using an M3 screw with a tightening torque of 0.54 N*m or less. 5 * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. E475-E1-03 0419(1117)(O)